Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.3 LAccepted-AOC | L1 | Accepted-AOC Being L-1 | |
| 2 | L2₹99.5 L+₹11.6 L (13.2%)Rejected-Finance B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | L2 | Rejected-Finance Being L-2 | |
| 3 | L3₹1.0 Cr+₹12.3 L (14.0%)Rejected-Finance ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | L3 | Rejected-Finance Being L-3 | |
| 4 | L4₹1.0 Cr+₹14.6 L (16.6%)Rejected-Finance 302 SIDDHIVINAYAK APPT A WING MUMBAI K K MARG JACOB CIRCLE MUMBAI CITY MAHARASHTRA 400 011 | MUMBAI | MAHARASHTRA | 400011 | L4 | Rejected-Finance Being L-4 | |
| 5 | L5₹1.1 Cr+₹24.6 L (28.0%)Rejected-Finance UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L5 | Rejected-Finance Being L-5 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
28 Jun 2023, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS TO BLDG NO- P-144, P-145 AND P-164 AT NCHC POWAI
2023_MES_600019_1
8451/E8
Open Tender
Civil Works
Item Rate
270 days
POWAI
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹2.0 L
Yes
28 Jul 2023
31 May 2023
1 Jul 2023
31 May 2023
28 Jun 2023
21 Jun 2023
Amount
SCH 'A' PART I (B/R WORK) Taking down cement plaster or lime plaster from concrete or brick wall, ceiling including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
Taking down chowkats or frames, exc 1.5 sqm but not exc 4 Sqm each with shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also Grills/Guard bars (where exists), complete all as specified and directed.
Taking down chowkats or frames, not exc 1.5 sqm each with shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also Grills/Guard bars (where exists), complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and refixing in the same opening and complete all as specified and directed.
Demolition of cement concrete in ground floors (un-reinforced) and paving not exc. 15cm thickness (below or above ground level) including removing debris outside MD land complete all as specified and directed.
Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land, complete all as specified and directed.
M&L for brick work with sub class B old size bricks and of class designation 35 (min, compresive strength 35 Kgf/Sqcm) straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for Brick work with Sub class 'B' old size Bricks and of class designation 35 (min, compresive strength 35 Kgf/Sqcm), straight or curved on plan to any radius, as in half brick thick wall built in CM (1:4), complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick or concrete surfaces of walls including finishing the surface even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 20mm thick in cement mortar 1:4 in two coats (15+5mm) both coats mixed with water proofing compound @ 2% by weight of cement, fair faces of brick or concrete surfaces of top layer finished even and smooth (without using extra cement) including necessary scaffolding etc complete all as specified and directed. Note : WPC will be measured and paid separately as supply only.
M&L for rendering 5mm thick in cement mortar (1:3) to ceiling and finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
Supply only integral water proofing compound.
S&F Second class Hard Wood (SAL/Hollock/Kalasiris) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints etc complete all as specified and directed.
M&L for 2nd class hard wood (sal/Hollock/Kabsiris) plain fillets square, rectangular or triangular in section, clean swan, secured with nails, sectional area exc 13 and not exc 25 Sq.cm, complete all as specified and directed
S & F 2nd class hard wood (sal/Hollock/Kabsiris) factory made 35mm thick plain, framed panelled shutter (two panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12 mm veneered particle board with commerical veneering in both faces. The size of rails and stiles shall be as per IS:1003 (Part-I), kiln seasoned and chemically pressure treated of 2nd class hard wood (Hollock/Sal/Kalasiris), complete all as specified and directed.
S&F factory made 35mm thick 2nd class hard wood (SAL/HOLLOCK/KALASIRIS) Kiln seasoned and chemically pressure treated, glazed and skelton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges, of framing plain, chamfered or rounded, fitted with cut and mitred bends for securing glass etc, sizes of members of shutters as specfied in SSR Part I, Section 8, cluase 8.24 (a) ; supplied and fitted to chowkats complete all as specfied and directed.
S & F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and shown in drg for SI No. 8095 on ser page No. 160 in SSR-2010 (Pt-II), complete all as specified and directed.
S&F factory Made solid Panel PVC Door Shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet with Free EPS shall be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, as per specification & drawing for SI No.8080 on ser page No.156 in SSR-2020 (Pt-II), complete all as specified and directed.
S&F hold fasts and similar small articles made out of mild steel Flat etc of grade Fe-290 Gde - E-165 etc complete all as specified and directed.
M & L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in bed blocks for hold fasts including necessary form work complete all as specified and directed.
M&L for preparing surfaces of wood and wood based materials, steel and iron work, new or old of any description and girth not otherwise described and treated with tar or coal tar black paint, complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing glazing clips etc complete all as specified and directed. (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes, wire cloth shall be measured and paid separately as supply only under respective items.
Supply only 4.8 mm thick sheet glass ordinary quality and glazing with beading in square n. exc 0.5 sqm in each pane complete all as specified and directed.
Supply only 4mm thick figured glass/pin headed type and glazing with beading in square n exc 0.5 sqm in each pane complete all as specified and directed.
Supply only aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm, complete all as specified and directed.
S&F mild steel Framed work such as grills, gratings etc, with ends of bars shouldered or rebated or forged into spikes, framed guard bars, barred iron doors, railings, framework of water tanks and similar work conforming to Fe -290 Grade -E-165, complete all as specified and directed.
S&F aluminium anodised Grills of approved design for window / ventilators and fixing with F/U channel all as specified and directed. Note: The Grills shall be of Model DG-102 or any other Model of Make Deco or equivalent make as approved by the GE.
S&F stainless steel butt hinges, medium weight, bright finished 100mm long, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section, 150mm long, complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F aluminium anodised bow handles of 150mm size, fabricated type of extruded section fixed with screws to shutters, complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 m and turnings) duly filled with fine sand and bitumen in the ratio of 3:1, complete all as specified and directed.
S & F in repairs cast iron Nahani trap with grating including jointing to waste pipe of 75mm dia in and including cement concrete type B1 (1:2:4) , complete all as specified and directed.
Dismantling floor, hearth or wall tiling and stone slabs including cement mortar bedding (but not backing), removing rubbish off the premises outside MD Land complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 10mm thick rectangular area of each tiles exc 0.18 sqm but n exc 0.36 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for Non-skid ceramic tiles (Coloured) 10mm thick rectangular area of each tiles exc 0.18 sqm but n exc 0.36 sqm in vertical surfaces such as skirtings, dados etc,.set and jointed in neat cement paste and pointed in white or coloured cement to match including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles.complete all as specified and directed.
M&L for coloured Non-skid ceramic tiles 7 to 8mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 15mm thick cement mortar screed bed in CM 1:6 complete all as specified and directed.
M&L for 300x200x7mm thick coloured glazed ceramic tiles on vertical surfaces such as skirting,dado and risers to steps etc, set and jointed in neat cement paste and pointed in white cement mixed with pigment to match, over and including 10mm thick cement mortar backing coat in CM 1:4 complete all as specified and directed.
Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MOD land complete all as specified and directed.
M & L for filling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion complete all as specified and directed.
M & L for special treatment for sunken portion of WCs/Bath & toilet executed in following stages :- Stage 1: Providing 15mm thick plaster in CM 1:3 mixed with water proofing chemical of Dr.Fixit or Shalicrete 'R' of STP Ltd in the proportion/quantity all as per manufacturer's instructions. Stage 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces. Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer's instructions. Stage 4: Laying fiber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky. Stage 5: After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer's instructions. Stage 6: Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer's instructions. Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i) Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid .(ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
S&F in repairs, vitreous China, Ist quality, squatting pan (Orissa pattern), of size 580x440mm, white, with and including 'P' or 'S' trap, integral foot rests, lime concrete bedding inlcuding dismantling existing lime concrete bedding, unserviceable connections etc and connecting up, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 15mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 20mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 25mm bore, complete all as specified and directed.
Supply and laying of 16 mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings (including special fittings i.e. brass elbow, brass tee, Male brass threaded adaptor, female threaded adaptor etc required for fixing of bib tap, stop valve with CPVC pipes) concealed in walls/ ceiling or laying in floors etc.including cutting chases in walls for concealed tubing and making good the same in CM 1:3 after fixing of pipes / fittings, complete all as specified and directed.
Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings of size 20mm outer diameter (including special fittings (brass elbow, brass tee, Male threaded brass adaptor, female threaded brass adaptor etc required for fixing of bib tap , stop valve ) fixed on the surfaces of walls / ceiling with suitable size GI clamps or laying over floors complete all as specified and directed
Supply and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings of size 25mm outer diameter (including special fittings (brass elbow, brass tee, Male threaded brass adaptor, female threaded brass adaptor etc required for fixing of bib tap , stop valve ) fixed on the surfaces of walls / ceiling with suitable size GI clamps or laying over floors complete all as specified and directed’’
S & F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia, complete all as specified and directed.
S&F in repairs Vitreous China, 1st quality, white, wash hand basin, flat back, size 450mm x 300mm including mild steel angle brackets and waste coupling of PTMT 40mm dia including cutting for and pinning ends of brackets, complete all as specified and directed .Note :Pillar tap will be measured and paid separately under respective item.
S&F in repairs pillar taps, cast copper alloy, chromium plated, screwed down, high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe of 15mm bore, complete all as specified and directed.
S&F in repairs stop valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, fancy type, chromium plate, with long shank and cup (concealed type) screwed both ends for iron pipe of 15mm bore, complete all as specified and directed.
S&F in repairs 15mm bore bib taps, cast copper alloy with crutch or butterfly handle, fancy type, chromium plated, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15mm size PVC connection with PTMT nuts 450mm length, complete all as specified and directed.
S&F in repairs brass chromium plated, shower rose, 125mm size, complete all as specified and directed.
S&F towel rail 600mm long of PTMT (min weight 190 grams) fixed with and incl chromium plated brass screws and wooden / plastic cleats, complete all as specified and directed.
S&F 32mm bore high density polyethylene pipes (HDPE) of pressure rating 6 Kgf / cm2, fixed to walls, ceiling or laid in floors etc, complete all as specified and directed.
S & F 160 mm bore UPVC Rain Water Pipe type 'A', single socketed, in any length with and including ruber ring joints, complete fixed to wall with necessary stay clamps including taking down existing RWP of any description, complete all as specified and directed.
S&F 160 mm bore UPVC (SWR) Bends/Shoes with and including rubber ring joints, complete all as specified and directed.
M & L for machine cut cudappa stone slab 20-25mm thick laid over and including cement screed bed CM 1:4 10 mm thick laid and jointed with grey cement slurry mixed with pegment to match the shade of the slab including rubbing and polishing as in cill/wall cladding etc complete all as specified and directed.
M&L for 20mm thick granite(of any type) work table rubbed and polished as in jambs, pillars, door and windows-cill, cooking platform wash basin platform and the like in cement mortar (1:4) including pointing in white / coloured cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting of oval shape for fixing of counter wash hand basin etc over and including 10mm thick rendering / screed in CM 1:4 on fair faces of brick/concrete surfaces complete all as specified and directed.
Taking down CI soil/waste and vent pipes of any length any size including fittings including cutting of holes wherever required.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
M & L for applying two coats of oil bound distemper with roller over one coat of alakali resistant primer,after preparation of new surfaces of walls etc, complete all as specified and directed.
M&L for complete removal of existing treatment of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss efflorescent salts, trading oil and greasy spots including washing down with water and applying two coats of oil bound distemper with roller over one coat of alakali resistant primer, complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying one coat of Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding complete all as per manufacturers instructions and all as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for preparing the plastered surfaces of existing exterior walls, parapet walls, chajjas, etc. with wire brush to remove all loose dirt, oil grease, etc. and applying one coat of Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M & L for preparation of old plastered surfaces of ceiling and applying one coat of white wash, complete all as specified and directed.
M&L for PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregate) as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
Dismantling of existing water proofing treatment of any thickness in any position and of any portion from top of roof of building, cleaning surface of roof with wire brush / mechanical brush and clean with water thoroughly to remove all dust / dirt and loose particles to expose base concrete roof slab and removal of rubbish / demolished material out of MD land complete all as specified.
M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm. (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%.
M&L for machine pressed cement concrete tiles of size 300x300X20mm thick (with grey cement and no pigment), set in neat cement slurry laid over terrace and roofs etc including provision of 15mm thick cement screed bedding layer in CM 1:4 mixed with integral water proofing compound, tiles joints shall be grouted immediately after grouting, the joints shall be pointed flush in CM 1:3 (in separate process) mixed with integral water proofing compound complete all as specified and directed. (Note : Integral water proofing compound will be measured and paid separately as supply only).
M&L for applying one coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over APP roof membrane, complete all as specified and directed.
M&L for Providing 2 to 2.50mm thick FRP chajja of approved pattern/shape/size (with sides & front drop etc), colour/pattern as of Mangalore clay tile (the FRP chajjas shall be moulded in gel coat finish, the thickness shall be 4 mm and back patti to be additionally reinforced with core matt, all resins and pigment shall be fully weatherable and UV established, core malt shall be used with GSM for extra thickness, necessary FRP covered metal), chajjas shall be fixed in position with and including 8mm dia and 125mm long split fastener bolts (Shakti or equivalent as approved by the GE) spaced not more than 45cm C/C and also filling the gaps with polysulphide sealant including necessary scaffolding/erection of working platform etc, complete all as specified and directed. Make : M/S Titan Enterprises or Advance FRP or Sintex.
M&L precast reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregates) set in cement mortar 1:6 as in cover slabs, shelves and the like including weathering, slightly rounded or chamfered angles and throating, also including use and waste of form work, complete all as specified and directed, Note : Reinforcement shall be measured and paid separately.
M& L for Mild steel TMT bars 08 mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete and removing the retreived debris out side MD land, complete all as specified and directed.
Supplying and fixing rotational moulded polythylene water storage tanks white colour, double layered (ISI marked) of 2000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connecting the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F in repairs Ball brass valves of size 20 mm bore high pressure, the polythene float and fly nut, screwed for iron pipe or brass frame ferrule complete al as specified and directed.
S&F Anodised Aluminium alloy curtain rails 20 mm dia chromium plated, with and including fixing brackets, stops, rollers etc, complete al as specified and directed.
S&F in repair 25mm bore gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipes, complete all as specified and directed.
S&F sinks made of stainless steel 1mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe including 40mm bore PVC waste pipe, overall size 495mm x 420mm with bowl size 410mm x 330mm x160mm, complete all as specified and directed.
S&F stainless steel kitchen plate rack, Cat NoP-348 of Prayag Polymers Pvt Ltd or equivalent as approved by the GE, complete all as specified and directed.
M&L for 75mm thick cement conrete 1:4:8 (type D-2) (using 40mm graded stone aggregate) as in sub base, finished even and fair to achieve the topping layer of tiles, complete all as specified and directed.
M&L for chequered cement concrete tiles 25cm x 25 cm x 22 mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry in floor with grey cement mixed with pigments to match with the colour of tiles, laid over and including 20 mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L for 18/19 mm thick marine ply bonded with undiluted Phenol Formaldehyde resin, Boiled Water Proof, Specific gravity 0.80 (minimum), moisture content 8-12 %, water absorption <5 %, provided with and including 1mm thick plastic laminated sheet on one side of plywood (Plastic laminated sheet shall be with decorative choice lamination on one side and other side balancing) (Make of ply : Anchor, Kitply, Century, Green Ply) as in kitchen cabinets, cub board, shelves etc, fixed with screws to timber frame work including dismantling existing boarding of any description complete all as specified and directed.
S&F continous (piano) hinges, mild steel, bright finish or electro-galvanised width of Flaps (when open) 30mm, complete all as specified and directed.
M&L for chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked,single component ready to use microconcrete from FOSROC (Renderoc RG) or equivalent or Dr fixit as appoved by GE, at any level/height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing, laying, levelling, finishing, curing etc as per manufacturers specifications and all other relevant works, complete all as specified and directed. Note : Reinforcement only shall be measured and paid separately)
S&F TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welding if required complete all as specified and directed.
S&F TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips or welding if required complete all as specified and directed.
All as per item No. 109 above but for stirrups complete all as specified and directed.
M&L for post construction Antitermite treatment along the external wall below concrete or masonry apron using chlorophyriphos emulson (1% concentration) conforming to IS -8944 @2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
M&L for post construction Antitermite treatment to the top surface of existing floor using chlorophyriphos emulsion (1% concentration) conforming to IS-8944 @ one litre per hole 300mm apart including drilling & plugging 12mm dia. holes with CM (1:2 ) to match the existing floors, complete all as specified & directed.
M&L for post construction ATT at points of contacts of wood work using chlorophyriphos emulsion (1% concentration) conforming to IS-8944 ( in oil or kerosine based solution) @ 0.5 lt/ hole by drillng 6mm dia holes at a down ward angle of 45 degree at 150 mm centre to centre and sealing the same, complete all as specified and directed.
M & L for 20 to 25 mm thick machine cut kota stone slab of size 590mm x 590mm in flooring, laid over and including 20 mm thick screed bed in CM 1:4, set and jointed and pointed in neat cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc complete all as directed and specified.
M&L for 20-25mm thick machine cut and pre polished Kota stone slab in single piece as in skirting, dado,pillars, risers and treads of steps (including making 3 grooves on the Kota Stone of treads), skirting & dado, Jambs, Cills, Plateform etc over and including 15 mm thick cement mortar backing coat in CM 1:4, jointed and pointed with cement slurry mixed with pigment to match the shade of the slab, complete as specified and directed.
M&L for half Rounding to edges of stone slabs as in steps and other similar situations, complete all as specified and directed.
SCH 'A' PART II - E/M WORK M & L for taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including fittings such as switches, ceiling rose, pendents, regulators, sockets etc and making good disturbed surfaces of walls complete all as specified.
M & L for taking down carefully old unserviceable Ceiling fan and deposited to MES store yard.
M&L for taking down old undericeable MCB DBs including MCBS
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor conforming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 25mm width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed Note : Modular Metal Flush Box, cover plate and frame shall be measured and paid separately.
One light point controlled by one switch
One fan/exhaust fan point controlled by one switch
One 3 pin socket point 5A controlled by switch on same board
One 3 pin socket point 5A controlled by switch on independent board
One bell point controlled by one switch
One light point controlled by two 2 way switch
M&L for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire conforming to IS-694, Part-II, ISI marked with multistranded copper conductor drawn in and including PVC casing caping (minimum 25mm in width) fixed on the surfaces of wall, ceiling with all accessories, fittings, PVC junction boxes also including 2.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent complete all as specified and directed. Note : Modular Metal Flush Box, cover plate and frame shall be measured and paid separately.
Supply & Fix Bell, AC, 230 Volts, single pole, complete all as specified and directed
Supply and fix modular bell push, 6 Amp, 1 module, complete all as specified and directed.
Supply and fix modular switch, 2 way, 6 Amp, 1 module, complete all as specified and directed.
Supply and fix modular switch, 1 way, 6 Amp ,1 module, complete all as specified and directed.
Supply and fix modular switch, 1 way ,16 Amp, 1 module, complete all as specified and directed.
S&F ceiling rose three terminal, 230 Volts, PVC / Polycarbonate body, complete all as specified and directed.
Supply and fix Modular socket outlet, 6 Amps, 2/3 pin combined 2 module, complete all as specified and directed
Supply and fix Modular socket outlet 6A/16 Amps, 2/3 pin combined 2 module, complete all as specified and directed
Supply and fix modular fan step regulator, 120W, 2 module, complete all as specified and directed.
Supply and fix concealed modular metal flush box 19 SWG (1mm thick) GI coating with and including matching modular white cover plate with frame, 1/2 module, complete all as specified and directed.
Supply and fix concealed modular metal flush box 19 SWG (1mm thick) GI coating with and including matching modular white cover plate with frame, 3 module, complete all as specified and directed.
Supply and fix concealed modular metal flush box 19 SWG (1mm thick) GI coating with and including matching modular white cover plate with frame, 4 module, complete all as specified and directed.
Supply and fix concealed modular metal flush box 19 SWG (1mm thick) GI coating with and including matching modular white cover plate with frame, 6 module, complete all as specified and directed.
Supply and fix concealed modular metal flush box 19 SWG (1mm thick) GI coating with and including matching modular white cover plate with frame, 8 module, complete all as specified and directed.
Supply and fix ceiling fan complete with blades, down rods, electronic regulator and accessories 230 Volts, 1200mm,sweep, min air delivary 210CFM with service value 6 BEE. Five star rated with brushless direct current motor (BLDC) all as specified and directed.
Supply and fix heavy duty metallic exhaust fan of sweep 300 mm making suitable size opening for exhaust fan and making good disturbed surfaces as per existing complete all as specified.
S&F LED Batten T-5 ,integrated sleek extruded LED channel with acrylic cover, with and including 18/20 Watt white light and driver, prewired, provision of 0.5 Sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed.
S&F LED Batten T-5 ,integrated sleek extruded LED channel with acrylic cover, with and including 10 Watt white light and driver, prewired , provision of 0.5 Sqmm 3 core flexible copper conductor wire for connecting from ceiling rose, complete all as specified and directed.
S & F MCB DB, 08 way, SPN, double door, 240 Volts with 200 Amps rated copper bus bar fixed concealed/ surfaces on the wall, making all connections, complete all as specified and directed.
S&F in repairs MCB, SPN 40Amps 10KA, 230 Volt 'C' Curve and connecting the incoming and out going cables by using copper lugs pin type complete all as specified.
S&F MCB SP 6-32 Apms, 240 Volts 'C' Curve complete all as specified and directed
M&L for sub main wiring complete with Two runs of 4 Sqmm single core PVC insulated, unsheathed,heavy duty, 1100 Volt grade multistranded copper conductor cable (FRLS) and drawn through and including PVC conduit (minimum 20 mm dia) on the surfaces of the walls with all accessories, fittings etc including one run of PVC insulated and unshethed copper conductor 4.00 Sqmm single core cable (FRLS) as earth continuity conductor, connected with earth dolly and mains including taking down existing sub main wiring complete all as specified & directed. Note: Three run of 4 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.
Supply and lay 80mm bore galvanised steel tubing will all fittings and fixed to wall and ceiling or laid in floor including taking down existing tubing complete all as specified.
All as per above item No 144.00 above but 50mm bore
All as per above item No 144.00 above but 40mm bore
All as per above item No 144.00 above but 25 mm bore
Supply and fix in repair gun metal gate valve with iron wheel head of size 40 mm with external threaded both ends for connecting to pipe line including all as specified and directed.
All as per above item No 152.00 above but 25 mm bore
S&F 40mm bore ball brass valves, high pressure with polythene float and flynut complete, screwed for iron pipe brass ferrule and fixed
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables, pipes etc complete all as specified.
Returning, filling in, including spreading , levelling , watering and well ramming in layers n.exc 25 cm complete all as specified.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified.
M&L for earthing complete with galvanised earth plate electode 600 x 600 x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to and including galvanised earth wire 4mm dia as earth lead by means of bolts, nuts, check nuts adn washes of galvanised iron with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I, including watering arrangement with GI pipe 20mm bore (medium grade), earth lead protection pipe 15mm bore light grade with bends, elbow etc. including excavation and earth work, returning, filling, ramming and removing of soil to a distance not exc 50 metre in any type of soil, making PCC 1:2:4 type B-1 pit (Earth chamber) with RCC 1:2:4 cover 50mm thick reinforced with XPM and testing on completion including making test point on wall complete all as specified and directed. (Note: Cost of GI earth wire and protection pipe upto 7.5 metre shall also be deemed to be included in the quoted rate)
S&F in repairs pressure die cast housing with epoxy power coated dark graphite grey colour finish. Prismatic polycarbonate cover with individual LED lenses IP65 35 watt, AC 240 Volts 50 HZ complete all as specified. Make: Bajaj /Halonix/C&S
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified
Supply and laying in trenches 32 mm bore High density polyethylene pipes (HDPE) for cable protection of pressure rating 6 kgf/cm2 complete all as directed.
S&F in in repairs GI pipe 50 mm bore light grade with all fittings for cable protection .
Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal and Design, fabricating, suppling and fixing indoor type vermin and weather proof totally enclosed cubical type front operated single door with seperate compartment with view glass for taking meter reading, fabricted out of 2 mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens grey colour and with industrial type built in locking arrangement. The meter box shall be factory made from a reputed pannel fabricators (CPRI approved manufacturers). The panel shall be wall/floor mounting type and to be fixed with all necessary fixing arrangements such as angle iron brackets and frame. The panel to be prewired with PVC insulated copper conductors for monitors and Copper busbar with heat shrinkable sleeves of capacity 200 Amps for connecting the incoming MCCB and out going and including digital type multifuction meter with the following items. (For bldg No 144 &164)
(a) Copper busbar 200 Amps for phases and neutral duly sleeved with heat shrinkable insulation using colour code for R Y B &N set of 4- 01 Set. (b) MCCB 4 pole 100 Amps 415 Volts 25 KA- 01(incommer) (c) Fixing the existing electric energy meters -09 Nos obntained from the existing panel of respective Qtrs (d) MCB SPN 32 Amps, 'C' curve 230 Volt -09 Nos (out going) (e) Indicator lamp complete with lamp holder LED type set of 03-01 set (g) VAF+ PF meter CL-0.5, input Voltage-50-520 VAC, CT 1A/5 A, Parameter VLL,VLN,A, F& PF digital type meter of size 96mm x 96mm - 01 No
Vishal Builders
mp construction co
the bhimani group of companies
Joy builders
R J ENTERPRISES
Star Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .