EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Development of Shrine Premises and Bada Talab at Charisharief B.W.O Development of Shrine premises at Charrarishareif by way of ornamental canopy and installation of LED Luminaries with allied accessories like wiring controlling, protection switch ge
2026_PWDJK_304706_2
NIT No.306/2025-26 Dt/27/02/2026
Open Tender
Electrical Works
Percentage
Charisharief
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹4,343
6 Apr 2026
27 Feb 2026
7 Mar 2026
27 Feb 2026
6 Mar 2026
27 Feb 2026
Supply and fixing of 10-12 Watts LED recessed (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing should made of pressure die-cast aluminium. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver Approved make Philips / Lighting techology / Trilux /Regent /Endo (to be approved before installation)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required.of Salzar /Polycab /Finolex /RR Kabels make
2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrend /L&T /ABB /Simens /Schinder make
16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /L&T /Simens / eq. make to be approved by EIC
Supplying and fixing of 63 Amps rating DP 240/415 volts c cURVE (10KA) of Legrend /L&T /ABB /Simensmake dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make
earthing with GI rod of 6 ft long perforated type to be embedded in a pit with extending of earthing from rod to pole by way of p/l of 8 No SWG insulated bare GI Wire strip from electrode to deice
Supply and laying of 40 mm dia HPPE flexible Pipe (air Cusion type heavy duty ) for laying of Cables in cable trench.
Supply, Laying, Testing and Commissioning of XLPE insulated PVC inner sheathed steel armoured Al Cable of Havells /Grandlays /Polycab make incl making of necessary connections with proper size of Al Thimbles dully crimped with crimping tool
10 sq mm 2- Core
earthing with GI rod of 6 ft long perforated type to be embedded in a pit with extending of earthing from rod to pole by way of p/l of 8 No SWG insulated bare GI Wire strip from electrode to deice
Supply and laying of 40 mm dia HPPE flexible Pipe (air Cusion type heavy duty ) for laying of Cables in cable trench.
Supply/ installation/testing and commissioning of Outdoor type Wall / floor mounted compartmentalized Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel , provided and fitted with 100- 200 P&N Colour Coded Bus Bar (As per instructions of EIC) and should be provided with indicators ,Voltmeter ,ammeter ,CT Coils etc .The Panel should have spacing for accomadating of 63-100 Amps TPN MCCB /MCB (Excluding cost of MCCB/MCB) but including cost of Bus Bar ,indication and metering devices. The Panel Should also have Spacing of outgoing MCB's equivalent to 12 Way DB Box (To be fabricated as per instructions of EIC Before submitting of SDL) The above mentioned quantities are for one panel and in total three (3 No) panels indual panels are to be fabricated having 1 No's of 3 ft x 2 ft x 1 ft =6 sft The job includes providing and fixing of angle iron stand ahving minimum height 2.5 ft with four no of angle iron legs to be grouted in cement concrete upto 1 ft complte job including cost concreting 1:3:6
Supplying and fixing 100 rating, 240/415 V, 10 kA, "C" curve DP MCB , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required. Of Legrend /L&T/ ABB / Scheinder make
Supply ,installation ,Testing and Commissioning of 63-100 Amps 4-pole Connector
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 1.93 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.10 MB
BOQ_989815.xls
BOQ • 2.94 MB
corrigendumNIT306PART2.pdf
PDF • 0.57 MB
CorrigendumnitNit306.pdf
PDF • 4.54 MB
corrigendumNIT306B.pdf
PDF • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .