Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
22 Nov 2021, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Erection of HT, LT Line and shifting of HT and LT line
2021_PDD_142231_1
ED/UDH/33 of 2021-22 dt. 01-10-2021
Open Tender
Electrical Works
Turn-key
90 days
District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer, Electric Division JPDCL
₹32,000
6 Dec 2021
4 Oct 2021
24 Nov 2021
4 Oct 2021
22 Nov 2021
4 Oct 2021
4 Oct 2021 - 11 Oct 2021
Survey, Design, Supply, Transportation, Carriage for shifting of Electric poles/Electric Lines coming in the alignment of road from Basantgarh to Khaned under PMGSY Phase-VII, Stage-I package No. JK14-105.
9 mtr long ST Pole (ST-410SP33)
8 mtr long ST Pole (ST-410SP15)
GI V-Crossarm with top Bracket including clamps/Angle Iron
0.03 ACSR Weasel conductor
11KV polymeric composite Pin insulator 12 KV, 5KN, lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11KV polymeric composite Disc insulator 12 KV, minimum failing load 45 KN lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11 KV GO Switch, 3 pole, 3 phase, vertical 200 A
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines
Painting of 8/9 mtr long ST poles including crossarms/clamps with one coat of Red oxide Paint
Painting of 8/9 mtr ST long poles including crossarms/clamps with two coat of Aluminium Paint
Cement Bottoming 1:2:4 mix as per REC Strandards
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismentalling and re-erection of Existing poles 8 mtr long ST
Dismentalling and re-erection of GI Channel X-arm including clamps and braces
Dismentalling and re-erection of 30 mm Sq. ACSR Conductor
Survey, Design, Supply, Transportation, Carriage for shifting of HT/LT line from PMGSY road corridoor under construction from Parla Chakkal to Balota under PMGSY phase-VII, stage-I package No. JK14-161 .
8 mtr long ST Pole (ST-410SP15)
GI V Cross -arm with top Bracket including clamps/Angle Iron
0.03 ACSR Weasel Conductor
11KV polymeric composite Pin insulator 12 KV, 5KN, lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11KV polymeric composite Disc insulator 12 KV, minimum failing load 45 KN lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11 KV GO Switch, 3 pole, 3 phase, vertical 200 A
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismentalling and reerection of Existing poles 8 mtr long ST
Dismentalling and re-erection of GI Channel X-arm including clamps and braces
Dismentalling and re-erection of 30 mm Sq. ACSR Conductor
Survey, Design, Supply, Transportation, Carriage for shifting of Electric poles/Electric lines coming in the alignment of road from Punara Lower to Kadhwha Bathian under PMGSY phase-X, stage-I.
8 mtr long ST Pole (ST-410SP15)
GI V Cross -arm with top Bracket including clamps/Angle Iron
0.03 ACSR Weasel conductor
11KV polymeric composite Pin insulator 12 KV, 5KN, lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11KV polymeric composite Disc insulator 12 KV, minimum failing load 45 KN lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismentalling and re-erection of Existing poles 8 mtr long ST
Dismentalling and re-erection of GI Channel X-arm including clamps and braces
Dismentalling and re-erection of 30 mm Sq. ACSR Conductor
Survey, Design, Supply, Transportation, Carriage for shifting of Electric poles/Electric Lines coming in the alignment of PMGSY road from Bandhole to Parla Chapper including dismentalling and erection of already erected poles under package No. JK14-521 .
9 mtr long ST Pole (ST-410SP33)
GI V Cross -arm with top Bracket including clamps/Angle Iron
0.03 ACSR Weasel Conductor
11KV polymeric composite Pin insulator 12 KV, 5KN, lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11KV polymeric composite Disc insulator 12 KV, minimum failing load 45 KN lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines
Painting of 9 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint
Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismentalling and re-erection of Existing poles 8 mtr long ST
Dismentalling and re-erection of GI Channel X-arm including clamps and braces
Dismentalling and re-erection of 30 mm Sq. ACSR Conductor
Survey, Design, Supply, Transportation, Carriage for shifting of Electric poles/Electric Lines coming in the alinment of PMGSY road from Bandhole to Upper Pattangarh including dismentalling and erection of already erected poles under PMGSY phase-X stage-I.
8 mtr long ST Pole (ST-410SP15)
GI V Cross -arm with top Bracket including clamps/Angle Iron
0.03 ACSR Weasel conductor
11KV polymeric composite Pin insulator 12 KV, 5KN, lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
11KV polymeric composite Disc insulator 12 KV, minimum failing load 45 KN lighting impulse 75 KV Positive and 80 KV negative creepage distance 320 mm.
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 32X3 mm in HT Lines
Painting of 8 mtr ST poles including crossarms/clamps with one coat of Red oxide Paint
Painting of 8 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Dismentalling and re-erection of Existing poles 8 mtr long ST
Dismentalling and re-erection of GI Channel X-arm including clamps and braces
Dismentalling and re-erection of 30 mm Sq. ACSR Conductor
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .