Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹31.7 L+₹53,216 (1.71%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹31.8 L+₹60,035.50 (1.92%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹31.9 L+₹70,572.50 (2.26%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹32.9 L+₹1.7 L (5.47%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹30.5 L
EMD Value
₹61,000
Closing Date
21 Jun 2021, 6:00 pmClosed
GE AF Bamrauli
GE AF Bamrauli
REAPIR TO ROOF TREATMENT LEAKAGE SEEPAGE TO TOILET AND CLEANING OF WATER TANK IN SOUTH CAMP MAP TEACHER COLONY AND 4 AFSR UNDER AGE BR II AT AF STN BAMRAULI
2021_MES_445071_1
8653/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bamrauli
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
GE AF Bamrauli
₹61,000
Yes
26 Jun 2021
22 May 2021
22 Jun 2021
22 May 2021
21 Jun 2021
14 Jun 2021
Amount
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down cement plaster or cement lime plaster of any description including racking out joints, hacking for key , scrubbing down with water etc and prepare to receive new plaster complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars etc from parapet etc and removal unserviceable brick/brick bats complete all as specified and directed.
M&L for brick work with sub class 'B' bricks using old size bricks, straight or curved on plan exceeding 6 M mean radius built in CM 1:6 as in parapets etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces or brick work or concrete surfaces, finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces or brick work or concrete surfaces finished even and smooth without using extra cement and mixed with water proofing compound @ 200ml per 50 Kg weight of cement (or) as per manufacturer’s instructions complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface of Chajja, roof projection & slab etc ceiling surfaces finished even and smooth without using extra cement including taking down old ceiling plaster height upto 7 to 8 mtr etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:3 on fair faces of brick work or concrete ceiling surfaces with chicken mesh finished even and smooth without using extra cement in two layer including taking down old ceiling plaster etc complete all as specified and directed.
M&L for preparing of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of cement base primer complete all as specified and directed.
M&L for preparing newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Demolition of Mud/mud puska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed.
Dismantling of brick tiles laid bedded and pointed in any mortar or brick tiles on roof , floors, channels, kerbs, aprons etc, cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded stone aggregate) as in roof padding, benching existing roof slab to slope as per existing or as directed including finished surface even and smooth without using extra cement complete all as specified and directed.
M&L for 10mm thick screed bed in cement mortar 1:4 over concrete surfaces of roof mixed with @ 200ml liquid water proofing compound by 50Kg weight of cement (or) as per manufacturer’s instructions including finishing surfaces even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound will be measured and paid separately
M&L for cleaning the roof surface from dust /dirt and any other foreign materials and applying a coat of bituminous primer @ 0.30 liters per square meter uniformly after the surfaces fully dried complete all as specified and directed.
M&L for applying a coat of hot blown bitumen of grade 85/25 conforming to IS 702 over primed surface of roof slab @ 1.20 Kg/Sqm complete all as specified and directed.
M & L for APP based polymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Weight not less than 150gms/Sqm or as per IS), laid over hot bitumen surface by torched application with the strict supervision of manufacturers technical supervisor. Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer’s instructions and work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer complete all as specified and directed.
M&L for brick tiles 40mm thick over roof treatment, laid over and including 15mm thick screed be in cement mortar 1:6 mixed with and including polymer based liquid water proofing compound/additive @ 200ml liquid water proofing compound by 50Kg weight of cement and joints of brick tiles shall be filled with cement mortar 1:4 mix with and including 5% crude oil complete all as specified and directed.
All as per Sl Item No 19 above but except tiles. Note :- The unit rate quoted is deemed to be inclusive of necessary cleaning, removing mortar, segregation, stacking etc for the tiles obtained out of dismantling.
M&L for two coats of aluminium paint on APP based polymeric water proofing membrane including preparation of surfaces of roof etc complete all as specified and directed.
M&L for cutting out cracks to V section in existing roofs or terrace, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand (1:1) (by weight) complete all as specified and directed.
Supply only liquid integral water proofing compound complete all as specified and directed. Make: Dr Fixit Pidiproof LW+
M&L for plain cement concrete 1:2:4, type B-1 (Using 20mm graded stone aggregate) as in cills, benching and other similar bands, plinth courses, parapets, coping bed plates and the like including weathering, slightly rounded or chamfered angles and throating finishing surface even and smooth including use and waste of form work complete all as specified and directed.
S&F in repairs stack clamps for 110 mm bore of pipe made out of 50mmx5mm flat iron and 16 mm dia round iron stays including bolts and nuts and securing ends of stay to wall or roof etc complete all as specified and directed.
S&F in repairs 0.63 mm thick plain galvanised sheeting fixed on crumple joints fixed with screw on wall/ roof as required complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc and hoisting if required reconnecting and re-fixing in position exceeding 250 ltr not exceeding 500 ltr capacity etc complete all as specified and directed.
Demolition of RCC platform made for 500/1000 ltr capacity water tank of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of water storage tank of of 500 litres capacity all as specified and directed.
S & F 500 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical/vertical with closed top) ISI embossed hoisted and fixed in position complete all as specified and directed.
S & F in repairs 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer,white colour (Cylindrical/vertical with closed top) ISI embossed hoisted and fixed in position including taking down old tank complete all as specified and directed.
S&F 20mm dia ball valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed.
S&F in repairs 20mm dia ball valves high pressure of with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe etc complete all as specified and directed.
S&F in repairs 20mm dia Gun-metal, globe or gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 25mm dia Gun-metal, globe or gate valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Taking up or down steel water tubing galvanised 15 mm dia complete all as specified and directed.
Taking up or down steel water tubing galvanised 20 mm dia complete all as specified and directed.
Taking up or down steel water tubing galvanised 25 mm dia complete all as specified and directed.
S&F 15mm dia medium grade galvanized water tubing with all necessary fittings and fixed to walls complete all as specified and directed.
S&F 20mm dia medium grade galvanized water tubing with all necessary fittings and fixed to walls complete all as specified and directed.
S&F 25mm dia medium grade galvanized water tubing with all necessary fittings and fixed to walls complete all as specified and directed.
Re-fixing old GI steel tubing 15mm bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
Re-fixing old GI steel tubing 20mm bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
Re-fixing old GI steel tubing 25mm bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
S & F in repairs PVC water storage tank cover suitable for 500 Ltr to 1000 Ltr capacity matching with existing PVC tank cover at the site complete all as specified and directed
Cleaning of overhead tank by removing all scale and dirt etc from RCC/PVC tank from mouth of circulating pipe etc to the entire satisfaction of engineer in charge ( Capacity exceeding 250 ltr but not exceeding 500 Ltr ) including writing date of cleaning of each tank complete all as specified and directed
All as per Sl Item No. 46 but exceeding 500 Ltr but not exceeding 1000 Ltr capacity complete all as specified and directed.
S&F in repairs ball valve of 25mm dia high pressure of PTMT ( Minimum weight 455 grams) with epoxy coated aluminium rod and high density plastic ball screw for iron pipe and fixed complete all as specified and directed.
M&L for water proofing treatment for existing sunken portion/floor by complete demolition of existing leakage sunken portion area exceeding 1 Sqm but not exceeding 1.5 Sqm and cleaning the surface and applying cement slurry and 10mm thick cement plaster in CM 1:3 mixing with liquid water proofing compound after surface is fully dried, cleaned free from dust and painting with a coat of bituminous primer@ 0.30 liter / Sqm, after priming the entire surface, applying with hot blown bitumen grade 85/25 conforming to IS 702 @ 1.20Kg / Sqm, over hot bitumen, providing polymeric water proofing membrane consisting of 90 to 100 micron thick central core of HMHDPE film with standard weight not less than 3Kg/Sqm provide with 100mm side lap/end lap after that fixing P trap and filling sunken portion with PCC 1:5:10 type E-2 (Using 40 mm graded stone aggregate) appox 30cm high and PCC 1:2:4 type B-1 (Using 20mm graded stone aggregate) including demolition complete all as specified and directed. Note : The unit rate quoted is deemed to be inclusive of testing of treatment as directed by Engineer-in-Charge.
M&L for taking down cement plaster including tile etc and removing the material out side MD land.& hacking out and racking out the joints with the wire brush to dry and apply one coat of URP of Dr. Fixit and cement in ratio 1:1 @ 1liter per Sqm and after the drying of this process applying two coats of pidifin2K @ 1 liter per Sqm on each coat minimium 4 hour gap is required to be maintained and 15 mm thick rendering in CM 1:4 in roof/ wall complete including finished even & smooth without using extra cement complete all as specified and directed. Make of chemical Dr.Fixit. Note: Guarantee for chemical from the Dr Fixit shall be submitted by contractor. (ii) Work shall be executed by authorised technician/representative of Dr. Fixit
Dismantling floor hearth or wall tilling including cement mortar bedding , removing unserviceable tiles and rubbish off the premises for minor repair to floor tiles/ nahani traps / concealed stop cock and GI tubing in wall etc in patches complete all as specified and directed
S&F non skid ceramic coloured tiles (Premium quality) 300mmx300mmx 7 to 8mm thick in floors set and jointed less neat cement slurry and pointed in coloured cement to match with the colour of tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
S&F glazed ceramic coloured/ designer tiles including highlighter on vertical surface of size 300x450x 7to 8mm thick set and jointed with cement slurry and pointing in white cement to match with the colour of tiles laid over and including 10mm thick backing in cement mortar 1:4 in skirting / dado complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repairs PVC (SWR) 75mm bore pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) Junction single (Single T) equal or unequal with access door complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) Junction single (Single T) equal or unequal complete all as specified and directed.
S&F in repairs 75 mm dia outlet PVC (SWR) floor trap with stainless steel grating including jointing to waste pipe in run led joint complete all as specified and directed.
S&F in repairs 110 mm dia PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs vitreous china squatting pan Orissa Pattern size 580x440mm white with integral foot rest excluding flushing cistern and flush pipe and including 110mm dia 'P' or 'S' trap and connecting piece complete all as specified and directed.
S&F in repairs 10 litres capacity PVC valve less, symphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including bracket complete all as specified and directed.
S&F in repairs 15 mm bore stop valve ISI marked, cast copper alloy, screwed down, high pressure, chromium plated, fancy type handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 15 mm dia bib tap, chromium plated, cast copper alloy with fancy type handle screwed down, screwed for iron pipe complete all as specified and directed.
S&F in repairs PVC connection 450 mm long with brass coupling on both end suitable for 15 mm bore of pipe complete all as specified and directed.
M&L for flush pointing in cement mortar 1:3 on roof tiles including racking out joints etc complete all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
HIMANSHU TRADERS
Mohit Enterprises
M/S SWASTIK BUILDERS
M/S Shivam Industries
MOHAMMAD RIZWAN CONTRACTOR
M/S SURISONS
FRIENDS N FRIENDS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .