| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC AT PO DERA COLLIERY TALCHER DIST ANGUL ODISHA PIN 759103 | ANUGUL | ODISHA | 759103 | L1 | Accepted-AOC AOC AWARDED | |
| 2 | L2₹47.2 L+₹1.2 L (2.55%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED TENDERER | |
| 3 | L3₹47.2 L+₹1.2 L (2.56%)Rejected-Finance 12 L I G PRITAM NAGAR PRAYAGRAJ U P PIN 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED TENDERER | |
| 4 | L4₹48.8 L+₹2.8 L (6.05%)Rejected-Finance 83 5M 1 SHIV GANGA PURAM YADAVPUR ROAD UMARPUR NEEWAN PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance OTHER THAN LOWEST QUOTED TENDERER | |
| 5 | Rejected-Technical | - | Rejected-Technical Not admitted due to no enlisted in cat b(i) |
Tender Value
Refer Docs
EMD Value
₹97,500
Closing Date
24 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST NEW CANTT ALLAHABAD
PROVN OF CERTAIN SPL REPAIR AND LBW WORKS UNDER AGE B/R-I AT NEW CANTT ALLAHABAD
2020_MES_381516_2
8931/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹97,500
Yes
22 Jan 2021
9 Nov 2020
26 Nov 2020
9 Nov 2020
24 Nov 2020
17 Nov 2020
60 days
Amount
Demolition of brick work built in cement mortar of any description including all quions arches, pillars, etc complete all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks (old size), straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed..
M&L for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed..
M&L for preparation of newly plastered surfaces of wall and applying two coats of white wash complete all as specified and directed..
Dismantaling of ACP wall panneling boards (of any type & thickness) , including any type of fillets complete all as specified and directed..
S&F aluminium composite panel sheet 3 mm thick fixed with and including necessary backing aluminium tubes, joints of panel should be filled with silicon filling material and all panel will be fixed with screw, as in wall panelling ,ceilling or vertical surface complete all as specified and directed.. (Make :-GURIND/ALSTRONG or as approved)
Dismantaling of gypsum wall or ceiling boards (of any type & thickness) , including any type of GI grid as in POP ceiling complete all as specified and directed..
M&L for providing and fixing 10mm thick plaster of paris ceiling (Gypsum Anhydrous) to flat surface/curved surface over metal frame work and reinforced with GI wire mesh as approved complete all as specified and directed at site by Engineer-in-charge.
S&F for 100 mm wide plaster of paris corner beat / cornice for ceiling as per GE direction complete all as specified and directed..
M&L for preparation of newly decorated surface of ceiling and applying two coats of internal plastic emulsion paint coloured or white or tinted with one coat of internal base primer with and including 2 mm thick white cement wall care putty complete all as specified and directed..
Dismantling timber framed filled rails, post, rafters purlins, etc under 40 sqm in section complete all as specified and directed..
Dismantling of boarding, any description, fixed in any position with screw/nails complete all as specified and directed..
S&F 12mm thick wooden flooring with backing fillets and end packing edge fixed with necessary and required items as per manufacturer instruction and as per GE direction complete all as specified and directed.. Make:- Action Tessa / Green prelam or as approved.
M&L for mild steel work in square or rectangular hollow section used as in purlins, rafter, column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc. using induction butt welded tubes conforming to IS-4923-1997 grade Yst-310 complete all as specified and directed..
M&L for preparation of old decorated surface of wall and applying two coats of internal plastic emulsion paint white or tinted on wall with one coat of internal base primer with and including 2 mm thick white cement wall care putty complete all as specified and directed..
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n exc 1.50 each complete all as specified and directed..
Taking down chowkhats with shutter (without taking off shutters from the frame) exc 1.5 Sqm but not exc 4.0 Sqm each and removing from site complete all as specified and directed..
S&F 12 mm thick frosted type acid itching toughened or tempered glass door / partition with thermal and chemical treated with heavy strength of fine polished edge.It made from annealed glass via a thermal tempering process and toughening process, with and including necessary glass holes, fitting,fixtures & clits etc complete all as specified and directed. by manufacture instruction and as per GE / Engr-in-charge direction.
S&F double action floor spring hydraulically regulated made up for minimum 12 mm thich toughened glass door of aluminium alloy foundation box,main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed..
S&F 600mm long and 40 mm dia stainless steel door handle for glass door with all fixing arrangement complete all as specified and directed..
Excavation in trenches n.exc 1.5 m width and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits , manholes, pier holes etc or for laying of electric cables etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and directed....
Excavation over areas n. exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed....
Returning filling in ,including spreading ,levelling,watering and well ramming in layers n exc 25 cm soft/ loose soil complete all as specified and directed....
Removing of surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc.1.5 mtr above starting point complete all as specified and directed.
Removing excavated material exc 250 m but n exc 500 m distance and depositing as directed at a level n exc 1.5 m above the starting point complete all as specified and directed....
M&L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed..
M&L for PCC 1:3:6 type C2, using 40mm graded stone aggregate, as in foundation filing,sub base of floor complete all as specified and directed...
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed..
Form work to soffits of suspended slabs such as roof slab etc. n.exc. 200mm thick for rough finished surfaces of concrete complete all as specified and directed..
Form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed..
S&F TMT bars of 10mm dia and over in reinforcement cut to length bent to shape required including cranking bending and binding with mild steel annealed wire not less than 0.90 mm dia or securing with clips and as straight in groves complete all as specified and directed..
M&L for brick work with fly ash bricks (old size), straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed....
M&L for PCC 1:2:4 type B1, using 20mm graded stone aggregate, as in coping,surface channel etc in drainage includin all necessary form work etc as required complete all as specified and directed....
S&F 110 mm bore PVC (SWR) pipes as in weep hole complete all as specified and directed..
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed....
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto etc.complete all as specified and directed....
S&F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 etc.complete all as specified and directed....
M&L for E-board tiles ceiling on GI powder coated channel/Tee/Grid of make (Armstrong or equivalent) frame work with the following specifiecation including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type B0/Cement mortar 1:3 complete all as specified and directed. with following:- (a) M&L Plugging to wall around the rooms & supplying & fixing GI powder coated angle of make (Armstrong or equivalent) of size 25x25mm. (b) S&F 1.60 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling with dash free fasteners. (c) S&F GI powder coated tee as in main & cross members at 595 mm centre to centre supported suspenders alongwith adjustable clamp to maintain level. (d) S&F E-board ceiling tiles of size 595 mm x 595mm x 4mm thickness, confirming to relevant IS in squares of GI powder coated tee with clips made to shape, shade and pattern of tiles shall be as approved by GE.
S&F Aluminimum anodised curtain section as approved with metal curtain hooks silver rustproof stainless steel plated nickel hooks heavy duty spacing not more than 75mm fixed to aluminium posts section as necessary and approved including all connecting fitting/fixtures complete all as specified and directed.... (Make Jindal/ Hindalco or as approved).
S&F Aluminimum anodised partition section framed with single groove and double groove of size as approved fixed to aluminimum section posts to hold 6.00mm thick frosted glass pan, area of each pan not exc 1.50 Sqm with rubber beading aluminium cliping patti and all necessary connected fitting and fixtures complete all as specified and directed.... (Note - rate should be quoted including rubber beading and aluminimum beading/clilp/patti, but excluding glass pan).
S&F aluminium anodised glazed window hung type with 2/3 track system using 1.50mm thick aluminium section having frame of size 62.3 x 44.45mm, styles & rails section of size 44.45 x 44.45mm of Make - Jindal/Hindalco including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodized aluminium fittings such as 02 Nos 75mm long aluminium snap beading screws, aanodized alouminium fittings such as 02 Nos 75 mm long aluminium hinges C-21 type, 01 no 150mm long aluminium tower bolt and 01 nos 100mm aluminium handle including glazed with 5mm thick tinted glass (Make: Modi Guard/Saint Gobain) and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm wherever required complete all as specified and directed..
S&F solid prelam moulded PVC double door frame of size 50mm x 95mm made single side prelam PVC sheet used instead of plain colour PVC sheet as approved complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed..
S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed..
S&F 100mm long Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge , pin anodized complete all as specified and directed.
S&F 100mm long aluminium alloy handle cast type anodized complete all as specified and directed.
S&F 6.00 mm thick frosted glass pan fixed to aluminimum frame area of each pan not exceeding 1.50 Sqm each complete all as specified and directed.
Dismantling floor ,wall and hearth tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for plain cement concrete 25mm thick type B-0 1:2:4 (12.5mm graded stone aggregate) as floor finish complete all as specified and directed.
M&L for non skid ceramic colour tiles 7-8mm thick (square/rectangular) area of each tiles exc 0.06 sqm but n exc 0.11 sqm , in floors etc set and jointed in neat cement slurry & pointed in white or colouir cement to match the surfaces over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for coloured glazed ceramic tiles as approved of size 600 x 300x 7to 10 mm thick in vertical surfaces set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering/bakcing coat in cement mortar 1:4 complete all as specified and directed.
M&L for Vitrified Ceramic coloured tiles light shed 10 mm thick (square/rectangular) polished, area of each tile 600x600x 10mm thick in floors with spacer and fill with sealing compound etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 over brick or concrete surfaces finishing the surfaces even and smooth without using extra cement including necessary scaffolding etc complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even including all necessary scaffolding etc for work upto any height n. exc 6.00 mtrs complete all as specified and directed.
Taking up or down steel tubing & connections 20mm bore including cleaning for re fixing or removal to store complete all as specified and directed.
Taking up or down steel tubing & connections 15mm bore including cleaning for re fixing or removal to store complete all as specified and directed.
M&L for 15 mm dia steel tube medium grade galvanized with all fittings, concelled to wall, ceiling or laid in floor etc complete all as specified and directed.
M&L for 20 mm dia steel tube medium grade, galvanised with all fittings, concealed to wall, ceiling or laid in floor etc complete all as specified and directed.
S&F in repair Chromium plated brass angle valve with half/quarter turn type for 15mm bore pipe, fixed in repairs complete all as specified and directed.
S&F brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed to WHB, for 15mm bore complete all as specified and directed.
S&F brass chromium plated tubular towel rail 20mm dia D type 60mm long between flangs including two bricket of each rail complete all as specified and directed.
S&F in repair vitreous china wash bashin, snow white flat back with pedestal of size 630mm x 450mm oval shape including brackets including cutting for and pinning in ends of brackets in CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed.
S&F in repair Gun-metal,globe or gate valves 25mm dia, ith iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 100 mm dia C.P grating with or without hole complete all as specified and directed.
S&F PVC connection 15 mm size with P.T.M.T nuts of length 600mm complete all as specified and directed.
S&F waste coupling of PTMT (half or full threaded) (minimum weight 32mm- 45gms/40mm-60gms of 32mm dia for WHB complete all as specified and directed.
M&L for 75mm iron floor trap with grating incl jointing with solvent cement etc as fixing in repair complete all as specified and directed.
S&F in repair Soap dish, Vitreous China white, approximate size 160 x 160x 90 mm complete all as specified and directed.
M&L for preparation new plastered surfaces and applying three coats of white wash on Ceiling complete all as specified and directed.
M&L for preparing new plaster surfaces of wall including cornices and applying two coat of oil bound distemper complete all as specified and directed.
M&L for prepration of newly plastered wall surfaces and applying two coat of Oil Bound distemper over a coat of 3mm thick wall care putty complete all as specified and directed.
S&F in repairs C P bib cock long body half/full turn (concealed type) including flange screwed down for iron pipe 15 mm bore complete all as specified and directed.
S&F in repair vitreous china urinals bowl, flat back large of size 710 x 300 x 600 mm white with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement including Urinal spreader complete all as specified and directed. Make - Cera Cat No 5001 or equivalent as approved
S&F in repair low level PVC flushing cistern 10 Ltrs capacity valve less, symphonic action type white with inlet ball valve, float and handle including bracket complete with PVC long bend complete all as specified and directed.
S&F in repair viterous china wash down water closet pan ( pedestal pattern) white and trap including connection to drain (or outgoing pibe) and to flushing pipe, antisyphonage pipe and PVC sheet cover, complete all as specified and directed.
S&F in repair two way bib tap with flange 15mm bore, fancy type, quarter turn, cast copper alloy, chromium plated with long shank and cup screwed down, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair health faucet with 1m long flexible CP pipe with wall hook complete with all fittings complete all as specified and directed.
S&F in repair brass chromium plated shower rose 65 to 90 mm size , shower Arm with swivel joints complete all as specified and directed.
S&F in repair CP stop valve 15 mm bore, fancy type cromimum plated with long shank and cup (concealed type), high pressure crutch or butter fly handle screwed both ends screwed for iron pipe or for unions complete all as specified and directed.
S&F flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern to pedestal pan, including all joints complete all as specified and directed.
Taking down carefully existing old/worn out point wiring with wooden batten (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light /sketch/bulk head fittings etc including making good to the disturbed surfaces of walls complete all as specified and directed.
M&L for point wiring (concealed type) complete with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm( 22/0.30 or 30/0.25), 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface) and supply and fixing PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes using new MS sunk terminal boxes of thickness not less 1.22 mm, new 3 mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and treated surface with existing white/colour wash/distemper etc to match with existing surface complete all as specified and directed. and suitable for the following: -
One light point or one fan point controlled by one, 1- way switch
One 3/5 pin socket outlet, 6 Amp on the same board with other switches
One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane. Note : Socket Outlet point provided beside to switch board on same wall will be measured as below the switch board
One 3/5 pin socket outlet, 6 Amp on “independent board”
All as per item No. 85 above but point wiring using 2.5 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 16 amps “ independent board”.
All as per item No. 85 above but point wiring using 4.0 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet, suitable for AC point “ independent board”.
S&F ISI marked switch piano flush button type, single pole, one way, 6 Amps complete all as specified and directed.
S&F socket out let 6 pin, 6 Amps flush type complete all as specified and directed.
S&F switch socket combination multipurpose 2 in 1, 6 pin, 6 and 16 Amp complete all as specified and directed.
S&F ceiling rose 3 pin/PVC/ polycarbonate complete all as specified and directed.
S&F batten/angle holder with colour ring for light point complete all as specified and directed.
S&F (in replacement of) surface & wall mounted light fitting in CRCA powder coated white housing complete with prewired suitable for ONE T8 LED tube along with supply and fixing ONE number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make - Philips/Havells as approved
S&F of existing worn out ceiling light with recessed mounted LED light luminaries of size 595 mm x 595 mm an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36 Watt, Colour Temp - 3000 to 5700 K, Lumen out put- 4200-4400 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. LED Light Model -RC380B LED36S-6500 G4 L60 W60 PSD OD of Make - Philipsr as approved.
S&F in replacement of existing worn out DB with single phase & neutral MCB Distribution Box of 8 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed.
S&F of MS terminal box fixed for geyser/AC by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket of current rating 20 amps complete with fixing one single pole MCB , 'C' series of current rating 25 amp including cutting, chasing in wall to recess the same and making good complete all as specified and directed.
S&F MCB with high rating MCB Triple pole, 100 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T as approved.
S&F in replacement of MCB double pole , 40 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
S&F in replacement of worn out MCB with MCB SP, 06 to 32 Amps 240 volts, 'C' Series, ISI marked and conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
S&F spot light 5 watt of 90 mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make - Havells Cat pt No: ORBITDLR5WLED854S its equivalent model in Philips/Crompton as approved.
S&F energy efficient flexible LED strip uses high brightness SMD LED as the light source for indoor application, suitable for cove lighting, long life, aesthetically designed with good symmetrical light distribution including connection with PVC insulated & sheathed stranded copper conductor wire of 1.5 Sqmm complete all as specified & directed. (Model No:- FLEXISTRIP5MIP2024V/2ALED865S make of Havells or its equivalent in Philips/Mepro or as specified and directed by Engr-in- charge.
S&F ceiling fan of size 1200 mm sweep, conforming to IS : 374, 5 Star rated, nominal wattage -50 Watt (± 5 %) , speed - 320 to 380 RPM, Air dilivery - 215 to 225 Cu Mtr/Min including accessories complete suitable for operating voltage 230 Volt AC connecting with FR PVC insulated & PVC sheathed round flexible copper conductor wire of size not less than 23/0.0076 in three core of length not more than 0.5 Mtr including taking down the existing old ceiling fan ( antique model ) and depositing the same to E/M store yard complete in all respect as specified and directed. Model - ES 50 Premium of make - Havells, or Model - Aura Plus of make - Crompton, or Model - Joan of make Orient, or its equivalent model in Khaitan/Usha/Almonard as approved
Supply, Installation, Testing and Commissioning of, wall mounted , Air Cooled, High wall Split Units (Indoor & Outdoor), Air Conditioner, electric driven, Inverter Rotary type compressor, single phase of capacity 1.5 TR, 5 star rating, electric driven 1 phase, 230 volt, complete with cordless remote control unit and mounting arrangment for indoor and outdoor unit complete all as specified and directed. (NOTES : 1. AC refrigerant should be Non CFC. 2. Copper pipes beyond the standard length supplied by manufacturer alongwith the ACs shall be measured and paid seperately) (MAKE :Carrier/ BlueStar/ Voltas/ LG or equivalent model in the approved manufacturers listed in particular specifications)
S&F in replacement down rod made by mild steel 'light grade' 15mm dia pipe of length 3.5 Mtr to 4.5 Mtr with making split holes, cut or threads at both end of pipe as required for hanging of C/fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer complete all as specified and directed.
M&L for replacement of sub main wiring with 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire , FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core , 1100 Volts grade along with FRLS PVC insulated unsheathed flexible copper conductor (Multistrands) in green colour as continuous earth wire conforming to IS 694 with latest amendments and ISI marked, drawing in recessed/surface PVC conduct and making incoming / outgoing electric connections by using required size copper lugs / thimbles, making good to disturbed surface to match with existing including removal of existing old complete in all respect as specified and directed.
M&L for replacement of sub main wiring with two run of 6.0 Sqmm or 84/0.30 FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core , 1100 Volts grade and one run of 6.0 Sqmm FR PVC insulated unsheathed (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked, drawing in surface/recessed PVC conduct and connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good to disturbed surface to match with existing including removal of existing old complete in all respect as specified and directed. Note :- Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length.
Cutting & Chasing required on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
Cutting & chasing required not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm bore GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a Cast Iron hinged cover resting over the Cast Iron frame painted with black bitumastic paint which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required.
Supply, fixing & connecting to electrical system & testing of LT distribution panel board CPRI approved make ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 1000x900x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens. (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e)MCCB 4 Pole 200 Amp 415 volt ,36 KA breaking capacity with spreader bothe side, as Incomming cotrol device : 01 Nos.( Make : L&T (AU series) /ABB/Schnieder) (f) MCCB 4 pole 100 Amp 415 volt rating & breaking capacity 25 KA with spreader at bothe side. : 3 Nos ( Make : L&T (AU series) /ABB/Schnieder) (g) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete.
(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens. (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e)MCCB 4 Pole 200 Amp 415 volt ,36 KA breaking capacity with spreader bothe side, as Incomming cotrol device : 01 Nos.( Make : L&T (AU series) /ABB/Schnieder) (f) MCCB 4 pole 100 Amp 415 volt rating & breaking capacity 25 KA with spreader at bothe side. : 3 Nos ( Make : L&T (AU series) /ABB/Schnieder) (g) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete.
S&F Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed.. Make:Indo asian/ Havells/Hager as approved
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 400 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and directed... by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate ) (i) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 250 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 160 Amp - 01 No (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 125 Amp - 01 No (iv) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 01 No (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB, MCB & Contactor: L&T, Hagger, Siemens,
S&F MCB with high rating MCCB pole, 160 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T or as approved.
Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for Following size:(a) 50 Sq mm 3.5 core
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed.
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing inreplacement of cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of outdoor type cubical panel board, doule door suitable for 3 phase, 4 wire, 415V, 50 Hz and CPRI approved manufacturer factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity 1200 Amps of the incomer MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT Panel is deemed to be included in the quoted rate). (i) ACB, 4 pole 50 KA with microprocessor release IPR E+ 415V, 630 Amp - 01 No. (ii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 200 Amp - 02 No (iii) MCCB 4, pole 35 KA with adjustable thermal setting, 415V, 125 Amp - 02 No (iv) MCCB 4, pole 25 KA with adjustable thermal setting, 415V, 63 Amp - 02 No (v) Digital Volt meter 0-500 volts (vi) Ammeter 0-500 amps with suitable size of Cts (vii) All connections to be done through suitable size PVC insulated copper cables (viii) LED RYB indicator - 01 Set Make of MCCB, MCB & Contactor: L&T, Havells, Siemens, Sneider
M&L for earthing in replacement of with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & directed by Engr-in-Charge.
Demolition cement concrete (un reinforced) in ground floor and paving n.exc 15 cm thickness (Below or above ground level) all as specified.
Hi-Tech Constructions
M/s SINGH CONTRACTOR WORKS
chauhan construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .