Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LQualified 6 JAIPUR SATI JI KI BAGICHI MOTI DOONGRI ROAD VILLAGE TOWN JAIPUR CITY JAIPUR JAIPUR RAJASTHAN 302004 INDIA | JAIPUR | RAJASTHAN | 302004 | L1 | Qualified MSE, MII, Category: General | |
| 2 | L2₹5.0 L+₹45,869.40 (10.1%)Qualified 10 PANCHWATI COLONY JDA SCHEME GURJAR KI THADI JAIPUR RAJASTHAN 302019 | JAIPUR | RAJASTHAN | 302019 | L2 | Qualified MSE, MII, Category: General | |
| 3 | Disqualified 368 HIRAN MAGRI SECTOR NO 3 UDAIPUR UDAIPUR UDAIPUR RAJASTHAN 313002 | UDAIPUR | RAJASTHAN | 313002 | - | Disqualified MSE, MII, Category: General |
Tender Value
Refer Docs
EMD Value
₹11,432
Closing Date
2 Dec 2024, 3:00 pmClosed
Upto 55 KVA DEA Sets Capacity along with all accessories
Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting
Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting
Installation
Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation
Installation
Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation
Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model
Replacement of Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity
Replacement of Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity
Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity
Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity
Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity
Replacement of Front oil Seal
Crank Shaft in existing DEA sets up to 20 KVA Capacity
Replacement of Back oil Seal
Crank Shaft in existing DEA sets up to 20 KVA Capacity
Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity
Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Front oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Back oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Repairing of Cylinder Head
One Job for Each Head
Repairing of Crank Shaft Up to 20 KVA DEA sets
Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets
Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA
Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA
Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator
Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator
Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator
Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator
Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator
Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator
Replacement or Repairing of faulty AVR for Bid Details 2/72 existing faulty Alternator up to 55 KVA Capacity
Replacement or Repairing of faulty Power Diode for Rotating Rectifier Assembly for existing faulty Alternator up to 55 KVA Capacity
Replacement or Repairing of faulty Bearing Suitable for above 20 KVA Alternator up to 55 KVA Capacity
Providing of 2 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable
Providing of 4 Core 16 Sqmm PVC insulated and PVC sheathed Aluminum conductor armored cable
Laying and fixing on wall Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable
Laying of direct in ground Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable
Laying in the existing RCC or HUMEor METAL pipe Upto 35 sq. mm PVC insulated and PVC sheathed or XLPE power cable
Supplying and making end termination with brass compression gland and aluminum lugs for 2 X 10 sq. mm
Supplying and making end termination with brass compression gland and aluminum lugs for 4 X 16 sq. mm
Providing and fixing 6 SWG dia G.I. wire
SITC of 32 amps four pole ON Load Side Handle operated change over switch
SITC of 63 amps 2 Pole ON Load Side Handle operated change over switch
SITC of 63 amps four pole ON Load Side Handle operated change over switch
Providing and Fixing 63 A TPN Disconnector Fuse Switch Unit in sheet steel enclosure
Repairing of Fuel Injection Pump
7115015
GEM/2024/B/5587208
Two Packet Bid
Visit charges to attend fault of DEA Set on call basis
180 days
305004, BSNL Electrical Sub Division Ajmer, First Floor, Telephone Exchange Vaishali Nagar Ajmer -
Total value wise evaluation
BOQ
7 documents required · 7 mandatory
3 yrs
₹3
80%
₹11,432
9 Jan 2025
8 Nov 2024
2 Dec 2024
Call Basis Maintenance of Diesel Engine Alternator Sets in
Upto 55 KVA DEA Sets Capacity along with all accessories
Unloading of existing DEA sets Up to 20 KVA Capacity from Loading Vehicle to Place of Shifting
Unloading of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity from Loading Vehicle to Place of Shifting
Testing and Commissioning of existing DEA sets up to 20 KVA Capacity on existing foundation
Testing and Commissioning of existing DEA sets More Than 20 KVA and Upto 55 KVA Capacity on existing foundation
Labour Charges for Top Overhauling of existing DEA Sets up to 20 KVA Capacity of various Make and Model
Replacement of Liner assembly with rubber ring in existing DEA sets up to 20 KVA Capacity
Replacement of Piston Set without Piston Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of Piston Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of Set of Gasket including Head Gasket in existing DEA sets up to 20 KVA Capacity
Replacement of O Ring Set in existing DEA sets up to 20 KVA Capacity
Replacement of CR Bearing in existing DEA sets up to 20 KVA Capacity
Replacement of Main Bearing in existing DEA sets up to 20 KVA Capacity
Replacement of Oil Pressure Gauge in existing DEA sets up to 20 KVA Capacity
Replacement of Front oil Seal
Crank Shaft in existing DEA sets up to 20 KVA Capacity
Replacement of Back oil Seal
Labour Charges for Top Overhauling of existing more than 20 KVA and upto 55 KVA Capacity
Replacement of Liner assembly with rubber ring in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Piston Set without Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Piston Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Set of Gasket including Head Gasket in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of O Ring Set in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of CR Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Main Bearing in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Oil Pressure Gauge in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Front oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Replacement of Back oil Seal Crank Shaft in existing DEA set more than 20 KVA and upto 55 KVA of Capacity
Repairing of Cylinder Head
One Job for Each Head
Repairing of Crank Shaft Up to 20 KVA DEA sets
Repairing of Crank Shaft More Than 20 KVA and Upto 55 KVA DEA Sets
Transportation Charges for Alternator Upto 50 Km of various capacity up to 55 KVA
Transportation Charges for Alternator More than 51 to 100 Km of various capacity up to 55 KVA
Rewinding of Main Stator winding of Alternator Capacity up to 20 KVA of existing faulty Alternator
Rewinding of Main Rotor winding of Alternator Capacity up to 20 KVA of existing faulty Alternator
Rewinding of Main Stator winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator
Rewinding of Main Rotor winding of Alternator Capacity more than 20 KVA and Up to 50 or 55 KVA of existing faulty Alternator
Rewinding of Exciter Stator winding of Alternator Capacity up to 55 KVA of existing faulty Alternator
Rewinding of Exciter Rotor winding of Alternator Capacity up to 55 KVA of existing faulty Alternator
Replacement or Repairing of faulty AVR for
Repairing of Diesel Generator
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_7115015.pdf
GEM_BID
ATC_f6be46e2-1b0d-4329-92541731051291272_Arjunlal02.pdf
OTHER
list-of-categories-where-trials-are-allowed_1712126171.pdf
OTHER
gtc.pdf
OTHER
technical_spec_2024-11-08-12-46-09_6d53bec4144e88bda0d9ffd8ffd07225.pdf
BOQ
boq3_2024-11-08-12-46-09_ca69acc313eb98dbb63e7ae6ab0cef00.csv.pdf
BOQ
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .