Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHEMBER DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 88 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹1.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹5.5 L (3.85%)Admitted-Finance | ₹1.5 Cr+₹5.5 L (3.85%) | L2 | Admitted-Finance |
| 3 | L3₹1.6 Cr+₹14.2 L (9.90%)Admitted-Finance | ₹1.6 Cr+₹14.2 L (9.90%) | L3 | Admitted-Finance |
| 4 | L4₹1.8 Cr+₹32.7 L (22.8%)Admitted-Finance C 2 MADEL INDUSTRIAL ESTATE NEAR VIRWANI INDUSTRIAL ESTATE ROAD NO 2 GOREGAON E MUMBAI 400063 | MUMBAI | MUMBAI | MAHARASHTRA | 400063 | ₹1.8 Cr+₹32.7 L (22.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TECHNOCRATS SECURITY SYSTEMS PVT LTD L4 | RCK Electrical Enterprises L3 | Arathi Electricals L1 | GROMOS INDIA L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Routine, Preventive and Breakdown Maintenance of 415V MV ACB Switchgear Panel as per TSS-1 | 2 | Each | 20,250 ₹40,500 | 1,50,000 ₹3,00,000 | 1,00,000 ₹2,00,000 | 16,000 ₹32,000 Lowest |
| 2.00 | Routine, Preventive and Breakdown Maintenance of PCC/MCC Panels less than or equal to 15 feeders as per TSS-2 | 124 | Each | 10,125 ₹12,55,500 | 6,000 ₹7,44,000 | 46,000 ₹57,04,000 | 1,800 ₹2,23,200 Lowest |
| 3.00 | Routine, Preventive and Breakdown Maintenance of PCC/MCC Panels more than 15 feeders as per TSS-3 | 64 | Each | 10,125 ₹6,48,000 | 10,000 ₹6,40,000 | 40,000 ₹25,60,000 | 4,800 ₹3,07,200 Lowest |
| 4.00 | Minor maintenance of PCC/MCC panels as per TSS-4 | 188 | Each | 16,875 ₹31,72,500 | 1,000 ₹1,88,000 Lowest | 5,000 ₹9,40,000 | 4,000 ₹7,52,000 |
| 5.00 | Routine, Preventive and Breakdown Maintenance of Distribution boards as per TSS-5 | 700 | Each | 1,283 ₹8,98,100 Lowest | 1,900 ₹13,30,000 | 3,000 ₹21,00,000 | 3,500 ₹24,50,000 |
| 6.00 | Routine Preventive and Breakdown Maintenance of all types of indoor lighting fixtures as per TSS-6 | 5,700 | Each | 162 ₹9,23,400 | 190 ₹10,83,000 | 150 ₹8,55,000 Lowest | 600 ₹34,20,000 |
| 7.00 | Routine Preventive and Breakdown Maintenance of all type of highbay/medium bay/outdoor lighting fixtures as per TSS-7 | 190 | Each | 338 ₹64,220 | 1,400 ₹2,66,000 | 50 ₹9,500 Lowest | 2,000 ₹3,80,000 |
| 8.00 | Routine Preventive and Breakdown Maintenance of 16A / 6A switch-socket power points as per TSS-8 | 1,978 | Each | 108 ₹2,13,624 Lowest | 230 ₹4,54,940 | 180 ₹3,56,040 | 200 ₹3,95,600 |
| 9.00 | Routine Preventive and Breakdown Maintenance of Metal clad industrial socket power points as per TSS-9 | 360 | Each | 338 ₹1,21,680 | 280 ₹1,00,800 | 220 ₹79,200 | 100 ₹36,000 Lowest |
| 10.00 | Routine Preventive and Breakdown Maintenance of Three phase points in MS box per TSS-10 | 140 | Each | 338 ₹47,320 | 280 ₹39,200 Lowest | 1,600 ₹2,24,000 | 350 ₹49,000 |
Tender Value
₹1.7 Cr
EMD Value
₹3.9 L
Closing Date
25 Jun 2025, 6:00 pmClosed
Chief Engineer and Head, TSD
Chief Engineer and Head, Technical Services Division, BARC, Trombay, Mumbai-400085
Preventive and breakdown maintenance (2 years) of electrical systems for Common Facility Building, New Animal House, AH Service Building, Field House, 5ML tank, Nursery, WTP and TVS area, BARC Trombay, Mumbai 85
2025_BARC_863526_1
BARC/TSD/ET/9/2025-2026
Open Tender
Electrical Works
Item Rate
730 days
BARC, Trombay, Mumbai
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹3.9 L
Conference Room, 2nd FL, TSD
24 Jul 2025
10 Jun 2025
2 Jul 2025
10 Jun 2025
25 Jun 2025
10 Jun 2025
10 Jun 2025 - 25 Jun 2025
18 Jun 2025
Amount
Routine, Preventive and Breakdown Maintenance of 415V MV ACB Switchgear Panel as per TSS-1
Routine, Preventive and Breakdown Maintenance of PCC/MCC Panels less than or equal to 15 feeders as per TSS-2
Routine, Preventive and Breakdown Maintenance of PCC/MCC Panels more than 15 feeders as per TSS-3
Minor maintenance of PCC/MCC panels as per TSS-4
Routine, Preventive and Breakdown Maintenance of Distribution boards as per TSS-5
Routine Preventive and Breakdown Maintenance of all types of indoor lighting fixtures as per TSS-6
Routine Preventive and Breakdown Maintenance of all type of highbay/medium bay/outdoor lighting fixtures as per TSS-7
Routine Preventive and Breakdown Maintenance of 16A / 6A switch-socket power points as per TSS-8
Routine Preventive and Breakdown Maintenance of Metal clad industrial socket power points as per TSS-9
Routine Preventive and Breakdown Maintenance of Three phase points in MS box per TSS-10
Routine Preventive and Breakdown maintenance of earthing stations as per TSS-11
Routine Preventive and Breakdown maintenance of lightning air terminals / arrestors as per TSS-12
Routine Preventive and Breakdown maintenance of Push button stations as per TSS-13
Routine Preventive and Breakdown maintenance of local starter panels as per TSS-14
Routine Preventive and Breakdown maintenance of ceiling/Pedestal/single phase Exhaust fans as per TSS-15
Routine Preventive and Breakdown maintenance of Exhaust fans of highbay areas as per TSS-16
Routine preventive and breakdown maintenance of signage indicators as per TSS-17
Routine Preventive and Breakdown maintenance of Telephone terminal box (TTB) as per TSS-18
Routine Preventive and Breakdown maintenance of Telephone points as per TSS-19
Routine Preventive and Breakdown maintenance of Data points as per TSS-20
Routine preventive and breakdown maintenance of 350 KVA Lighting transformers as per TSS-21
Routine preventive and breakdown maintenance of VFD panel for chilled water / Hotcell system as per TSS-22
Routine preventive and breakdown maintenance of electrically operated two wheeler as per TSS-23
Only Installtion of LT armoured Cables dia 5 mm to 20 mm as per TSS-24
Only Installtion of LT armoured Cables dia 25 mm to 50 mm as per TSS-25
Only Installtion of LT armoured Cables dia 50 mm to 75 mm as per TSS-26
Removal and re-rolling of various size LT cable as per TSS-27
Only installation of SFU/MCCB/OL Relay/Contactor of various rating at site as TSS-28
SITC of Primary lighting point wiring with a switch as per TSS-29
SITC of Looped Secondary lighting point wiring as per TSS-30
SITC of Primary power point wiring with 1 no 6A/16A 5pin combined socket and 16A switch and 1 no of 6A socket and 6A switch in 6/8 module box in casing caping as per TSS-31
SITC of Secondary power point wiring with 1 no 6A/16A 5pin combined socket and 16A switch and 1 no of 6A socket and 6A switch in 6/8 module box to be looped from primary power point in casing caping as per TSS-32
SITC of Looped Secondary power point wiring with 6A/16A combined socket and 16A switch in a 3/4 module box in casing caping as per TSS-33
SITC of Looped secondary power point with a combination of 5 Nos 6/16 A Switch and socket with MCB control in casing caping as per TSS-34
SITC of Primary power point wiring with 20A metal clad socket, top and 1 No. 20A MCB in separate M. S. Box for AC/exhaust fan in casing caping as per TSS-35
SITC of Extension board with 5/15Amps socket and swtich 4nos with 10mtrs cord as per TSS-36
SITC of Cat-6 cable in casing caping as per TSS-37
SITC of End termination of telephone point with RJ-11/RJ 45 socket as per TSS-38
SITC of RJ45/RJ11 socket(1 module) with connector as per TSS-39
SITC of 2.5 sq. mm FRLS wire (R/Y/B/black/green) as per TSS-40
SITC of 4C TRS 2.5 sq. mm cu wire as per TSS-41
SITC of 4Cx4 sq mm copper conductor XLPE cable as perTSS-42
SITC of 4Cx6 sq mm copper conductor XLPE cable as perTSS-43
SITC of 4Cx16 sq. mm Al. conductor XLPE cable as per TSS-44
SITC of Glanding and termination of cables upto 10 sq. mm as per TSS-45
SITC of Glanding and termination of cables 10 sq. mm. to 50 sq. mm as per TSS-46
SITC of Glanding and termination of cables above 70 sq. mm. to 150 sq. mm as per TSS-47
SITC of Glanding and termination of cable 240 sq. mm. and above as per TSS-48
SITC of Straight joint of 10/16/25/70 sq mm armoured Al/Cu conductor cable as per TSS-49
SITC of Straight joint of 300 sq. mm armoured Al conductor cable as per TSS-50
SITC of 10 A SP MCB as per TSS-51
SITC of 20A SP MCB as per TSS-52
SITC of 32/40 A 3P MCB as per TSS-53
SITC of 32A 4 Pole MCB as per TSS-54
SITC of 63A/40A 4P MCB as per TSS-55
SITC of 40 A DP ELCB as per TSS-56
SITC of 63 A DP ELCB as per TSS-57
SITC of 32/40A 2P RCBO as per TSS-58
SITC of 63 A 2P RCBO as per TSS-59
SITC of 32/40/63 A 4P RCBO as per TSS-60
SITC of 20A 2P RCBO in powder coated 4 module MS box as per TSS-61
SITC of 32A 4P RCBO in powder coated 8 module MS box as per TSS-62
SITC of 63A 4P RCBO in powder coated 8 module MS box as per TSS-63
SITC of 63A MCCB in powder coated MS Box as per TSS-64
SITC of 100/125A rated MCCBs in existing PCCs as per TSS-65
SITC of 250A rated MCCBs in existing PCCs as per TSS-66
SITC of 4P 16A MPCB in existing PCC as per TSS-67
SITC of 2P 10A/6A MPCB in powder coated MS enclosure as per TSS-68
SITC of 4P 16A/20A MPCB in powder coated MS enclosure as per TSS-69
SITC of 20 A HRC Fuse(HF/HK/HQ/NH) as per TSS-70
SITC of 32A HRC Fuse(HF/HK/HQ/NH) as per TSS-71
SITC of 63A HRC Fuse(HF/HK/HQ/NH) as per TSS-72
SITC of 80A HRC Fuse as per TSS-73
SITC of 100 A HRC Fuse as per TSS-74
SITC of 160 A HRC Fuse as per TSS-75
SITC of 200 A HRC Fuse as per TSS-76
SITC of 6 A 5 pin socket as per TSS-77
SITC of 16 A 5 pin socket as per TSS-78
SITC of 6A Switch as per TSS-79
SITC of 16 A Switch with indicator as per TSS-80
SITC of 3Pin Top 5Amps as per TSS-81
SITC of 3Pin Top 15Amps as per TSS-82
SITC of casing & capping 35 mm as per TSS-83
SITC of 105 x 50 mm DLP trunking as per TSS-84
SITC of 8 SWG copper wire as per TSS-85
SITC of 14 SWG copper wire as per TSS-86
SITC of 25 x 3 mm copper earthing strip as per TSS-87
Re-fixing of existing Earthing strip/Cable on wall / floor wherever required as per TSS-88
SITC of 20A 3P Contactor as per TSS-89
SITC of 32A 3P Contactor as per TSS-90
SITC of 63A 3P Contactor as per TSS-91
SITC of Overload relay for 5 HP/10 HP motors as per TSS-92
SITC of 9 W LED lamp, BC type as per TSS-93
SITC of 11 W CFL lamp as per TSS-94
SITC of 18 W tube light as per TSS-95
SITC of 36 Watt fluroscent tube lights as per TSS-96
SITC of 70 W (SON) type lamps as per TSS-97
SITC of 250W SON type lamp as per TSS-98
SITC of 250 W Metal hallide lamp as per TSS-99
SITC of 400 W Metal hallide lamp as per TSS-100
SITC of copper ballast for various lighting fixtures as per TSS-101
SITC of LED Indication lamp for Panel (Red/Yellow/ Blue/Green) as per TSS-102
SITC of 36W LED batten fixture as per TSS-103
SITC of 50 W LED outdoor fixture as per the specifications as per TSS-104
SITC of 70 W LED outdoor fixture as per the specifications as per TSS-105
SITC of hand LED torch as per TSS-106
SITC of Emergency Light as per TSS-107
SITC of Exhaust fan 300 mm sweep as per TSS-108
SITC of Pedestal Fan 450mm as per TSS-109
SITC of Wall mounted Fan 450mm as per TSS-110
SITC of BLDC Ceiling Fan 1200mm as per TSS-111
SITC of 10HP DOL starter as per TSS-134TSS-112
SITC of motor operator model no-3VA9267-OHA20 suitable for M0320A as per TSS-113
SITC of 32A/40A, 3 phase, 4P automatic transfer switch (dual input single output) in a powder coated MS box as per TSS-114
SITC of SFU handle with mechanism in existing PCC as per TSS-115
SITC of Cable terminals Connector 10/25/35 sq.mm as per TSS-116
SITC of Panel door limit switch as per TSS-117
SITC of Digital AC Voltmeter as per TSS-118
SITC of Digital AC Ammeter as per TSS-119
SITC of 7.5KW VFD as per TSS-120
SITC of 11.0KW VFD as per TSS-121
SITC of 22.0KW VFD as per TSS-122
SITC of 30.0KW VFD as per TSS-123
SITC of Astro timer 24hrs as per TSS-124
SITC of light sensor as per TSS-125
SITC of 25 mm GI flexible conduit as per TSS-126
SITC of MS item as per TSS-127
SITC of Fire sealant material as per TSS-128
SITC of 2V,100AH VRLA cells for UPS as per TSS-129
SITC of 2V, 240AH VRLA cells for UPS as per TSS-130
SITC of 48V, 30AH LiFePO4 battery as per TSS-131
SITC of first aid Kit as perTSS-132
SITC of tool kit as per TSS-133
SITC of Multimeter as perTSS-134
Manual Excavation in normal soil as per TSS-135
GROMOS INDIA (BID ID -3238153)
RCK Electrical Enterprises (BID ID -3238406)
TECHNOCRATS SECURITY SYSTEMS PVT LTD (BID ID -3238362)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 14.86 MB
Tender_document_ET9.pdf
Tender Documents • 1.39 MB
Proforma_of_schedules_BARC_TSD_ET_9_2025_2026.pdf
Tender Documents • 0.15 MB
Specification_ET9.pdf
Tender Documents • 1.20 MB
SCHEDULE-A_BARC_TSD_ET_9_2025_2026.pdf
Tender Documents • 0.14 MB
Man_Power_Recovery_sheet_BARC_TSD_ET_9_2025_26.pdf
Tender Documents • 0.10 MB
TECHNICAL_BID_BARC_TSD_ET_9_2025_2026.xls
Tender Documents • 0.27 MB
BOQ_907868.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .