| 3 | L3₹28.4 L+₹5.8 L (25.5%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
26 Jun 2024, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD
REPAIR TO HT SWITCH GEARS DEHYDRATION OF TRANSFORMER AND OTHER MISC WORKS AT AFA HYDERABAD
2024_MES_656604_1
86753/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AFA HYDERABAD
As per NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹60,000
Yes
9 Jul 2024
29 May 2024
28 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
30 May 2024 - 11 Jun 2024
Amount
M&L for Testing of dielectric strength of transformer oil of indoor/outdoor type transformer, 11 KV / 433 volt, filteration of transformer oil by passing through filtration plant to remove moisture, improving di-electic strength to above 40 KV for 1 minute including new transformer oil for filling/ toping up & testing after filtration complete all as specified and as directed. (Note:- NewTransformer oil will be measured and paid separately under relavent Item
M&L for toping / filling up / replacement of transformer oil with 50 KV di-electric strength complete all as specified.
M&L for replacement of Silica Gel breathers including silica gel, suitable for transformers 11 KV / 433 Volts of the following capacity :-
M & L for replacement of thermometer (oil temperature gauge) for indoor type transformer, complete all as specified and as directed .
M&L for Disconnecting of LT and HT cable carefully from Transformer and draining out transformer oil, Removing transformer top cover and dismantling of 4 Nos LT bushing and 3 Nos of HT bushing,Tap changer to attending leakage problem with oil seal and all gaskets and replacing the burn out HT / LT bushing and copper Studs including necessary tools and plant and re assembling complete all as specified and as directed for the following capacity :- Note :- (i) Oil seal and all Gaskets are deemed to be including in coated rate. (ii) New Transformer oil ,HT,LT bushing and studs will be measured and paid separatley under relavant Item No.)
(b) 315 / 250 / 200 / 160 / 100 KVA / 400 KVA
Supply only Bushing on HT Side with copper rod complete all as directed for following capacity transformers :-
Supply only Copper stud with nut ,washers on HT Side complete all as directed for following capacity transformers :-
(b) 315 / 250 / 200 / 160 / 100 KVA/400 kva
Supply only Bushing on LT Side alongwith copper rod complete all as directed for the following capacity transformers :-
Supply only Copper stud with nut,washers on LT Side complete all as directed for following capacity transformers :-
Disconnecting the electric cable connections , taking out the voltage stablizer from its posotion at any sites situation with the help of suitable pully / crane and transporting the voltage stablizer to workshop for carrying out necessary repairs and bringing back and re-install in its original place, of capacity upto 75 KVA complete all as specified and directed
Supply only plastic sleeve suitable for moving arm unit (male & female) type suitable for existing HT 11 KV breaker.
M&L for Repair / Overhauling existing indoor type, Load Break Switch / RMU, 11 KV, SF 6, Switch Gear Panel and carrying with following and including replacement of un serviceable / damaged spare parts complete all as specified and as directed. Note : - Spare parts will be measured and paid separately under relavant Item (i) Inspecting / overhauling of Manual / motorised spring drive mechanism by checking mechanism, Motor and gear assembly, Big gear assembly, stop bolt assembly, Main shaft interlocking assembly, closing spring assembly, small cam with screw, motor cut -off limit switch, Butter fly switch assembly and apply Multi grease (Stanvac) lubricant to function smoothly. (ii) Inspecting / overhauling of assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system. (iii) Inspecting / overhauling / cleaning and inspecting insulators, vacuum interrupters, gas Chamber by carbon cleaner solution and apply dry graphite conductive sealant (Stanvac) for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items / components parts to the respective position and testing the breaker with High Voltage (DC) and Meggering before and after high voltage test complete. (v) Overhauling/testing of Metering Panel including CT and PT.
Supply only spare parts of Ring Main Unit (RMU) ,11 KV,630 Amps Make :- Schneider / ABB / Siemens complete all as specified and as directed for the following :-
Plug -In type insulators with Current carrying parts and SF6 gasket seals.
Current Transformer,250 / 1A,15 VA burdn, class 5p10 accuracy for protection
PT Fuse ,11KV/110Volts
ON / OFF push buttons
Line Voltage Indicating Unit
Terminal protection Right Angled cold applies Boot
Barrel Fuse 63 Amps
Supply only spare parts of VCB,11 KV,630 Amps 18.3 kA / 25 kA Harizontal Isolation Harizontal drawout type Make :- Schneider / ABB / Siemens complete all as specified and as directed for the following :-
Opening / Closing Push Button Assembly
Limit Switch assembly
Closing Coil Assembly 24 Volt DC/110
Tripping Coil assembly 24 Volt DC/110
Auxiliary Switch with link
Spring return latch assembly
Spout Insulators
Current transformers,100 / 50 ,1+1 Amps, Class1 and 5p10 ,15 VA Make :- Gemini Instratech / Ericon / Epitrans Electricals / Kappa / Pragati
TNC Switch
Ammeter Digital type 96 mm x 96 mm
Voltmeter Digital Type 96 mm x 96 mm
Power Factor Meter Digital type 96 mm x 96 mm
Indicating Lamps LED type 24 / 30 / 110 Volt DC or AC
Relay Microprocessed based 3 O/C and 1E/F Type 7SR10 Siemens
Relay Microprocessed based 3 O/C and 1 E/F Type MiCO M P111 Schnieder
Relay Microprocessed based 3 O/C and 1 E/F Type MC61 L&T
Master Trip Relay Type
M&L disconnect the HT/LT connection taking out the transformer from its plinth at any situation with the help of suitable cran and transporting the transformer civil work shop for carring out necessary repairs and bringing back and re-install its original place of capacity upto 400 KVA. complete all as specified and directed
Description all as per Ser Item No 17 above but Transformer Capacity is above 400 KVA to 1000 KVA
Material and labour for rewinding of HV winding with DPC insulated enamelled copper wire and as per manufacturer's specifications complete all as directed.
Material and labour for rewinding of LV winding with DPC insulated enamelled copper wire and as per manufacturer's specifications complete all as directed.
M&L for Checking /repairing of outdoor non wall type 11 KV Package compact sub station (PSS) (a) CT , (b) PT , (c) Relays and testing of of inter connection & earthing between HT Switch gears and LT switch gear with complete control wiring , over curret relay , earth fault relay , calibretation of all HT relays considering time delay and IDMT features by engaging well experince OEM/Reputed Company Rep for assessing the fault witinin the faulty circuit and rectified the same for smooth function of Compact Substataion with 1000 KVA transformer ,630 Amp HT switch gear /LBS and LT switch gear. (i) Inspecting / overhauling /cleaning and inspecting through insulators, vacuum interupters by carbon cleaner solution and apply dry graphite conductive sealant (STNVAC) for electrical contacts to avoid carbon deposits on contact surfaces. (ii) Inspecting / cleaning / overhauling of bus bar chamber by checking of bus bars, spout insulators, space heaters and removing dust with vacuum cleaner / Blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying STRIPPEX (A), STRIPPEX (B) insulating coating (STANVAC Make) and HT tape and test with High Voltage (DC) and meggering before and after high voltage test complete. (iii) Inspecting / cleaning / overhauling of CT / PT chamber by checking of Bus bars, spout insulators, space heaters, PTs, CT's and checking of wiring system and removing dust with vacuum cleaner / blower and moisture by hot air blower and checking tightness of bus bars, insulators and applying Anti Tracking Paint (STANVAC) on CT's and insulators and HT 11KV Tape. Note: Spare part will be measured & paid separetly.
M&L for filling of SF6 gas as per Manufacturer specifications complete all as specified and as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed
Excavating in post holes (or similar holes) each not exc 0.5 cum, getting out, removing and depositing where directed at a level not exceeding 1.5 mtr above the starting point to a distance not exc 250 mtr etc complete all as specified and as directed.
M&L for Cement concrete in PCC 1:3:6 type C-2 mix using with 40 mm graded stone aggregate as in foundations, fencing post hole filling and mass concrete complete all as specified and as directed.
M&L for Providing reinforced cement concrete 1:2:4 type B-1 ( using 20 mm graded stone aggregate) as in Pre-cast RCC fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area exceeding 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops etc including necessary form work complete all specified and as directed.
M&L for MS TMT bars 6 to 8 mm dia cut to length bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.90 mm dia or securing with clips complete all as specified and as directed.
All as per Ser item No30 herein before but 5 mm and over upto and including 10 mm dia bars as in stirrups, spacers and binders etc completes all as specified and as directed.
Supply only chain link MS galvanisd fencing, any size or type as approved by the Engineer-in-Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire etc complete all as specified and as directed.
M&L for mild steel round bars 10 mm to 12 mm dia as required, made to shape for securing chain link fencing etc., and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed
M&L for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 15 cm and n exc 22.5 cm long, dia of shank 11 to15 mm, complete all as specified and as directed.
S&F for Mild steel works such as angle iron, flat iron for securing fencing post in vertical and in gates, ladders, grills, guard bars, railing, and silimar works etc confirming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
M&L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying aluminium paint etc complete all as specified and as described.
S&F Galvanised. 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and as directed (Note :- eachline wire to be measured)
M&L for loose filling with aggregate of gauge 40 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface of transformer and two pole / four pole structure complete all as specified and as directed.
Surface Excavation not exc 30 cm deep and average 15 cm deep and getting out in hard/dense soil for laying of Graval /sand complete all as specified and as directed by Engr-in-Charge
M&L for Fire point with fire bucket along with iron stand, fire beater as per Fire SOP. Complete all as specified and directed by Engineer-in-charge.
HT & LT distribution layout of sub station on FRP sheet of size 1.5m x 1 m with blue background and white letter, suitable to fix on walls as per Electricals norms.Complete all as specified and directed by Engineer-in-charge.
M&L for Dismantling / Taking out the SF 6 RMU 11 KV, 630 Amps (Consisting 01 Incoming + 02 Outgoing + Meter Panel) Make Schnieder / ABB carefully and including replacement of un serviceable / damaged spare parts and shifted to factory premises to Repair / Rectification of SF6 Gas leakage problem by replacing broken Plug- In Insulators with SF6 Gas seals as per manufacturers recommendations and checking/repairing of motarised mechanism, control wiring, Current transformers, Potential transformers, Relays, barrel fuse assembly with HRC fuses including fuses compartment, measuring indicators, indicators lamps and replace the wornout unserviceable parts , broken insulators, SF6 Gas tank seals and refilling the SF6 gas. Shifting of RMU from factory primisse to Site after succefull repair and testing the RMU complete all as specified and as directed . Note :- (i) Rate is demed to be including of Tranpsportation, loading ,unloading, re errection and testing and commissioning. (ii)Spare parts will be measured paid separatly under relavent items Item (iii) Filling of SF6 gas will be measured and paid separatly under relavent Item
Srinivash Engineers
L and S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .