GE Chandigarh
GE Chandigarh N Area Pin-160003
REPAIR TO CHAJJA, COLUMNS, BEAMS AND FACIAS TO MD AND OTM ACCN AT K AREA INCLUDING SF ACCN SECTOR 28/29D UNDER GE CHANDIGARH
2024_MES_644011_1
GE/CHD-88/2023-24
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
Class E category a(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹40,000
Yes
28 Mar 2024
24 Feb 2024
23 Mar 2024
24 Feb 2024
21 Mar 2024
9 Mar 2024
24 Feb 2024 - 4 Mar 2024
Amount
Demolition of Reinforced Concrete of roofs, floors(other than ground floors ) beams, staircases . Landing chajjas and similar suspended work (upto 2nd floor) complete all as specfied and directed.
Demolition of cement concrete (un-reinforced)(upto 2nd floor), chajja ,and paving n.exc 15cm thickness complete all as specified and as directed
M&L for reinforcement cement concrete B-1, 1:2:4 (20 mm graded aggregate) Nominal mix for Slabs supported on walls,beams and lintle in floors,roofs, landings, balconies,canopies, deck slabs and the like,( upto 2nd floor )complete all as specified and directed.
M&L for reinforcement cement concrete B-1, 1:2:4 (20 mm graded aggregate) Nominal mix for chajjas supported on walls,beams ,(Upto 2nd Floor) complete all as specified and directed.
M&L for use and waste of Formwork to soffits of suspended slabs on flat ,such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat height (upto 2nd floor) complete all as specified and directed.
M&L for use and waste of Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide height (upto 2nd floor) complete all as specified and directed.
M&L for use and waste of Formwork to staircases with sloping or stepped soffits including risers and stringers (Upto 2nd floor) Complete all as specified and directed
M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT bars complete all as specified and directed.
As per item No.8 above but 6mm to 8mm dia
M&L for providing PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in roof kerb or mud stops rounded or chamfered on edges all as specified and diredted.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces complete all as specified.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of concrete surfaces as in ceiling complete all as specified.
M&L for preparation of newly plastered surfaces and two coats of Oil Bound distemper over and inluding a coat of primer on walls complete all as specified annd directed.
M&L for preparation of new undecorated surfaces of walls and applying two coat of cement based paint over and including a coat of primer, completed all as specified and directed
M&L for three coats of white wash on walls after preparation of newly plastered surfaces on Ceiling complete.
M&L for 50 mm thick guniting in patches on to the required area on RCC/PCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slab etc. of all sizes and shapes at all heights from existing ground floor and all locations with cement and mortar 1:2 (1 cement : 2 sand) under 2 to 2.8 Kg/Cm2 pressure after removing the damaged loose spalt concrete portions by chipping, removal of dust and applying one coat of rust convertor/kp-100 equivalent grade over reinforcement wherever necessary providing and tying in position 25mm x 25mm x12 gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts, curing for 10 days etc,loose spalt concrete portions by chipping, removal of dust over treated surface ready to receive grouts including 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc, complete operation all as directed , including two coat of cement base paint over a coat of primer ,including labour charges hire for all tools and plant machineries cost of consumables, scaffolding all types of protective equipments, plant floors, pipelines, vessels, materials etc. so as to do guniting in plant, removing the debris out of MOD land in low lying areas and leveling as directed,height (Upto 2nd Floorcomplete all as specified and directed by Engr-in-charge. Note (i) After placing the additional reinforcement all concrete surfaces shall be thoroughly scrubbed with brushes, washed with water and alloy to dry. To this surface apply chemistic polycrete admixture at the rate not less than 2% by weight of cement or as per manufacture’s instructions. (ii) When polymix coating is in tackey condition guniting is done with polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer’s instruction. Polycrete admixture shall be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (iii) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account. (iv) Work shall be carried out up to 4th storey Bldg
Cutting grooves in brick wall, 75 mm wide and 65 mm deep for inserting membrane and shaping horizontal face of groove with cement mortar 1:3, complete all as specified and directed.
Repairing the edges of concrete chajjas, facias, columns & the like by providing PCC (1:2:4) type B-0 including all necessary form work and/ or provision of rendering 15mm thick (average thickness) in cement mortar (1:3) with chiken wire mesh, after applying a coat of cement slurry @ 3kg/sqm of surface finished even and fair, surface area not exceeding 1.00 Mtr wide, in patches including two coat of cement base paint over a coat of primer including taking down swoolen/damaged plaster or concrete complete all as specified and as directed.
M&L for reinforcement cement concrete B-1, 1:2:4 (20 mm graded aggregate) for stair case ,including steps thread and raiser, ( upto 2nd floor ) complete,all as specified and directed.
M&L for installation of rebar by using hilti hammer drill with carbide drill bit, Chomical dispensing gun for inserting RE-500V3 Chemical upto minimum depth of (10X dia of bar) as in chajah, beam, lintel, columns slab and parapet at any height Before inserting an an anchor/bar, hole must be free from dust debris, water ice and oil grease etc by using Dia of bar 10mm complete all as per manufacture instructions. Note:- (i) Reinforcement will be measured and paid separtely. (ii) Rates are inclusive of from work shuttering and safely measures.
M&L for installation of rebar by using hilti hammer drill with carbide drill bit, Chomical dispensing gun for inserting RE-500V3 Chemical upto minimum depth of (10X dia of bar) as in chajah, beam, lintel, columns slab and parapet at any height Before inserting an an anchor/bar, hole must be free from dust debris, water ice and oil grease etc by using Dia of bar 12mm complete all as per manufacture instructions. Note:- (i) Reinforcement will be measured and paid separtely. (ii) Rates are inclusive of from work shuttering and safely measures.
Demolition of brickwork or stone/boulders masonary, built in Cement mortar or cement lime mortar including all quoins,arches,pillers etc but excluding ashlar facing etc complete all as specified.
M&L brickwork with subclass ‘B’ bricks, class Designation 10 straight or curved on plan to any radius in half brick thick walls built in CM 1:4. complete all as specified.
Brick work with sub class 'B' bricks, class Designation 10 straight or curved on plan exc 6m mean radius built in cement mortar 1:4 EXCEPT BRICKS complete all as specified and as directed.
Dismantling of AC or reinforced pipe of 110 mm and description fixed in wall , jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F in repair PVC (SWR) 110 mm bend of any radius with acess door complete all as specified and directed.
GURU NANAK CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .