| 1 | L1₹12.4 LAccepted-AOC 41 BIDHANGARH SOUTH KOLKATA 700066 | KOLKATA | KOLKATA | WEST BENGAL | 700066 | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹15.6 L+₹3.1 L (24.3%)Rejected-Finance 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹15.9 L+₹3.4 L (26.8%)Rejected-Finance | L3 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR TO EXTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY INCLUDING IR PLANT SYSTEM AND OTHER ALLIED WORKS AT DIAMOND HARBOUR UNDER GE (I) (CGP) KOLKATA
2020_MES_392925_1
8876/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹32,000
Yes
31 Dec 2020
5 Nov 2020
12 Dec 2020
5 Nov 2020
9 Dec 2020
20 Nov 2020
60 days
Amount
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
M&L for sand cushioning for protection of cables (below, above and around the cable laid in trenches) complete using clean, dry sand complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed.
Taking up or down 15 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 25 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 40 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
Taking up or down 50 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
S&F 15 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 20 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 25 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 40 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 50 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 50 mm dia steel water tube light grade galvanised with all fittings and fixed complete to trenches complete all as specified and as directed.
S&F 20 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 25 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 40 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 50 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
Repair of 80/100/150 mm CI Sluice valve by taking out from site, dismantling, refacing, regrinding, repacking of stuffing box etc and fixing after necessary repair for smooth and leakage free operation and refixed at previous position incl rubber gasket at both flanged end complete all as specified and directed.
M&L for cast iron sluice valve both end flanged class PN 1.6 cm firming to IS-780 with iron wheel head and brass spindle of size 100 mm bore sluice valve including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L for cast iron sluice valve both end flanged class PN 1.6 cm firming to IS-780 with iron wheel head and brass spindle of size 80 mm bore sluice valve including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
Taking out existing submersible pump set of any capacity along with column pipe from the bore well and lowering the same after repairing the pump set including and reconnection all electric & mechanical connection. (Note (i) One lifting & one lowering shall be measured one job (ii) Repair to pumps & motor and replacement of spare parts shall be measured and paid separately. (iii) Replacement of column pipe if required shall be measured & paid separately as supply only under respective item in this Schedule)
Supply only MS ERW column pipe 80 mm bore 3.0 m long with both end flanged type with heavy duty 7.0 mm thickness with rubber gasket complete all as specified and as directed. (Make - TATA or equivalent)
Dismantling carefully submersible pump and taking out and replacement of locknut, impeller key, collar ring, SS coupling nuts, bolts, washer and re-assembling the pump of capacity 10/12.5/15 HP and painting the pump set with two coats of synthetic enamel paint over a coat of red oxide primer after scraping out old paint complete all as specified and directed. (Note : (i) Spare parts like Thrust bearing, Impeller, Sand Guard, Bush, Shaft, NRV if required shall be measured and paid separately under respective items in this Schedule as supply only. (ii) Winding of motor if required shall be measured and paid separately under respective item in this Schedule )
Supply only Thrust bearing for submersible pump of capacity 10/12.5/15 HP Make - Calama, KSB, CRI.
Supply only Gun Metal Impeller for submersible pump of capacity 10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Sand Guard for submersible pump of capacity 10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Gun Metal Bush for submersible pump of capacity 10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Stainless Steel Shaft for submersible pump of capacity 10/12.5/15 HP Make Calama, KSB, CRI.
Supply only NRV for submersible pump of capacity 10 HP Make Calama, KSB, CRI.
M&L for rewinding of electric motor of 10/12.5/15HP (Submersible motor) with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding, cleaning of stator and rooter including replacement of bearing etc. including testing & commissioning complete all as specified and directed.
S&F PVC insulated water proof 3 core cable suitable for submersible pump set 1100 volts grade with standard copper conductor cable of size 6 sqmm complete all as specified and directed including taking down old one.
Supply and laying 100mm bore, Ductile Iron Pipe, conforming to IS-8329/2000, flanged ends ends, centrifugally cast Type K-9, in any length laid in trenches including taking down old one complete all as specified and directed . (Make : Electrosteel Castings Ltd / Keshoram). ( Note : Jointing and excavation shall be measured and paid separately under respective items in this schedule).
M&L for DI pipes fittings upto 150 mm bore, such as bend (any type radius and angle) tapers, any type (straight bend increasing decreasing or double socket etc) Tee piece single branch junction 'Y' junction, cross, double branch (all sockets and/or socket and spigot) collars caps and plugs etc complete all as specified and as directed.
Cutting CI / DI water mains in position for insertions of new fittings such as Tee, bend collar etc as required complete all as specified and as directed up to 150 mm dia CI pipes.
M&L Rubber gasket joint for 25 mm to 100 mm bore CI flanged pipe complete all as specified and directed including taking down unserviceable joints.
M&L one coat of synthetic enamel painting over a coat of red oxide primer after scraping, cleaning the rusted surface with the help of sand paper/ wire brush of the complete and after cleaning of rusted surface painting with the help of painting brush for all existing pump motor, IR filter, water pipe network of pump house, existing pannel and accessory, valve etec, all as per existing colour all as specified and directed.
Repair to electromagnetic sodium hypochloride solution dosing pump of cap 2 Ltr/hr incl 0.5 HP motor by replacement of unserviceable parts (i.e. bush/bearing etc) for smooth functioing of pumps at installations as directed and necessary testing complete all as specified and as directed. NOTE : i) Any minor repairs invloved to make the motor completely functional, even if not notified by the EIC, shall be carried out by the contractor without any extra cost to the department. ii) Parts likeStroke knob,inlet outlet PVC nozzle, PVC block, taflon washer, etc as reqd shall be done by the controctor without any extra cost to the department.)
Taking out old unserviceable LT cables of cross sectional area upto 120 sqmm including bricks or pre-cast concrete cable cover etc of any description from trenches / walls / poles by disconnecting the cable from pole /feeder /panel board etc. and keep serviceable bricks or pre-cast concrete cover, cable, pipe etc. in safe custody for re-use and unserviceable materials removing from site all as specified and as directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 35 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 70 Sqmm 3.5 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/in trenches 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 95 Sqmm 3.5 core complete all as specified and as directed.
M&L cleaning the internal surfaces of RCC overhead reservoir of capacity 20000 gallon at 18 metre staging height by brooming and rubbing with coir brush, scraping with wire brushes, rubbing down scale, dirt, sludge etc. and washing with clear water using bleaching powder/caustic soda and taking out all rubbish from the reservoir and removing from the reservoir complete all as specified and as directed. Note : consumption of bleaching powder for cleaning of tank shall not be less than 15 Kg. after cleaning of tank date of claning will also written by contractor in bold letters.
M&L cleaning the internal surfaces of Static Tank reservoir for fire fighting of existing capacity semi underground type by brooming and rubbing with coir brush, scraping with wire brushes, rubbing down scale, dirt, sludge etc. and washing with clear water using bleaching powder/caustic soda and taking out all rubbish from the reservoir and removing from the reservoir complete all as specified and as directed. Note : consumption of bleaching powder for cleaning of tank shall not be less than 15 Kg. after cleaning of tank date of claning will also written by contractor in bold letters.
M&L for Preparation of internal surfaces of RCC overhead reservoir of capacity 20000 gallon at 18 metre staging height and applying two coates of anti corrosive bituminous lead free paint suitable for storage of potable water (for internal surfaces) complete all as specified & directed.
Material and labour for PVC cable end terminal boxes outdoor type, 30x20cm, PVC door, sintex box provision for cable incoming and outdoing from bottom, comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way completed fixed on wall/pole with necessary clamps, screw etc all as specified and directed including taking out old one. Make Sintex Model No GSJB 3020 or equivalent
Supply & fix street light timer Timer FM1 / Quartz Daily 240V AC Base/DIN Mounting analogue type suitable for street light control complete all as specified & directed including taking down old one. (Make : L & T Cat no. AUTS01ANA00 or equivalent of)
Repair and maintenance of RO plantof 100 LPH capacity and associated accessories by cleaning all filters, replacing RO membrane, sedimental carbon block, sedimental vatridge and micron overhauling of Booster pump, SMPS panel, low oressure switch and solenoid valve as and when required complete all as specified and directed .Note -Price for items to be replaced are deemed included in the item rate
Repairing /Replacement of water indicating system for OH tank including floating arrangement, rope, scalling system and all necessary connecting arrangement all as specified and as directed.
M&L cement concrete 1:3:6 Type C1 (using 20 mm graded crushed stone aggregate) as in coping, roof kerb or similar work, rounded or chamfered on edges including necessary form work complete all as specified and directed.
Supply and fixing MCCB, 125 to 160 Amps, 4pole, 25 KA breaking capacity, DU250C, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make- L&T, , Cat no. CM90634OOMO or equivalent in ABB/Schnieder
Supply and fixing MCCB 16 to 100 Amps, 4pole, 16 KA breaking cap , DU 100H, 415 Volts with necessary cable lugs complete all as specified and directed including taking down old burnt/unserviceable one complete all as specified and directed. Make- L&T, type - DU 100H, Cat no. CM97894OOJ2 or equivalent in ABB/Schnieder
M&L for wiring with two runs of 2.5 sqmm (Nominal area) single core PVC insulated multistranded unsheathed FRLS copper conductor cable upto and including 1100 V grade drawn through and including PVC RIGID CONDUIT with all fittings fixed to pole incl one run of 1.5 sqmm (nominal area) single core, PVC insulated multistranded unsheathed FRLS copper conductor as earth wire complete all as specified and directed including taking down old unserviceable one. (Note :-(i) One run of PVC conduit, two runs of 2.5 sqmm single core cable, one run of 1.5 sqmm earth continuity wire to be measured as one length).
Repair/maintannces of transformer of any make 11 KV/440V step down type & capacity for 800 KVA & below by disconnecting electric supply draining out transformer oil and stocking for re-use opening up top cover, checking / cleaning the core by hanging up the Tr. core/winding, HT/LT winding , tank conservator, connections etc removing sludge/scaling etc deposited. Opening the HT/LT terminal boxes, checking / changing /cleaning the bushes oil seals, gaskets nuts & bolts etc as required number checking & replacement of top cover gasket, breather & vent pipe gasket, reassembling testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of transforerms shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate (iii) Major parts/accessoreis for transformer shall be meausured and paid separately under respective items in this schedule.
Repairing of servo make Voltage stabilizer (a) Dismantling of servo Make Stabilizer, 400 KVA,3 Phase,4 wire output current 217 Amps per phase Input voltage range 320-460 Amps out put voltage -400V+-1% Break down strength &IR-1500 Volts AC for 2 Minutes greater than 50 Mega ohms & 500 volts DC (b) Drain out Transformer oil & disconnected the Main panel & replacement of overload cut-off & short circuit protection, low & high voltage (output range) alarm cut-off. Changing of digital multi function meter. (c) Rewinding of output transformer complete, including replacement of dimer set, replacement of logic board, refilling of transformer oil (d) Reflixing of voltage stablizer after repair and testing complete.
Dehydration & filteration of transformer oil for various type transformer / OCB / VLE as retrieved in above items by heating of oil, testing dielectric strength of oil not less than 60KV in 2.5mm sparking gap complete all as specified and as directed.
Supply & filling only Transformer Oil for topping up the level( after necessry disconnection and earthing both winding) with grade as per IS : 335 complete incl opening the tank cover and refixing the same and charging the transformer to the supply voltage complete all as specified and as directed including taking out old one. (Note : BDV of the oil shall be ensured not less than 60 KV before filling) (Make of Oil - Poweroil/ Gulf)
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 25 x 4 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 50 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work including taking down old one complete all as shown in elect plate No. 3 of SSR Part I, all as directed by Engineer-in-Charge.
Supply and fix MS Bracket made of 50mm dia MS pipe medium grade 1.5mtr long suitable for street light on steel / RCC pole as per site requirement including suitable nut,bolt and clamps complete accesseries all as specified and directed and taking out old one.
Material and labour for painting to Steel tublar poles 9 m long with one coat of Synthetic enamel paint black & yellow combination Zebra marking up to 1 m from ground level /copping remaining portion with all cross arm, bracing, cable protection pipe, clamps etc. painting with one coat of aluminium paint and writing 50 mm size figure/letter over back ground for marking pole numbers with white synthetic enamel paint complete including preparation of old painted surfaces etc all as specified and as directed.
S&F of Dimmerstat 1000 ohm capacity for voltage stabilizer complete all as specified and as directed including taking down old one.
S&F of Voltage controller PCB Circuit for voltage stabilizer complete all as specified and as directed including taking down old one.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for Out door heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - M-seal / Denson / Raychem)
M & L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - M-seal / Denson / Raychem)
M & L Cable jointing kit for LT 1100 V (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 2/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 35 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - M-seal / Denson / Raychem)
M & L Cable jointing kit for LT 1100 V (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm incl cutting of old jointing material including taking down old one complete all as specified and as directed. (Make of Kit - M-seal / Denson / Raychem)
Supply and fixing 5 KVAR capacitor, box series heavy duty, 440V, complete including taking down old one all as specified and directed. (Make- L&T type-LTXL-Ultra /BCH/ABB)
Supply and fix pole power Contactor, type ML-2, Fr-3, rating AC-3 110 A, including taking down old one complete all as specified and directed. (cat NO-SS90701 of Make-L&T or equivalent in ABB/Schneider)
Supply and fix MCB DP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4086 28-36 or equivalent in Schneider/GE )
Supply and fix MCB FP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4086 91-99 or equivalent in Schneider/GE )
Supply and fix MCB SP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make : Legrand cat No 4085 87 or equivalent in Schneider/GE )
Supply and fix RYB indicator lamp LED pilot lamp with BA 9S lamp filament bulb for input voltage 240V and output volt 6V AC complete all as specified and directed. (Make - C&S /ABB/L&T)
Repairing of High mast light including lifting up / down, rope, gear repairing and lifting motor etc without flodd light complete all as specified and directed.
Supply only calcium based High strength granular chlorination chemical , Altoch Gp having 60 - 70% chlorine having corrsion inhibitors to prevent encrustation and scaling in distribution systems for water complete all as specified & directed. (Make : DECLIBAC TECHNOLOGIES Pvt Ltd, POTTER & WATTS AND BRIZING UNLIMITED or its equivalent)
Supply and fixing LED aviation light luminaires comprising of aluminium housing with polycarbonate enclosure, incl taking down old one complete all as specified and as directed. ( type - BGAV 302 LED, Cat No-110731 of make Bajaj or Philips/Crompton greves)
Supply and fixing of LED street light 60 W with all fittings accessories including braket including taking down old unserviceable fitting complete all specified and directed. Make: CG cat part No LSTP-60-CDL-M or equivalent Havells /Bajaj/philips
M&L for Decorative post top lantern for 360 degree, 40 Watt, indirect light suitable for pipe 50 mm dia including connnection from connector to switch including taking down old unserviceable fitting complete all specified and directed. Make: CG cat part No-LPTM-40-CDL or equivalent Havells /Bajaj/philips
M&L two coat of synthetic enamel painting over a oat of red oxide primer after scraping, cleaning the rusted surface with the help of sand paper/ wire brush of the complete and after cleaning ofrusted surface painting with the help of painting brush for existing feed piller box all as per existing colour complete all as specified and as directed.
Supply and fixing of LED flood light 15000 lm (150 W) including electronic driver and all fixing arrangement including taking down old unserviceable fitting complete all specified and directed. Make: CG cat part No LFLN-150-CDL/60-M or equivalent Havells /Bajaj/philips
Supply and fixing of LED building security light 20 W including bracket and all necessary arrangement including taking down old unserviceable fitting complete all specified and directed. Make: CG cat part No LSTS-20-CDL-M or equivalent Havells /Bajaj/philips
Repair / overhauling and servicing of Diesel Engine set for fire fighting pump / Generator Gen Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM, Make : Kirloskar / Greaves cotton limited (a) Dismantling and shifting of DG set from existing position and re-installing and commissioning in the same position after repair.(b) Dismantling the complete DG set part by part and cleaning thoroughly by degreasing and de-carbonising all the rotary and static parts. (c) De sludging de-carbonising & degreasing of all the parts / components such as PT Pump, Hydraulic Governer, Terbocharger, Water pump and also checking of all rotary and stationery parts of DG set for smooth functioning of engine, adjusting the pressure regulate valve settings and carrying out calibration by complete checking, aligning with fuel pump control system duly providing necessary gaskets, belts, and re-assembling after repair / replacement of unserviceable parts including greasing as required and testing complete all as specified and directed. (Note:- Spare required Shall be measured and paid as supply and fixing under respective items in this schedule)
Supply only lube oil filter element suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only diesel filter assembly suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only lube oil cooler pipe suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only super bypass mobil filter suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only readiator cap suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only air cleaner filter element suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
M&L tank cleaning for Diesel Engine set , (40KVA/ 62.5 KVA capacity) and reassembling the same and reconnection to the fuel supply pipe line, testing after reconnection complete all as specified and directed. (NOTE :- cost of reqd item involved shall be deemed to be included in the unit rate quoted).
Supply only mobil oil(20W-40) suitable for DG Set of capacity 40KVA/ 62.5 KVA, AC 3 phase, 415 Volts, 50 HZ, 0.8 PF, 1500 RPM.
Supply only Coolent 1 litre pack suitable for DG Set of capacity 40KVA/ 62.5 KVA AC 3 phase 415 Volts 50 HZ 0.8 PF 1500 RPM
Supply and fixing battery 12 volt, 180 AH including taking down unserviceable battary complete all as specified and as directed. (Make - Exide Cat No MHD 1600 Express or equivalent in Amron / SF)
M&L for rewinding of electric motor of 1/2/3 HP (Submersible motor) with super enemalled copper wire of existing gauge with taking down burnt winding, cleaning of stator and rooter including replacement of bearing etc. including testing & commissioning complete all as specified and directed.
Supply and fixing of DOL starter sutable for open well submersible pump set of capacity 1/2/3 HP, 1ph,230 Volt, for fountain complete all as specified and directed including taking down old one. Make : L&T/BCH/CG.
Supply, fixing and testing flat type 3 core submersible cable, FR of size 4.0 sq mm, 1100 Volt, for fountain complete all as specified and directed including taking down old one . Make : Finolex/MESCAB/Anchor.
Supply and fixing of 20T Geyser nozzle brass with all necessary arrangment for fountain complete all as specified and directed including taking down old one.
Supply and fixing suction filter 50 mm PVC with all necessary arrangment for fountain complete all as specified and directed including taking down old one.
M&L for repairing the GI/PVC/MS pipe any size for fountain including welding and replace all unserviceable parts like tee, bend, socket, union with painting complete all as specified and directed.
Supply, fixing and testing of water proof submersible type colour changing light 9 watt IP 68 protection die cast deep drawn stainless steel encloser with high quality toughened glass toughened including taking down old one complete all as spectified and directed.
Comprehensive maintenance of electically operated washer extractor and drying tumbler capacity 30 KG heavy duty, 3 HP,50 HZ,415 volt, 3 phase. Make : FABCARE at SSB Diamond Harbour keeping the machines and the accessories in perfect and working condition with the repair/ replacement of all defective/worn out parts/ components, lubricating of the machines all as required without affecting normal funcitioning complete all as specified and as directed.
Development of existing bore well of any size by using compressor with necessary arrangement to remove the sand/waste materials inside the bore well with pressure of air upto 4.5 kg/sq cm untill obtaining sand free water complete all as directed. Note -DHPP & all chemicals to be arranged by the contractor and price is deemed included in the item rate.
Opening top cover of manhole by unscrewing the bolts of 45 cum/hrs capacity Oxidation chamber plant 800mm dia x 650 mm HOS, 3.5 Kg/mm2pressure capacity, unlloading the unsv MNO2 from upper portion of oxidation plant and disposal of unsv MnO2 within 100 metere radious from the existing filter plant and cleaning the inside chamber through chemical,brush etc complete all as entire satisfaction of complete all as specified and as directed.
Opening top cover of manhole and side hand hole of 45 cum/hrs capacity pressure filter vertical type 1600mm dia x 1875 mm HOS, 3.5 Kg/mm2 pressure capacity, unloading the filter media from the pressure filter e.g sand gravells (diferent sizes) takings out carefully strainer (Push/Thread) from inside bed plate, cleaning the inside chamber through chemical,brush etc and disposal of unsv filter media( sand,gravel,stainer etc) within 100 metere radious from the existing filter plant complete all as specified and as directed.
Supply and fix PVC strainer push fit for pressure filter as per existing size & shape including taking down old one complete all as specified and as directed.
Fixing only PVC strainer push fit for pressure filter as per existing size & shape complete all as specified and as directed.
Supply & laying of new filter sand of 10 x 40 mesh from Barakar layer by layer as per designed layer to the pressure filters at different location complete all as specified and as directed.
Supply & laying the new graded gravels of different size ( Gravel of size 1.5" x 1", Pebbles of size 1" x 1/2", Core silex of size 1/2" x 1/4", Fine silex of size 1/4" X 1/8") inside the pressure filters at different location.
Supply and loading of MNO2 in the exisitng Oxidation chamber plant complete all as specified and as directed.
S&F Vessel manhole and hand hole gasket of existing size complete all as specified and as directed.
S&F butter fly valve (water type) of size 100mm dia with fiber gasket including taking down old one complete all as specified and as directed.
S & F MS frontal pipe 80 mm bore heavy duty with bend ,Tee etc flange type or welded of any length including taking down existing pipe complete all as specified and as directed.
Repair/maintannces of transformer of any make 11 KV/440V step down type & capacity for 120 KVA by disconnecting electric supply draining out transformer oil and stocking for re-use opening up top cover, checking / cleaning the core by hanging up the Tr. core/winding, HT/LT winding , tank conservator, connections etc removing sludge/scaling etc deposited. Opening the HT/LT terminal boxes, checking / changing /cleaning the bushes oil seals, gaskets nuts & bolts etc as required number checking & replacement of top cover gasket, breather & vent pipe gasket, reassembling testing & commissioning complete all as specified and as directed. (Note : (i) Maintenance /repairs of transforerms shall be carried out by trained technicians/mechanic under super vison of qualified electrical technician. (ii) All repairs shall be carried out at site only. Necessary testing,/measuring instrument shall be brought at site by the contractor at the time of work and all cost on this account should be included in the quoted rate (iii) Major parts/accessoreis for transformer shall be meausured and paid separately under respective items in this schedule.
MS AP CONSTRUTION AND CO
S C ROY AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .