Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC H NO 1 16 70 SAI NAGAR COLONY ALWAL SECUNDERABAD 500015 | HYDERABAD | TELANGANA | 500015 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.7 L+₹4.3 L (12.0%)Rejected-AOC H NO 1 7 1 79 1 ROAD NO 7 REDDY ENCLAVE TEMPLE ALWAL SECUNDERABAD 500 010 | HYDERABAD | TELANGANA | 500010 | L2 | Rejected-AOC Not Lowest Bidder | |
| 3 | L3₹41.8 L+₹6.4 L (18.0%)Rejected-AOC | L3 | Rejected-AOC Not Lowest Bidder | |
| 4 | L4₹41.9 L+₹6.4 L (18.1%)Rejected-AOC SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-AOC Not Lowest Bidder | |
| 5 | L5₹46.0 L+₹10.5 L (29.5%)Rejected-AOC | L5 | Rejected-AOC Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Mar 2021, 6:00 pmClosed
GARRISON ENGINEER NORTH SECUNDERABAD
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
REPAIRS TO LEAKAGE SEEPAGE IN ZONE C UNDER AGE BR N NO I OF GE NORTH SECUNDERABAD
2021_MES_419759_1
8971
Open Tender
Civil Works
Works
270 days
Garrison Engineer North 35 Allenby Lines Secundera
For Enlisted Contractors Class D Category ai and for Un Enlisted contractors meeting the Enlistment criteria for appropriate class and category along with EMD
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER NORTH SECUNDERABAD
₹90,000
Yes
23 Mar 2021
6 Feb 2021
8 Mar 2021
6 Feb 2021
5 Mar 2021
20 Feb 2021
6 Feb 2021 - 19 Feb 2021
Amount
Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing complete all as specified and as directed.
All as per item No 1 above but on 20mm dia complete all as specified and as directed.
Refixing old steel tubing of 15 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed.
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and as directed.
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 20 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 15 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fitting complete all as specified and as directed.
S & F 20 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed in repairs including taking down the existing fittingcomplete all as specified and as directed.
Disconnecting existing tanks, setting aside ( or lowering if required) for repairs, cleaning etc.,and hoisting if required reconnecting and re-fixing in position of tank capacity exceeding 250lit but not exceeding 500 lit complete all as specified and as directed.
Dismantling water tanks and ( exceeding 250 and not exceeding 500 ltr capacity) complete all as specified and as directed.
Demolition of un-reinforcement cement concrete as in base of water tank on roof complete all as specified and as directed.
M & L rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 500 ltrs complete fixed in repairs complete all as specified and as directed.
S & F in repairs 20 mm dia PTMT ball Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule including taking down the existing valve complete all as specified and as directed.
M & L cement concrete 75mm thick type C-1 (1:3:6) using 20mm graded stone aggregate as in base of tank complete all as specified and as directed.
Taking down of old bituminous tarfelt or any other type of roof treatment from roof/ concrete surfaces removal to distance exceeding 250 metres and not exceeding 500 metres from the site and cleaning of the roof surface with wire brush to make it free from dust, dirt etc complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided in roof padding concrete complete all as specified and as directed.
M & L PCC (1:2:4) Type B1 (using 20 mm graded stone aggregatesagg as in levelling/padding course on roof slab for water proofing treatment complete all as specified and as directed.
Material and labour for rendering 10mm thick on roof surfaces in cement mortar 1:4 duly mixing with water proofing compound at the rate of 2% by weight of cement and finished even and smooth complete all as specified and as directed Note: Water proofing compound will be measured and paid separately under relevant item in this schedule
Supply only water proofing compound of ISI marked complete all as specified and as directed.
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres over that a coat of blown bitumen of 85 / 25 at the rate of 1.2 kilogram per square metre over that a coat of bituminous aluminium paint at the rate of 100 grams per square metre complete all as specified and as directed.
Material and labour for application of one coat of water based bitumen emulsion primer at the rate of 0.3 litres per square metre after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of weight 3.5 Kilogram per square metre and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres APP, membrane grit finish on roof slab all as per manufacturer's instructions and zonal specification including dismantling /demolition of old existing treatment on accessible roofs and removing the debris complete all as specified and as directed.
M&L for 20mm thick screed bed in CM 1:4 mixed with 80ml per kg of cement or as per manufacturer's instructions of polymeric liquid water proofing additive over Non woven Geo textile layer to ensure no puncture of APP membrane over polymeric membrane surface etc complete all as specified and as directed. Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
M&L for laying 300 mm x 300 mm x 20 mm thick PCC tiles (Hydraulically pressed) with grey cement, set, jointed, cut and polished. The joints shall be grouted and immediately after gouting, the joints shall be pointed flush in in CM 1:3 mixed with 150ml per kg of cement of polymeric based lilquid water proofing additive by weight of cement or as per manufacturers instructions etc complete all as specified and as directed. Note : Supply of polymeric based liqluid water proofing compound will be measured and paid separately)
Supply only polymer based lilquid water proofing compound complete all as specified and as directed. .
M&L for making the grooves to 'V' section in existing parapet walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
M&L for injecting chemical GLYPHOSPHATE 41% SL 20 ml or till refusal by making cuty/injection of the stem of plant 30 mm C/C and spraying with solution (25 ml GLYPHOSPHATE 41% diluted with 1 ltr of water) and removing the plant/vegitation including penetrated roots complete including necesary scaffolding etc all as specified and directed for plants/vegetation
Dismantling of Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. Note :- Dismantling shall to be carried out in patches of area as ordered by Engr-in-charge
Supply and fix pre-painted galvalume aluminium zinc coating galvanised based corrugated steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as roof covering/cladding to wall fixed with self tapping (SD) screws complete all as specified and as directed
Supply and fix pre-painted galvalume aluminium zinc coating galvanised based plain steel sheet of 0.50 mm thick of approved colour having tensile strength of 550 Mpa as ridge, gutters fixed with self tapping (SD) screws complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Supply and fix hand rails, half rounded or other stock section or core for wooden hand rail straight portion, drilled and counter sunk for balusters, nosing to steps including embeding in concrete and screwing etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, flat iron fillets (for securing wire mesh etc) including all necessary drilling or riveting etc and similar work confirming to Fe-410-0 of Fe-310-0 of Gde E-165 complete all as specified and as directed
Supply and fix rolled mild steel sections of Fe 410-W (GDE E-250) QUALITY “A” frame work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and as directed
Taking down cement plaster of any description and thickness on brick walls including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 without using extra cement complete all as specified and as directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar with all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles including disposal of the rubbish out off the premises complete all as specified and as directed.
Material and labour for Brickwork with fly ash bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed
Material and labour for preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of alkali resistant primer complete all as specified and as directed
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
Material and labour for plain cement concrete 1:2:4, type B1 using 20 mm graded stone aggregate as in bed block, coping, roof kerbs, bands etc including necessary form work complete all as specified and as directed
Material and labour for preparing the new steel surfaces of any description over 10 centimetre width or girth and not otherwise described and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all specified and as directed
Material and labour for painting steel surfaces of any description, not exceeding 10 centimetre width or girth when unconnected with other painting (different tint) and applying two coats of synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed.
Taking down loose material by chiselling, chipping from beam , stair, column, railing, pardi walls etc cleaning the surfaces and guiniting in CM 1:3, 30mm thick including use and waste form work and providing welded wire mesh size 100 x 100 mm of wire 3, finishing the guiniting surfaces in cement mortar 1:3, 10mm with water proofing compound 2% by weight of cement and finishing even and smooth without using extra cement to match the existing complete all as specified and as directed.
All as per item No 44 above but for slabs / chajjas and thickness of guiniting 25mm and finished even and smooth with 5mm thick cement plaster 1:3 using water proofing compound 2% by weight of cement all as specified and directed.
M&L for Reinforced Cement Concrete (Nominal Mix) Type A1 1:11/2:3 (using 20 mm graded stone aggregate) in Chajjas and the like complete all as specified and as directed.
Use and waste form work on fair finished flat surfaces of Chajjas including edges complete all as specified and as directed.
Drilling of holes in RCC members for fixing additional reinforcement with anchorage and fixing with HILTY chemical complete all as specified and directed.
S&F Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M & L for preparing the old plastered or unplastered decorated surfaces of walls and applying one coat of white wash all as specified and as directed.
M & L for preparing old distempered surfaces of walls, by washing, rubbing down, stopping and applying one coat of distemper oil emulsion of any colour all as specified and as directed.
M & L for preparation of old painted wooden surfaces of any description over 10 centimetre width or girth and applying one coat of synthetic enamel paint all as specified and as directed.
M & L for preparation of old painted steel and iron surfaces of any description over 10 centimetre width or girth and applying a coat of synthetic enamel paint all as specified and diracted
Dismantling of AC corrugated or semi corrugated sheeting in roof including ridges etc. Note :- Dismantling will have to be carried out in patches of area complete all as specified and as directed.
M & L for 6 mm thick asbestos cement corrugated or semi-corrugated sheet in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts complete all as specified and as directed.
M & L for 6mm thick asbestos cement two piece adjustable serrated ridge suitable for corrugated or semi corrugated sheets in roofs fixed with ‘L’ type or ‘J’ type or cranked hook bolts complete all as specified and as directed.
Dismantling boarding of any description fixed in any position with nails all as specified and as directed including frame work complete all as specified and as directed.
Supply and fix E grid suspended false ceiling grid system of size 600x600mm with main runner 39x29.7x0.60mm cross tee 29x24.7x0.60mm and wall angle 22.2x22.2x0.50mm. Ceiling suspended with 2 to 2.5 mm dia GI wire hanger fixed with purlin/truss etc complete (Main runner, cross tee, wall angle of ms galvanised with PPCGS) over the grid providing 4mm thick HPSC pre primered self designer texture non asbestos fibre cement building board fixed to frames etc complete all as specified and as directed
G SATISH REDDY AND CO
SURA INFRASTRUCTURE
R G NAIDU CIVIL CONTRACTOR AND BUILDERS
SKY CONSTRUCTIONS
SN POWER TECH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .