| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC NETAJI COLONY WARD NO 36 SILIGURI 734 006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | ₹3.7 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹3.8 LRejected-Finance RAJA RAMMOHAN ROY ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹3.8 L | L2 | Rejected-Finance Being L2 |
| 3 | L3₹4.0 LRejected-Finance ATUL PRASAD SARANI SILIGURI 734006 | SILIGURI | DARJEELING | WEST BENGAL | 734006 | ₹4.0 L | L3 | Rejected-Finance Being L3 |
| Sl No | Description | Qty | Unit | M/S. P K ENTERPRISE L2 | RAJESH ENTERPRISE L3 | M/S S.T. HIGH VOLTAGE L1 |
|---|---|---|---|---|---|---|
| 1.00 | S&D of minimum High Wall inverter type Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (5.2KW-5.3 KW), Air flow rate (550-828) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 15 A Plug Top. PCB unit must be enclosed within metal enclosure. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/Sharp/ Mitsubishi Heavy/Voltas) | 5 | each | 61,000 ₹3.0 L | 65,000 ₹3.3 L | 59,600 ₹3.0 L |
| 2.00 | Installation Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC Machine after making hole in wall etc as per direction of EIC including making arrangement for outdoor unit by suitable size angle iron frame as per direction of E.I.C | 5 | each | 3,000 ₹15,000 | 2,900 ₹14,500 | 2,600 ₹13,000 |
| 3.00 | Supply and drawing 5/8" & 3/8" or 1/2" & 1/4" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation an Al foil tape complete fittings Elbows, Bends, Supporting arrangement on walls along with other accessories on the surface of wall. | 35 | each | 825 ₹28,875 | 850 ₹29,750 | 800 ₹28,000 |
| 4.00Supply and laying of 1.1 KV single core stranded 'PVC insulated FRLSH grade copper cable incl socketing, shaddling etc.as per direction of EIC ( Make : Finolex/ Havells/ Polycab/ KEI / RR or Brand approved by EIC) of requisite following diameter for the above Air-Conditioners as per direction of Engineer - In - Charge incl. necy. fittings as required as per G.S . [Power cable for connection betweeen indoor and outdoor units & also Control Cable for connection betweeen outdoor units to indoor ] | ||||||
| 4.10 | 3 core x 4.0 mm² Round PVC insulated copper cable | 40 | Mtr | 400 ₹16,000 | 410 ₹16,400 | 390 ₹15,600 |
| 4.20 | 4 core x 2.5 mm² Round PVC insulated copper cable | 40 | Mtr | 350 ₹14,000 | 360 ₹14,400 | 330 ₹13,200 |
| 5.00 | Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors. | 38 | Mtr | 85 ₹3,230 | 90 ₹3,420 | 83 ₹3,154 |
Tender Value
Refer Docs
EMD Value
₹7,440
Closing Date
3 Jan 2026, 12:00 pmClosed
EE/DED
Opposite of PWD Inspection Bungalow Kachari Road, Siliguri 734001, District Darjeeling
SITC of Air-Conditioning arrangement in the office of Senior Superintending Engineer, Northern Circle, Social Sector, P.W.Dte., Siliguri.
2025_WBPWD_966858_1
WBPWD/EE/DED/e-NIT-55 of 2025-26
Open Tender
ELECTRICAL WORKS M/R
7 days
SILIGURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,440
11 May 2026
5 Dec 2025
5 Jan 2026
5 Dec 2025
3 Jan 2026
5 Dec 2025
Amount
S&D of minimum High Wall inverter type Split Air Conditioner with R410A / R407C / R-32 Refrigerant, with Rotary Compressor with minimum Cooling Capacity of (5.2KW-5.3 KW), Air flow rate (550-828) CFM, suitable for operation on 230V,+_ 5% , 50Hz, 1Ph AC Supply. with precharged refrigerant, Wireless remote & all other accessories complete with refrigerent with 15 A Plug Top. PCB unit must be enclosed within metal enclosure. (Make - Mitsubishi Electric/ Daikin/ OGeneral/ Carrier/ LG/ Panasonic/ Johnson Controls (Hitachi) / Toshiba/Sharp/ Mitsubishi Heavy/Voltas)
Installation Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC Machine after making hole in wall etc as per direction of EIC including making arrangement for outdoor unit by suitable size angle iron frame as per direction of E.I.C
Supply and drawing 5/8" & 3/8" or 1/2" & 1/4" copper refrigerant pipes with 9 mm thick rubber nitrile rubber insulation an Al foil tape complete fittings Elbows, Bends, Supporting arrangement on walls along with other accessories on the surface of wall.
Supply and laying of 1.1 KV single core stranded 'PVC insulated FRLSH grade copper cable incl socketing, shaddling etc.as per direction of EIC ( Make : Finolex/ Havells/ Polycab/ KEI / RR or Brand approved by EIC) of requisite following diameter for the above Air-Conditioners as per direction of Engineer - In - Charge incl. necy. fittings as required as per G.S . [Power cable for connection betweeen indoor and outdoor units & also Control Cable for connection betweeen outdoor units to indoor ]
3 core x 4.0 mm² Round PVC insulated copper cable
4 core x 2.5 mm² Round PVC insulated copper cable
Supply & laying Drain Water piping work out of PVC / HDPE hard pipes of 25 mm dia. incl. fitting, accessories, bends, elbows, tees, flanges, tapings, wall sleeves, hangers, supports, anchors.
M/S. P K ENTERPRISE (BID ID -7800007)
RAJESH ENTERPRISE (BID ID -7800099)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
BOQ_2344196.xls
BOQ • 0.35 MB
WBF2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid