Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.6 LAccepted-AOC | ₹10.6 L | L1 | Accepted-AOC 1st lowest |
| 2 | L2₹10.7 L+₹8,171 (0.77%)Rejected-Finance 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹10.7 L+₹8,171 (0.77%) | L2 | Rejected-Finance Being not a lowest |
| 3 | L3₹11.0 L+₹38,255 (3.60%)Rejected-Finance | ₹11.0 L+₹38,255 (3.60%) | L3 | Rejected-Finance Being not a lowest |
| 4 | L4₹11.8 L+₹1.2 L (11.1%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹11.8 L+₹1.2 L (11.1%) | L4 | Rejected-Finance Being not a lowest |
| 5 | L5₹13.0 L+₹2.4 L (22.2%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹13.0 L+₹2.4 L (22.2%) | L5 | Rejected-Finance Being not a lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
11 Sept 2020, 6:00 pmClosed
GE WEST PATHANKOT
GE WEST PATHANKOT 145001
GE/PKT-23/2020-21 REPAIR/REPLACEMENT OF LT FEEDER PILLAR BOX/RMU PANELS/ MCCB AND ALLIED WORKS UNDER AGE E/M OF GE (WEST) PATHANKOT
2020_MES_371170_1
GE/PKT-23/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE WEST PATHANKOT
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE WEST PATHANKOT
₹50,000
Yes
26 Sept 2020
21 Aug 2020
12 Sept 2020
21 Aug 2020
11 Sept 2020
4 Sept 2020
Amount
Supply & fixing of MCCB 630 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 50 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 50 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 400 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 36 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 36 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 250 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 36 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 36 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 200 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 160 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 16 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 100% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 125 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 100 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Supply & fixing of MCCB 63 amp ,4 pole 415 volts ,3 phase ,50 Hz AC with thermal megnetic setting & 25 kA breaking capacity with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993(Latest Version). The MCCB should have Ics= 75% Icu for short circuit breaking capacity of minimum 25 kA rms at 415 volts 50 Hz AC. The MCCBs shall have spreader links and barriers as per standard feature of manufacturer.
Note :- For item No. 1.01 to 1.08 All MCCBs should be of suitable for unbalanced load.
(l) Supply and fixing Indicator lamp neon type red, yellow & blue complete all as spd and directed.
Material and labour for painting of LT panels/feeder pillar boxes outdoor /indoor type of any sizes or rating installed at varoius location under GE (wset) Pathankot with two coat of super enamell paint of approved colour with spray painting after cleaning the surface and preparing the same for painting complete all as specied and directed.
M & L for welding work to LT panels/feeder pillar box as per requirement at site to match with existing complete all as specified and directed.
M&L for MS sheet 3.15 mm thick for repairing existing damaged panel doors due to corrison of different type and sizes complete with hinges, hot, cold welding work,fabricating, locking arrangement etc as required including painting with one coat of red oxide and two coats of synthetic enamel paint complete all as specified and directed.
S&F of aluminium lugs of suitable for 50 Sqmm cable complete all as specified and directed.
S&F of aluminium lugs of suitable for 70 Sqmm cable complete all as specified and directed.
S&F of aluminium lugs of suitable for 95 Sqmm cable complete all as specified and directed.
S&F of aluminium lugs of suitable for 120 Sqmm cable complete all as specified and directed.
S&F of aluminium lugs of suitable for 150 Sqmm cable complete all as specified and directed.
M&L for cross arms bracing supports clamps, back plates fabricated from steel section incuding nuts,bolts and washers welding,drilling hole complete with two coats of aluminium paint over and including one coat of red oxide primer complete all as specified and directed.
Supply and fixing of copper strip of size 25 x 5mm with insulating sleeves complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6 mm by means of nuts bolts,washers, check nuts of GI steel all as shown in electric plate no 3 complete including a layer of charcoal dust, salt 15 cm thick all around the plate and GI protection pipe ,medium grade 40mm dia and GI watering pipe 20mm dia ,medium grade with funnel and wire mesh ,40mm thick pre-cast RCC M-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected complete all as specified and directed.
Supply,installation, commissioning & testing of bus bar chamber of size 600 x 400 x 250 mm made up of MS Sheet 3.15 mm ,powder quoted with RAL 7032 code ( Siemens Grey) and aluminum strip of size 50 x 6 mm -04 Nos (300mm long ) with 100 amps 25 kA FP MCCB along with spreaded Link for conection complete all as specfied and directed as per site requirment.
Supply,installation, commissioning & testing of bus bar chamber of size 600 x 400 x 250 mm made up of MS Sheet 3.15 mm ,powder quoted with RAL 7032 code ( Siemens Grey) and aluminum strip of size 50 x 6 mm -04 Nos (300mm long ) with 200 amps 25 kA FP MCCB along with spreaded Link for conection complete all as specfied and directed as per site requirment.
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for foundation of pole and laying of UG cable and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for Sand cushioning to under ground cable 8cm before laying the cable and 15 cm after laying and stretching the cable and punning down to 18 cm complete all as specified in clause 19.75 of SSR Part - I.
M&L for Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid complete all as specified and directed.
Supply, laying & testing of XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, in replacement of cross-sectional area 35 Sqm 3.5 core complete all as specified and directed.
All as per serial item No. 20 here-in-above but of 70 sq mm 3.5 Core
All as per serial item No. 20 here-in-above but of 95 sq mm 3.5 Core
All as per serial item No. 20 here-in-above but of 120 sq mm 3.5 Core
Supply, fixing and testing GI pipe light grade with all fittings for cable protection laid in trenches in road crossing/ fixed to wall/ pole of size 50mm bore complete all as specified and directed.
Supply, fixing and testing GI pipe light grade with all fittings for cable protection laid in trenchesin road crossing/ fixed to wall/ pole of size 80mm bore complete all as specified and directed.
(NOTE : Item Srl No 20 & 23 Earth work including excavation, returning Filling, removing, sand coushioning, brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule)
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 45,202.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 5% (Five percent) of the accepted contract sum shall be delivered by the successful bidder immediately from the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
malghotra construction co
JAI DURGA CONSTRUCTION CO
satpal and brothers
SATISH AND CO
dinesh enterprises
DASHMESH BUILDERS
ACESOLARR RENEWABLE ENERGY LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .