| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.8 LAccepted-AOC HOUSE NO 54 PUBERUN PATH HATIGAON GUWAHATI 781038 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹42.0 L+₹2.3 L (5.91%)Rejected-Finance PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹44.2 L+₹4.5 L (11.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹45.8 L+₹6.2 L (15.7%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹46.4 L+₹6.8 L (17.1%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
14 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
SPECIAL REPAIRS OF BLDG NO T-5, REPLACEMENT OF 04 NOS DAMAGED STORAGE TANK STAGING WITH CONNECTED WORKS BEHIND BLDG NO P-46, 47 AND PROVISION OF SEPTIC TANK, SOAKAGE WELL FOR TOILET BLOCK TB-6, TB-7 AT LEKHAPANI
2023_MES_609458_1
8748/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class D and category a (i)
9 documents required · 9 mandatory
₹500
GE LEKHAPANI
₹80,000
Yes
14 Sept 2023
17 Jul 2023
21 Aug 2023
17 Jul 2023
14 Aug 2023
31 Jul 2023
Amount
Dismantling of plain or corrugated steel sheeting any guage, thickness including Nanital or similar pattern roof coverings complete all as specified and as directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including frames and cover fillets complete all as specified and directed.
Dismantling wrought iron or mild ste complete all as specified and directed.el work of any description not otherwise provided for complete all as specified and directed.
Taking down roof trusses, coupled rafters or trussed beams of clear span above 4 mtrs and upto 8 mtrs complete all as specified and as directed.
Dismantling timber scantlings in unframed timber work 40 sq.cm and over in section, in any position complete all as specified and as directed.
Dismantling timber fillets,rails,posts,rafters,purlins,etc in un framed work under 40 sq.cm and over in section, in any position complete all as specified and as directed.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work & precast concrete articles,removing debris beyond the premises, complete all as specified and directed.
Demolition of unreinforced cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) removing debris beyond the premises complete all as specified and directed.
Demolition of RCC of any description in any position not otherwise specifically provided for removing debris beyond the premises complete all as specified and directed.
Demolition of RCC for water tanks at a height of 6 to 8 m including removing debris beyond the premises,complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundations,manholes,laying cables,pipe lines,etc and getting out in soft/ loose soil complete all as specified and directed.
Excavating over areas n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
All as per item No.13 above but exc 1.5 m deep and n. exc 3 m deep complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm of soft loose soil,complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L PCC (1:4:8), type D-2, (using 40mm graded stone aggregates) as in foundations, filling, mass concrete etc complete all as specified and directed.
M&L PCC ( 1:3:6) type C-2 (using 40 mm graded stone aggregate), as in foundations, bed concrete,filling sub base, surface channels and mass concrete,etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement, including forms, mouldgs mitred/stopped ends etc complete all as specified and as directed.
M&L Providing RCC M-25 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span etc complete all as specified and directed.
M&L RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in foundations, including rafts,footings,plinth beams; etc comlpete all as specified and directed.
M&L RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in slabs, supported on walls beams and columns in floors, roofs, landings, balconies, canopies, deck slabs,in shelves and the like including slabs of septic tank, soak well etc complete all as specified and directed
M&L Precast RCC M-25 (Design mix) (using 20mm graded stone aggregate) as in cover slabs for manholes, septic tanks,soakage well,etc and set in CM (1:4) with plain fair faces incl chamfered, weathering, throating etc incl necessary form work complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM (1:4) complete all as specified and directed.
All as per Item No.25 above but except bricks complete all as specified and directed.
M&L Brick work with sub class old size 'B' bricks, straight or curved on plan to any radius, built in CM (1:4) as in half brick thick walls complete as specified and directed.
M&L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in CM (1:4) complete all as specified and directed.
M&L Loose filling with broken brick aggregates of gauge 40 to 80 mm in soakage pit, soak well etc complete all as specified and directed
Use and waste of form work to sides of concrete foundation, footings, base of coloumns, raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Use and waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, for rough finished flat surfaces of concrete complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each and making good to disturbed surfaces complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkat or frame with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0sqm each and making good to disturbed surfaces complete all as specified and directed by the Engineer-in-Charge.
M&L Pressed steel frames (125 x 60mm) and 1.2mm thick for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed.
M&L PCC (1:3:6), type C-1, (using 20 mm graded crushed stone aggregates) as in bed block, blocks for holdfasts, filling in pressed steel door frames , benching slightly rounded or chamfered angles & throating etc including necessary use & waste of form work complete all as specified and directed.
S&F 30 mm thick, double leaf flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match & fixed to chowkats complete all as specified and directed.
S&F 35 mm thick, double leaf second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) fitted to chowkats complete all as specified & directed.
S&F 200 mm size, aluminium anodised , barrel tower bolts of extruded section & fixed complete all as specified and as directed.
S&F 150mm size aluminium handles, cast type, anodized and fixed complete all as specified & as directed.
S&F 300 mm length of bolt, aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified & as directed.
S&F Galvanised steel wire cloth. 0.56 mm nominal dia of wire and average width of aperture 1.18 mm fixed with steel wire staples complete all as specified and directed.
M&L Providing and fixing inter locking metal grid (snap grid for false ceiling) of size 605mm x 605mm in true horizonatal level, hot dipped galvanised steel sections consisting of main “T” runner with suitably spaced joints to get required length and size 24mm x 38mm made from 0.30mm thick (Min) sheet spaced at 1200mm centre to centre and cross “T” of size 24mm x 28mm made of 0.30mm thick (Min) sheet, 1200mm long spaced between main “T” at 600mm centre to centre to form a grid of 1200mm x 600mm and secondary cross “T” of length 600mm and size 24mm x 28mm made of 0.30mm thick (Min) sheet to be interlocked at middle of the 1200mm x 600mm panel to form grids of 600mm x 600mm and wall angle of size 24mm x 24mm x 0.4mm. Main “T” runner to be suspended from purlins or truss member using 2 to 3 mm dia GI wire, 1200mm x 600mm centre to centre all complete for all heights complete as per manufacturers specifications,as specified and as directed by Engineer – in - Charge.
M & L for 4 mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation ad acoustic purpose to be placed in grid system hold down clips with provision of high fixtures, air conditioning, diffuser and ducts, sprinkler, smoke detector etc,complete as per manufacturers specifications,as specified and as directed by Engineer – in - Charge.
S & F Aluminum powder coated (powder coated of required colour) three track sliding windows frame top & sides of size 92 x 31.75 x 1.50mm (section No 20831) bottom of size 92 x 31.72 x 1.50mm (Soction of 20832) and shutter top & bottom of size 40 x 18 x 1.55 (section 20738) and lock side shutter frame of size 40 x 15 x 1.45mm (Section 20737) with rubber gasket, beading and locking arrangement including making good to the disturbed portion complete including stainless steel wire mesh 0.36mm nominal dia with 1.40mm average aperture and fixed with stainless steel wire staples and fixing 5mm thick glass with necessary rubber beading gasket etc complete all as specified and directed by Eng-in-charge.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips,complete all as specified and as directed.
All as per Item No.46 above, but 6 mm to 8 mm dia complete all as specified and as directed.
All as per Item No.46 above,, but 5 mm dia and over upto and including 10 mm dia in stirrups, spacrs and binders.complete all as specified and as directed..
S&F Rolled Structural steel Fe 290 (Gde-E-165) in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc.complete all as specified and as directed.
S&F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cofirming to Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410 -W (GdeE- 250) quality A.complete all as specified and as directed.
Fixing only roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
S&F Mild Steel work in tubular trusses etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 confirming to grade St-240 complete all as specified and directed.
S&F Mild Steel work in tubular trusses (square/rectangular section) etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 4923-1997 (Reaffirmed 2009) grade Yst-310 complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n exc 10 cm long,diameter of neck 5 to 10 mm complete all as specified and as directed.
M&L for pre-painted hot dip aluminium-zinc alloy metallic coated corrugated steel sheet, any pattern corresponding to IS15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed
M&L for hot dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ 150, 0.50mm thick of an approved colour and having yield strength of 550MPa as in ridge/valley/gutter/eaves boardings fixed with self tapping screws as specified including necessary scaffolding and safety measures at any floor complete all as specified and as directed.
M&L for 50 mm thick PCC (1:3:6) type C-2 (using 40 mm graded stone aggregates) as in plinth protection etc, finishing cement concrete surface even and smooth with out using extra cement including making joints with hot bitumastic mix in proportion of bitumen and sand (1:2) complete all as specified and as directed..
M&L Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. including brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed.
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM (1:6) for laying floor finishes complete all as specified and directed.
M&L for coloured non skid joint free ceramic tiles of 7mm to 8mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 sqm in floors, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering in CM (1:4) for vertical surfaces such as skirting etccomplete all as specified and as directed.
M&L 40 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floors, finished even and smooth, using extra cement complete all as specified and directed.
M&L for Glass dividing strips, 3 mm thick 38mm wide and inserted in position, conform to design complete all as specified and directed
M&L Rendering 10.mm thick CM (1:6) on fair faces of brick work or concrete surfaces including finishing top even and fair complete all as specified and as directed.
M&L Rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surfaces in two layers 5mm thick finishing layer over 10mm thick backing layer finished fair and even with mixing water proofing compound to top layer as per manufacturers instruction complete all as specified and directed. Note: WPC will be measured separetely.
Supply only Integral water proofing compound of approval brand complete all as specified and directed.
M&L Preparation of new plastered surfaces of walls and applying 1 mm thick thin layer of exterior wall care putty and finally applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L Preparation of new plastered surfaces of walls and applying thin layer of wall care putty of 1 mm thick and finally applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L Preparing new wood & wood basd surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L Preparation of new or previously un treated steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L Preparation of old painted surfaces of steel of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Taking up or down 25 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F GI pipe 25 mm dia bore of pipes, (medium grade), galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Taking up or down 20 mm steel tubing and connections, including cleaning for refixing or removal to storecomplete all as specified and directed.
S&F GI pipes 20 mm dia bore of pipes, (medium grade), galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F GI pipe 15 mm dia bore of pipes, (medium grade), galvanised iron, with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of 1500 Ltrs capacity,(cylindrical vertical with closed top) multi layered hoisted and fixed in position all as specified in SSR part-I & as directed.
S&F 25 mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe & fixed (Minimum weight 210 gms) complete all as specified and directed.
M&L 25 mm dia Gunmetal globe/gate valve, ISI marked, with iron wheel head, screwed both ends complete all as specified and directed.
S&F PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) vent cowl fixed with pipe complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints,laying in trenches/floors complete all as specified and as directed.
S&F PVC (SWR) bends 110 mm dia any radius all as specified and directed.
M&L PCC ( 1:3:6 ), type C-2 (using 40 mm graded stone aggregate), as in bed to drain pipes of 110 mm bore including packing under and haunching against the sides of pipes after they are laid and tested,complete all as specified and as directed.
S&F PVC (SWR) pipes 160 mm dia single socketed, in any length with rubber ring joints, laid on trenches/floors repair complete all as specified and as directed.
M&L PCC ( 1:3:6 ), type C-2 (using 40 mm graded stone aggregate), as in bed to drain pipes of 160 mm bore including packing under and haunching against the sides of pipes after they are laid and tested,complete all as specified and as directed.
Taking down copper/aluminium point wiring, (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and as directed.
Material and labour for providing point wiring for controlled by one switch with using 1.50 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable (Maintaining Colour Code) 1100 volts grade with and including PVC casing and capping of suitable size including PVC accessories / fittings and fixtures fixed on surface with using new PVC board or sunken type pressed steel box of adequate size, terminal boxes for mounting fittings/junction boxes with and including all accessories and using 1.5 sq.mm (nominal area), stranded copper conductor, single core PVC insulated FRLSH unsheathed cable green in colour as in earth continuity conductor connected to common earth dolly and connecting upto fittings for one light point controled by one one way 5 Amp switch complete all as specified and directed. NOTE: The quoted rates shall be inclusive for fixing casing caping to surface with using PVC raw plugs and provision of PVC boards/terminal/junction boxes of any shape and size.
All as per Item No.89 above,but One fan point controlled by one , one way 5 Amp switch,complete all as specified and directed.
All as per Item No.89 above,but one 5 pin socket outlet 05 Amp on independent board,complete all as specified and directed.
All as per Item No.89 above,but one 5 pin socket outlet 05 Amp on same board,complete all as specified and directed.
All as per item No 89 above,but using 2.5 sq mm, copper conductor with 2.5 sq mm, PVC insulated single core cable for earth continuity conductor for one 15 Amps socket outlet complete all as specified and directed.
M&L for providing sub main wiring with two single core 6.00 Sqmm (nominal area) PVC Insulated FRLSH unsheathed multi stranded copper conductor cable 1100 volts grade drawing through PVC casing-capping complete including 6.00 Sqmm PVC insulated unsheathed multi stranded FRLSH single core copper conductor cable for earth wire including taking down/removing old one and making good distrubed surfaces of walls, floors, etc complete all as specified and directed. Note : (i) Three runs of single core 6.00 Sqmm multi stranded copper cable and one run of casing caping shall be measured as one run length (ii) Extra length of cable required for connection to DBs/MCBs shall deem to be included in unit rate quoted by contractor against the item (iii) Earth wire run inside the casing capping.
S&F Switch piano flush button, single pole, one way 5 Amp complete all as specified and directed.
S&F Socket outlet, 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed.
S&F Switch socket combination 2 in 1, 2 and 3 pin 5 Amp flush type complete all as specified and directed.
S&F Switch socket combination, 5 in 1, multipurpose 5/15 Amps flush type universal complete all as specified and directed.
S&F Ceiling fan regulator, electronic type, step type speed A/C, 230 volts complete all as specified and directed.
S&F MCB single pole (SP) 6 to 32 Amp 240 Volts 10 KA 'C' series with all incoming/outgoing connection with proper size lugs including taking down old unserviceable MCB SP complete all as specified and directed.
S&F MCB single pole and neutral (SP&N) 32 Amp 240 volts 10 KA 'C' series with all incoming/outgoing connections with proper size lugs including taking down old unserviceable MCB SPN, complete all as specified and directed.
S&F Single pole and neutral DB wall mounting type, 240 Volts, 12 Way with 200 Amps rated bus bar, double door suitable for fixing MCB's including connecting etc and taking down old un serviceable DB , main switch complete all as specified and directed.
S&F DB,SPN, wall mounting type, 240 Volts,8 Way with 200 Amps rated bus bar, double door suitable for fixing MCB's including connecting etc and taking down old un serviceable DB ,main switch complete all as specified and directed.
S&F Ceiling rose, 3 terminals, surface bakelite, /PVC/Polycarbonate.complete all as specified and directed.
S&F LED tube light fitting 4 ft. 1 x 18/20 watt with 230 volts, complete with all accessories internally pre-wired and fixed to walls/ceiling with screw including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F LED building security light fitting 1 x 35 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure diecast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection incl mounting bracket of suitable size and connection complete all as specified and directed.
Taking down existing ceiling fan from bldg and keep aside the serviceable ceiling fan for reuse and uncerviceable ceiling fan deposited to MES store complete all as specified and directed by Engr-in- charge.
S&F Ceiling fans complete with blades, down rods , and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) including down rod of suitable size bar and all fixing arrangements complete all as specified and directed. .
Refixing only serviceable celing fan complete all as specified and directed by Engr-in- charge
S&F Fan hook made of 10mm dia TMT Bar for for hanging the ceiling fan complete all as directed by Engr-in- charge
M&L for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class"B" laid dry and flat and width wise along the axis of the trench complete all as specified and as directed by Engineer-in-Charge.
M&L for sand cushioning in cable trenches over & under the cables, with river washed coarse sand, as per standard practice with proper compaction complet all as specified and directed by Engr-in-Charge. Note:Punned thickness shall be considered for payment.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core, including taking down old unserviceable cable complete all as specified and directed.
Supply and laying 40 mm dia GI tubing (light grade) with all fittings (ISI Marked) laid in trenches/fixed on pole/wall including taking down old unsv GI pipe complete all as specified and directed.
M&L Boring of holes under road, pavement, hard standing by using trenchless technology for passing the cable through GI pipe complete all as specified and directed by Engr -in-Charge. Note: GI Pipe shall be measred and paid seperately.
Material and labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover ( 1 : 2 : 4) type B1 (using 20 mm graded stone aggregate) with 3 Nos 8 mm dia TMT bars both ways and testing on completion complete all as specified and directed by Engineer-in-Charge.
RIA CONSTRUCTION
RC CONSTRUCTION
M/s Singh enterprises
M/S SINGH TRADERS
SAHASRA CONSTRUCTION
ADNEEDS ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .