Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹14.4 L+₹16,170 (1.14%)Rejected-AOC | L2 | Rejected-AOC Other than the lowest tenderer | |
| 3 | L3₹14.8 L+₹51,880 (3.64%)Rejected-AOC 546 14 JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | L3 | Rejected-AOC Other than the lowest tenderer | |
| 4 | L4₹15.0 L+₹75,070 (5.27%)Rejected-AOC | L4 | Rejected-AOC Other than the lowest tenderer | |
| 5 | L5₹15.7 L+₹1.5 L (10.3%)Rejected-AOC H NO 24 BEHIND GURUDWARA JUTOGH CANTT SHIMLA HP 171008 | SHIMLA | HIMACHAL PRADESH | 171008 | L5 | Rejected-AOC Other than the lowest tenderer |
Tender Value
₹14.6 L
EMD Value
₹29,200
Closing Date
11 Dec 2019, 6:00 pmClosed
GE JUTOGH
GE JUTOGH JUTOGH CANTT SHIMLA (HP) 171008
SPECIAL REPAIR FOR REPLACEMENT OF UNDERGROUND CABLE FROM MRS TO OFFICER COLONY UNDER GE JUTOGH
2019_MES_295388_2
GE/JUT-43/2019-20
Open Tender
Civil Works
Item Rate
180 days
JUTOGH
CLASS E CATEGORY b (i)
6 documents required · 6 mandatory
₹500
GE JUTOGH
₹29,200
Yes
15 Jan 2020
27 Nov 2019
13 Dec 2019
27 Nov 2019
11 Dec 2019
4 Dec 2019
Amount
Excavating in trenches n exc 1.5 m wide and n exc 1.5 m in depth, and getting out in hard/ dense soil oil for laying cables, errection of poles complete all as specified and directed.
M & L for sand cushioning/ sand covering for UG cable protection complete all as specified and directed
Supply & laying of sub class 'B' bricks locally available best quality laid flat (length of bricks laid across the length of cable) in tranches for protection of U/G cable all as specified and directed
Returning filling in , including spreading levelling, watering and well raming in layers n exc 25 cm complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at level not exc 1.5 m above the starting point complete all as directed
Taking down/ out existing unserviceable LT Cable of any size and type complete all as specified and directed.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)1100 Volts grade with stranded aluminium conductor of fwg size all as specified and directed.
240 sqmm 3.5 core
120 sqmm 3.5 core
70 sqmm 3.5 core
50 sqmm 3.5 core
35 sqmm 3.5 core
25 sqmm 3.5 core
Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm dia conforming to IS, approved colour complete with fittings for cable protection. Make Dura line /finolex/Tele Rex
All as per item No 08 above, but 50mm dia.
All as per item No 08 above, but 80mm dia.
Taking out old unserviceable GI Pipe any size and making good to the disturbed surface as per existing complete all as specified and directed.
M&L for GI pipe light grade of size 80mm dia laying in trenches/ under floor/on walls for protection of UG cables all as specified and directed
All as per item No 12.00 above, but size 50mm dia
All as per item No 12.00 above, but size 40mm dia
M & L for insertion of cable / GI Pipe under road/ pavements / hardstanding etc mannually by boring / cutting of road including making good to the disturbed surface by laying PCC, type B-1, up to the existing road surface complete all as specified and directed. Note : Cost of PCC shall be included in the quoted rate and cost of GI pipe shall be measued and paid seperately.
Supply installation testing and commissioning MFPB Panel board pillar box of suitable size out door type factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets on all sides and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessories at MFPB NEAR OQ 36 and taking down old unservicable Feeder pillar box
(a) INCOMING
MCCB 500 Amps AC 4 pole 415 Volt 50 KA breaking capacity as per IEC 60947-2 adjustable thermal magnetic trip unit (TMD) range 500 Amp - 01 Nos of Make : Schneider cat No LV563318 or equivalent in Legrand / ABB/Havells
(b) OUTGOING
MCCB 250 Amps, AC 4 pole 415 Volt 36 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 250 Amp - 04 Nos (Outgoing FP1,FP2,FP3 & SPARE,) of Make : Schneider cat No LV431640 or equivalent in Legrand / ABB/Havells
MCCB 160 Amps , AC 4 pole 415 Volt 36 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 160 Amp - 03 Nos (Outgoing for FP1 & 01 Nos spare )of Make : Schneider cat No LV430640 or equivalent in Legrand / ABB/Havells
MCB SPN 63 Amp - 10 of Make : Schneider Cat Part No A9N2P63C or equivalent in Legrand / ABB
Phase indicating lamp LED Type for incoming and each outgoing connections of Make : AE, L&T, Schneider
TPN 63 Ampre 3 pole & Netural Make: Schneider Cat pat no NX063TPNDI or equivalent in Legrand/ABB/Havells
Including PCC plateform in PCC : 1:3:6 of size 2m x 2m x 0.10m with base PCC 1:4:8 of size 2m x 2m x 0.10m
Base frame for cubical for mounting made out of 40 x 40 x 6 mm equal angle iron including 04 Nos MS Angle leg 1.5m long above the GL and 0.3 m Grouted in the PCC duly painted with two coats of synthetic enamelled paint over a coat a red oxide.
Foundation for the panel should provided with PCC 1:3:6 at a depth of 300 mm below G. L. and 100 mm above the G. L. with slot openings for I/C and O/G cables.
Supply installation testing and commissioning LT Panel board of suitable size out door type factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounting on suitable size foundation with 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets on all sides and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper bus Bar strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply including suitable size copper conductor control wiring, necessary cable glands, lugs etc, proper arrangement for ventilation with and including the following accessoreis and taking down old unservicable Feeder pillar box :-
(a) INCOMING
MCCB 250 Amps , AC 4 pole 415 Volt 36 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 250 Amp - 01 Nos of Make : C&S CAT Part No CSCN250TM*4P or equivalent in Legrand / ABB/Havells
(b) OUTGOING
MCCB 160 Amps, AC 4 pole 415 Volt 25 KA Breaking Capacity as per IEC 60947-2 adjustable thermal magnetic trip unit range 160 Amp - 06 Nos of Make :C&S CAT Part No CSE2250ATM4P-* or equivalent in Legrand / ABB/Havells
MCB SPN 63 Amp - 04 of Make : Schneider Cat Part No A9N2P63C or equivalent in Legrand / ABB//Havells for security light
Phase indicating lamp LED Type for incoming and each outgoing connections of Make : AE, L&T, Schneider
Including PCC plateform in PCC : 1:3:6 of size 2m x 2m x 0.10m with base PCC 1:4:8 of size 2m x 2m x 0.10m
Base frame for cubical for mounting made out of 40 x 40 x 6 mm equal angle iron including 04 Nos MS Angle leg 1.5m long above the GL and 0.3 m Grouted in the PCC duly painted with two coats of synthetic enamelled paint over a coat a red oxide.
Foundation for the panel should provided with PCC 1:3:6 at a depth of 300 mm below G. L. and 100 mm above the G. L. with slot openings for I/C and O/G cables.
S&F Busbar Chamber suitable size for set of 04 aluminium busbar 200 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 and taking down the existing unservicable bus bar chamber complete all as specified and directed.
M & L earthing complete for electrical equipments with galvanised steel earth plage electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.24 mtr below ground level with top edge earth plate at a depth not less than 1.5 mtr below ground level, connected to earth lead of GI strip size 25 x 4 mm by means of nuts, bolts, check nuts & washers made of galvanised iron or steel and connected to main switch board or main control board as directed charcoal or coke and salt in alternate layers, necessary excavation and earth work in hard/ dense soil coplete all other accessories as shown on electrical plate No 5 of MES SSR Part I including 50 mm bore light grade GI pipe 1.8 mtr length with top end covered with plug or cap for watering and 30 x 30 x 30 cm size PCC 1 : 3 : 6 block around watering pipe parallel to the existing earth, excluding 20 mm dia watering pipe, PCC, Watering pit, Funnel, Pit cover complete all as specified and directed. Note : Earth Strip upto 7.5 mtr will be included in the quoted rates.
CHADHA ENGINEERS
M/S kuldeep kumar khullar
M/s JAIMAA ASSOCIATES
M/S J.S.ENTERPRISES
R D Bansal
Babu Ram Sud and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .