| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHATRAPATI SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKTA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | ₹43.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹50.5 LRejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹50.5 L | L2 | Rejected-Finance Not Being L1 |
| 3 | Rejected-Technical FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | - | - | Rejected-Technical Not Meeting the eligibility criteria as per NIT |
| 4 | Rejected-Technical SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | - | - | Rejected-Technical Not Meeting the eligibility criteria as per NIT |
| Sl No | Description | Qty | Unit | sapana enterprises L2 | cooltech engineering services L1 |
|---|---|---|---|---|---|
| 1.00 | Supplying, assembling, installing, testing and commissioning of Cable Fault Locator Kit complete with on-site training, make: Telemetrics / Merytronic or equivalent, comprising the following:
(A) Pre-Fault Locator (Model: TFL 8)
(i) Two selectable work modes – Low Voltage Impulse method (TDR) & Impulse Current method (ICM).
(ii) Capable of locating faults in any type of metallic single-core armoured or multi-core armoured cables.
(iii) Cursor drag function for easy location.
(iv) Three windows for easy comparison in low impulse method.
(v) 7" colour LED screen, 160° viewing angle.
(vi) Compact, lightweight and user-friendly menu-driven operation.
(vii) Compatible with Surge Wave Tester.
(viii) Internal battery charge status display.
(ix) Intelligent charger for charging of internal batteries.
Note:
The complete assembling, installation, testing, and commissioning of the equipment shall be carried out through the OEM or authorised service providers, to ensure compliance with the manufacturer’s standards, and to the satisfaction of the Engineer-in-Charge/ GE. | 1 | Each job | 36,41,244 ₹36.4 L | 32,12,000 ₹32.1 L |
| 1.01(B) Surge Generator (Surge Wave Tester – 1000 Joules) (i) Pin-point location of cable faults in low and medium voltage cables by acoustic method. (ii) Output voltage selectable in three ranges: 4, 8, 16 kV. (iii) High energy capacity of 1000 Joules with full energy delivery at each selected range. (iv) Continuously variable output voltage from 0 to 100% of selected range. (v) Fully protected operation with safety interlocks. (vi) Pre-location of cable fault distance with suitable pre-locator unit in ICM mode. (vii) Easy connection with arc reflection filter for SIM mode pre-location. (viii) Automatic discharge facility for cable under test in case of power failure or after switching off. (ix) Continuous operation for extended periods for difficult faults. (x) Indications: ON/OFF lamp, analog moving coil meter for output voltage (kV), overheat indication. (xi) Overload protection: Input current limiter switch on mains supply and fast-blow fuse in controlled supply. (xii) Accessories: 5 m high-voltage output cable, 5 m earthing cable, 1 no. mains cord. (xiii) Earth discharge: Soft and automatic. (C) Surge Receiver – Pin Pointer (Surge Wave Receiver) (i) For pin-pointing cable faults by acoustic and magnetic methods. (ii) Guides operator along cable route while locating faults. (iii) Dual-channel LCD display for magnetic and acoustic signal strength. (iv) Separate sensitivity and volume controls for both channels. (v) Battery condition indication; (vi) Backlight facility for LCD. (vii) Automatic low-battery indication on LCD; (viii) Mute operation to eliminate external noise. (ix) Ambient noise-protected headphones. (x) High acoustic quality and noise immunity. (xi) Lightweight, compact receiver with high-sensitivity ground microphone. (xii) Power supply: 1.5 V × 8 AA size batteries. (xiii) Dual LCD bar-graph display for channel levels, battery check status, and peak-hold signal bar. | |||||
| 1.02(D) Cable Route Tracer (Model: MRT 500 – Merytronic) Receiver performance: Depth measurement up to 10 m. 7 internal sensors/antennas. Route tracing length over 10 km. Depth precision: <3% up to 2 m, <5% up to 10 m. Active frequencies: 640 Hz, 8 kHz, 32 kHz, CPS. Passive frequency: 50/60 Hz (no transmitter needed). Current direction: Continuous. Operation modes: Full, Max, Peak, Null. Operating time: 30 hours intermittent. Operating temperature: –20°C to +55°C. Display: 2D coloured LCD, sunlight-readable, graphical distance and angle to target. Battery: Li-Ion in both receiver and transmitter. Weight: 1.5 kg. Measurement units: cm/inches. Built-in antenna configuration with digital processing algorithm. | |||||
| 1.03Features: Sensors strategically distributed for cable highlight. Depth measurement accuracy (<3% up to 2 m; <5% up to 10 m). High precision (<5% in all axes). Detects 4 active and 2 passive frequencies. Measures depth and current amplitude. Capability up to 10 m depth; Sleep mode and auto power-off. Transmitter: 10 W adjustable power; Suitable for >10 km cable length. Rechargeable internal battery in both devices. | |||||
| 2.00 | Supply, installation, testing & commissioning of analog addressable fire alarm control panel complying with BS EN 54, single loop panel of capacity from 99 detectors & 99 modules up to 200 detectors and modules, expandable up to 6 loops, with LCD display and required power supply & batteries for 24 hours in normal operation and 15 minutes in fire condition, complete all as specified and directed.
Make: Edward EST-3/ Notifier or equivalent approved make . | 1 | Each | 3,96,480 ₹4.0 L | 2,47,660 ₹2.5 L |
| 3.00 | Supply, installation, testing & commissioning of active repeater panel to be integrated with addressable fire alarm control panels, with large display to show status of any fire/fault of integrated fire alarm panels, and to activate fire alarm sounders/sirens, complete all as specified and directed.
Make: Edward EST-3/ Notifier or equivalent approved make | 1 | Each | 87,910 ₹87,910 | 72,050 ₹72,050 |
| 4.00 | Supply, installation, testing & commissioning of network card to connect panels and repeater panel through RS-485 data configurable as master/slave, multiple master/slave, and peer-to-peer networking, complete all as specified and directed .
Make: Edward EST-3/ Notifier or equivalent approved make | 2 | Each | 41,300 ₹82,600 | 29,270 ₹58,540 |
| 5.00 | Material and labour for fire alarm sounders/sirens, electronic type, horizontal, two-stage, continuous normal operation for at least 50 minutes, with sound level 65 dB to 120 dB measured at 1.5 mtr, with sound output variation of ±5 dB over 500 mtr range, complete all as specified and directed. | 1 | Each | 4,130 ₹4,130 | 13,570 ₹13,570 |
| 6.00 | Supply and fix detectors complying with and type certified to EN-45, addressable type multi-sensor detector with heat and smoke combination as per IS:11360, complete all as specified and directed. | 5 | Each | 2,419 ₹12,095 | 3,080 ₹15,400 |
| 7.00 | Supply and fix addressable manual call point, resettable type, complete all as specified and directed. | 2 | Each | 3,245 ₹6,490 | 4,130 ₹8,260 |
Updated dates
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
7 Nov 2025, 6:00 pmClosed
GE (SB) KARWAR
GARRISON ENGINEER (SEABIRD) KARWAR Naval Base, Sankrubagh (PO) Karwar - 581308
PROVISION OF CABLE FAULT LOCATOR WITH ACCESSORIES FOR GE (SB) KARWAR AT NAVAL BASE, KARWAR AND PROVISION OF FIRE ALARM IN FDS VAJRAKOSH UNDER GE (SB) KARWAR
2025_MES_734387_1
8381/E8
Open Tender
Electrical and Maintenance Works
180 days
GE (SB) KARWAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (SB) KARWAR
₹95,000
Yes
6 Feb 2026
10 Oct 2025
10 Nov 2025
10 Oct 2025
7 Nov 2025
24 Oct 2025
10 Oct 2025 - 17 Oct 2025
Amount
(D) Cable Route Tracer (Model: MRT 500 – Merytronic) Receiver performance: Depth measurement up to 10 m. 7 internal sensors/antennas. Route tracing length over 10 km. Depth precision: <3% up to 2 m, <5% up to 10 m. Active frequencies: 640 Hz, 8 kHz, 32 kHz, CPS. Passive frequency: 50/60 Hz (no transmitter needed). Current direction: Continuous. Operation modes: Full, Max, Peak, Null. Operating time: 30 hours intermittent. Operating temperature: –20°C to +55°C. Display: 2D coloured LCD, sunlight-readable, graphical distance and angle to target. Battery: Li-Ion in both receiver and transmitter. Weight: 1.5 kg. Measurement units: cm/inches. Built-in antenna configuration with digital processing algorithm.
Features: Sensors strategically distributed for cable highlight. Depth measurement accuracy (<3% up to 2 m; <5% up to 10 m). High precision (<5% in all axes). Detects 4 active and 2 passive frequencies. Measures depth and current amplitude. Capability up to 10 m depth; Sleep mode and auto power-off. Transmitter: 10 W adjustable power; Suitable for >10 km cable length. Rechargeable internal battery in both devices.
Supply, installation, testing & commissioning of analog addressable fire alarm control panel complying with BS EN 54, single loop panel of capacity from 99 detectors & 99 modules up to 200 detectors and modules, expandable up to 6 loops, with LCD display and required power supply & batteries for 24 hours in normal operation and 15 minutes in fire condition, complete all as specified and directed. Make: Edward EST-3/ Notifier or equivalent approved make .
Supply, installation, testing & commissioning of active repeater panel to be integrated with addressable fire alarm control panels, with large display to show status of any fire/fault of integrated fire alarm panels, and to activate fire alarm sounders/sirens, complete all as specified and directed. Make: Edward EST-3/ Notifier or equivalent approved make
Supply, installation, testing & commissioning of network card to connect panels and repeater panel through RS-485 data configurable as master/slave, multiple master/slave, and peer-to-peer networking, complete all as specified and directed . Make: Edward EST-3/ Notifier or equivalent approved make
Material and labour for fire alarm sounders/sirens, electronic type, horizontal, two-stage, continuous normal operation for at least 50 minutes, with sound level 65 dB to 120 dB measured at 1.5 mtr, with sound output variation of ±5 dB over 500 mtr range, complete all as specified and directed.
Supply and fix detectors complying with and type certified to EN-45, addressable type multi-sensor detector with heat and smoke combination as per IS:11360, complete all as specified and directed.
Supply and fix addressable manual call point, resettable type, complete all as specified and directed.
Supply and fix addressable electronic sounder-cum-strobe, complete all as specified and directed.
Supply and fix remote response indicators, complete all as specified and directed.
Supply and fix short-circuit isolators, complete all as specified and directed.
Material and labour for 2 core, 1.5 Sqmm, multi-stranded copper armoured cable, complete all as specified and directed .
Supply and fix addressable control module, complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm × 600 mm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level), with top edge of plate not less than 1.50 m below normal ground level, connected to GI strip 25 × 4 mm as earthing lead by means of bolts, nuts, washers, and check-nuts, with GI welding at all joints, including excavation, earthwork in any type of soil, GI pipe (light grade) 15 mm bore for protection of GI wire from earth electrode to earth test point, earth test point of GI/steel 75 × 75 × 25 mm, laying of charcoal dust and common salt, PCC (1:2:4) type B-1 (using 20 mm graded aggregate) chamber, 40 × 40 × 3 mm MS angle iron frame, RCC cover 40 mm thick (1:2:4 using 20 mm graded aggregate) reinforced with 6 mm dia bars @ 75 mm c/c both ways, 12 mm dia round bar MS handle, PGI funnel, wire mesh, and 20 mm dia GI pipe (light grade) for watering, all as shown on plate No. 3 of SSR Part-I (2009) and connected to earth test point, including testing on completion, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide, not exceeding 1.5 mtr in depth, and not exceeding 1.5 mtr in length, for laying of LT underground cables/GI pipes, getting out in soft/loose soil, complete all as specified and directed.
Returning and filling in trenches using excavated soil, spreading, levelling, watering, and well ramming in layers not exceeding 25 cm deep complete all as specified and directed.
Removing excavated surplus material/ soil to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above starting point, complete all as specified and directed.
M&L for point wiring for 5 Amp socket on independent board, complete with 1.5 Sqmm two single-core PVC insulated, unsheathed, 1100 volts grade cable with stranded copper conductor, FRLS grade, conforming to IS-694 (Part II) with ISI mark, drawn through and including suitable size stove-enamelled steel conduit with all accessories, including suitable size sunk-pressed steel or cast-iron terminal box with 3 mm thick plastic laminated sheet top cover fixed flush with wall surface, by means of brass screws and sunk cup washers, for mounting of switches and sockets, including providing 1.5 Sqmm PVC insulated, sheathed, stranded copper conductor cable as earth wire, complete all as specified and directed.
Ditto as per item No.17 but with cables of 2.5 Sqmm size for 15 Amp socket on independent board, complete all as specified and directed.
Supply and fix flameproof switch socket and plug combination, LM-6 cable termination box, in LM-6, 6 Amp, 250 Volts, complete all as specified and directed.
Supply and fix flameproof switch socket and plug combination, LM-6 cable termination box, in LM-6, 16 Amp, 250 Volts, complete all as specified and directed.
Supply, installation, testing and commissioning of 500 VA UPS, 12 V, complete all as specified and directed.
Supply and laying of 25 mm dia GI tubing, light grade, with all fittings, for cable protection, laid in trenches or fixed on walls/poles, complete all as specified and directed.
sapana enterprises (BID ID -3469498)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.79 MB
Tender8381.pdf
Tender Documents • 0.74 MB
BOQ_822322.xls
BOQ • 0.70 MB
Download all tender documents and submit your bid