Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC NO 7A MULLAI NAGAR MAIN RD WEST TAMBARAM CHENNAI 600 045 | CHENGALPATTU | TAMIL NADU | 600045 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹33.2 L+₹8,887.40 (0.27%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹36.9 L+₹3.8 L (11.4%)Rejected-Finance NO 17 5 SOLOMON STREET ADHI NAGAR EAST TAMBARAM CHENNAI 600 059 | CHENNAI | TAMIL NADU | 600001 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹38.7 L+₹5.5 L (16.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹39.2 L+₹6.1 L (18.4%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹41.1 L
EMD Value
₹82,300
Closing Date
21 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
PROVN OF SECURITY LIGHTS AT DARK PATCHES OF MAIN CAMP AND CERTAIN SANCTIONED , MINOR WORKS AT AF STATION TAMBARAM
2023_MES_630441_1
GE(AF)/TBM/8685/E8
Open Tender
Civil Works - Others
Item Rate
120 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹82,300
Yes
10 Jan 2024
30 Nov 2023
23 Dec 2023
30 Nov 2023
21 Dec 2023
16 Dec 2023
1 Dec 2023 - 8 Dec 2023
Amount
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/dense soil all as specified and directed.
Excavation in trenches depth exceeding 1.5 m not exceeding 3.0 m deep and not exceeding 1.5 m wide and getting out in hard/dense soil all as specified and directed.
Returning filling in soil including providing cable cushioning with riddled earth obtained from excavation, leveling watering and well ramming in layers not exceeding 25cm thick over the cushion layer all as specified and directed.
Removing the excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supply, lay in trenches burnt Bricks, old size, Sub class "B" for cable protection all as specified and directed.
Supply and fix GI brackets made out of GI pipe 40mm bore ,1.50 metre long ,bend to shape required including necessary MS clamps ,nuts ,bolts etc required for fixing street light fitting on top of the poles all as specified and directed
S&F PVC junction box out door type of size 280 mm x 170 mm x 130 mm with front openable hinged cover complete with two number aluminium bus bars mounted on porcelain insulator including clamps of MS flat iron 25 x 3 mm with bolts and nuts to fixed on pole/wall incl taking down of old U/S all as specified and directed. (Make: SINTEX or equivallent)
S&F in replacement of street light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LED as light source with 60 W LED lamp complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core all as specified and directed.
M&L 40mm dia GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes all as specified and directed.
M&L for 20 mm dia GI tubing light grade with all necessary fittings including wooden plugs at end for sealing laid in trenches fixed to walls, poles,under road/floor etc for cable protection complete all as specified and directed.
M&L for PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed
PCC 1:3:6, type C-1, using 20 mm graded stone aggregate as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair all as specified and as directed
S & F three core PVC insulated copper conductor 1.5 sqmm for making connection from light fitting all as specified and directed.
M&L for Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for embedded portion complete all as specified and directed. Note : Excavation & earth work and PCC shall be measrued and paid separately.
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion
M&L for plain cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in foundation/ coping of poles road cutting including necessary form work and finishing the exposed concrete surfaces even and fair all as specified and as directed
Supply and laying LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning of 3.5 core 95 sqmm cable all as specified and directed. Note: [a] Earth work, excavation sand cusioning, bricks for protection etc shall be measured separately under relevant items of this schedule .
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 32x6mm GI strips means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion
Supply and fix automatic transfer switch execution rated voltage 415V AC 50 HZ type FP 200 Amps all as specified and directed by the Engineer-in-charge including taking down existing main switches Make : Havells cat part No IHYFCDO200 or its equivalent make from list of makes.
M&L for MCCB 4 pole, 415 volts Magnetic thermal setting adjustable 70-100% type, 200 Amps with breaking capacity 36 KA all as specified and directed.
M&L for chemical earthing ( maintenance free) ring earth consisting of four Nos 17.2mm dia and 3 mtr long electrode of low carbon steel eloctrode of permissible distance between each electrode with 250 micron copper bonding and 25 kg bag of Jef Eco safe compound for each earth pits based environment friendly backfill enhanching compound should strictly be a Eco safe carbon based conductive concrete type which has resistivity of less than 0.12 Ohm Mtr as per Cluse 14.5D of IEEE : 80 standard, back fill compound shoud be electronically conductive ( like in metals) and should not depend on moisture for conduction. Back fill compound shall be environmentally friendly, should solidify when mixes with water and set like concrete and should not leach/ diffuse into the ground and the back fill compound shall not be mixed with soil while pouring into the bore hole.Test certificate as per IEC 62561-7 for back fill compound shall be submitted along with materials. The Eco friendly rust proof heavy duty weather proof polyethylene earth pit chamber with following dimensions 254mm dia (top), 330mm dia ( bottom) and 260mm ( height) . The copper strip of 25x3mm shall be incorporated for interconnection of earth pits all as specified and directed.
Sl.item No. 23 Contd/… : Notes:- ( i) Earth resistance value shall be less than 0.50 Ohms. (ii) 25mm x 3mm x 300mm copper bus bar - 02 Nos. (iii) Earth conductor copper strip 25x3mm upto 7.5 Mtr is inclusive in quoted unit rate. (iv) Display board ( eath pit maker) made out of 25mm angle frame with 45cm height one side welded with 2mm thick MS sheet, frame work of size 15cmx 15cm including excavation, PCC foundation and duly painted with red oxide and two coats of red coloured synthetic enamel paint with following letters on display on white paint :- (a) Earth Pit No. (b) Earthing Resistance. ( c) Check done on ___. (d) Check due on ____.
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L providing plain cement concrete 1:2:4, type B1 ,using 20 mm graded stone aggregate as in cills, steps, bands, copings, bed plates , etc including necessary form work, all as specified and as directed
M & L rendering 20 mm thick in CM 1 : 4 on brick wall surfaces or concrete surfaces complete all as specified and as directed
Material and labour for preparation of new plastered surfaces of walls by brooming down with using broom/sand papering or by any other mean, washing down with water and applying two coats of cement base paint over a coat of primer as per approved tint/colour all as specified and directed
M&L for Hardcore of gauge not exc. 63mm, deposited, spread and levelled in layers not exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for moorum/red bajri filling in floor in layers not exc 15cm and rammed complete all as specified and as directed.
M&L for RCC 1:2:4, Type B2 using 20 mm graded stone aggregate, as in slab , thickness as directed at site all as specified and directed.
M&L for stone Boulder filling dry, hand packed tightly, as in wire crate apron bunds (Wire crate measured separately)
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work finished fair ,exceeding 20cm wide, complete all as specified and directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia,complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided forcomplete all as specified and as directed
Dismantling asbestos cement (corrugated, semicorrugated, etc) sheets in roof coverings as directed
Dismantling of wooden scantling of size more than 40 sqcm all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed.
Demolition of Brick work built in cement mortor all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and as directed
All as per item No 40 here in before but plain sheet as in ridge sheet having width 600 mm or as required at site.
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Confirming to FE-410-W (Grade E-250 quality - A) all as specified and directed.
S&F Structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde-E- 250) quality-A complete all as specified and as directed
M&L Preparation of old steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint complete all as specified and as directed
M&L preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed
S&F Mild steel work as in wind ties and similar work for roof including securing bolts; etc including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
S&F Anodised aluminium snap grid frame of grid size 605 x 605mm work for false ceiling all as specified and directed.
M&L for 12mm thick Perforated particle board/ tiles for insulation and accoustic purposes, 60x60 cm in size, fixed with screwes to aluminum frame work or with staples on snap grid, if the ceiling is flat or sloped all as specified and as directed.
Dismantling and refixing of false ceiling boards of any description and any position etc, all as specified and as directed.
M&L Rendering 10mm thick on fair faces of brick work or concrete internal surfaces in CM 1:6 complete all as specified and as directed
M&L Preparation of new plastered surfaces of walls and applying three coats of white wash on walls complete all as specified and as directed
M&L Rendering 15mm thick CM 1:6 on fair faces of brick work or concrete external surfaces complete all as specified and as directed.
M&L providing plain cement concrete 1:2:4, type B1 (using 20 mm graded aggregate) as in cills, steps, bands, copings, bed plates etc including necessary formwork all as specified and as directed
Cutting holes in to brick wall built in cement mortar exc half brick & n.exc full brick and making good in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified and as directed
M&L for preparation of old decorated wall surfaces and applying one coat of cement based paint all as specified and as directed
Dismantling of exisiting ceiling fans/ceiling lights carefully and refixing the same in the same position incl wiring,fittings etcof any description and any position all as specified and as directed.
M&L for Complete removal of existing treatment of Internal walls and applying two coats of distempering with 1st quality acrilic distemper over coat of primer and applying plaster of parris putty 1mm thickness over plastered surfaces even and smooth complete all as specified and directed
Supply only Unskilled labour for maint of Air field lighting system at AFS Tambaram consists of Air field lights, control cables, Isolation transformers, IT chambers, Landing TEEs, Wind Sockers etc including connected works on daily basis or on requirement basis per 8 hours shift between 0700 hrs to 1800 hrs complete all as directed. ( Note : The number of labour supplied will be as per requirement basis.Contractor shall maintain a attendance register duly signed by Engr-In-Charge and Contractor Rep. Labour should report to BCR section on time. Reporting time will be decided by BCR section as per the ground requirement with in the time period as mentioned above.)
Supply and fixing 450mm sweep Hi-Speed wall mounted fan of model Airboll Hi speed of Havells or its equivalent in other makes of Bajaj/ Polar/ Orient/ Khaitan/ Crompton.
S.M.THIYAGARAJAN AND CO
kcs builders
M R Govinda Reddy and Sons
M/s Bakiyalakshmi Enterprises
M/s. V. BAKTHAVATSALAM & CO
Varsa Constructions
kvs constructions
SRI LAKSHMI ASSOCIATES
JVM Construction
RAVI ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .