Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹29.9 L+₹2.4 L (8.75%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L2 | Rejected-Finance other than lowest bidder | |
| 3 | L3₹36.4 L+₹8.9 L (32.3%)Rejected-Finance | L3 | Rejected-Finance other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Due present residual work exceeds in terms of NIT note No 1. |
| Sl No | Description | Qty | Unit | M/S KEWAL KRISHAN SANJEEV KUMAR VAID L3 | M/S AKHILESHWAR ASSOCIATES L1 | NATIONAL TRADING COMPANY L2 |
|---|---|---|---|---|---|---|
| 1.00 | Attending complaints for checking of existing electrical points wiring in any Buildings/Pole for continuity ,no light including carrying out minor repairs etc as required to make the item functional and replacing burnt wire ends, small pieces of wire, tightning of loose connections etc all as specified.
Note - Contractor has to deploy Qualified Electrician and Helper with all necessary tools on all days to the complaint cell and complaints will be attended on the same day itself. Recovery for non attending complaints will be three times rate quoted by the Contractor. | 200 | Each Job | 150 ₹30,000 | 60 ₹12,000 | 35 ₹7,000 Lowest |
| 2.00 | Dismantling and taking down the existing defective street light/security light fitting of any type and any capacity fixed at any height by replacing UNSV part including perpex cover checking loose connection etc, restroration of electric supply, detecting and repair of UG cable fault whenever required round the clock all as directed at site on daily complaint basis. | 325 | Each Job | 150 ₹48,750 | 70 ₹22,750 | 45 ₹14,625 Lowest |
| 3.00 | S&F in repairs 45 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 50 | Each | 1,900 ₹95,000 | 1,800 ₹90,000 Lowest | 1,900 ₹95,000 |
| 4.00 | S&F in repairs 60 watt of new street light/security light incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 45 | Each | 2,000 ₹90,000 Lowest | 2,500 ₹1,12,500 | 2,150 ₹96,750 |
| 5.00 | S&F in repairs 100 watt of new street light/security light incl making electric connection using two run of 2.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. | 20 | Each | 2,500 ₹50,000 Lowest | 3,000 ₹60,000 | 2,800 ₹56,000 |
| 6.00 | S&F Indus series Powder coated pressure die cast alluminium compact high power LED flood light/security light fittings with heat resistant toughned glass with lense having 90 Watt including making electric connections using two run of 2.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. | 60 | Each | 2,500 ₹1,50,000 Lowest | 3,200 ₹1,92,000 | 2,900 ₹1,74,000 |
| 7.00 | Material and labour for repair to existing LED street light fitting 45 Watt to 60 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 50 | Each | 250 ₹12,500 | 120 ₹6,000 Lowest | 2,000 ₹1,00,000 |
| 8.00 | Material and labour for repair to existing LED street light fitting 90 Watt to 100 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 70 | Each | 250 ₹17,500 | 140 ₹9,800 Lowest | 2,356 ₹1,64,920 |
| 9.00 | Material and labour for repair to existing LED Flood light fitting 100 Watt of any make including supply and replacement of driver and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge. | 30 | Each | 300 ₹9,000 | 180 ₹5,400 Lowest | 2,500 ₹75,000 |
| 10.00 | S&F Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistranded and one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.) | 90 | RM | 200 ₹18,000 | 130 ₹11,700 | 28 ₹2,520 Lowest |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
23 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Jammu
GE AF Jammu
REPAIR REPLACEMENT SECURITY LIGHTS AND MISC WORK AT SHASHITHAR AND SALYARCHATTA UNDER GE AF JAMMU
2025_MES_742549_1
CA NO GE/AFJ-68/2025-26
Open Tender
Civil Works
Item Rate
180 days
SALYARCHATTA AND SHASHTAR
pls refer tender document
8 documents required · 8 mandatory
₹500
GE AF JAMMU
₹74,000
Yes
26 Feb 2026
2 Dec 2025
30 Dec 2025
2 Dec 2025
23 Dec 2025
16 Dec 2025
Outgoing: (a) MCCB having current carring rating 100 Amp with rupturing capacity 25 KA , AC 415 Volts three pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 02 Nos.) Make : L&T D-sine (CM9161200K00G) or equivalent of make Legrand / ABB / Havells. (b) MCCB having current carring rating 32 Amp with rupturing capacity 25 KA , AC 415 Volts three pole, Ics = 100% of Icu with adjustable thermal magnetic release complete with spreader links. (Qty- 10 Nos.) Make : L&T D-sine (CM9161200E00G) or equivalent of make Legrand / ABB / Havells.
Dismantling and taking down the existing defective street light/security light fitting of any type and any capacity fixed at any height by replacing UNSV part including perpex cover checking loose connection etc, restroration of electric supply, detecting and repair of UG cable fault whenever required round the clock all as directed at site on daily complaint basis.
Supply and fixing in repairs Rigid non-metallic PVC conduit 25mm dia (Heavy duty) in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed.
S&F Indus series Powder coated pressure die cast alluminium compact high power LED flood light/security light fittings with heat resistant toughned glass with lense having 90 Watt including making electric connections using two run of 2.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge.
S&F Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistranded and one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.)
Preparation of old painted surface of 9 m steel tubular poles above the top of PCC coping. Painting of pole from top of coping to a height of 1.5m (bottom portion of pole) with two coats of synthetic enamel paint in black and yellow alternate strip and painting the rest portion of pole of (approx length 7 m)including painting of cross arms/clamps/GI pipe breaket etc complete with two coats of synthetic enamel aluminium paint and to the entire satisfaction of Engineer-in-Charge complete all as specified and directed
Servicing of industrial RO at Shashithar and Salyarchatta 23 Wing AF including carrying out maintenance and check alongwith following repairs (a) Drain out the pipe and Replace new pipe and fixing the same.(c) Cartridge (d) Check tightness of all fitting Note:- Any minor/major parts such as screws,fillet,membrane, washers,PVC fitting etc shall be supplied by the firm, rate for the same shall be deemed to be excluded in the unit rate quoted.
S&F in repair controller control module panel for diesel generator DSE7320 with manual /auto electronics suitable for 40 to 160 KVA DG Set complete all as specified and as directed by Engr-in-Charge.
Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu.
Note :- (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid Aluminium conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4 incl masonary work leaving ducts for cables complete all as directed. (vii) All MCCBs have Ics= 100% Icu.
Supply , laying , testing & Commissioning UG cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core including taking down old cable with suitable thimbles complete all as specified and directed by Engr-in-Charge.
Description all as per item No-34 but size 25sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per item No-34 but size 35sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
Description all as per item No-34 but size 50 sq mm, 3.5 core complete all as specified and directed by Engr-in-Charge.
Re-Laying only of serviceable LT UG cable of any size and type in trenches, floors, across road crossing, or fixed on poles, walls with clam, or passing through pipe, complete all as specified and as directed. Note:- i). Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate .
Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, 'O' Ring etc, for protection of cable complete all as specified and as directed.
Ditto all as per items No 48 but of size 77mm outer dia and 63mm inner dia
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables complete all as specified and as directed by Engr in charge. Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard dense soil complete all as specified and as directed by Engr in charge.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
M&L for PCC 1:3:6 type C-2 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work i.e road cutting to aachieve fair finishes surfaces, complete alal as specified and directed.
Supply and laying of 15 mm CPVC pipe SDR 11 & plain CPVC SDR 11 fitting including making connection with existing line including all accessories and fixing on wall and ground/ceiling or laying in floor complete including taking out old rusted/broken GI pipes, complete all as specified and as directed by Engr-in-Charge.
S&F in replacement outdoor type Tiranga LED Rope light suitable for 9/11 mtr electric PCC/Steel Pole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction box complete all as specified and directed by Engr-in-Charge.
S&F in repairs thermostat for solar water heateing plant sutable size and rating etc complete all as specified and as directed by Engr in charge.
S&F in repairs copper wire 1.5 Sqmm FRLS green/red colour single core complete all as specified and as directed by Engineer-in-Charge.Anchor/Havells/Polycab (Note;- PVC Conduit will be Measure and paid seperatly as relevent item.)
S&F in repairs copper wire 2.5 Sqmm FRLS green/red/black colour single core complete all as specified and as directed by Engineer-in-Charge.Anchor/Havells/Polycab (Note;- PVC Conduit will be Measure and paid seperatly as relevent item.)
S&F ceiling fan complete with aluminium blades, down rods, 230V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) all as specified and as directed by Engineer-in-Charge.
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed cable copper conductor with size 04 Sqmm and drawing through & including Non metallic PVC conduit concealed in wall including earth continuity conductor of size 04 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge.
Servicing of diesel engine generating set capacity upto 160 KVA repair/replacement of the following defective parts through authorised service engineer/mechanic . (a) Drain out the lubricanting oil from sump and refilling after proper cleaning. (b) Replace Engine Oil filter cartidge with same size. (c) Renew Fuel filter cartridge with same size. (d) Check tightness of all nuts and bolts. (e) Check adjustment of V belt for driving engine water pump and alternator. (f) Assembling complete old serviceable parts and replacement of old unserviceable parts by new one as per direction of Eng
r-in-Charge. (g) Testing of DG set after servicing as per Engr-in-Charge. (h) Cleaning of air cleaner filter after period of hrs run as specified by manufactures in manual. (Note : (i) Any minor parts such as screw, washers , split pin , circlip etc shall be supplied by the firm , rate for the same shall be deemed to be included in the unit rate quoted. (ii) The job shall be carried out after two, hundred hrs run/ as when required directed by Engr-in-Charge of DG set and shall be measured and paid separately, no of times carried out during entire period of contract . (iii) During servicing of engine oil shall be issued by Department.
S&F in repairs capacitor of 2.5 Mfd. AC 230/240 volts, 50 Hz complete all as specified and directed by the Engineer-in-Charge.
SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
tender68.pdf
Tender Documents • 1.75 MB
BOQ_831508.xls
BOQ • 1.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .