Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹100.0 LAccepted-AOC NO 46 2 K D S ILLAM ARUNAGIRINATHAR STREET CHENNIMALAI POST ERODE DISTRICT 638 051 | ERODE | TAMIL NADU | 638051 | ₹100.0 L Quoted ₹1.1 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹3.1 L (2.92%)Rejected-AOC NO 167 1 MUTHUGOUNDENPALAYAM RING ROAD KUMARAPALAYAM ERODE 638 104 | ERODE | TAMIL NADU | 638104 | ₹1.1 Cr+₹3.1 L (2.92%) | L2 | Rejected-AOC Rejected |
Tender Value
₹1 Cr
EMD Value
₹60,000
Closing Date
23 Apr 2025, 3:00 pmClosed
Chief Engineer
Office of Chief Engineer, Sardar Patel Road, Dote Campus, Chennai 25
Providing Lift and External lighting arrangements to Extension of FERE Building in Anna University, Chennai 25
2025_HE_547635_1
FERELift_2025
Open Tender
Electrical Works
Lump-sum
180 days
Chennai
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹60,000
2 Jul 2025
17 Apr 2025
24 Apr 2025
17 Apr 2025
23 Apr 2025
17 Apr 2025
Amount
Supply, Erection, Testing, Commissioning and Handing over of 1No 13 Persons capacity Passenger Lift (SS304 grade) gearless without machine room as per the following technical specifications which includes all taxes and duties. Technical Specifications: 1) Locations:- G+2 building 2) No. of Lift: One No. 3) Type of Lift : Passenger Lift 4) Capacity of lift: 13 persons 5) Speed : 1.25 mtr/sec 6) Type of Drive: Microprocessor V3F. 7) No. of floor Ground + 2 floors 8) Total Travel: 8 mtrs (approx) 9) Leveling Accuracy: High level accuracy with smooth & jerk free stopping 10) Construction of car: Stainless steel hairline finish with direct lighting with new beautiful single tube false ceiling with tubular handrail on three sides, 300mm sweep Central fan 11) Position of Machine :Directly above the Lift level 12) No. of Landing Entrance – One in front 3 Nos 13) No of Car Entrance: One in front only. 14) Car Entrance Door:- Glass doors centre opening auto door with SS frame in each door. 15) Landing Entrance Door:- V3F Drive side opening sliding glass door with provision for emergency key opening at all landing. 16)Carsize : 1500 x 1400 mm 17)Car Clear Opening: 900mmx2100mm 18)Lift Well size : Existing 2700mm wide x 1900mm deep
19) Lift pit depth:-1600mm 20) Power supply: 400/440 V Three phase 50Cy/Sec A.C.supply and 230V 50 Hz single phase AC supply for light. 21)Control: Micro computer based Simplex full collective control with/without attendant. 22)Car fittings: Compact fluorescent lighting with 2Nos 300mm sweep fans. 23) Lift Well: RCC Construction with brick masonry. 25) Indication: Up/ Down Digital direction and position indicator for all landing and in car. 26)Emergency alarm bell:-Battery operated alarm bell to be provided with automatic charging device. 27)Emergency light : Battery operated light to be provided with automatic charging device. 28)Fire man’s switch ;To be provided at Ground Floor 29)Minor builders work: To be provided by Lift Contractor. 30)Scaffolding : To be provide by lift contractor 31) Stainless steel sill angles and facia plates. 32) Steel for lift Machinery :To be provided by lift contractor 33)Servicing and Maintenance: Free comprehensive servicing and maintenance should be provided by lift contractor during the guarantee period of one year 34)Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of power failure.
35)Provision of Intercom with Phone: To be provided by lift contractor. 36)Lift license : Preparation of drawing payment of charges to CEIG and Insurance policies and obtaining CEIG safety certificate as per lift act should be done by lift contractor 37) Floor annunciator with music 38) Special Features. (a). Infra red door sensor with full height screen. (b). Full width half height rear panel Mirror. (c). Tubular stainless steel handrail on three sides in car. (d). Voltage stabilizer for circuit control. (e). Stainless steel signal fixtures. (f). Vandal proof S.S button with S.S Cover. Lift buttons with Braille codes and handicap sign. (g) Stainless steel door frames for landing doors (h) VF door operator. (i) Call register Signal (j) Stainless steel fascia plate for car operating panel and landing fixtures. (k) ON-OFF switch for fan & light (l). Over load warning indicator. (m) Pit Ladder
39) Over speed governor, phase failure and phase reversal relay, alarm bell, T guide brackets for car and counter weight. Rubber padding under winding unit. Motor of adequate capacity, electromagnetic brake with compression springs, car safety gears, buffers, electro mechanical door locks. Emergency key. Side supporting angles motor over load protection devices, final limit switch main suspensions ropes, counter weights, lifting joint joist mounting the machineries. 40) Guarantee: Guarantee for the materials and workman ship of equipments complete should be offered by the Lift firm for a period of not less than one year. 41)Site testing in accordance with IS 14665 should be carried out at the time of handing over. 42) Providing Architraves by supply and fixing for all landing door entrances. etc., complete complying with standard specification and as directed by the departmental officers. (Make:Johnson / KONE equivalent)
Air Conditioning Arrangements: Outdoor unit: Supply and installation of 26HP VRF outdoor units equipped with hightly efficient invertor scroll compressors, modular special acrylic precoated heat exchanger, low noise condensor fan, auto check function for connection error, auto address setting, with multiple outdoor units, including providing gas charging, pressure testing, leak testing, complete including cartage etc. as required. Refrigerant shall be R410A and all compressors shall be of inverter type only for better efficiency. The part load under normal operating conditions etc., complete complying with standard specification and as directed by the departmental officers. Make : Bluestar/Toshiba/Daikin/ Samsung/LG/Hisense
Outdoor unit: Supply and installation of 24HP VRF outdoor units equipped with hightly efficient invertor scroll compressors, Modular special acrylic precoated heat exchanger, low noise condensor fan, auto check function for connection error, auto address setting, with multiple outdoor units, including providing gas charging, pressure testing, leak testing, complete including cartage etc. as required. Refrigerant shall be R410A and all compressors shall be of inverter type only for better efficiency. The part load under normal operating conditions. etc., complete complying with standard specification and as directed by the departmental officers.Make : Bluestar/Toshiba/ Daikin/Samsung/LG/Hisense
Supply erection, testing and commissioning of 1.5 TR (4500 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of Cooling Dehumidifying AirCirculating Filtering The installation works for the above split type AC units includes the following. 1.Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/O General) etc., complete complying with standard specification and as directed by the departmental officers.
Supply of 4 KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration etc., complete complying with standard specification and as directed by the departmental officers.
Supply erection, testing and commissioning of 2.0 TR (6000 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of Cooling. Dehumidifying. Air Circulating Filtering The installation works for the above split type AC units includes the following. 1.Mounting / Fitting Indoor and outdoor units at their respective locations. 2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required. 3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing. 4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit. 5. Leakage testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electric wiring to be provided with 2.5 Sq mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit (Make: Carrier/Voltas/equivalent) etc., complete complying with standard specification and as directed by the departmental officers.
Supply of 5 KVA Electronic Automatic Voltage Stabilizer (Higher end) with Input Voltage range of 170 Volt – 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of water drain pipe line (1" PVC pipe) etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of MS stand for fixing Outdoor unit etc., complete complying with standard specification and as directed by the departmental officers.
Supply and laying of 5/8" and 3/8" copper refrigerant pipe of 0.8mm thick with 2.5 sqmm 3 core chord between indoor and outdoor unit. (Extra beyond 3 mts supplied with AC unit) etc., complete complying with standard specification and as directed by the departmental officers.
supply and fixing of 65 mm dia. (2 -1/2") GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 48W LED street light fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED steet light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour etc., complete complying with standard specification and as directed by the departmental officers.
Supply and laying of 4 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good etc., complete complying with standard specification and as directed by the departmental officers.
Supply and clarnping of 4 x 10 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of brass cable gland for 4 x 10 sq.mm PVC armoured LTUG cable with earth connection etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of Rectangular Modern LED Chandlier fitting hanging Suspension 25W LED on Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. etc., complete complying with standard specification and as directed by the departmental officers.
Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box on wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of WT bulk head fitting with guard suitable for 15W LED bulb with 15W LED bulbetc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure Distribution board with IP 42 protection metal door type with 1No 16 Amps DP MCB & 1No 63A 4P MCB as incoming and 2 Nos 6A to 32A SP MCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISI mark (Like Legrand / Hager/ Equiv make) (Lift DB)etc., complete complying with standard specification and as directed by the departmental officers.
Supply and run of 2 of 1.5sqmm (22/0.3)PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 1.5 sqmm. Copper wire with painting of suitable colouretc., complete complying with standard specification and as directed by the departmental officers.
Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe on wall and ceiling with continuous earth wire connection of 10 sq mm copper wire with painting of suitable colouretc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of 32A FP MCB in suitable sheet steel enclosures on wall with earth connection and inter connections(Legrand /Hager) etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of Weather proof SMC Box outside size of 388 x 304 x 150 and Inside of 350 x 250 x 138 Single Door with Connections with 4 pole 125A MCCB with connection etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of 12 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCB Incomer ) with double door (metal door) with 1 no. 125 A 4P MCCB as incoming and 12 nos. 32A 3P MCB as outgoing with suitable cable end box on wall with earth connection only. Higher Endetc., complete complying with standard specification and as directed by the departmental officers.
Supply, Erection, Testing and commissioning of 315A capacity Dust and Vermin Proof Cubical Panel Board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting fuse switches with MCCB switches arranged in two Horizontal or vertical rows with one switch over the other with a central bus bar chamber and two nos of Horizontal or vertical cable chambers at the two ends one on each side next to the fuse switch chamber and confirming to IE rules. 1. 315A FP MCCB (L&T DN series/ Equiv) - = 1 no 2. 250A TP MCCB (L&T DN series/ Equiv) - = 1 no 3. 160A TP MCCB (L&T DN series/ Equiv) - = 5 nos 4. 125A TP MCCB (L&T DN series/ Equiv) - = 2 nos 5. 63A TP MCCB (L&T DN series/ Equiv) - = 2 nos (All the MCCB switches should be Siemens/L&T make only) The bus bar chamber will consist of suitable size of copper flat for phase and neutral buses on epoxy moulded bus insulators at proper and sufficient spacing between the buses as per IE rules. This bus bar chamber should be segregated from the adjacent chambers by providing hylem sheet of suitable thickness as partisans suitable size of copper flats should be provided all round the panel for earth bus.
The MCCB switches should be connected with the phase and neutral buses with suitable size of rigid copper rod or flat and each switch should be connected with 2 nos. 25x3 mm earth bus with 2 runs of No:8 SWG rigid copper rod with suitable lugs. Phase and neutral copper buses should be tinned properly. The panel should have a separate metering chamber at the top side consisting of Digital Multifunction meter Model LT MFM 4405 LED meter Cl 0.5/ like and CT arrangements LED indicator lamps should be provided with control switches and fuse units. The panel should be painted with one coat of Red oxide as primer coat and two coats of enamel paint of approved colour, Approved by the site engineer and also the danger board. The capacity of fuse switches, size of the incoming and outgoing cables, the place to which the supply is fed shall be marked on switch chamber. The panel board should be mounted on suitable MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at the height of 0.75m from the ground level. etc., complete complying with standard specification and as directed by the departmental officers.
Supply, Erection, Testing and Commissioning of 400A capacity Dust and Vermin Proof Cubical Panel Board made up of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting MCCBs arranged in two Horizontal or Vertical rows with one switch over the other with a central bus bar chamber and two nos. of Horizontal or vertical cable chambers at the two ends one on each side next to the switch chamber and confirming to IE rules. INCOMER: 1. 400A FP MCCB 36KA (L&T DN Siemens/equivalent) = 1 no OUTGOING: 2. 315A TP MCCB 36 KA (L&T DN Siemens/equivalent) = 1 No 3. 160A TP MCCB 36 KA (L&T DN Siemens/Equivalent) = 6 Nos 4. 125A TP MCCB 36 KA (L&T DN Siemens/equivalent) = 2 Nos
The panel should be painted with one coat of Red oxide as primer coat and two coats of enamel paint of approved colour, Approved by the site engineer and also the danger board. The capacity of fuse switches, size of the incoming and outgoing cables, the place to which the supply is fed shall be marked on switch chamber. The panel board should be mounted on suitable MS channel provided all round at bottom of the panel. The whole arrangement should be erected on a masonry pedestal to be constructed with suitable foundation bolts and nuts such that the lowest switch handle is at the height of 0.75m from the ground level etc., complete complying with standard specification and as directed by the departmental officers.
Supply and Run of 4 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour etc., complete complying with standard specification and as directed by the departmental officers.
Supply and clamping of 31/2 x 70 sq.mm PVC LTUG armoured LTUG armoured cable on post or on wall with MS Clamps etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of brass cable gland for 31/2 x 70 sq.mm PVC armoured LTUG armoured cable with earth connectionetc., complete complying with standard specification and as directed by the departmental officers.
Supply and providing cable end termination of 3 1/2 x 70 sq.mm PVC LTUG Aluminum armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete etc., complete complying with standard specification and as directed by the departmental officers.
Supply and Laying of 2 Runs of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goods etc., complete complying with standard specification and as directed by the departmental officers.
Supply and clamping of 2 Runs of 3 ½ x 150 sq.mm PVC LTUG armoured cable on wall with M.S. special clamps etc., complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of brass cable gland for 3½ x 150 Sq.mm PVC armoured LTUG armoured cable with earth connection etc., complete complying with standard specification and as directed by the departmental officers.
Supply and providing cable end termination of 3½ x 150 Sq.mm PVC LTUG aluminium armoured cable with necessary aluminium cable socket by crimping etc., with electrical connection completeetc., complete complying with standard specification and as directed by the departmental officers.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry etc., complete complying with standard specification and as directed by the departmental officers.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection etc., complete complying with standard specification and as directed by the departmental officers.
Supply and run of 1 of NO: 8 SWG cu wire for earth connection etc., complete complying with standard specification and as directed by the departmental officers.
Preparation of Electrical schematic diagram, site plans, physical layout 10 copies for all buildings in the campus and payment of CEIG documentation charges submission of completion report, rectification report, obtaining drawing approval, safety certification etc., complete including lamination copy fixed at EB room including payment of CEIG inspection fees etc., complete complying with standard specification and as directed by the departmental officers.
Sub Total
BLUELEAF PROJECTS PRIVATE LIMITED (BID ID -1313348)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .