| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.4 LAccepted-AOC A 8 SAKHARAM GANESH DAUSKAR SARANI KOLKATA 700 025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹48.0 L+₹2.6 L (5.73%)Rejected-Finance | L2 | Rejected-Finance Higher quoted rate. | |
| 3 | L3₹48.0 L+₹2.6 L (5.78%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L3 | Rejected-Finance Higher quoted rate. | |
| 4 | L4₹55.5 L+₹10.1 L (22.3%)Rejected-Finance | L4 | Rejected-Finance Highest quoted rate. | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to insufficient documents . |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
11 Jun 2025, 2:00 pmClosed
SE, PWD, Kolkata Electrical Circle
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Repair and Renovation work for Minerva Theater Hall - EI, Stage-Lighting, A.C System, Fire Detection, Servicing and allied works-SITC of Ductible Air-conditioning System.
2025_WBPWD_848691_1
PWD/SE/KEC/NIT-03/25-26
Open Tender
A/C ORG
Item Rate
60 days
Minerva Theater Hall
Please refer Tender documents.
8 documents required · 8 mandatory
₹1.2 L
31 Jul 2025
19 May 2025
13 Jun 2025
19 May 2025
11 Jun 2025
27 May 2025
Amount
S & delivery of ceiling suspended ductible type split airconditioner having microprocessor based control system and the following specification: Capacity-17 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity -204000 BTU/Hr No. of IDU-1 No Air-flow/IDU-6600CFM or higher. No of ODU-1 or 2nos with P2 type capacitor. Compressor -2 Nos Scroll Compressor Refrigerent -R410A/407C Condenser & Cooling Coil:Copper coil Power Supply :415v, 50Hz,3 Ph AC (with applicable tolarance) (Make-Carrier /Voltas/Blue Star /DAIKIN )
S & delivery of ceiling suspended ductible type split airconditioner having microprocessor based control system and the following specification: Capacity-11 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity -132000 BTU/Hr No. of IDU-1 No Air-flow/IDU-4400CFM No of ODU-1 or 2nos with P2 type capacitor. Compressor -2 Nos Scroll Compressor Refrigerent -R410A/407C Condenser & Cooling Coil:Copper coil Power Supply :415v, 50Hz,3 Ph AC (with applicable tolarance) (Make-Carrier /Voltas/Blue Star /DAIKIN )
S & delivery of ceiling suspended ductable type split air conditioner having microprocessor based control system and the following specification: Capacity-8.5 Tonnage (upto+1TR acceptable) Rated Cooling Capacity -102000 BTU/Hr No. of IDU-1 No Air-flow/IDU-3400CFM No of ODU-1 or 2nos with P2 type capacitor. Compressor- 1 or 2 Nos Scroll Compressor Refrigerant -R410A/407C Condenser & Cooling Coil: Copper coil Power Supply: 415v, 50Hz,3 Ph AC (with applicable tolarance) (Make-Carrier /Voltas/Blue Star /DAIKIN)
S & delivery of ceiling suspended ductible type split airconditioner having microprocessor based control system and the following specification: Capacity-5.5 Tonnage (upto +1 TR acceptable) Rated Cooling Capacity -66000 BTU/Hr No. of IDU-1 No Air-flow/IDU-2200CFM or higher. No of ODU-1 Compressor -1 No Scroll Compressor Refrigerent -R410A/407C Condenser & Cooling Coil:Copper coil Power Supply :415v, 50Hz,3 Ph AC (with applicable tolarance) (Make-Carrier /Voltas/Blue Star /DAIKIN )
Installation,Testing Commissioning charges (both indoor & outdoor unit) by making suitable scaffolding arramgement as per site condition incl. nitrogen flashing ,leak testing, vaccuming, gas charging etc. as per direction of EIC 17 Tr AC machine
11 Tr. AC machine
8.5 Tr AC machine
5.5 Tr AC machine
Supply, installation,testing and commisioning of Copper Refrigeration pipe line for Liquid Line suitable for the above ductible ac units with supports & brackets (as per direction of E.I.C.) incl. 13mm thick nitrile rubber insulation with proper tapping and mending good damages to original finish. Make of Cu Pipe - Rajco / Ryoku/ Mandev/Nippon Make of Insulation - Suprime / Accroflex / Armacell. 22.2mm dia with 0.6mm thick
28.6 mm dia with 0.6mm thick
34.9mm dia with 0.6mm thick
15.8mm dia with 0.6mm thick
Supply ,laying and Terminations of Following size PVC insulated & sheathed copper armoured control Cable (Make : Polycab/Havells/RR Kabel) 6C 2.5 Sqmm armoured cable
Earthing with 8SWG GI wire as to GS
S & charging of extra refrigerent 410A/407C as per manufacturer guide line.
Supply & installation of PVC Drain Pipe Line 32 mm OD,HD 1 mm thick with 6 mm nitrile rubber insulation and with proper supports & brackets as per direction of E.I.C. (Make: Suprime/Oriplast)
40mm dia PVC pipe (Make: Suprime/Oriplast)
50mm dia PVC pipe (Make: Suprime/Oriplast)
Air Distribution System Supply,fabrication and installation of GSS sheet metal ducts (rectangular/ round) and plenum chamber complete with necessary MS supports , hangers anchor bolts, supply air collars, vanes, splitters dampers duly painted and as per specification for Air Conditioned Areas. 22 SWG sheet
24 SWG Sheet
20 SWG Sheet
18 SWG Sheet
Supply & Fixing of powder coated extruded Aluminium Continuous Grill. (Mk. System Air/ Premire /Air Master/Carryair)
Supply & Fixing of powder coated extruded Aluminium return air diffuser without volume control damper (Mk. System Air/ Premire /Air Enterprise/Carryair)
Supply & Installation of fresh air arrangment with aluminium louvers & bird screen complete as required.
Supply & Installation of GI collar damper as per drawing.
Supply & fixing acoustic lining of supply air duct and plenum with 25mm thick resin bonded glass wool having 1.25 mm thick, density 32Kg/m² with 25mm x25mm GI section at 600 mm centre to centre to centre with reinforced plastic tissul paper and 0.5mm thick perforated aluminium sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc completed as per direction of EIC. (Make- Acroflex,K-flex.)
Supply & fixing of 19mm thick class O fire retardent nitrile rubber Aluminium foil face thermal insulation on duct with adhesive for nitrile rubber. The joints shall be sealed with 50mm wide & 3mm thick self adhesive nitrile rubber tape insulation complete as per direction of EIC.
Supply & Fixing of 22 SWG GI aerofoil blades type Duct Volume Control Dampers complete with linkages, levers, fittings, supports, all accessories any other item required to make the system complete as per direction of E.I.C.
Charges for canvas connection with machine and duct as per direction of EIC.
Dismantling of existing units:- Dismantling of existing 02 nos 5.5 TR, 02 nos 11 TR and 09 nos 8.5 TR Ductable package units.
Less Cost of Dismantled AC machines: Less cost for existing 5.5 Tr Ductible package unit
Less cost for existing 11 Tr. Ductible package unit
Less cost for existing 8.5 Tr. Ductible package unit Note: N.B: (a) The Agency must procure the materials from the Manufacturer / OEM or from their authorized sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (b) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. (c) If any refurbished material is supplied and installed, penal action will be taken as per existing rules. (d) Rates are inclusive of all taxes and duties including GST & LWC.
MAXCOOL REFRIGERATION CO. (BID ID -6483811)
REFRIGERATION AND AIRCONDITIONING CORPORATION (BID ID -6508443)
Scientific Refrigeration (BID ID -6469145)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .