MR Yognarayan sahu(DFLT)
CE(Ambikapur)
STRENGTHENING AND UP-GRADATION OF STATE GOVERNMENT MEDICAL COLLEGE FOR INCREASE IN UG/MBBS SEATS FOR GOVT. MEDICATL COLLEGE AT AMBIKAPUR (C.G.) (DEPOSITE WORK) (Without Escalation and Bonus)
198168
NIT NO: 854/TC/2026-27
OPEN TENDER
WORKS
PERCENTAGE
18 days
CE(Ambikapur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
OPEN TENDER
PERCENTAGE
OPEN TO ALL
CE(Ambikapur)
PWD Circle, Ambikapur
Division Ambikapur
120
18
No
0
198168
15 Sep, 2026 5:00:00 PM IST
18 Sep, 2026 10:00:00 AM IST
24 Aug, 2026 5:00:00 PM IST
NIT NO: 854/TC/2026-27
STRENGTHENING AND UP-GRADATION OF STATE GOVERNMENT MEDICAL COLLEGE FOR INCREASE IN UG/MBBS SEATS FOR GOVT. MEDICATL COLLEGE AT AMBIKAPUR (C.G.) (DEPOSITE WORK) (Without Escalation and Bonus)
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
396742000.00
2
17 Sep, 2026 5:00:00 PM IST
396742000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
24d 1h 4m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
21 Aug 2026
21 Aug 2026
18 Sept 2026
24 Aug 2026
17 Sept 2026
Removing wooden boarding in lining of wall and partition (excluding supporting members) including stacking within 50 metres lead. Thickness above 25mm. & upto 40mm.
Dismantling G.I. sheet roofing including ridges hips, valleys and gutters etc. and stacking the material with 50 m lead.
Dismantling steel work in built-up section in angles, channels, flats I section and T-section including all gusset plates, bolts, nuts, cutting rivets, welding etc., including dismembering and stacking within 50 metres lead.
Extra for dismantling steel work for every additional span of one metres of part thereof beyond 10 metres.
Demolishing brick masonry including arches, stacking of serviceable material disposal of unserviceable material within 50 metres lead. In cement mortar.
Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material within 50 metre lead
Demolishing cement concrete including disposal of material within 50 metre lead. 1:3:6 or richer mix
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. In all types of soils. In all types of soils.
Extra for every additional lift of 1.5 m or part thereof. All types of soils
Ordinary or hard rocks upto 1.5M to 3.0M
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers eacht exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers eacht exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor)Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor)Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand
Carriage by mechanical transport upto 5 km lead:Earth
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, forFoundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Columns, Pillars, Piers and likes- rectangular or square in shape
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Beams, lintels, cantilevers & walls
Weather shade, chhajja, Cornices and mouldings
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Extra for providing fixing and removing of propping from lower floor upwards for the concreting. Propping should be provided two floors below. The props of lower floor must be 50% of the props of the floor above including wedging etc. complete. In case propping is done in one floor below, only half the rate shall be paid.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm eachminal size).
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm eachminal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work.M-20 Grade
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm Eachminal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. M-25 Grade
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:Ground floor
1st Floor
2nd Floor
3rd Floor
4rth floor
FIFTH FLOOR
Making 50mm thick plinth protection of plain cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone aggregate 20mm eachminal size) over 75mm bed of dry brick ballast 40mm eachminal size well rammed and consolidated and grouted with sand including finishing the top smooth.
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete Thermo-Mechanically treated bars FE 415
1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size).
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:
Providing and laying water proofing treatment in sunken portion of WCs, bathroom, kitchen etc., by applying cement slurry mixed with water proofing cement compound consisting of following applications including surface preparation: i) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound@ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment on roofs, balconies, terraces etc with average thickness of 120mm and minimum thickness at khurra as 65 mm, consisting of following operations including surface preparation:Applying cement slurry on R.C.C. Slab or cement concrete work using 2.75 kg/Sqm. for receiving cement concrete floor including roughening, cleaning etc complete. ii) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) mixed with water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) mixed with water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.
Brick work with modular well burnt clay bricks of crushing strength not less than 35 kg/sqcm and water absorption not more than 20% in foundation and plinth in: Cement Mortar 1:4 (1 Cement : 4 Coarse Sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: (d) Cement mortar 1:6 (1 cement : 6 sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: (d) Cement mortar 1:6 (1 cement : 6 sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in foundation and plinth in: (d) Cement mortar 1:6 (1 cement : 6 sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:F.F
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth:S.F
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand)
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level: Cement Mortar 1:3 (1 cement : 3 coarse sand)
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:Cement Mortar 1:4 (1 cement : 4 coarse sand) FOURTH FLOOR
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level:Cement Mortar 1:4 (1 cement : 4 coarse sand)
F.F. Floor
2nd Floor
3rd Floor
Extra for providing and placing in position hopping 25x1.60 mm or 2 Eachs 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing and laying AAC Autoclaved aerated concrete block confirming to IS: 2185 (Part-3)-1984) in block masonry with AAC blocks of width 100/ 200mm height 200/250/300mm, length 400/500/600 mm (approved sizes) with cement mortar 1 :6 (1 Cement :6 coarse sand) in superstructure. AAC blocks should have specific gravity 0.6 to 0.65 and crushing strength should Eacht be less than 3 N/ sqmm (testing as per IS: 6441 - 1972).
Providing and fixing in position doors, windows and ventilators frames made of cold rolled pressed steel sheet framed profiles made from commercial M.S. Sheets confoMetering to I.S. 513 of 1973 and as per general specifications of I.S 4351 including hinges jamb, lock jamb, steel butt hinges, base tie, joints mitred and welded with 10cm long legs of size 15x3mm M.S. flat, embedded in cement concrete blocks 15x10x10cm size of grade M-10 or rawl plugs and screws or with fixing clips or with bolts and nuts including neatly compacted filling M-10 cement concrete in profile section applying a priming coat of red oxide zinc chromate primer Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet
Single rebate/ mullion 100mmx50mm size, 1.6mm thick sheet
Providing and fixing Dash fastener (for fixing door/ window frames) on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Dash fastener 12x100mm
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges.(b) 35 mm thick (single leaf)
Providing and fixing 30mm thick wire gauge shutter having top and style rail 95mm width, bottom and lock rail 197mm width, using galvanized M.S. wire dia of 0.45mm for doors, windows, clerestory windows excluding hinges Bijasal, Haldu, Benteak, Khair
Extra for double leaf shutter instead of single leaf.35 mm thick (Double leaf)
Extra for cutting rebate in flush door shutter (total area of door shutter to be measured).
12 mm thick pre-laminated particle board with one side decorative and other side balancing lamination, flat pressed 3 layer & graded (medium density) Grade I, Type II conforming to IS : 12823 (exterior grade).
12mm thick pre-laminated particle board flat pressed with decorative lamination on both sides exterior Grade - I MDF Board 12 mm thick confirming to IS:14587.
12 mm thick solid PVC sheet with decorative lamination on both sides of approved quality and make
Providing and fixing commercial grade water proof ply for wall paneling on 19 mm
Providing and fixing approved shade veneering on wood wall paneling complete as required. 6mm
Providing and fixing sliding arrangement in racks/ cupboards/ cabinets shutter by P/F stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately)
wooden frame with necessary
nails complete as required.
Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 300 x 16 mm
Providing and fixing brass door latch with brass polished MS screws complete: 300x16x5 mm
Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete:b) 250 x 10mm
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. 35 x 6 mm size
Providing and fixing aluminium door latch with 12mm rod, necessary nickel plated iron nuts bolts and screws etc complete.
Providing and fixing aluminium sliding door bolts with 16mm rod, necessary nickel plated iron nuts bolts and screws etc complete.250x16mm
Providing and fixing aluminium tower bolts (Barrel type) with necessary nickel plated iron screws etc complete. 250 x10mm
Providing and fixing powder coated aluminium door handles 2.5mm thick with necessary M.S. screws etc complete. 125mm
Providing and fixing powder coated aluminium door mounted door stopper with necessary M.S. screws etc complete. 50 mm long
Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete. Triple strip vertical type.
Providing and fixing special quality bright finished brass cupboard or wardrobe locks with four levers including necessary screws etc. complete (best make of approved quality) 65 mm
Providing and fixing antique/ SS finished brass sliding door bolt with necessary bolts, nuts and antique/ SS polished MS screw complete:
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. Sal, bijasal, benteak, khair, haldu
Providing and fixing wall paneling frame made of commercial grade 12mm thick water proof ply strips 100mm wide at 600mm apart center to center vertically and horizontally with necessary screws, wooden plugs etc complete as required.
Providing and fixing decorative curtain rod assembly made of 32mm dia aluminium pipe covered with decorative finish plastic sleeve, 2 Nos or more 100x50x20mm size decorative wooden bracket, 2 Nos 100x50mm dia decorative wooden rod holding end plugs and 50mm dia wooden curtain rings 1 nos for every 100mm of length of curtain rod including PVC rawl plugs etc complete:
Providing and fixing of bright finished brass mortise latch and lock 100x65mm with six levers and a pair of lever handles with brass polished MS screws etc. complete.
Providing and fixing Indian teak plywood 4 mm thick in partition including fixing to frames with brass screws etc. complete with 50x12mm teak wood beadings (frames to be paid separately).
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position Teak wood
Providing and fixing cupboard shutters 25mm thick, with Pre- laminated flat pressed with decorative lamination one side and other side balancing lamination exterior Grade - I MDF Board 25mm thick confirming to IS:14587 including IInd class teak wood lipping of 25mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges complete as per direction of the Engineer-in-Charge.
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc .complete.
Providing and fixing powder coated telescopic drawer channels with necessary screws etc. complete as per directions of Engineer-in- charge. 400 mm long
Providing and fixing antique/ SS finished brass handles with antique/ SS polished MS screw complete: 125 mm
Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
Providing and fixing antique/ SS finished brass tower bolts (Barrel type) with antique/ SS polished MS screw complete:
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats orsquare or round bars welded to steel frame of windows etc. includingapplying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.
Supplying and fixing rolling shutter of approved makes made of M.S. laths interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and out side locking with push and pull arrangement complete but excluding the cost of top cover and spring. 80x1.25mm M.S. Laths
Providing and fixing 27.5cm long wire spring for rolling shutters.
Providing and fixing M.S. sheet top cover for rolling shutter 1.25mm thick
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) confoMetering to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for arately:
For fixed portion
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Extra for powder coated (minimum 50 micron) aluminium sections instead
Extra for polyester powder coated (minimum 50 micron) aluminium sections instead of anodized.
9.50.2 Providing and fixing 12mm thick pre-laminated particle board flat pressed with decorative lamination and balancing lamination on specified sides exterior Grade – I MDF Board 12 mm thick confirming to IS:14587, including fixed in aluminium doors, windows shutters and partition frames with C.P. brass/ stainless steel screws etc. complete. With decorative lamination on both side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness
Providing and fixing laminated glass sheet of 8.76mm thickness in approved sizes on aluminium frame work on face of building. (Frame to be paid for separately).
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete SS Grade 304
Extra for providing and fixing tinted glass panes in aluminium door, window, ventilator shutters and partitions instead of float glass.5 mm thickness
Extra for providing and fixing reflective glass panes in aluminium door, window, ventilator shutters and partitions instead of float glass.
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame o be paid separately4 mm thick
Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel, sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete.
Providing 10mm thick plaster of paris (Gypsum anhydrous) ceiling height of 5m. above floor level over strips (Sal, Bija, Haldu) 25x6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed into wooden frame (Frame work to be paid separately) Flat surface
Providing and fixing special designer glass film over glazed doors windows and partition etc
Providing and fixing clear float toughened glass door or partition is required thickness frameless in appropriate sizes inclusive of edge moulding polished and making required size slot togather 1. 10 mm thick for door partition
Three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed and one no. wire mesh panels) made of ( big series ) frame 116 x 45 mm and sash 46 x62 mm both having wall thickness of 2.3 +-0.2 mm and single glazing bead / double glazing bead of appropriate dimension . ( area of window above 1.75 sqm )
Providing and making 6mm thick cement plaster of mix: In Cement mortar 1:3 (1 cement : 3 fine sand)
Providing and making 12mm thick cement plaster of mix: In cement Mortar 1:4 (1 cement : 4 fine sand)
Providing and making 12mm thick cement plaster of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Neat Cement punning.
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: In Cement Mortar 1:6 (1 cement : 6 fine sand)
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer.
Providing and mixing in cement mortar, triangular polyester fiber Recron 3s (Anti-shrinkage Admixture) of 6 mm length of approved make like Reliance industries Ltd etc. in proportion as recommended by manufacturer.
Extra for plastering of exterior walls when height exceeds 10m above ground level for every additional height of 3.0m or part thereof.
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:Drip course
Providing and fixing chicken mesh weighting Eacht less than 250 gms/ sqm as per IS : specification in the required width with 40mm long steel nails on vertical and horizontal surface near R.C.C. and brick walls junctions including scaffolding and all lead and lifts etc. complete before plastering upto 10mts in height.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 50 mm thick
Providing and fixing rectified glazed ceramic wall/dado tiles of 1st quality conforming to IS: 15622-2017 of approved make, in all colours, shades on wall and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size 300x450mm thickness 7 to 8mm
Providing and laying Glazed Vitrified wall/dado tiles (GVT/ PGVT) with digital print of random design with water absorption less than 0.08% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) for wall /dado laid on 12mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.Size 600x600mm thickness 9 to 10mm
Providing and fixing rectified glazed ccramic Floor tiles of 1st quality conforming to IS: 15622-2017 of approved make, in all colours, shades over 20 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with matching pigment complete. Size 600×600mm thickness 8 to 9mm
Providing and laying DOUBLE/ MULTI CHARGE (minimum 2.0mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm thickness 9 to 10mm
Providing and laying DOUBLE/ MULTI CHARGE (minimum 2.0mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS: 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. Size 800x800mm thickness 9 to 10mm
12.65.2 Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm Pigment Coloured (rubber mould) precast interlock concrete blocks
Chequered terrazzo tiles 22 mm thick with graded marble chips of size upto 6mm in floors on 25mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including grinding rubbing and polishing complete.Light shade pigment with white cement
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)Granite stone black
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above)Granite stone lakha red/ shahi red
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m)
Granite stone black
Granite stone lakha red/ shahi red
15mm thick Granite work (machine cut, table rubbed & mirror polished) for wall lining (veneer work) in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing with cement mortar 1:2 (1 white cement: 2 marble dust) mixed with matching pigment. (Area of slab should be over 0.5 sqm). Granite stone lakha red/ shahi red
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish.Granite stone black
Extra for making opening of required size & shape for wash basins/kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including making necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Stone work with KOTA STONE Slab (machine cut edge) exposed face machine cut and table rubbed with rough backing for wall lining etc. (Veneer work) upto 10 metre height, backing filled with a grout of 20 mm thick cement mortar 1:3 (1 cement: 3 coarse sand), jointing with cement mortar 1:2 (1 cement: 2 stone dust) with admixture of pigment matching the stone shade including rubbing and polishing complete. (To be secured to the backing by means of cramps which shall be paid separately) 40 mm thick
Extra for nosing in Granite stone for treads.
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
EXTRA FOR NOSING IN TREAD AND STEPS IN KOTA STONE
Extra for necessary grinding and polishing to get mirror finish on KOTA/ Marble Stone flooring/ steps/ treads instead of eachrmal grinding and polishing.
Providing and applying Polymaric cement primer on all surface applied @ 0.80 litrs/10 sqm as per relevant IS. code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare , Dulux interior cement primer, Opus Calista / I10) with all tool tackles and labour etc. complete for the work
Providing and applying 2mm thick Acrylic white cement based grade putty with minimum 3 coats applied @ 4.0 kg/ 10Sqm as per relevant IS code 17545:2021 (Product such as Asian trucare, Berger Happy walls Putty Birla Opus One pro smooth) to make the surface smooth and even with all tools tackles and labour etc. complete for the work . (This Item to be use in heigher grade painting works Item No. 14.65)
Providing and applying Acrylic washable Distemper or lite cconomy Plastic emulsion paint having VOC content less than 50gms/ lit Minimum two coats up to final finish applicd @ 1.25 Kg/ 10Sqm as per relevant L.S. Code 428:2000 (product such as Tractor Uno, Dulux Duval, Berger Bison, Opus Style/lite economy emulsion product such as Asian Tactor Spark Dulux Pomise sheen, Neroloc Litil Master, Berger Bison Lite, Nippon Superio.) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour complete for the work.
Providing and applying Premium plastic emulsion paint with roller application minimum three coats applied @ 0.75 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -1 Class D & C ( Glossy and Semi Glossy Finish) of required shade (Product such as Asian Apcolite Premium , Dulux Super Cover, Berger Easy Clean Nippon Breezee Metex Gold, Opus I-50 / Calista) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(with 3 year Warranty)
Providing and applying Providing and applying on exterior surface with PREMIUM Exterior emulsion paint of required shade to give protective and water proof finish minimum 3 coats applied @ 1.40 lit / 10Sqm up to final finish as per relevant I.S. Code 15489:2013 Type -2 Class D , C (Glossy /Semi Glossy finish ) (Product such as Asian Apex Weather Shield Prima E900, Berger Weathercoat Antidust, Nerolac Everlas Excel, Nippon Sumo Etra, Opus True flex) inclusive of providing abro tape on edges and articleand cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work.(With 3Year Warranty.)
Providing and applying priming coat on wood work applied @ 0.50 li/Sqm as per relevant IS code 3536:1999 ( product such Asian trucare, Burger Wood Keeper, Dulux Duwel wood primer) with all tool tackles and labour etc for complete the work
Providing and applying mimimum 2 Coats Glossy finish Enamel paint in al surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian Apcolite Premium Enamel Dulux Promise Premium Enamel Nerolac Synthatic Enamel, Opus Prime enamel ) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Providing and applying FRENCH SPRIT POLISH on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if visible, applying a coat of wood filler, cleaning the surface, applying various (minimum 4 coats) of French spirit polish @0.35 lit/Sqm till the surface gives high gloss. inclusive of providing abro tape on edges and article and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work..
Providing and fixing flush door shutters, conforming to IS : 2202 (Part-I), decorative type core of block board construction with frame of first class hard wood and well matched teak ply veneering with vertical grains or cross bands and face veneers on both faces of shutters excluding hinges. 25 mm. thick (double leaf for cupboard shutters with piano type hinges
Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with necessary screws etc. complete. Triple strip vertical type.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required : Size 600x450x200mm
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete.75 mm dia pipe.
110 mm dia pipe
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall thickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Tee/ Tee with door/ Bend 45°/ Bend 90° 75 mm
Nahani trap 110x75mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK including cutting chases and making good the walls etc., 20 mm nominal outer dia .Pipes.
25 mm nominal outer dia .Pipes.
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: Long nose bib cock (500 grams)
Providing and fixing M.S. grill of approved pattern made of M.S. flats orsquare or round bars welded to steel frame of windows etc. includingapplying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-250 MAIN GATE
Providing and fixing at all height false ceiling consisting of frame work "W" / "U" / "L" sections made of G.I. sheet with zinc coating of grade 120 consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm Each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the gypsum board with ceiling section and periMeter channels 0.55mm thick 27mm high having flanges of 20mm and 30mm long, the periMeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of periMeter channels suitably fixed including providing and fixing 12.5 mm thick tapered edge gypsum board conforming to IS: 2095- Part-I all complete as per drawing and specification and direction of the Engineer in Charge but excluding the cost of painting.
Providing and fixing of aluminium tile false ceiling comprising of Tile of size 600 x 600mm x 0.7mm. The Tile ends will be raised with pips and stops to ensure positive engagement into the spring to enable for demounting of individual panels. The Tile sides will be sufficiently high to ensure a minimum deflection across the length of Tile. All Tiles will be bevel edged. The Tile shall be powder coated. The Tile shall be clipped into clip-in profile made of 0.5mm thick G.I sheet. The clip-in profile shall be supported from slab by means hold on clamp with clip and 4mm dia G.I. rod fixed to ceiling rigidly. Wall trim box of size 15x30x15mm made from 0.4mm thick luminium alloy sheet to be provided all along the wall to hold panels (only surface area of false ceiling is to be measured and Each deductions for lights, diffusers, columns etc shall be made) With perforated tiles having perforation with 2.5mm dia and 5mm center to center and pasted with Eachn woven tissue on the back side
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 150mm diameter and weighing not less than 440 grams.
Providing and fixing in expansion joint pre moulded cross linked polymer based filler as per IS:1838 (part III) of approved make including cutting to required size and shape etc complete.50 mm thick
Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatment
Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete.For gap 50 mm wide
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Providing and making 18 mm thick plain cement mortar band in cement mortar 1:4 (1 cement : 4 fine sand) per cm width:
Sunk Bands
Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. Electric resistance or induction butt welded tubes Grade-300
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
Providing Water proofing treatment over Roof, Wall, Chhajjas, Balcony with Diamond Shield and Sealer coat or equivalent at leakage/ seepage area consisting of the operation: (i) Surface preparation roughening of surface, opening of cracks in ‘V’ groove in size of 5mm x 10m (WxD), filling of cracks with putty of Diamond shield with laying fiber glass mesh, Cleaning of surface by scrubbing with steel wire/ Nylon brush. Removing all dust particles and washing with adequate water to clean completely. (ii) Providing and applying 1st coat of diamond shield or equivalent compound (having two component dry powder 80% Chemical 20% (chemical having 30% solid contents) making flexible waterproof and protective modified mortar with minimum thickness 70-80 micron after proper mixing of both the parts of compound along with laying of fiber glass mesh (of weaving size of 10x10 yarn/inch duly coated with alkaline resistant polymer). Allow the coating to set in natural air for minimum 2 Hrs. After 1st coat apply 2nd coat with minimum thickness 100 micron of the same compound. Allow the 2nd coat to set in natural air for minimum 4 Hrs. Total consumption of the diamond shield or equivalent in both coat should be @ 17.90 kg for 10sqm area.
Finishing walls with water proofing cement paint to give an even shade. On new work (Two or more coats )
White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing vitreous china water closet (European type W.C. pan) with white ISI marked plastic seat and lid, 10 litre low level white P.V.C. flushing cistern (same colour), conforming to IS : 7231, with al lfittings and fixtures complete including cutting and making good the walls and floors wherever required : White pedestal type
Providing and fixing 15 mm nominal bore C.P copper connection pipe with C.P brass nuts collar and PVC bush of approved quality:
Providing and fixing white vitreous china urinal basin with waste fitting as per IS : 2556, and other couplings in C.P. brass completeFlat back half stall urinal of size 460x380x250mm
Flat back type urinal of size 460x380x250mm
Providing and fixing one piece construction white vitreous china squatting plate urinal with an integral rim longitudinal flushing pipe, standard size G.I. flush pipe for back and front flush, C.P. brass coupling complete including cutting and making good the walls and floors etc. wherever required : GROUND FLOOR
White Size 550x450 mm
White Surgeon type size 660x460 mm
Providing and fixing vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings White
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of brackets, cutting and making good the wall wherever required Size 600x450x200mm
Providing and fixing 600x450 mm beveled edge 4mm mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and ackets, cutting and making good the walls wherever required : 1000x510 mm bowl size 460x410x175 mm
Providing and fixing stainless steel A ISI 304(18/8) kitchen sink with drain board as per IS 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets,cutting and making good the walls wherever required: 560x410 mm bowl depth 215 mm.
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 (4kg/sqcm) including required couplers, jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 75 mm dia pipe.
110 mm dia pipe.
150 mm dia pipe.
Vent covel 75mm
Nahani trap 110x75mm
Plain reducing Tee 110x75mm
Access door cap 110 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in .CONCEALED WORK including cutting chases and making good the walls etc., 20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete 20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete: 20 mm dia nominal bore
25 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and laying in trenches G.I. pipes medium class complete withG.I. fittings including excavation of trenches, refilling the same and testing of joints complete: 20 mm dia nominal bore
25 mm dia nominal bore
32 mm dia nominal bore
40 mm dia nominal bore
50 mm dia nominal bore
65 mm dia nominal bore
80 mm dia nominal bore
Making connection of G.I. distribution branch in G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipeetc. complete: (dia of main line to be measured) 32 mm nominal bore
50 mm nominal bore
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: SWAN COCK
Bib Cock
Long body bib cock (500 grams)
Piller Cock (400 grams)
Two way bib cock (800 grams)
Stop cock (concealed) (600 grams)
Angle valve for basin mixer and geyser points (450 grams)
Bottle trap set with extension pipes
Toilet paper holder
Soap dish plate
Towel rail (600mm long x 20mm dia)
Shower Rose(revolving type)(150mm)
Health foscet (hand jet) with flexible connection pipe (for WC)
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25mm nominal bore
32mm nominal bore
40mm nominal bore
50mm nominal bore
65mm nominal bore
80mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal bore
25mm nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality: 25 mm diameter pipe
50 mm diameter pipe
65 mm diameter pipe
80 mm diameter pipe
50 mm diameter pipe
65 mm diameter pipe
80 mm diameter pipe
100 mm diameter pipe
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply including all CPVC plain &brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer in Charge.INTERNAL WORK - EXPOSED ON WALL 40 mm nominal outer dia .Pipes.
Providing and laying non-pressure NP2 class (light duty)R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand) including testing of joints etc. complete : 150MM NP
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm eachminal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 150 mm diameter S.W. Pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete withC.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type.
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength eacht less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm eachminal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm eachminal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm eachminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including RCC cover with frame 450x600 mm internal dimensions.
Extra for depth for manholes
Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength eacht less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be eacht less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm eachminal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm eachminal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets :
Providing and constructing brick work for extra depth beyond 45 cm ofbrick masonry chamber with well burnt modular clay bricks crushingstrength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4coarse sand) with inside plastering 12 mm thick with cement mortar 1:3 (1cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls: For 500x700 mm size
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Constructing masonry Chamber 30x30x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 60x60x75 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Constructing masonry Chamber 90x90x100 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Cutting holes more than 20x20 cm and upto 30x30 cm in walls including making good the same :
Constructing masonry Chamber 60x45x50 cm, inside with modular well burnt clay bricks of 35 kg/ cm² in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand :10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). Stone boulders of size range 5 cm to 20 cm, in recharge pit
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge upto 90 metre depth below ground level. All types of soil 200 mm dia.
Rocky strata including Boulders. 200 mm dia.
Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm dia.
150 mm dia
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. 50mm dia.
65mm dia.
80mm dia.
100mm dia.
150mm dia.
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 50mm dia.
65mm dia.
80mm dia.
100mm dia.
150mm dia.
Providing and wrapping 4 mm thick of approved make and quality bitumen based anti rust felt over MS pipe with overlap of 25 mm to make an impermeable layer including painting with one coat of bitumastic paint before felt complete. (Only on MS pipe to be laid in soil below ground 80mm dia.
100mm dia.
150mm dia.
Providing and fixing 15 mm dia, Quartzoid bulb type G.M. Sprinkler Head set to operate at 680C of approved make chrome plated complete in all respect as required.
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required. 80 mm dia.
100 mm dia.
150 mm dia.
Providing and fixing Flow switches suitable for fixing in 50mm to 150mm dia pipe line, complete with all accessories to provide indication in annunciator panel.
Supplying and fixing single headed internal hydrant valve with instantaneous Stainless Steel couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS: 5290 (Type - A) with blank Gunmetal cap and chain as required.
Supplying & fixing 63 mm dia Stainless Steel IS: 3444 Grade-1 branch pipe with 20 mm dia (nominal internal) Stainless Steel nozzle conforming to IS: 903, suitable for instantaneous coupling connection to connect hose pipe coupling as required.
Supplying and fixing 63 mm dia, 15 mtr long Flax canvas hose pipe with 63 mm dia Male and Female Stainless Steel-IS: 3444 Grade-1 couplings duly binded with GI wire, rivets etc. conforming to IS: 636 (Type -A) as required.
Supplying, fixing, testing and commissioning of flanged butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts,Bolts, washers, gaskets, conforming to IS: 13095 of following sizes as required. 150 mm nominal bore
100mm dia.
80mm dia.
Providing and fixing M.S. structural work fabricated from standard sections, (MS rounds, angles, channels etc.) including cutting to size,drilling welding including cost of steel fasteners, clamp in RCC structural members as directed, including two coat of enamel painting over one coat of red oxide primer complete.
Supplying and installing Air Vessel of 300 mm dia, 1.5m in height made of 5mm thick MS sheet including painting with one primer and two finish coats complete as per specification.
Providing and fixing standard fireman's axe (tested for 20000 Volts) with heavy insulated rubber handle. (ISI marked)
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. 25 MM
Providing and fixing brass GM/ ball valve (full bore type) with plastic coated lever and screwed female ends tested to 20 Kg/ cm2 of approved quality as specified. - 50 mm dia
Providing and fixing gunmetal single acting air release valve with screwed inlet 25 mm dia and with necessary G.I. coupling, valve to be fitted on top of Air vessel or on wet riser as per specification.
Providing and fixing pressure switch with suitable for 1-10 Kg/cm2 including 12/15 mm Ø isolation valve, G.I. nipple, elbow, electrical connections setting of Cut-In and cut-Off pressure complete in all respects and in an approved manner.
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner
Supplying and fixing swinging type First-Aid Hose Reel drum with MS construction spray painted in Post office Red colour, conforming to IS: 884 with upto date amendments, complete with brackets for fixing on wall, connections from riser with 25 mm dia MS/GI pipe and GM gate valve but excluding hose reel.
Supplying and fixing 4 way Fire Brigade Connection of cast iron body with 4 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain conforming to IS: 904 including connection to existing MS pipe line complete as required.
Supplying and fixing 2 way Fire Brigade Connection of cast iron body with 2 eachs. Gun metal male instantaneous inlet couplings complete with cap and chain conforming to IS: 904 including connection to existing MS pipe line complete as required
Supplying and fixing of MS hose cabinet box of made of 2 mm thick MS sheet and 40 x 40 x 5mm angle iron with front openable cover having 6 mm thick glazed glass viewing window i/c necessary locking arrangement, on existing wall/ brick platform etc complete as required. Size 1800 mm x 900 mm x 500 mm
Size 900 mm x 600 mm x 500 mm
Supply and fixing 150 mm dia CI steiner in suction line from water tank complete.
Supply and fixing 100 mm dia CI steiner in suction line from water tank complete.
Supply and Installation, testing and commissioning of Sprinkler unbraided flexible Pipe required length of 1.5M including angles and supports
Supply and Installation, testing and commissioning of Sprinkler unbraided flexible Pipe required length of 0.75M including angles and supports
Supply and Installation, testing and commissioning of Sprinkler unbraided flexible Pipe required length of 1.0M including angles and supports
Supplying and erecting orifice plate having 6 mm thickness, 140 mm outer dia at every single outlet hydrant valve as per specification
Supplying and fixing 19mm dia High pressure rubber hose for swinging type First-Aid Hose Reel drum
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. All types of soil 150 mm dia
Rocky strata including Boulders. 150 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 150 mm nominal dia
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 150 mm dia
Providing and placing in position India Mark II hand pump with 32 mm diameter riser pipe assembly complete with all accessories (riser pipe and plunger rod to be paid separately).
Providing and fixing filter of minimum 100 litre capacity for roof top rain water harvesting through tube well consisting of two layered HDPE tank with five layers (each layers of minimum 100 mm) consist of coarse sand, 4mm, 6mm, 8mm & 12 mm gravels with stainless steel wire mesh fixed between each layer with suitable length and sufficient numbers of 110 mm dia PVC pipe pieces in the bottom of tank to support the above layer including fixing of inlet and out let P.V.C. pipe of required diameter as directed by Engineer in charge
Providing ISI Mark 32 mm dia G.I. ( B class) riser pipe in 3 meter length socketed on one end as per IS: 1239 ( Part I) 1990 with up to date amendments and socket as per IS: 2062/1990 up to date amendments.
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all leads & lifts as per relevant clauses of section 300.
Compacting Original Ground Construction of Embankment/sub-grade with Material Deposited from Roadway Cutting Construction of embankment/sub-grade with approved materials having required C.B.R. for embankment/sub-grade (unless specified otherwise in the contract) deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2.
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401. watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause 401 Plant mix method (with Mechanically crushed stone only) Plant mix method (with Mechanically crushed stone only) For Sub-base cum drainage layer or upper sub-base with Grading- III Material
Dry Lean Cement Concrete Sub-base as per IRC:SP-49 (Construction of dry lean cement concrete Sub-base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 26.5 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing as per clause 601.)
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement as per IRC:58 over a prepared sub-base, coarse and fine aggregate conforming to IS:383 and graded as per table 600-3 mixed in a batching and mixing plant as per approved mix design, transported to site, laid with slip form / fixed form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per clause 602.Using Slip Form Paver With Cement concrete grade M-30 and minimum cement content @ 375 kg/cum.
Construction of RCC open drain 0.60m x 0.60m inside dimension lined with 120 mm thick RCC M-20 walls, 120 mm thick CC M-20 foundation, over 100 mm thick (Av) leveling course in PCC M-15 including excavation , dressing of sides and bottom, provision of HYSD reinforcement consisting 8 mm dia horizontal bars @ 150 mm c/c and L- shaped 8 mm dia vertical bars @ 150 mm c/c (L= 800 mm) including cutting , bending and binding wire, placing in position , providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical
Construction of RCC drain/chamber cover, placing in position,providing shuttering and concreting by using concrete mixer,compaction by ibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
Internal Wiring - Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1) Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.1) Short Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1) Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.12.3) Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, wire in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.13.1) 3 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
9 X 2.5 sq. mm in 32mm conduit
3 X 4 sq. mm in 25mm conduit
3 X 10 sq. mm in 25mm conduit
6 X 6 sq. mm in 32mm conduit
6 X 10 sq. mm in 40mm conduit
6 X 16 sq. mm in 50mm conduit
4 X 25 sq. mm + 2 X 16 sq. mm in 50mm conduit
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in concealed complete as per specification and IS: 9537 (2000 Part 5) 1.15.2) 25 mm
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.2) 25 mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi strand wire in the existing surface/ concealed, FRLS PVC conduit / PVC casing caping as per specification and IS: 694 (2010) 3.11.2) 2 x 1.5 sq. mm
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification and IS: 694 (2010)
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.9) Fan regulator (two module size) electronic stepped type moving all rounds
Telephone socket outlet
25/32 amp A.C. Starter switch
Batten/ angle holder
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as per specification. 5.7.2) Deluxe
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.
Supplying, installation, testing and commissioning of following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, earthing etc. complete as required. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments. 6.1.3) 1200 mm sweep
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.2) 400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.1) 300 mm sweep
450 mm sweep
Supplying and fixing following sizes of down rod of 15/20mm dia M.S. pipe of thickness 2 mm to ceiling fan including painting with matching colour etc. as per specification. 6.11.4) 120 cm long
Providing and fixing phenolic laminated sheet cover of 180 mm dia 3 mm thick on the fan box etc. as per specification. (If provided at the time of installation of ceiling fan)
Supplying and fixing of wall/ cabin fan {Inverter Type: with builtin battery backup} including connection etc. as per specification. P.F. should be greater than 0.9 6.10.1) 400 mm sweep
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.1) 3 Watt
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.16.2) 36 watt, size 600 x 600mm
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.6) 15 Watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.3) 18/20 watt {4 feet}
Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 6.20.1) 9 Watt
Supplying, installation, testing and commissioning of following LED Signage entry/exit having minimum size 300mm (L) x 200mm (H) x 45mm (W), fitting complete including built in battery backup for 2 hour with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP-20 6.26.2) Double sided LED Signage
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.11) 150 watt
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated aluminium conductor wire lead of length upto 50cm including providing aluminium thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 7.15.2) 25 sqmm (63 amp)
Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.16.5) 75x6mm (500 amps)
2 Nos 100x10mm (1600 amps)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification. 7.19.2) Above 300 mm and upto 450 mm deep
1200 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification. 7.20.2) 200 amp (30x5mm)
300 amp (50x5mm)
400 amp (50x6mm)
500 amp (75x6mm)
600 amp (80x6mm)
Supplying, installing, testing and commissioning of TPN tap off box of following capacity, made of 2 mm thick sheet steel enclosure duly painted with powder coating, on existing rising mains with space for TP Disconnector switch/ MCCB (without switch/MCCB), interconnections with copper lead and copper lugs/thimbles, earthing etc. as per specification: 8.2.4) 400 amps
Supplying, installation, including suspension, testing and commissioning of following capacity bus trunking with aluminium busbars having current density of 130 of A/ sq cm at nominal current rating in 2 mm thick sheet steel enclosure IP 42 rating (as per IS: 2147, and IS: 8623) in convenient sections for use on, 3 phase, 4 wire, 415 volts, 50 Hz, A.C. supply including jointing of sections, flexible joints, expansion joints, bends and earthing with 2 runs of galvanised iron strips, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as per specification. 8.3.1) 800 amps
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity COMPACT SANDWICH TYPE BUS TRUNKING for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating (as per IS: 2147, and IS: 8623) after fixing the tap off boxes and all accessories, made of 2 mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium busbars having current density of 130 of A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners, connecting to earthing system etc. as per specification: 8.9.7) 1600 amps 50KA SC for 1 sec
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as per specification, IS/ IEC: 60947-2 and Ics = 100 % Icu. 9.1.5) 3 pole MCCB, 125A, Adjustable Thermal - Magnetic Release, 25KA
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 35KA
3 pole MCCB, 320A, Adjustable Thermal - Magnetic Release, 35KA
4Pole MCCB 100A Adjustable Thermal Release, 35KA
4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA
4 pole MCCB, 630A, Adjustable Thermal - Magnetic Release, 50KA
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.4) 4 way Double door
6 way Double door
Supplying and fixing on surface/ recess vertical type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, with 200 amps tinned copper busbar, common neutral link, earth bar, din bar, detachable gland/ knock out plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 9.5.4) 4 way (4 + 12), Double door
12 way (4 + 36), Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1) 6 amps to 32 amps
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.1) 6 amps to 32 amps
Supplying and fixing DP MCB, 240 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.13.2) 6 amps to 32 amps
Supplying and fixing TP MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.14.5) 63 amps
Supplying and fixing following rating, 240 volts TWO POLE ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.19.3) 63 amps
Supplying and fixing TPN MCB, 440 volts, 'C' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.5) 63 amps
Supplying and fixing TP&N MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.17.2) 6 amps to 32 amps
Supplying and fixing following rating, 415 volts, FOUR POLES, ISOLATOR in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.20.3) 100 amps
Supplying and fixing 2 pole and earth, 240 volts, industrial type, socket outlet, enclosed metal plug top along with SP MCB in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as per specification. 9.24.2) 32 Amp with “C” curve MCB
Providing and fixing approved make, Electrically Operated, draw out type, 415/500 volts, 4 pole air circuit breaker complete with all standard accessories as per manufacturers specifications including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification and Ics = Icu = Icw for 1 second, IS/IEC: 60898. 10.2.1) 800 amps, 4 pole, 50 KA
Providing and fixing metal clad, TP&N 4 pole automatic change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification. 10.9.5) 630 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.5) 400/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.20.2) Digital type
For ammeter
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.1) Digital type
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 11.2.3) 5 KVA with DC bus voltage 180 V
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification. 11.4.6) 200 AH
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Supplying and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as per specification.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1) With 3 metre long GI Pipes and 50 kg back filling compound.
Supplying and laying HDPE pipe of 4kg/cum in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.2.1) 63 mm outer dia
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.4.1) 100 mm dia
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.1.14) 3.5 x 70 sq. mm.
3.5 x 300 sq. mm.
Supplying and laying following sizes additional one number, FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground as in the same trench in one tier horizontal formation at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1). 15.2.17) 3.5 x 150 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.3.11) 3.5 x 25 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.5.13) 4 x 10 sq. mm.
4 x 16 sq. mm.
4 x 25 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 25x3 mm M.S flat clamp and steel dash fastener/ G.I. bolts and nuts as per specification , IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.6.1) 3.5 x 50 sq. mm.
3.5 x 70 sq. mm.
3.5 x 95 sq. mm.
3.5 x 120 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade on surface/ existing cable tray with 1 mm thick GI saddle as per specification, IS: 1554 (1988, Part 1) & IS: 7098 (1988, Part 1) 15.7.2) 3.5 x 185 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. 15.23.14) 3½ X 50 sq. mm (32 mm)
3½ X 70 sq. mm (35 mm)
3½ X 95 sq. mm (38 mm)
3½ X 120 sq. mm (45 mm)
3½ X 185 sq. mm (50 mm)
3½ X 300 sq. mm (63 mm)
3½ X 400 sq. mm (70 mm)
4 X 16 sq. mm (22 mm)
4 X 25 sq. mm (25 mm)
4 X 35 sq. mm (28 mm)
Supplying and making outdoor end termination with cast resin compound including aluminum lugs and other jointing materials for following size of FRLS PVC insulated and PVC sheathed / XLPE aluminum conductor power cable of 1.1 KV grade as per specification. 15.25.6) 3½ X 150 sq. mm
3½ X 300 sq. mm
Supplying, fixing and cramping suitable size and all type aluminium ferule/ lugs to following size 1.1 KV grade power cable core / lead, pressed with high pressure cramping tool including connection to switch gear/ MCCB etc as per specification. 15.28.2) 10 sq. mm
Supplying and laying one number following sizes XLPE, steel armoured, aluminium conductor power cable of 33 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per specification. 17.1.9) 3 x 400 sq mm
Supplying and installing following size powder coated, perforated M.S. cable trays with perforation not more than 17.5% rigidly suspended from the ceiling with M.S. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification. 18.1.2) 150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width x 50 mm depth X 2.0 mm thickness
600 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying and fixing of following sizes powder coated, perforated, M.S. cable trays bends (horizontal) turning at 900 in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 18.2.4) 300 mm width X 50 mm depth X 1.6 mm thick
450 mm width X 50 mm depth X 1.6 mm thick
600 mm width X 62.5 mm depth X 2 mm thick
Supplying and fixing of following sizes vertical, powder coated, perforated, M.S. cable trays bends (vertical) turning at 900 in another plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 18.3.4) 300 mm widthX50 mm depthX1.6 mm thick
450 mm widthX50 mm depthX1.6 mm thick
600 mm widthX62.5 mm depthX2 mm thick
Supply of "H" beam steel pole as per IS specifications in standard length for over head line work: 19.1.2) "H" beam steel pole 152x152x7x12 mm standard weight 37.1 kg /metre
Supply of GI PIPE POLE made of "B" class GI pipe making necessary hole for cable entry and providing earthing stud (welded at specified height) including painting with one coat of red oxide zinc chromate primer. 19.4.1) 50 mm dia
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.8.3) 11 metre high, dia 210mm at bottom and 90mm at top, base plate size 300x300x20mm, foundation bolts 750mm long
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification. 19.9.6) Double Over Hang 1.00 metre Long
Erection of steel tubular or "H beam POLE STRUT in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling and securing with holding clamps, bolts and nuts etc. as per specification:
Supplying erection testing and commissioning of hot dipped galvanised (single dip 86 micron) 20 metre High mast pole on existing RCC foundation with all accessories and equipments, detailed as below to withstand wind pressure upto 180km/hr and minimum following specifications: a) HM shaft made of not more than 2 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on bottom and 150 mm on top, base plate 30mm thick 670mm dia, PCD of foundation bolts 650mm. b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. k) Anchor plate of size 750x750x6mm, tem-plates 3mm thick, GI foundation bolts 12 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
Designing and providing suitable and approved size RCC foundation for 12-30 mere high mast including seel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification
Supply and fixing following overhead line accessories. 20.1.3) Stay wire 7/3.15mm dia
DC cross arm made of MS channel 100x50x5 mm @ 9.56 kg/m
Supplying and erection of stay set complete (galvanized) with 19/20mm dia x 1.8 metre long stay rod, anchor plate of size 300mm x 300mm x 6.4 mm, thimble stay clamps, turn buckle (19/20mm x 600mm), strain insulator and specified G.I. stay wire etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as per specification. 20.2.2) With 7/3.15 mm dia G.I. stay wire
Supplying and erection of angle/channel iron cross arms/ bracket/ other fitting of approved size and shape including drilling of holes for insulator pins, bolts and nuts etc as per specification.
Supplying and fixing approved make 11 KV glazed porcelain pin insulator with G.I. spindle on existing pole bracket with necessary materials as per specification:
Supplying and fixing approved make 11 KV glazed porcelain disc type insulator with tension hardware on existing pole/ support/ cross arm channel as per specification complete:
Supplying and erection of 11 KV gang operated air break switch on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of 11 KV D.O. fuse unit on existing two pole structure with insulators and all other accessories complete including locking arangement as per specification.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as per specification.
Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as per specification.
Supply and erection standard ACSR (aluminium conductor steel reinforced) confirming to IS 398-1961 of approved make at existing insulator at height upto 14m from ground level including stringing, binding with insulator, jointing wherever required, jumpering, tearing off connection etc complete etc. as per specification including clearing off obstacle if any: 2.32.5) Dog 6/4.72(AL), 7/1.57(S) mm dia with calculated aluminium area 105 sq.mm , weight 394 kg/ km (248 amps)
Supplying and erection DANGER BOARD made MS sheet duly painted and maked as per IE rules and specification.
Supply and errection of following Polymer Insulator with G.I. Bolt, Nuts and Straps etc. as per specification. 20.34.3) 11 KV Disc Insulator
Supplying and installation of outdoor type Transformer ONAN type with copper winding having following continuous KVA rating, 11 /0.415 KV, 3 Phase 50 Hz Vector group DYn-11, (Online tap changer) tapings in steps of ± 2.5%, ± 5%, --7.5% with oil conservator, silica gel breather having connecting terminals on HV side suitable for bare conductor/HT cable connection, cable end box on medium voltage side suitable for 1.1 KV single core UG cable(upto 300 sq mm)/bus ducting arrangment and confirming to IS:1180 Part-2 Level 3, on existing double pole structure or Brick /CC/RCC platform with all fittings, accessories, filled with filtered transformer oil including testing and commissioning etc. complete as per specification 21.1.3) 200 KVA
Supplying and spreading hard stone aggregate 25mm size in out door switch yards as per direction of Engineer-in-charge.
Providing and erecting floor mounted sand/ water bucket stand for keeping 4 nos. of fire bucket, 1500 mm in length and 900 mm in height made out of 30 X 30 X 4 mm angle iron welded with 4 hooks and duly painted with one coat of zinc cromate primer and 2 coat of synthetic enamel paint of post box red colour etc complete.
Supply and laying SMC chequere plate in size 1m x 1m x 2.5mm (thick) to withstand 22 KV Electrical stress near LT or 11 KV HT panel etc complete.
Supplying and erecting chain link mesh fencing for electric sub-station switch yard of 2.5 m approx. height from ground level using angle iron size 50 X 50 X 6 mm erected in C.C. foundation 15 X 15 X 40 cm deep at every 2 metre fitted with flat iron support of size 25 X 6 mm on top, bottom and mid way and chain link mesh 50 x 50 mm aparture and 4 mm dia G.I. hard wire securing and screwing with 2mm dia G.I. wire, G.I. staples, G.I.U-nails or steel pins to the angle iron at every distance of 30 cms, by iron studs complete duly painted with one coats of red oxide and two coats of approved colour paint. (Area of fencing i.e. height x length is to be measured)
Lift and Submersible pump set - Add or deduct for providing all additional parts/ equipments or for enhancing the capacity of parts/ equipments in automatic lift for 8 persons, speed 1.5 m/sec for every additional floor beyond initial G+3 floors.
Add or deduct for providing all additional parts/ equipments or for enhancing the capacity of parts/ equipments in MACHINE ROOM LESS TYPE automatic lift for 16 persons, speed 1.5 m/sec for every additional floor beyond initial G+3 floors.
Supplying, installation, testing and commissioning of centrifugal type mono-block electric pump set for water supply system having following capacity three phase, 415 volts AC induction motor and pump including suitable channel iron base frame, suitable C.C. foundation and connection of suction and delivery line etc. as per specification. 23.2.1) 3 HP, 420 LPM, 20 m head, suction size 65 mm, delivery size 50 mm
Supplying, installation, testing and commissioning of submersible pump set for water supply system with submersible motor directly coupled to multi-stage submersible pump of specified discharge capacity, head, delivery size in existing bore well including 2 sets of suitable size holding clamps made out of 50 mm X 6 mm MS flat, connection with suitable submersible cable of standard length etc. as per specification. 23.3.7) 7.5 HP, three phase
Supplying and fixing M.S. clamp 50 cm long made of 50mmx5mm thick M.S. Flat for holding the pipes and submerable pump set as per specification.
Supplying and fixing 300 mm dia 2 mm thick M.S. sheet cover with 3 cm edge in two past on tube well bore pipe as per specification
Supplying, laying and fixing following size submersible cable along with GI/PVC/HDFC pipe line or laid in ground etc as per specification 23.14.4) 3x6.0 sqmm
Supplying and laying of approved make stainless steel wire rope of 6 mm dia for support of submersible pump set complete with tying to pump set and pump holding clamp.
Air Conditioner - Supplying of approved make split type Air Conditioner unit with cooling unit (copper coil) and condensing unit (copper coil) including 5 years compressor warranty and standard length of upto 3 metre of copper piping with insulation, etc complete as per specification: 24.3.2) 1.5 ton split type capacity 4500 kcal / hr (3 star).
2.0 ton split type capacity 6000 kcal / hr (3 star).
Supply and fixing of approved make wall mounting type voltage stabilizer with input volts 160-250, output volts 200-240 volts and double step relay on desired location with necessary fixing material including connection etc complete as per specification. 24.7.2) 5 KVA
Supply, connecting and fixing extra length of copper piping for split type air conditioners of following dia and approved quality with insulation sleave etc complete as per specification 24.10.1) 5/8 "
Supplying and fixing good quality powder coated MS frame for installation of out door unit of split type Air Conditioner at desired location with atleast 6 nos steel fastners etc complete as per specification
Supplying, connecting and fixing 15mm dia PVC flexible drain pipe (reinforced with nylon threads) in drain outlet of split type air conditioners etc complete as per specification
Fire Alarm System - 10 Loop Fire alarm Control panel ( Modular) each loop 252 points Each loop having capacity to handle 252 addressable points (detector & devices) in any flexible combination, with battery backup 24hours and 30minutes, 6", backlit LCD display, Touch screen for maintenance operations and function keys,Multi-language display,5000-event, history-logging capability with on-line and off-line reports ,Multiple levels of password protection,Time-based-controlled output functions,Holiday schedule,UL 864 9th Edition Listed & ULC Listed FM Approved.
Intelligent Addressable Type Manual Call Point: Intelligent Manual Fire Alarm Box is constructed of durable, molded and polycarbonate material that is matte finished in red with raised white lettering Single-action,Pull-down lever is down, until manually reset,Polarity insensitive via SureWireTM technology
Response Indicator for above false ceiling detector
Intelligent Addressable Relay control module for Hooter Interfacing and supervising normally open (N.O) or normally closed (N.C) contacts,Integral single-pole, double-throw (SPDT) relay (up to 4 amps) ,Multi-color light-emitting diode (LED) indicates system status, UL Listed & ULC Listed; FM Approved
2 core x 1.5 sq.mm Armoured FRLS cable
Supply and erecting following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. 26.17.3) ABC Fire Extinguisher 4KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 2A, 89B. With all accessories.
CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve
CC TV Camera - Supplying, Installation, Testing & Commissioning of Analogue Type Dome AHD 2 MP Camera of 1080p Real Time High resolution CMOS Progressive scan true day/night capability minimum illumination: 0 lux (IR ON) TDN (IR-cut) AWB, AGC, Defog, 3.6mm & 2.8-12mm lens, IR distance: upto 40 meters power: 12 VDC, Vandal resistant, Dual output AHD & CVBS as per specification.
Supplying, Installation, Testing & Commissioning of Analogue Type Bullet Camera AHD 2 MP Camera VF of 1080p Real Time High resolution CMOS Progressive scan true day/night capability minimum illumination: 0 lux (IR ON) TDN (IR-cut) AWB, AGC, Defog, 3.6mm & 2.8-12mm lens, IR distance: upto 40 meters power: 12 VDC, Vandal resistant, Dual output AHD & CVBS as per specification.
Supplying, Installation, Testing & Commissioning of 32 Channel NVR 2 Sata port - Up to 32 channel IP camera input , Max 200Mbps incoming bandwidth ,Smart H.265+/H.265/Smart H.264+/H.264 dual codec decoding , Up to 8MP resolution preview and playback , Support 2 SATA HDDs up to 6 TB each, 2 USB(1 USB3.0, 1 USB2.0) , 1 HDMI / 1 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 4/2 , Two way talk 1 Channel Input, 1 Channel Output RCA , 1 RJ-45 port (10/100/1000Mbps),
Supplying, Installation, Testing & Commissioning of 24 Port PoE Switch - 10/100 24 Port with 2Giga & 2 SFP Combo Uplink Ports, Power Budget 250W as per the specification.
Supplying, installation, testing and commissioing of 8 TB Surveillance Hard Disc Drive complete as required.
Supplying, Installation, Testing & Commissioning of 6U Indoor Rack - Wallmount 6U 450D With Front Glass Door Lock & Key 550 6U - loaded with cable manager + PDU + Fan Complete as per required.
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 27.49.4) 55 inch
Supplying , installation , Testing and Commissioning of Compact Full Range 4" Ceiling Speaker with 40 W RMS power @ 8 Ohms ,70 V/100V: 30 W / 15 W / 7.5 W with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Dual Channel Audio Amplifier Professional 1700-Watt (Per Channel 700 to 800 Watts into 4 Ohms OR Per channel 400 to 500 Watts into 8 Ohms OR 1600 to 2000 Watts into 8 Ohms (bridge mode)Stereo with all necessery terminals and Connectors.
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.
Plastering 15 mm thick on brick work/ CC surface with cement mortar 1:4 (1 cement : 4 fine sand) at all levels.
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.
Applying priming coat on steel work with red oxide zinc chromate primer.
Painting wood steel and other metallic surface with Aluminium Paint complete with material and labour including preparation of surface.
Medical Gas Pipe Line System - Integrated Combined Area Alarm and area valves should be in a single unit. Please check technical specifications for complete details. 6.01) 1 Gases (O2) and 1 Vac
Terminal units Wall/BHU/Pendant mounted - Meets the requirements of ISO 9170-1/ HTM 02-01/ NFPA 99 . Please check technical specifications for complete details. .
Terminal Unit O2 8.05) Terminal Unit Vac
Copper Piping As per EN13348 standards. (Note: Above mentioned quantity for copper is approximate, and it will be calculated based on final installation measurement sheet approved authorized person.) 11.01) 12mm
Ward Items –Imported 12.01) Flow meter with humidifier
Ward vacuum unit with 600ml jar
Probes
Bed Head Panels (Wall / Ceiling mounted) :- 1500 mm Bed Head Panels double ducts system as per technical specifications. 13.01) SITC of Bed Head Panels . Please check technical specifications for complete details.
UOM Name
Percentage
Per mile
Per Diem Rate
MAN DAYS
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.11 MB
3662590503382863201_153213_1258250143523725404_129113_Guidelines_to_Bidders_EPS_v1.pdf
NIT • 0.13 MB
7135483057294553126_198168_FORM A.doc
NIT • 0.15 MB
1650860132301311108_198168_NIT.doc
NIT • 0.32 MB
9174394495695004155_198168_PQ.doc
NIT • 0.29 MB
2913080914656282201_198168_ANNEXURE E.doc
NIT • 0.04 MB
1436795265476781891_198168_198168 Notice.docx
NIT • 0.07 MB
8228825958490660081_198168_BOQ.xlsx
BOQ • 0.25 MB
4797473648224394888_198168_Approved material List.xlsx
BOQ • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].