Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | ₹19.3 L | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹19.9 LRejected-Finance SUMATEE BHAWAN GUWAHATI AIRPORT NEAR BORJHAR TELEPHONE EXCHANGE GUWAHATI 781015 ASSAM | KAMRUP METRO | ASSAM | 781015 | ₹19.9 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹23.6 LRejected-Finance | ₹23.6 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹24.5 LRejected-Finance AZARA GUWAHATI ASSAM 781017 | KAMRUP METRO | ASSAM | 781017 | ₹24.5 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹25.2 LRejected-Finance | ₹25.2 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/s Torrent Inc L4 | M/s Pragland Abhiyanta L3 | M/S PANKAJ SUPPLY SYNDICATE L7 | M/s Rawat Enterprises L5 | SHIVAM CONSTRUCTION L1 | Ms Sukumar Talukdar and Co. L2 | M/s B.M. Enterprise L8 | R. D. ENTERPRISE L9 | S.P. TRADERS L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) as specified and as directed. | 11 | Cum | 800 ₹8,800 | 700 ₹7,700 | 860 ₹9,460 | 780 ₹8,580 | 385 ₹4,235 | 350 ₹3,850 | 850 ₹9,350 | 800 ₹8,800 | 800 ₹8,800 |
| 2.00 | M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. | 330 | Sqm | 1,220 ₹4.0 L | 1,200 ₹4.0 L | 1,280 ₹4.2 L | 1,200 ₹4.0 L | 1,190 ₹3.9 L | 1,400 ₹4.6 L | 1,350 ₹4.5 L | 1,300 ₹4.3 L | 1,250 ₹4.1 L |
| 3.00 | M&L for 75 mm thick cement concrete type C- 2,1:3:6 (40mm graded aggregate) as in sub-base complete all as specified and as directed. | 330 | Sqm | 650 ₹2.1 L | 650 ₹2.1 L | 620 ₹2.0 L | 630 ₹2.1 L | 510 ₹1.7 L | 550 ₹1.8 L | 620 ₹2.0 L | 680 ₹2.2 L | 700 ₹2.3 L |
| 4.00 | M&L for 75 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in plinth protection, surface finished fair and even, laid to slope of 1:30 in alternative bays not exceeding 3 meter in length, 12 mm wide and 50 mm deep joints shall be provided along the wall and bays and same shall be filled with mastic filling to full depth comprising mixture of heated blown bitumen 85/25 grade with two parts of sand, complete all as specified and directed. | 80 | Sqm | 720 ₹57,600 | 680 ₹54,400 | 620 ₹49,600 | 780 ₹62,400 | 515 ₹41,200 | 400 ₹32,000 | 800 ₹64,000 | 700 ₹56,000 | 750 ₹60,000 |
| 5.00 | M & L for cleaning of all loose dirt & dust from roof surfaces and applying roof treatment as under:- (a) complete removal of existing roof treatment layer at any height.
(b) Applying one coat of bituminoios primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry.
(c) Applying a coat of hot blown bitumen 85/25 grade @ 1.20 Kgs / Sqm over primer.
(d) Supply and laying of 3mm thick minimum polymeric water proofing membrance weighting not less than 3 kG/ Sqm black finish reinforcement with non woven polyster matt with help of torching with propane or butane gas torch with minimum 75mm side overlap and 100 mm end overlap as per manufacturar instruction
Note: (A) The net area of water prooofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
(B) PCC & Plaster levelling course shall be measured and paid separately. | 500 | Sqm | 900 ₹4.5 L | 900 ₹4.5 L | 960 ₹4.8 L | 920 ₹4.6 L | 658 ₹3.3 L | 650 ₹3.3 L | 950 ₹4.8 L | 1,050 ₹5.3 L | 925 ₹4.6 L |
| 6.00 | M&L for 40 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) Finishing cement concrete surface even and smooth without using extrra cement as specified and as directed. | 540 | Sqm | 450 ₹2.4 L | 425 ₹2.3 L | 510 ₹2.8 L | 455 ₹2.5 L | 355 ₹1.9 L | 240 ₹1.3 L | 500 ₹2.7 L | 520 ₹2.8 L | 500 ₹2.7 L |
| 7.00 | M&L 10 mm thick rendering in cement mortar (1:4) on brick or concrete surfaces complete all as specified and directed. | 500 | Sqm | 365 ₹1.8 L | 325 ₹1.6 L | 320 ₹1.6 L | 480 ₹2.4 L | 280 ₹1.4 L | 200 ₹1 L | 400 ₹2 L | 400 ₹2 L | 350 ₹1.8 L |
| 8.00 | M&L for 150 mm thick cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in sub-base complete all as specified and as directed. | 56 | Sqm | 1,320 ₹73,920 | 1,280 ₹71,680 | 1,450 ₹81,200 | 1,300 ₹72,800 | 1,020 ₹57,120 | 799 ₹44,744 | 1,450 ₹81,200 | 1,320 ₹73,920 | 1,500 ₹84,000 |
| 9.00 | M&L for Prepolished chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx20 to 22mm thick set & jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement complete all as specified and as directed by Engineer-in-Charge. | 80 | Sqm | 1,500 ₹1.2 L | 1,380 ₹1.1 L | 1,780 ₹1.4 L | 1,320 ₹1.1 L | 985 ₹78,800 | 1,200 ₹96,000 | 1,400 ₹1.1 L | 1,550 ₹1.2 L | 1,500 ₹1.2 L |
| 10.00 | S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.0 Sqmm drawing into and including PVC casing and caping of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor (green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge.
Make : KEI/Havells/Anchor/polycab
Note : (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through conduit.
(ii) Two run of 6.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 6.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit. | 182 | Per RM | 500 ₹91,000 | 480 ₹87,360 | 540 ₹98,280 | 650 ₹1.2 L | 560 ₹1.0 L | 450 ₹81,900 | 700 ₹1.3 L | 520 ₹94,640 | 500 ₹91,000 |
Tender Value
Refer Docs
EMD Value
₹48,460
Closing Date
5 Mar 2026, 6:00 pmClosed
GE (AF) BORJHAR
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015, Tele 0361 - 2840127
Provn of certain works services at 11 ASC under GE (AF) Borjhar
2026_MES_752250_1
8536/BOR/E8
Open Tender
Civil Works
180 days
GE (AF) BORJHAR
MES Contractor enlisted as Class E category a(i) and having deposited Standing Security of Rs 1,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
7 documents required · 7 mandatory
₹500
GE (AF) Borjhar
₹48,460
Yes
13 May 2026
11 Feb 2026
7 Mar 2026
11 Feb 2026
5 Mar 2026
25 Feb 2026
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) as specified and as directed.
M&L for Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
M&L for 75 mm thick cement concrete type C- 2,1:3:6 (40mm graded aggregate) as in sub-base complete all as specified and as directed.
M&L for 75 mm thick PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in plinth protection, surface finished fair and even, laid to slope of 1:30 in alternative bays not exceeding 3 meter in length, 12 mm wide and 50 mm deep joints shall be provided along the wall and bays and same shall be filled with mastic filling to full depth comprising mixture of heated blown bitumen 85/25 grade with two parts of sand, complete all as specified and directed.
M&L for 40 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) Finishing cement concrete surface even and smooth without using extrra cement as specified and as directed.
M&L 10 mm thick rendering in cement mortar (1:4) on brick or concrete surfaces complete all as specified and directed.
M&L for 150 mm thick cement concrete type C- 2, 1:3:6 (40mm graded aggregate) as in sub-base complete all as specified and as directed.
M&L for Prepolished chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx20 to 22mm thick set & jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement complete all as specified and as directed by Engineer-in-Charge.
S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 6.0 Sqmm drawing into and including PVC casing and caping of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 6.0 Sqmm as a earth continuity conductor (green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as specified and directed by Engineer-in-Charge. Make : KEI/Havells/Anchor/polycab Note : (i) Rates are deemed to be included chases of sinking for boxes cutting and making holes in wall/floor for passing in or through conduit. (ii) Two run of 6.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 6.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Supply and fix in repairs of DB 4 way MCB TPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed.
Supply & fix in repair of MCB TPN 63 Amps 'C' Series 10 KA, 415 volts complete all as specified and directed.
Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through manually.
Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for HDPE Double wall corrugated pipe of size 63/50 mm as per IS: 16098 Part-II-2013 and ISO 21138 & BSEN 13476-1TO 3 laid in trenches/ wall for protection cables complete all as specified and directed.
S&F Double wall corrugated pipe coupler for pipe size 63/50 mm all as directed by Engr-in-Charge.
S&L in repair of UG cable XLPE insulated,armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross section area incl taking down of size 25 sq mm 3.5 core complete all as directed.
Supply and fix in repairs of DB 4 way MCB SPN double door, glazed type, IP 43 protection,Glazed door, isolated neutral bar, insulated bus bar assembly, mechanical strength of IK09, complete all as specified and directed.
Supply & fix in repair of MCBs single pole (SPN) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed.
Supply & fix in repair of MCBs single pole (SP) 6 to 32 Amps with 10 KA breaking capacity of 'C' series in distribution boards confirming to IS/IEC 60898-1 (ISI marked) complete all as specified and directed.
Supply and install hi wall split AC (5 star rating) units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton all as specified and directed.
S&F Sheet metal enclosure having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp.
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_842549.xls
BOQ • 0.33 MB
Tndr8536.pdf
Tender Documents • 1.15 MB
Download all tender documents and submit your bid