Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹16.7 L+₹2.0 L (13.4%)Rejected-Finance 178 A BARODIA SCHEME NEAR RAILWAY STATION NEAR RAILWAY STATION BANI PARK JAIPUR RAJASTHAN 302006 UDYAM RJ 17 0169767 | JAIPUR | RAJASTHAN | 302006 | L2 | Rejected-Finance L2 | |
| 3 | L3₹17.3 L+₹2.5 L (17.0%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹17.7 L+₹2.9 L (19.8%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹18.2 L+₹3.4 L (23.2%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
29 Oct 2021, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR / MAINT OF INTERNAL ELECTRIC WORKS IN CERTAIN MD ACCN OF ZONE-IB AREA AND REPAIR / MAINT OF INTERNAL WIRING AND FITTINGS INCL REPLACEMENT OF OLD LIGHT FITTINGS AT COMMAND OFFICE JAIPUR MIL STN
2021_MES_478117_1
GE/J-25/2021-22
Open Tender
Civil Works
Item Rate
270 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹60,000
Yes
13 Dec 2021
27 Sept 2021
31 Oct 2021
27 Sept 2021
29 Oct 2021
13 Oct 2021
27 Sept 2021 - 10 Oct 2021
Amount
Taking down carefully surface aluminum or copper point wiring from exisitng PVC concealed conduit for (light, fan, socket, bell or power) including fixture and fittings such as switches, ceiling rose, regulators, sockets, light fittings etc and making good disturbed surfaces complete.
All as per item No 1 above but with conduit/casing capping
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into existing concealed conduit and including sunk type modular metal flush boxes 1.0mm thick for mounting modular cover plate & frame, switches, sockets, fan regulators as required for one light point controlled by one switch.
All as per item No. 03 here-in-before but one fan point controlled by one switch.
All as per item No. 03 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 03 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into into existing concealed conduit and terminated in and including sunk type modular metal flush box 1 mm thick for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 1.5 single core Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 1.5 Sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenoic laminated white sheet cover for mounting switches, scokets, fan regulators as required for one light point controlled by one switch.
All as per item No. 08 here-in-before but one fan point controlled by one switch.
All as per item No. 08 here-in-before but one light point controlled by two, two way switch.
All as per item No. 08 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 08 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
All as per item No. 08 above but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated unsheathed FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) and earth continuity conductor 4.0 Sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings/fixing accessories and unwelded sunken galvanised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets as required for one 16 Amps socket outlet point controlled by one switch on independent board.
M&L for point wiring with 1100 volts grade PVC insulated unsheated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase-Red, Neutral-Black) single core and earth continuity conductor 1.5 Sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into and including PVC casing-capping not less than 32x16 mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0 mm covered with 3mm thick phenolic laminated white sheet cover/ mounting switches, sockets, fan regulators one light point controlled by one switch.
All as per item No. 15 above but one fan point controlled by one switch.
All as per item No. 15 above but one light point controlled by two, two way switch.
All as per item No. 15 above but one socket outlet 6 Amps controled by one switch on the same board with other switches.
All as per item No. 15 above but one socket outlet 6 Amps controlled by one switch on independent board.
All as per item No. 15 above but one bell point controlled by one bell push.
M&L for point wiring with 1100 volts grade PVC insulated unsheated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase-Red, Neutral-Black) single core and earth continuity conductor 4.0 Sqmm (Green) PVC insulated unsheathed multistranded, copper conductor, single core, FRLS drawn into and including PVC casing-capping not less than 32x16mm ISI marked ivory colour with all fittings/fixing accessories and unwelded sunken galvnised pressed steel terminal boxes of thickness not less than 1.0mm covered with 3mm thick phenolic laminated white sheet cover / mounting switches, sockets for one 16 Amps socket outlet point controlled by one switch on independent board.
S&F angle holder, insulated polycarbonate body with back plate complete.
S&F switch piano flush button single pole one way 6 Amp complete.
S&F switch piano flush button single pole one way 16 Amp complete.
S&F Switch flush type, 6 Amp, single pole, two way complete.
S&F bell push, flush type, 6 Amps 240 volts complete.
S&F socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F wire less door bell AC 240 volts, single pole complete.
S&F in repair switch piano flush button single pole one way 6 Amp complete.
S&F in repair switch piano flush button single pole one way 16 Amp complete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 & 16 Amps flush type compete.
S&F in repair socket outlet, 2-in-1, 3 pin 6 Amps flush type compete.
S&F in repair hum free electronic step fan regulator 120-280 volts of 100 watts capacity (socket type) including connecting up complete.
S&F in repair ceiling rose 3 plates polycarbonate body complete.
S&F in repair switch modular 1 way 6 Amps, 230 volts, 1 module.
S&F in repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts.
S&F in repair modular switch 1 way 16 Amps, 230 volts, 1 module.
S&F in repair modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S&F in repair modular fan regulator 120 watts, 2-module AC 230 Volts.
S & F in repair modular blanking plate 1 module.
S&F in repair modular whiter cover plate with frame 3 module.
S&F in repair modular whiter cover plate with frame 4 module.
S&F in repair modular whiter cover plate with frame 6 module.
S&F in repair modular whiter cover plate with frame 8 module.
S&F in repair Modular metal flush box 3 module
S&F in repair Modular metal flush box 4 module
S&F in repair Modular metal flush box 6 module
S&F in repair Modular metal flush box 8 module
S&F in repair switch modular 1 way 6 Amps, 230 volts, 1 module as per existing make and size Complete
S&F in repair modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts. as per existing make and size Complete
S&F in repair modular switch 1 way 16 Amps, 230 volts, 1 module as per existing make and size Complete
S&F in repair modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.as per existing make and size Complete
S&F in repair modular fan regulator 120 watts, 2-module AC 230 Volts.as per existing make and size Complete
M&L for submain wiring with two runs of single core PVC insulated and unsheathed, multistranded FRLS copper conductor of size 6.00 sqmm, LT cable, 1100 volts grade and one run of 6 sqmm single core, multistrand copper conductor (green) as earth continuity conductor drawn through existing concealed conduit complete all as specified and directed.
All as per item No. 56 above but 10 Sqmm and drawn through and including 25 mm dia or higher PVC non metallic concealed conduit with all accesories and fittings.
All as per item No. 56 above but 1.5 Sqmm
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit) and water pipe 20 mm GI, medium grade with funnel and wire mesh, PCC pit in mix 1:3:6 type C1 and RCC cover with handle, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
S & F engegement light with acralic cover with 2 nos holder fixing in wall and celing complete
S & F LED lamp of B-22 Based red colour for engegement light complete
S & F LED lamp of B-22 Based Green colour for engegement light complete
S&F in repair MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series SPN 10 to 32 Amps, 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair MCBs of 'C' series TPN 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F MCCB four pole, 125 Amps, 16 KA thermally adjustable between 70 to 100% including 4 spreader link set of same make as that of MCCB for connection, required lugs as required.
S&F in repair MCBs of 'C' series four pole 63 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete.
S&F in repair LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 125 lumen per watt and total power consumption not more than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete Make - Philips ref Cat Part No BN 308 C LED 20S -6500 L120 PSU WH or equivalent .
S&F LED fixture 10 watt having lumen output 100 lumens per watt including connection.
S&F LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable complete.
Taking down MCB distribution boards with incoming and outgoing controls any make any capacity after disconnecting complete.
S&F in repair recess mounted LED panel of size 1'x1', 17 watts 1500 lumen output having luminous efficacy >85 lm/W, 6500K, 50Hz, p.f. >0.90, CRI80, THD <30%, , Long Life 25000 burning hours including making connection Complete.Make - Philips ref Cat Part No RC 375B LED 15S W30L30PCV IN or equivalent as approved by GE,
Supply and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 2'x2' grid ceiling with fullglow fully diffused diffuser and lumen output of 3600 lumens having constant current electronic driver of 36 watt duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required. Make - Philips ref Cat Part No RC 308B LED 36 S -6500 G4 L60 W 60 PSU OD or equivalent as approved by GE,
Supply and fixing in repairs energy efficient recessed mounted LED luminaire suitable for 180 mm dia ceiling with flat diffuser and lumen output of 115 lumens per watt of 18 watt having constant current electronic driver duly connected with 0.5 sqmm white colour PVC insulated & sheathed three core flexible multi stranded copper conductor cable as required PF not less than 0.95 ITHD less than or equal 10% operating voltage 140-270 Volt .
Supply and fix in repair of aviation light single LED of 6 watt including fixing arrengemet and coneection complete .
Taking down carefully sub main wiring with PVC casing capping/PVC surface conduit and making good disturbed surfaces complete.
Supply and fix in replacement of Leonlight LED Picture light , Full matal lamp with swivel lamp LED of 8 watt including electric conecction complete.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one Double pole MCB 20 Amps
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 12 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 4 ways.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with TPN 415 volts, 4 ways.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300 mm
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 mm
Taking out old u/s LT Panel complete and Supply, installation, testing and commissioning of LT panel board fabricated out of 2mm thick stainless steel (SS 316) with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 200 Amps 415 Volts indoor type wall mounted of size not less than 750mmx650mmx250mm, installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insualated stranded copper conductor cable of 1.0 Sqmm including LED indicator for R, Y & B and comprising of the following :- Incoming : One number MCCB 125 Amps 4 pole 16 KA 415 Volts, 70-100%, 50 Hz Outgoing : (a) MCB DP 40 Amps 'C' series 10 KA AC 240 volts-05 Nos. (b) Fixing only old serviceable Single phase tamper proof meter with optical port 10 to 60 Amps-04 Nos. Note :- Serviceable meter retrieved vide this item shall be reused.
Taking down existing old u/s LT panel complete and Supply, installation, testing and commissioning of LT panel board fabricated out of 3.15 mm thick powder coated CRCA Sheet with copper bus bar 4 pole equal of capacity in colour code R, Y & B, 250 Amps 415 Volts indoor type floor mounted angle iron size 40x40x6 mm frame all as per required site of size not less than 1.3 mtr 1.1 m 0.3 m , installed on procelain insulators with bus bar chamber. The panel shall be dust and vermin proof, protection class IP 42 class, front opening & compartmental type with approach for cable entry and for easy maintenance duly internally wired with FRLS, PVC insualated stranded copper conductor cable of 2.0 Sqmm including LED indicator for R, Y & B , 3 Phase Volt meter Digital type and comprising of the following :- Incoming : One number MCCB 125 Amps 4 pole 25 KA 415 Volts Outgoing : (a) MCB 63 Amps 4 pole 25 KA 415 Volts, 70-100%, 50 Hz - 02 Nos (b) MCB 32 Amps 10 pole
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 including 15 mm thick cement plaster in CM (1:6) and 2 coats of white/colour washing to match the surface complete.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard and dense soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point.
M & L for filling clean and dry sand cushioning for cable including punning in trenches complete.
Supply and laying of bricks old size class 'B' for protection of cable laid in trenches flat with width equal to length adjoining to each other complete
Dismantling and taking out UG cable any size and removing from site, all as directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 15 Sqmm nominal cross section 4 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps,nuts, bolts washers complete all as specified and directed.
S&F 1100 volt grade heavy duty XLPE cable with PVC insulated aluminum conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 Sqmm nominal cross section 2 core laid in trenches,fixed to pole or passing through pipes including all necessary clamps,nuts, bolts washers complete all as specified and directed.
S&F door bell AC 240 Volts Single Pole complete.
Schedule of Credit
M/s Bhavesh Construction Company
M/S JALANDRA CONSTRUCTIONS
JAGDAMBA CONSTRUCTION COMPANY
SHREE BHAGWATI ENTERPRISES
S.R.Enterprises
M/s Prakash Enterprises
M/S Sheeba Enterprises
Stuti Trading Company
Deep Contractor
M/S Anil Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .