Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹47.8 L+₹2.3 L (5.16%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted | |
| 3 | L3₹47.9 L+₹2.4 L (5.35%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted | |
| 4 | L4₹48.0 L+₹2.5 L (5.48%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | L4 | Rejected-Finance Higher rate quoted | |
| 5 | L5₹49.2 L+₹3.7 L (8.11%)Rejected-Finance VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | L5 | Rejected-Finance Higher rate quoted |
Tender Value
₹49.3 L
EMD Value
₹98,600
Closing Date
19 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_533926_2
8400-824/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D, Cat a (i)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹98,600
Yes
15 Nov 2022
29 Jul 2022
20 Aug 2022
29 Jul 2022
19 Aug 2022
5 Aug 2022
60 days
Amount
Excavating over areas, n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed
M&L for 200mm thick mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (i.e. 10% fly ash, 30% clinker and 60% stone dust) laying in layers n.exc 30cm hick, watering, ramming and compacted with vibratory/power roller 8 to 12 ton to required camber and gradient complete all as specified and directed by Engineer-in-Charge.
M&L for hardcore of broken stone or boulder of gauge exc 63mm but n.exc 75 mm deposited, spread & levelled in lyers n.exc 15 cm thick watered & rammed to a true surface complete all as specified and directed.
M&L for 100 mm thick, cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 75 mm thick, cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in floor/sub base complete all as specified and directed.
M&L for sand filling under floor in foundation including watering and consolidation complete all as specified and directed
Removing surplus excavated spoil/earth to a distance n.exc.50m and deposited where directed at a level n.exc.1.5m above the starting point complete all as specified and directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in kerb including necessary form work complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 with mixture of grey cement and pigments of 60 mm thickness, M-35 Grade with grey cement and pigments complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with mixture of grey cement and pigments complete all as specified and directed
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and directed
M&L for plain cement concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed
M&L for RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate) beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for brick work with flyash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:6) complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed
M&L for 15mm thick in CM 1:4 rendering on brick or concrete surfaces finished even and smooth with integral water proofing compound on wall complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
Providing precast cement concrete louvres and jallies, 25mm thick (measured solid), including all mouldings but excluding frame complete all as specified and directed (Note: Pre-cast frame shall be measured separately and paid for under item set in CM (1:4)).
M&L for mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed
All as per item No 20.00 mentioned here-in-above but 6 to 8mm complete all as specified and directed
All as per item No 20.00 mentioned here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm in soft loose soil complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
S&F rolled mild steel in plates channel (plain or chequred) square cut or notched (ordinary and counter shunk) forming holes, withpout any attachment of quality FE 410-W (Gde-E-250) quality-A complete all as specified and directed
S&F steel work in tubular trusses, purlins, posts etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S-1161- 1979 grade St.-240 complete all as specified and directed
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on newly steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces complete all as specified and directed
S&F pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in ridges, fixed with self tapping screws complete all as specified and directed
M&L for moorum filling in floors or pavements, laid in layers n.exc. 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for flat iron fillets (for securing wire mesh, CGI Sheets etc.), including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Surface dressing n.exc 15 cm deep and getting out in soft/loose soil complete all as specified and directed
Excavation in trenches in any type of soil n.exc 1.5 m wide and exc 1.5 m but n.exc 3,0m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sqm on plan and getting out complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in chajjas complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) columns, pillars, piers, posts and struts complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in fins/fascia complete all as specified and directed
M&L for half brick work with fly ash bricks old size straight or curved on plan to any radius exc 6m mean radius build in CM (1:4) complete all as specified and directed
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for fair finished surface of concrete complete all as specified and directed
Formwork to chullah hoods, cha?jjas, troughs and similar items in?cluding ege for fair finished surface of concrete complete all as specified and directed
Formwork to fins , louvers, fascia for fair finished surface of concrete complete all as specified and directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete complete all as specified and directed
S&F butt hinges mild steel 100mm long, medium weight, cooled rolled complete all as specified and directed.
S&F 150mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S&F 150mm long extruded Aluminium anodized barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F aluminium alloy, 250mm long anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F wire netting of stainless steel wire 0,91mm dia fixed with tinned tacks of stainless steel wire staples complete all as specified and directed
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge complete all as specified. complete all as specified (either for openable/sliding shuttters) including all necessary fittings as directed
M&L for 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) to receive tiles complete all as specified and directed.
M&L for joint free non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 Sqm but n.exc 0.11 sqm in floors set and jointed in neat cement slurry and pointed in coloured cement to match the shade using coloured tiles incl 15mm thick screed bed in cement mortar (1:4) complete all as specified and directed.
M&L for 75 mm thick, cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate), as in sub base complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth protection finished even and smooth with out using extra cement complete all as specified and directed
Supply only intergral water proofing compound complete all as specified and directed (Makes : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for 15mm thick in cement plaster CM (1:6) on brick or concrete surfaces finished even and smooth without using extra cement on wall complete all as specified and directed
M&L for rendering 5 mm thick in CM (1:3) on ceiling finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for 10mm thick in cement plaster CM (1:4) on brick or concrete surfaces finished even and fair with using water proofing compound complete all as specified and directed
M&L for preparation new surface of roof and applying two coat of polyurethene (PU) acrylic based water proofing liquid compound over & including one coat of self priming primer @one litre per 10 sqm with reinforcing fabric sheet as per manufactures instruction to stop leakage /seepage from roof/wall complete all as specified and directed by the Engineer-in-Charge. (Notes- 1. As per description of the items minimum two coats of polyurethene (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out by the as per manufacture instruction.pl note no price adjustment shall be made,if more coats of (PU)acrlic based water proofing liquid compound & primer are required for roof treatment. 2. Quated rate shall be deemed to be included for work in building/structure of any height).
M&L for three coats of white wash as in ceilings on newly plastered surfaces including preparation complete all as specified and directed
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; and similar work conforming to Fe.290.Gde-E-165 the grill shal be inseted in the wall surface including neceasary drilling and grouting with cement etc complete all as specified and directed
M&L for two coats of oil bound distemper over a coat of alkali resistant primer including preparion of new plastered surfaces of ceiling complete all as specified and directed (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for two coats of oil bound distemper over a coat of alkali resistant primer including preparion of new plastered surfaces of walls over a coat of 3mm thick wall care putty complete all as specified and directed (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm & Litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including Preparation of new plastered surfaces complete all as specified and directed (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar).
S&F sheet glass, 4.0 mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S&F sheet glass, 6.30 mm thick ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed
S&F rubber wood wall panelling 18mm thick fixed to wooden frame work with nailing, moulding edges at openings and panel joints including varnising complete all as specified and directed
M&L for 25mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screw complete all as specified and directed
S&F anodised aluminium snap grid frame work for false ceiling all as specified size of grid 605X605mm complete all as specified and directed
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S&F hangers 6 mm dia. GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed
S&F 4mm thick decorative non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/aluminium framework with screws fixed in ceilings complete all as specified and directed
M&L for 2nd class hard wood plain fillets square, rectangular or triangular in section, clean sawn, secured with nail cross sectional area exc 13 Sqcm but n.exc 25 Sqcm complete all as specified and directed
Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of black japan paint complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in cement concrete in surface channels and drains complete all as specified and directed
E/M PORTION M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L point wiring for socket outlet 3 pin, 5 amps on Independent board controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes/ modular, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 80.00 mentioned here-in-above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for socket outlet 3 pin, 15 amps on independent Boards controlled by one, one way switch using 4.0 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes/ modular , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
S&F switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and directed .( For Same Board only)
S&F switch socket combination 2 in 1 , 6 pin , (16 Amps ) flush type controlled by one switch complete all as specified and directed.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
S&F dimmer type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and directed
S&F bell push, flush type, 5 amp complete all as specified and directed
S&F buzzer, ding dong, AC 230 Volts, single pole 230 volts all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed
S&F switch modular type 6 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F switch modular type 16/20 Amp one way, one module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F bell push, modular type 6 Amp SP one way, 1 module complete all as specified and directed
S&F fan regulator modular step type 120W, 2 module suitable for 230 volt AC complete all as specified and directed.
S&F socket outlet modular type 6 Amp 2/3 pin, two module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F socket outlet modular type 16 Amp 2/3 pin, two module, single phase, complete all as specified and directed by Engineer-in-charge.
S&F of decorative front plate white or coloured for 8 modules complete all as specified and directed
All as per item No 98.00 mentioned here-in-above above but 3 module complete all as specified and directed
All as per item No 98.00 mentioned here-in-above but 1/2 Module complete all as specified and directed
S&F blanking plates white or coloured for 1 modules complete all as specified and directed
S&F modular power unit, 25 Amps, ISI marked, 240 Volts complete all as specified and directed.
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed
S&F submain two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F 18 W recessed mounted round LED downlight, aesthetically designed auminium die-cast enclousers, with seperate replaceable constant current driver 12 watts for grid ceiling ,including necessary connection complete all as specified and directed.
S&F 20 W LED light fitting wall mounted batten 4'ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt,6000K including necessary connection complete all as specified and directed.
S&F recess cum surface light round shape,240v, ISI mark, 18 watts complete all as specified and directed. (Make :- Havells)
S&F 18 W LED batten light fittings, with T-8 tube rode, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed.
S&F 9W LED light fitting wall mounted batten 2ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 9 watt , 6000K including necessary connection complete all as specified and directed.
S&F wall mounted type decorative LED light with LED 9 watts bulb , 50Hz complete with all accessories complete all as specified and directed.
S&F recessed mounted 2' x 2 ' LED luminaire 36 watts for grid ceiling minimumm lumen output 100 lumen/Watt, pre-treated CRCA frame powder coated with diffused Profied including necessary connection complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Vertical Triple pole and neutral 415 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP, 40 to 63 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCCB 4 pole, 3 phase, 415 volt of capacity 125 Amp, 18 KA complete with proper copper thimbles, copper reducer etc all as directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument (Meger) to be provided by the contractor at own cost).
S&F metallic Exhaust ventilation fan of sweep 300 mm sweep, 230volt AC complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with rwin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed by Engr-in-Charge. (Note:- Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates)
S&F PVC body Exhaust ventilation fan of sweep 230mm with louvers complete all as directed by Engr-in-Charge.
S&F XLPE insulated armoured cable, 16 sqmm 4 core, 1100 volts grade heavy duty cable, ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
Supply and laying of pipe GI medium grade 15 mm dia complete in wall ceiling or floor etc complete all as specified and directed
S&F stop valve fancy type CP cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe complete all as specified and directed.
S&F bib tap cast copper alloy high pressure with crutch or butterfly handle screwed for iron pipe complete all as specified and directed.
S&F PVC Connections 15 mm size with PTMT nuts of length 300 mm long, ISI marked complete all as specified and directed.
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
M/s RAJEN ROY
NATIONAL CONSTRUCTION CO
UNIVERSAL TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .