Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 Jul 2026, 6:00 pm
GE Army Jaisalmer
GE Army Jaisalmer - 345001
COMPREHENSIVE MAINT REPAIR TO ROOF TREATMENT AND SEEPAGE LEEKAGE IN TOILETS BLOCKS INCL REPLACEMENT OF TILING AND CONNECTED B/R ITEMS OF AGE BR-III UNDER GE (A) JAISALMER
2026_MES_776502_1
8128/26-27/E8
Open Tender
Civil Works
180 days
Jaisalmer
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Army Jaisalmer
₹90,000
Yes
4 Jul 2026
4 Jul 2026
27 Jul 2026
4 Jul 2026
25 Jul 2026
18 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | r in floors complete all as specified & directed by Engineer-in-charge.¢S & F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge.S & F in epair PVC (SWR) 110mm bends any radius all as specified and directed complete all as specified & directed by Engineer-in-charge.gS&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified & directed by Engineer-in-charge.S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified & directed by Engineer-in-charge.øS & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 110mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified & directed by Engineer-in-charge.©S & F n epair PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed by Engineer-in-charge.ºS & F n epair PVC (SWR) 75 mm bore pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.iS & F n epair PVC (SWR) 75mm bends any radius complete all as specified & directed by Engineer-in-charge.S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified & directed by Engineer-in-charge.÷S & F in repair stack clamps out of 50 mm by 5 mm flat iron and 16mm dia round iron stays for fixing 75mm dia PVC pipe, including bolts and nuts and securing ends of stays to wall or roof complete all as specified & directed by Engineer-in-charge.ÈS&F in repairs Tubular towel rail brass chromium plated 20 mm dia D-type 60 cm long between flanges, including brackets and fixed to walls, complete all as specified & directed by Engineer-in-charge.ES & F in repair 6mm thick of size 600x450mm looking mirror fixed to wall with stainless steel plugs/connecter/spacers/screws etc. chrome finish without any beading, including ends/edges of the mirror to be tapered etched smooth finish etc.complete fixed in position complete all as specified & directed by Engineer-in-charge. ½S&F in repair European type water closet including CI P/S trap as directed including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe PVC 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm P/S trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors G.F.and taking down existing of any description/size complete all as specified & directed by Engineer-in-charge.
S & F in repair Vitreous china squatting pan of Orissa patten size 580 x 440 white colour including CI S/P trap long size as directed joint run and lead front or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in PCC 1:2:4 complete all as specified & directed by Engineer-in-charge. ÁS & F in repair Flushing cistern of PVC 10 ltr. cap valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect complete all as specified & directed by Engineer-in-charge. ;S & F in repair Vitreous china premium/1st quality wash basin (under counter), white, size 550x400 mm including S&F all accessories as recommended by manufacturer complete fixed in position in all respect as per manufacturer's instructions and all as specified including all Waste fittings, brass,chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified & directed by Engineer-in-charge.
Note : The items for counter will be measured and paid separately. ùÿøS & F in repair Vitreous china premium/1st quality urinal bowl type of white colour, of size 330x300x450mm incl providing and fixing plugs/brackets, bedding urinal against wall in CM 1:2, securing urinals to plugs with and incl S&F of all accessories for fixing as recommended by manufacturer like 60mm long brass secrews/fasteners/rag bolts etc, pointing urinal back in white cement; connecting for discharge pipe incl necessary packing, union complete all as specified & directed by Engineer-in-charge. S&F in repair PVC connection 450mm long and 15 mm dia with brass fly nut at both ends complete all as specified & directed by Engineer-in-charge.
ðS & F in repairs brass chromium plated Health faucet with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect complete all as specified & directed by Engineer-in-charge. ¦Supply & Fixing in repair chromium plated shower rose 125mm round shape fancy type fixed to 15mm bore pipe complete all as specified & directed by Engineer-in-charge.S & F in repair Angular Stop Cock, CP, fancy type with wall flange, fancy type chromium plated cast copper alloy screwed down, high pressure, screwed ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified & directed by Engineer-in-charge.BSupply and fixing in repair of fancy type pillar taps cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shank supply and fixing ly nuts for iron pipe of 15mm bore fancy type complete all as specified & directed by Engineer-in-charge.
úS & F in repair Bib taps, CP, fancy type long nose with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete fixed as in repair in all respect complete all as specified & directed by Engineer-in-charge.,S&F in repairs 15mm bore stop valves , cast copper alloy, chromium plated fancy type with long shank cup (Concealed type) screwed down , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified & directed by Engineer-in-charge.ÂSupply and fixing in repairs PVC Flexible waste pipe 32/40 mm dia having length 900mm with socket for steel sink/WHB upto floor level complete all as specified & directed by Engineer-in-charge.M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded granite stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 including demolition of brickwork or stone/ boulder/block masonry and built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and removal unserviceable materials, debris and rubbish to a distance not exceeding 100m complete all as specified & directed by Engineer-in-charge.À78íTaking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified & directed by Engineer-in-charge.LM&L for rendering 15 mm thick readymade plaster on inner/outer walls with approved make by adding 17-19% of potable water by weight of material. For thickness above 15mm is recommended to be applied in multiple layers, Ready-mix plaster shall complies with IS-1661-1972, IS 2250-1965, IS 2402-1963 and confirms the compressive strength @ 28 Days-10-12 Mpa/ Bulk density 1500-1800 Kg/m3 complete all as specified & directed by Engineer-in-charge.
Note : The quoted rate by the contractor shall include cleaning of surface, application as per instruction and scaffolding upto 20 mtr height.708¾;Â8
M&L for preparation of newly plastered surfaces and applying Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed by Engineer-in-charge.0M&L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work complete all as specified & directed by Engineer-in-charge.ÑM & L for Applying 1mm thick wall care putty on wall for desired smoothness and levelling of surfaces in two or more layers) for receiving painting complete all as specified & directed by Engineer-in-charge.8Disconnecting existing tanks Exc 250 Ltrs but not exc 500 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified & directed by Engineer-in-charge.àM & L Cleaning and removing, Exc 250 Ltrs but not exc 500 Ltrs capacity PVC water tank all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified & directed by Engineer-in-charge.:Disconnecting existing tanks Exc 500 Ltrs but not exc 1000 Ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified & directed by Engineer-in-charge.âM & L Cleaning and removing, Exc 500 Ltrs but not exc 1000 Ltrs capacity PVC water tank all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified & directed by Engineer-in-charge.xS & F for Rotational moulded polyethylene water storage tanks of 1000 Litres capacity, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc including taking down existing tank complete all as specified & directed by Engineer-in-charge.Dismantling/Demolition of existing roof terracing of cement/brick concrete(un-reinforced) and existing water proofing treatment of any thickness in any position on top of roof of building, cleaning surface of roof with brush/mechanical brush and with water throughly to romove all dust/dirt and loose particles to expose bare concrete roof slab and romoval of rubbish/demolished material out side MD land complete all as specified & directed by Engineer-in-charge.
Note : Demolition should be done by chiselling.Ñ9Õ:ªM&L for PCC (1:2:4) Bo using 12.5 mm graded stone aggregate as in levelling padding course over RCC roof surface including rounded or chamferred on edges etc., with approved water proofing compound all as per manufacturer's instructuions on the roof surface to achieve requisite slope complete all as specified & directed by Engineer-in-charge.
Note :- Supply only water proofing compound shall be measured & paid separately. Y9]:fSupply only Liquid water proofing compound complete all as specified & directed by Engineer-in-charge. | 13 | Cum | - | - |
| 3 | M & L for applying of two component elastomeric acrylic polymer modified cementitious waterproofing coating. SmartCare Dampblock 2K or equivalent with a consumption of 1.5 Kg/Sqm in 2 coats.
Methodology-
TESTING & GROUTING: Masonry surface under treatment should be fully cured prior to application. Fill the slab with water and check the water tightness. Mark the leaking points and treat them with cement injection grout mixed with non-shrink
croutine accitive
CLEANING: Clean the surface thoroughly using a wire brush/hand grinder to ensure the surface is free from dust, mortar & loose particles
PRE-WETTING: Pre wet the surface adequately to make it SSD.
MIXING: Add powder to liquid (2 parts powder & 1 part liquid by wt.) slowly while stirring. For bulk volume use mechanical stirrer. Keep mixing until a smooth homogenous slurry without any lumps is formed. Set the slurry aside for 5-6 minutes to allow the entrapped air to escape.
APPLICATION: Apply 1st coat of SmartCare Professional Damp Block 2K slurry mixture by brush or roller over the horizontal surface and take it all over the parapet wall to form a complete envelope coat. Let the 1st coat dry for 4-6 hrs. Apply the 2nd coat
perpendicular to the ist coat. | 210 | Sqm | 10 | ₹2,100 |
| - | ITEM NO. 3.00 CONTD...
CONSUMPTION: The consumption should be approx. 1.5 Kg/m? in 2 coats. If required, the coating can be reinforced by embedding glass/polyester mess.
CURING: Cure the coating by sprinkling water for 3-5 days.
POST PONDING TEST: Perform water ponding test post curing.
PROTECTION AND SLOPE BUILT UP: The coating must be protected by Brick bat coba or screed concrete admixed with SC Vitalia Neo. Ensure proper slope is built for this brick bat coba or screed layer. If used on vertical walls the coating must be covered with cement plaster admixed with Vitalia. If the size of the terrace is more than 1500 sq. ft., a geo textile sheet (min. 80 GSM) should be loosely laid before the coba/screed concrete is placed. | - | - | - | - |
| 9 | S & F Factory made ISI marked flush door shutters 35mm thick, BWP conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 2nd class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters complete all as specified and directed by Engineer-in-charge and including supply and fixing following items :-
(a) Stainless Steel (304 Grade) Finished Butt Hinges 125mm - 4 Nos per leaf
(b) Stainless Steel (304 Grade) Finished Tower Bolt 200mm long - 2 Nos per leaf
(c) Stainless Steel (304 Grade) Finished Handles 200 mm - 2 Nos per leaf
(d) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16 x 300mm - 1 No per leaf
(e) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 No per leaf | 20 | Sqm | - | - |
| 37 | S&F in repair Urinal spreader of PTMT any colour for fixing with 15mm dia pipe. (Minimum weight 60gms). | 10 | Each | - | - |
| 49 | ࠆ♍⁌潦桃灩楰杮漠㔲 | 200 | Sqm | - | - |
| 61 | M&L for providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application incl applying evenly bitumen tack coat primer of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces and laying over finished surface with screed of 25mm thick CM 1:4 with water proofing compound complete all as specified with the following specifiations :- | 1,400 | Sqm | - | - |
| - | (a) Cleaning existing surface properly.
(b) Apply oil bound bitumen primer @ 0.40 lit/Sqm manufactured by the same agency as that of APP with a density of 0.87 -0.89 Kg/Lit at 25 Degree Centigrade on the prepared dry roof surface.
(c) Providing and Laying APP modified water proofing membrane reinforced with non wooven polyster matt with physical propertities as under :-
(i) Membrane weight >3.6 Kg/Sqm .
(ii) Net wooven polyster weight >160 gm/Sqm
(iii) Softening point of membrane > 150o C
(iv) Joint Tensile strength Longitudiual > 650 Sq Cm at 230o C & Transverse > 450/ Sq cm
(v) Tear strength - Longitudual > 300 N & Transverse > 250 N Direction
(vi) Elongation > 30 %
(vii) Impermeability under water pressure > 3 Kg/Sq cm
Note:- APP membrane shall be laid using butane torch by Torch application with minimum 10 cm side overlap and 15 cm end lap. The laying of membrane shall be got done through authorised applicator of manufacturer of membrane.
(d) Over the membrance provide a finishing with solar reflective bituminous aluminium paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_869552.xls
BOQ • 1.03 MB
TenderDocuments8128.pdf
Tender Documents • 1.65 MB
Download all tender documents and submit your bid