Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹35.8 L+₹48,027.04 (1.36%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹36.4 L+₹1.1 L (3.12%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹38.0 L+₹2.7 L (7.50%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹39.6 L+₹4.3 L (12.2%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹45.7 L
EMD Value
₹91,320
Closing Date
28 Oct 2024, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
SPL REPAIR CONVERSATION OF OH CONDUCTOR WITH UG CABLE INCL CONNECTED ITEMS AT PREM NAGAR AND CERTAIN OFFICE AREA AT 11 GRRC AND PROVN OF STREET LIGHT WITH POLES ALONG THE ROAD FROM GATE NO 2 OF RAKSF 1 TO BACK SIDE OF 3 THIMAYYA UNDER GE E/M LUCKNOW
2024_MES_677419_1
GE/EM/LKO/EXT(ELECT)/T-75 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹91,320
Yes
9 Dec 2024
30 Sept 2024
30 Oct 2024
30 Sept 2024
28 Oct 2024
14 Oct 2024
Amount
Taking down existing ACSR conductor including disconnection after taking proper written shut down from HT/ LT OH line all as specified and directed by Engr-in-Charge.
Dismantling of cross arms of MS channel or angle sections etc complete all as specified and directed by Engr-in-Charge.
Dismantling of GI wire any type and any size complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing LT / HT insulators any types and any size all as specified and directed by Engr-in-Charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft / loose soil for laying / taking up / taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
M&L for laying of well burnt old size bricks, sub class "B" bricks, straight or curved on plan, laid flat with width equal to length of brick, laid dry over electric cable for protection complete all as specified & directed by Engr-in-Charge.
Deployment of tools & manpower for Boring of hole under road / pavement / hard standing or any other situation by manual means suitable for passing of 40 to 100 mm bore pipe and making good both ends all specified and directed
Supply, laying jointing and testing LT UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured IS 7098 marked, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 4 core, laid in trench / laid under floor or fixed naked with wall / on wall / in ducts / in GI pipes etc. with and includings MS Clamps, nuts, bolts,washers complete all as specified and directed. Note- Excation, earth works, sand cushioning, protection bricks / pipe shall be measured and paid seprately.
All as per item No 11 above but LT UG cable of size 16 Sqmm 4 core.
All as per item No 11 above but LT UG cable of size 25 Sqmm 4 core.
All as per item No 11 above but LT UG cable of size 35 Sqmm 3.5 core.
All as per item No 11 above but LT UG cable of size 50 Sqmm 3.5 core.
All as per item No 11 above but LT UG cable of size 70 Sqmm 3.5 core.
All as per item No 11 above but LT UG cable of size 95 Sqmm 3.5 core.
All as per item No 11 above but LT UG cable of size 120 Sqmm 3.5 core.
All as per item No 11 above but LT UG cable of size 185 Sqmm 3.5 core.
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
M&L for Earth continuity conductor or main earthing lead laying to treanches & fixed to pole 4 mm dia galvanised iron wire.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 25 to 50 Sqmm XLPE armoured aluminium conductor.
S&F Cable jointing kit for 1100 V (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core 70 to 95 sqmm XLPE armoured aluminium conductor
M&L for 40 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 50 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 80 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for 100 mm bore mild steel galvanised water tubing, light grade with all fittings and fixed to walls or laid on floors / fixed to poles / or passing under road crossing, for protection of UG cable complete all as specified and directed by Engr-in-Charge.
M&L for cutting of PCC / Hard standing / WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen / PCC (1:3:6) type C-1 complete all as specified and directed .
S&F Wheather proof pole mounting junction box, base and door of junction box made out of SMC having outside dimention 333 x 233 x120mm, inside dimention 300 x 200 x 105 mm, single door front openable provided with hinged cover and locking arrangements with 4 Nos aluminium bas bar 63 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including embossing / painting of danger notice of size not less than 10 cm x 7.5 cm with letters, figures and conventional skull and bones in signal red colour on front face of junction box body Complete all as directed by Engr-in-Charge
Material and labour for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Supply, installing, testing and commissioning in factory made, CPRI approved powder coated Timer panel board (Dimention of Cubical / enclosure not less than 600mm x 450 mm x 450 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The timer panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA MS sheet, inner shell made of 2.0 mm thick CRCA MS sheet, 40 x 40 x 6 mm thick MS angle iron frame work, the cubical have bottom support of angle iron 50 x 50 x 6mm duly coated with zink metal coating,front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following :-
(a) Incoming :- (i) MCCB 4 pole , 63 Amps, 50 Hz, 415 Volts, 16 KA, with thermal magnetic release - 01 Nos (ii) 3 pole power contractor AC 3 rating 40 Amp, 240 Volt AC -01 Nos (iii) Astronomical Digital Timer Switch 240 V AC -01 Nos (iv) Digital VAF+PF meter with RS 485 Cl-1 -01 No (v) CTs ratio 200 / 5 A ,class 1, ISI marked -01 sets of three (vi) Indicating lamp- 01 set of three (vii) Four Pole, Aluminium bus bar 150 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 40 Amps,50 Hz,415 Volts, 16 KA thermal magnetic release - 02 Nos.
(c)- Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
Supply, installing, testing and commissioning factory made, CPRI approved, powder coated LT Panel board (Dimention of Cubical / enclosure not less than 1700 mm x 1300 mm x 800 mm), cubical compartmentalized, out door type double door, plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain / SMC insulator. The panel shall be dust and vermin proof IP-54 class protection and outer shell made of of 3.15 mm CRCA sheet, inner shell made of 2.0 mm thick CRCA sheet, 50 x 50 x 6 mm thick MS angle iron frame work, the cubical have bottom channel of size 75 x 40 mm duly coated with zink metal coating, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following:-
(a) Incoming :- (i) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 25 KA thermal magnetic release - 02 Nos (ii) MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA thermal magnetic release - 06 Nos
(c)- Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
All as per item No 33 above but size of panel 1000 mm x 750 mm x 600 mm and comprising the following:- (a) Incoming :- (i) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 03 Nos (ii) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 01 Nos
All as per item No 33 above but size of panel 1000 mm x 750 mm x 600 mm and comprising the following:- (a) Incoming :- (i) MCCB 4 pole, 300 Amps, 50 Hz, 415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 300/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 600 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 03 Nos
All as per item No 33 above but size of panel 1000 mm x 750 mm x 600 mm and comprising the following:- (a) Incoming :- (i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos (ii) Digital VAF+PF meter with RS 485 CL1 -01No (iii) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three (iv) Indicating lamp- 01 set of three (v) Four Pole , Aluminium bus bar 400 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators.
(b) Outgoing (i) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 01 Nos (ii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA, with thermal magnetic release - 03 Nos
M&L for outdoor type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 500 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 250 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
M&L for outdoor type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of 3.15 mm thick MS sheet and MS angle section 50 x 50 x 6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 160 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
M&L for outdoor type busbar panel board (Dimention of Cubical / enclosure not less than 600 mm x 450 mm x 450 mm) made out of 3.15 mm thick MS sheet and MS angle section 50x50x6 mm factory made suitable for 3 phase 4 wire 415 Volt, 50 Hz, powder coat painted comprising of the following:- (a) FP, Aluminium bus bar 800 Amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “F” class insulators. (b) Incoming MCCB 400 Amps 36 KA, 415 Vots, 50 Hz, FP. – 1 No (c) LED Indicator lamp RYB - 01 set of three.
Supply and errection 07 mtr continuously tapered hot dip galvanised Octagonal cross sectional pole with single dipping method having bottom 130 mm A/F and top 70 mm A/F 3 mm thick confirming to ASTM A 572 Gr with yield 450 mpa cut and folded to form an octagonal section and welded in accordance with AWS for wind loading as per IS 875 part 3 1987.Poles shall be provided with base plate of size 225x225x12 mm which shall be free from any lamination or incursion with no cutting or welding on the pole after hot dip galvanising with single arm 1000 mm long bracket tilted to 150 degree from horizontal toward vertices suitable for mounting on the octagonal pole, of company recommendation and one no TPN Connecton 3 phase 4 wire 100 Amps, and one number MCB SP 6 Amps. A triangular flat MS plat of 6mm thick duly coated with GI shall be welded between cap of the octagonal pole and bracket. Welding work shall be done 250 mm on bracket and 150 mm on pole's cap including all RCC work type (1:2:4) type B-1 including 04 Nos foundation nut bolt and plate as per pole manufacturer's drawing and earth work all as per requirement complete all as specified and directed. Note:- Cost of construction of RCC foundation including construction material, necessary earth work and excavaton as per manufacturer design for above pole complete all as required at site and as directed by Engr-in-charge are deemed to be included in the quoted rate.
Supply and fix 70 W pressure Die cast aluminium housing street light with system lumen of 9800 lm & system efficacy of 140 lm / W, IP66, IK10, Single piece die cast including spigot, dia 48-76 mm, LED Lifetime (L70B50) 75K Hrs with integrated optical cover, Street light should have standalone lighting control system with AUTO on / off based on Dusk / Dawn timings, preset time setting with monthly variation (Jan to Dec.), inbuilt Real time clock for switching, includes dimming profile for energy savings, drift not exceeding max 2 mins per year, clock retention upto five years, auto switching off secondary power for module, dimmable driver based on PWM control, dim to off with High / Low Voltage cut off with 440V protection for 8 hrs for complete luminaire including driver and Astro module, EMI / EMC complaint as per EN55015,IEC61547, surge protection as per IEC 61000-4-5,driver meeting IEC61347, complete luminaire meeting IEC60598-2-3-2002, Luminaire manufacture shall provide LM 79 report from NABL / UL accredited lab & LM80 report issued by LED manufacturer, both the fixture and Driver should be of same make & must have separate BIS approval complete all as specified & directed.
Prime power system (BID ID -3146270)
GYAN ENTERPRISES (BID ID -3150562)
M I & CO. (BID ID -3151224)
Avion Industries (BID ID -3146336)
MTR GROUP & COMPANY (BID ID -3152352)
Ajanta Associates (BID ID -3145756)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .