| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC Being First Lowest | |
| 2 | L2₹38.5 L+₹2.7 L (7.61%)Rejected-Finance | L2 | Rejected-Finance Other Than First Lowest | |
| 3 | L3₹41.7 L+₹6.0 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Other Than First Lowest | |
| 4 | L4₹44.5 L+₹8.8 L (24.5%)Rejected-Finance | L4 | Rejected-Finance Other Than First Lowest | |
| 5 | L5₹46.4 L+₹10.6 L (29.7%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L5 | Rejected-Finance Other Than First Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
19 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
REPAIR / MAINT OR REPLACEMENT OF MISC E/M ASSETS AND LT DISTRIBUTION PANELS AT LGJ MIL STN
2022_MES_509293_1
8932-82/21-22
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
As per tender documents
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹96,000
Yes
1 Apr 2022
19 Feb 2022
21 Mar 2022
19 Feb 2022
19 Mar 2022
5 Mar 2022
60 days
Amount
M/L for Maintenance and servicing of DG Set of capacity 250 KVA Make: Kirloskar/ Cummins complete including following :- (a) Draining out engine oil from the chamber cleaning the chamber thoroughly and refilling the sump with new engine oil to it’s required level, (b) Draining out of diesel from tank , cleaning the tank thoroughly and refilling the drained out diesel (c) Supply and replacment of fuel filter set (d) Supply and replcement of lubricating oil filter set (e) Supply and replacent By pass filter set (f) Checking & cleaning air cleaner (g) Check and topping up coolant level (h) Checking the starting batteries and filling with electrolyte/Distilled water to maintain the required specific gravity. Cleaning of Battery terminals & applying petroleum jelly to battery terminal posts & brass connectors (j) Checking and clearning exhaust system including removing of deposited carbon in exhuast pipe. (k) Adjustment /setting of V Belt and fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer (l) Checking, cleaning and servicing of self stater, Alternator, sensors etc. (l) Testing of DG set at connected load all as directed by the Engr in charge. Note (a) Fuel filter, oil filter, bypass filter, water filter, petroleum jelly, waste cloth, seal, gaskets etc are to be provided by the contractor and the cost is deemed to be included in quoted rate. (b) Coolent for topping up measured and paid saparetly (c) Engine oil /Spares/filters of make reccomended by OEM will only be used for servicing of DG set
,---ditto--- All as per item No. 1 above but for 200 KVA Make Kirloskar DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 160 KVA Make Cummins DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 125 KVA Make Cummins DG Set complete all as specified and directed by Engr-in-charge.
Al,---ditto--- All as per item No. 1 above but for 63 KVA Make Cummins/Greaves Cotton DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 62.5 KVA Make Cummins/Greaves Cotton DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 50 KVA Make Mahindra Powerol DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 45 KVA Make Ashoka Leyland/Mahindra Powerol DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 40 KVA Make Ashoka Leyland/Mahindra Powerol DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 35 KVA DG Make Mahindra DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 30 KVA DG Make Mahindra DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 25 KVA DG Make Mahindra DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 15 KVA DG Make Mahindra DG Set complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 1 above but for 10 KVA DG Make Mahindra DG Set complete all as specified and directed by Engr-in-charge.
M & L for draining existing radiator, cleaning thoroughly the radiator fins by air blower recharging the chemically treated coolant including replacement of all water hose pipe suitable for 30 KVA to 62.5 KVA DG Sets complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 15 above but for 125 to 160KVA DG Sets complete all as specified and directed by Engr-in-charge.
,---ditto--- All as per item No. 15 above but for 200 KVA to 250 KVA DG Sets complete all as specified and directed by Engr-in-charge.
M & L for dismantling the self starter 12 / 24 Volts DC of DG sets and transporting to work shop for carrying out overhauling by replacing all unserviceable spares including pinion, reassembling and refixing the same to DG sets including testing complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC insulated multistranded copper conductor cable of suitable length each soldered with 02 Nos gun metal battery terminals suitable for 80/150/180 AH and 12/24 Volts DC supply complete all as specified and directed by Engr-in-Charge.
Supply and topping up of coolent for DG set in sealed container Make :CASTROL complete all as specified and directed by Engr-in-Charge.
Taking out defective fuel injection pump of DG set Cap 30 KVA to 62.5 KVA , transporting to work shop and clearning of injectors nozzles and overhauling complete including calibrating and re-fixing the same including testing the DG Set to the entire satisfaction of Engineer-in-charge.
,---ditto--- All as per item No. 21 above but for 200 KVA to 250 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
Taking out defective old flexible fuel pipe from DG set including supply and fix new flexible fule pipe 15 mm suitable clips accsesories complete all as specified and directed by Engr-in-Charge.
Supply in replacement of battery maintenance free 12 volts 150 AH including initial charge and connected DC cable thimble nut, bolts etc including testing complete all as directed by engineer-in-charge.Make Exide
Supply and replacement of battery maintenance free 12 volts 180 AH including initial charge and connected DC cable thimble nut, bolts etc including testing complete all as directed by engineer-in-charge.Make Exide
Supply in replacement of battery maintenance free 12 volts 80 AH including initial charge and connected DC cable thimble nut, bolts etc including testing complete all as directed by engineer-in-charge.Make Exide
Supply in installed testing, commissioning in replacement of AVR suitable for 62.5 KVA to 250KVA DG Set complete all as directed by Engineer-in- Charge. Make as per site requirement.
Supply and fixing in replacement of self starter 12 V suitable for 63 KVA to 160 KVA DG set complete all as specified and directed by Engr-in-charge.
Supply in replacement of rubber coupling nut bolt & washers of DG capacity 30 KVA to 62.5 KVA complete and alignment of DG set engine with alternator complete all as specified and directed by Engr-in-charge. Note : Cost T&P required for dismantaling of alternator and engine for replacement of rubber coupling will deemed to be included in quoted rate.
,---ditto--- all as per serial item No. 29 above but for 125 KVA to 250 KVA DG Sets complete all as specified and directed by Engr-in-charge..
Cleaning of radiator Assy, by cleaning fins and descaling complete including checking for leakage and repairing the leakage, soldering the broken tubes complete all as specified and directed by Engr-in-Charge.
Repair to alternator of DG set 30 KVA to 250KVA, servicing, greasing of alternator, cleaning the dust including replacement of defective rectifier of suitable capacity, testing complete of alternator for out put voltage and load etc complete all as specified and directed by Engr-in-charge.
M & L for repairing, welding doors to main body and making good for the canopy of DG set of any capacity including painting with existing colour after surface preparation complete all as specified and directed by Engineer in charge
Supply and fix in replacement of power contactor 100 Amp with fitting suitable for AMF panel 100 KVA including all necessary fittings complete all as specified and directed by Engineer in charge
Supply and fix in replacement of controller procom for auto main failure alongwith fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCCB 4 pole 160 Amps,25 KA, 415 Volts AC supply complete all as specified and directed by Engineer in charge
Supply and fix in replacement lubricant & oil sensor with fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement temperature sensor with fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement relay card with fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement relay 12 V with fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement battery charger 12 V with fittings complete all as specified and directed by Engineer in charge.
Supply and fix in replacement Current transformer ratio 100/5 alongwith with fittings complete all as specified and directed by Engineer in charge.
Supply only Engine oil 15W-40 confirming to CK 4 API category. Make : CASTROL
M&L wiring harness complete suitable for auto main failure 100 KVA complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement MCCB, 63 Amps, 4 pole, 415 Volts, rupturing capacity not less than 10 KA, Icu=100% with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Supply and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA, Icu=100% with built in protection function for overload, short circuit and double break fast tripping mechanism complete withspreader link including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 25mm X 4mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work in any type of soil and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in (1 : 2 : 4 ) type B1 with 3 Nos 6 mm dia MS bars both ways complete all as specified & directed by Engineer-in-Charge.
Taking down carefully old U/S LT Distribution Panels by dismantling the foundation and opening the cable connections, glands etc complete all as specified and directed by Engr-In-Charge
Taking down carefully old U/S MCCBs ofany size and Capacity by opening the cable connections, glands etc complete all as specified and directed by Engr-In-Charge
Taking down carefully old U/S LT UG Cables of any size and Capacity by opening the cable connections, glands etc complete all as specified and directed by Engr-In-Charge Note : Rates quoted by the contrcator shall be included the cost of excavation and earth work required to retrieve the old U/S Cable
Supply and fix in repair to replacement MCCB 100 Amps, 4 pole, 25 KA thermal and magnetic release in V TPN DB complete all as specified and directed by Engr-In-Charge.
Supply and fix in repair to replacement MCCB 160 Amps, 4 pole, 25/36 KA thermal and magnetic release in V TPN DB complete all as specified and directed by Engr-In-Charge.
Supply and fix in repair to replacement MCCB 250 Amps, 4 pole, 25/36 KA thermal and magnetic release in V TPN DB complete all as specified and directed by Engr-In-Charge.
Earthing for poles & other machinary/equipment using 4 mm GI wire as earthing lead and MS galvanised plate of size 60 cm x 60 cm x 6 mm, as earth electrode complete all as specified anddirected by Engr-In-Charge
Supply and fixing medium grade galvanized pipe 25 mm dia with all fitting laid in trenches complete and all as specified and as directed.Make : Jaindal/ Tata/ Prakash Surya
Supply and fixing gun metal globe or gate vavle 25 mm dia with iron wheel head screwed both ends for GI pipe complete all as specified and directed by Engr-in-charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4.0 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4.0 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying, testing and commissioning cable XLPE insulated screened meter PVC bedded, galvanised steel strip armoured, electric power calbes (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2.0 core complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth complete all as specified and directed by Engr-in-Charge
Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed by Engr-in-Charge
Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed by Engr-in-Charge
M&L sand cushioning, with dry and clean fine locally available sand for underground cable 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all specified and directed by Engineer-in-Charge. Note : Punned thickness shall be considered for payment purpose.
M&L brick protection with sub class'B' brick laid flat across the cable complete all as specified and directed by Engr-in-Charge
Supply and fix earthing strip of size 32 mm x 6 mm made out of GI Complete all as specified and directed by Engr-In-Charge
Supply and fix cable jointing kit for 1100 volt grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for LT UG Cable of size 95 Sqmm X 3.5 Core complete all as specified and directed by Engr-In-Charge
Supply and fix cable jointing kit for 1100 volt grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for LT UG Cable of size 70 Sqmm X 3.5 Core complete all as specified and directed by Engr-In-Charge
Supply and fix cable jointing kit for 1100 volt grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for LT UG Cable of size 50 Sqmm X 3.5 Core complete all as specified and directed by Engr-In-Charge
Supply and fix cable jointing kit for 1100 volt grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for LT UG Cable of size 35 Sqmm X 3.5 Core complete all as specified and directed by Engr-In-Charge
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
DASHMESH ENTERPRISES
GURDEEP SINGH AND COMPANY
Aggarwal brothers and company
M/S VISHNU ENTERPRISES
HARSH CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .