Supply, Installation, Testing and Commissioning of S&T material in connection with:- Leftover work for Provision of intermediate block signaling (IBS) between Shambhupura - Gambhiri Road stations on the Nimach- Chittaurgarh double line section.
SnT_RTM_26_07_R_Signal
SnT_RTM_26_07_R_Signal
Open
9 Months
Chittorgarh, Rajasthan
₹0
₹2.1 L
15 May 2026
15 May 2026
25 May 2026
XS2-EI alteration items icw IBS at SMP & GRF station 5815600.00 Below/Pa
Item Breakup - XS1-NS Schedule
Indicative type Fuse base/ holder withcap,suitable to Numbers G type fuse of capacity0.63A -3.0A. (System, Rapid, Malnador RBCO make or similar) RATLAM DIVISION-S AND T/WESTERN RLY
Indicative typefusebase/holder of capacity 0.63 A -3.0 A(System, Rapid, Malnad or RBCOmake or similar)
Time Element Relay (Clock work type) AG timer Numbers Siemens Make (No RSSK30/0052)
PVC insulated Railway Signaling multi core Indoor Metre Cable 1 x 60 x 0.6mm dia conforming to IRS:76/89(Amd3) orlatest
PVC insulated Railway Signaling multi core Indoor Metre Cable 1 x 40 x 0.6 mm dia conforming to IRS:76/89(Amd3) orlatest.
PVC insulated Railway Signaling multicore Indoor Metre Cable 1 x 24 x 1 mm dia conforming to IRS:76/89(Amd3) or latest
PVC insulated Railway SignalingIndoor Single core Kilometre wire conforming toIRS 76/89(Amd3) or latest. Note: - Wire Colours shall be decided byengineer - in - Charge." (i)1 x0.6 mm
PVC insulated Railway SignalingIndoor Singlecore Kilometre wire conforming toIRS 76/89 (Amd3) or latest. Note: -Wire Colours shall be decided byengineer - in - Charge (ii)1 x 1 mm
Single core multi-strand wire 0.5sq.mm. (16 Kilometre conductor each dia.0.2mm), as per IRS76/89 (Amd3)
Flexible copperconductors cross section 1x6 Sq.mm.(85 conductoreach diameter 0.30 +/- 0.01) asper IS694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as perIRS(S)76/89.
Flexible copperconductors crosssection(1x16Sq.mm).101 Conductorseach diameter0.45 + 0.01 as per IS694/2010 with insulation thickness of1.2mm nominal conductor resistance1.127 Ohms/Km andtest parametersas per IRS(S) 76/89
Desk type Electronic MagnetoTelephone as per spec Numbers No IRS/TC-79/2000 or with latest amendments.
Medium Class G.I. Pipes to IS :1239(Pt.I)-2004 or Metre latest ; 100mm dia.( int. dia)3.65 mm+/- 10% thick with coupling. G.I.pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I.pipes.
Thermo shrink Universal Jointing kit for Quad Cable Numbers (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With latest Amd.
Automatic Media changeover ofModems working on Numbers redundant channels for data transmission onOFC/Quad/ microwave radio.
Modem for UFSBI ( for used with secondary media Numbers OFC/Quad)
ARA Terminal blocks with links made of PBT Spec Numbers No.IRS/75/2006(Rev - 2)with latest amendments and RDSODrg.No.SA-23741AAlt.4.
Cartridge fuse block made of PBT asperRDSO Drg Numbers No SA-23748 Alt 4 &Spec No IRSS 75/2006 with latestamendment. Fuse blockshall besuitable for round head type voltage fuses. This also includes supply of equivalent no of ND type Fuses of 2A capacity asper specification IRS S-78/92.
Special type Neutral linesmagnetically latched Numbers relayQL1, 24VDC,11F/4B.completewith plugboard,finger contact and connectors conforming to BRS 935 A.
10 Pair x 0.63 mm dia Polythene Insulated Metre Polythene Sheathed Jelly Filled Telephone Cable with Poly-AL Moisture Barrier; Spec.No. IRS : TC41/97 Amdt No.1 to 3. RATLAM DIVISION-S AND T/WESTERN RLY
Supply of DC-DC convertor modules24-40V5A Numbers RDSO/SPN/165/2012 (Ver3) with latest amendment.For carrying out alterations inExisting IPS.
Supply of DC-DC convertor modules24-32V5A Numbers RDSO/SPN/165/2012 (Ver3) with latest amendment.For carryingout alterations in Existing IPS.
Supply of Fiber glass reinforcedplastic Plates of size Numbers 530x960x10 mmas per instruction of Engineer incharge.
Supply of 19" 9U Rack as per technical specification Numbers and instructions of engineering incharge
Supply of Permanently Lubricated(PLB) Highdensity Metre polyethylene(HDPE) Telecom duct foruse as underground cable conduits-40/33 mmas per RDSO specification No.RDSO/SPN/TC/45/2013Rev.2.0amnd 1& 2 or latest.
Supply of optical Patch cord cable(3Meterlong with Numbers connectors) as per RDSO specs no.RDSO/SPN/TC/69/2007or latest.
Supply of optical branching card for STM- Numbers 1(XA14ET)with SFP modules compatible with existing network and instruction of engineering incharge Total 1703089.00 Item- 2 B-1 Signal Execution Items S No. Item Description of Item Unit Qty Rate Amount No
Preparation of following completion plan on Per Route standard 75 micron polyester film all drawing will be prepared on CAD & one DVD/CD willbe providedfor the finally corrected versionofdrawing & documents after it ischecked &approved by Rlys.Completion documents willalsosupplied for ST/LT, WD etc. 6 copieswillalso be provided for each of thedocumentsmention below cable Routeplan includingdepth of cable , cablecore chart, location details, plan for alllocation and 20 copies of SWR plans,SWR literature and other literature required for commissioning.
Installation of Relay Rack AssemblyincludingIDF Numbers pillars if any completewith wall supports,scaffolding,ladders, runway for cables, fixingofRelay / Relay group base plates, fixing of Tag blocks etc. The work shall bedone as perapproved plan, extant practice on WR & the instructions of Rly engineer at site.
Installation of Cable TerminationRacksAssembly Numbers complete includingwall supports,scaffolding, 8 way/ARAterminals /Screw lessconnectors, Tagblocks & other necessary accessoriesetc. The work shall be done as pe rapproved plan, extant practice onWR & the instruction of Rly engineer atsite.
Installation wiring testing andcommissioning of Fuse Per Unit change oversystem (FACS). This includes provisionof common Buzzer &indication at ASMRoom & ESM Duty Roomand paintingof fuse details. This also includesfabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible.
Supply & installation of Test board(LED, Pintool Numbers type) for relay Room asper as per DrgNo RST/C/105 A&B RATLAM DIVISION-S AND T/WESTERN RLY
Circuit wiring/jumpering as percircuitdiagrams in the Numbers relay racks/IDFrack tag blocks. This includespreparation of Jumpersheets by wireman duly checked by firm'ssitesupervisor & wire to wire testing aspercircuit diagram. Any wrong jumperdone bywireman will not be paid &correction shall bedone free of cost.Jumper wires will be issuedbyRailways. Good quality solder resincore tobe supplied by contractor forsoldering ofJumper wires. Soldering ofjumper wires to bedone aftercompletion of testing by Railways.
Installations, wiring, testing and commissioning of Set RemoteT erminal Unit complete along with accessories using Contractor's ownwiring & fixing materials. (Itincludesloading of NETWORKING software and networking with data logger The requisite communication cable/channel for networking will be arranged by Railway.
Installation, Wiring and testing ofIntegratedPower Numbers Supply System. Thisincludes powerdistribution connectionto bus bars and relayracks in theroom with contractor's ownwiringmaterials and fabrication andfixing of AC/DCpower distributionboard made on 10mm thickPhenolichylam sheets or any standardmakewith connections suitable for 32A. Wiring tobe done considering siterequirement,depending upon the loadwith suitable wires,lugs & glands asper instructions of Engineer-incharge. The work includes installationofThermo flasher relay, ELD's, fixing &wiring ofchange over switch (programswitch) forselection of DG set supply(DG1 & DG2) andwiring of changeover switch (program switch)forselection of mains or DG supply. Thisitemalso includes supply & fixing ofladder alongthe wall for carryingpower supplywires/cables from IPSroom to Relayroom/power room etc.Any masonry workrequired will becarried out by contactorsown material." (ii)For LC gate/IBS
Supply laying & fixing of Anti StaticvinylFlooring Sqm with black conductivelayersandwiched between twoantistatic layer thickness of 2mm ±01mm self fire extinguishing as apperoved by engineer incharge
Excavation and Casting of foundationfor mainsignal Numbers post as per CSTE/3122(WR) withcontractor's own materialsincluding cementand anchor bolts of standard size. Therequired scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.
Erection of CLS Post with base and signal uniton top Numbers or on OFF set Bracket, fixing of front and back staging, ladder and guards,signalname plates / boards if any withcontractor'sown brackets and fixingmaterials. This alsoincludes erectionof auxiliary signals likecalling on,shunt signal if any. The work shallbedone as per instructions of Rlyengineer atsite. It also includesprovision & fixing ofmaintenanceplatform as per design givenbyEngineer -In-Charge at site. The Item includes cutting of Signal post ifrequired bySite In charge. (ii)2/3/4 aspect signal unit mounted mounted directly on signal post.
Fabrication and fixing of SignalNumber Plate(CSTE Numbers Drg NoCSTE/6186) , 'A' Marker (Drg No.CSTE/6180), 'AG' Marker (DrgNo.CSTE/6181), 'P' Marker (Drg No.CSTE/6182),Arrow Marker (Drg No.CSTE/6183), 'G'Marker (Drg No.CSTE/6184), 'C' Marker (DrgNo.CSTE/6185). marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor. RATLAM DIVISION-S AND T/WESTERN RLY
Supply & Fixing of Protective screenof expanded Numbers metal 12 SWG of Size1200 X 1500mm on Signaling as per standard practice for protecting against voltage in AC Traction area as per instruction of Engineer In Charge.
Excavation and Casting of Apparatus Case Numbers foundation with contractor's ownmaterialsincluding cement and anchorbolts of standardsize. The requiredscaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.(i)Single Case as per Drg No SK 748 or CSTE/5074
Excavation and Casting of Apparatus Case Numbers foundation with contractor's own materials including cement and anchorbolts of standardsize. The requiredscaffolding Ferma etc for Casting offoundation will have to be brought by the contractor at his own cost.(ii)Half Case as per Drg No SK 747orCSTE/5074 or SS Location
Installation of Apparatus Cases withminiature'E' Numbers type lock on CCfoundation. This includesfilling oflocation foundations with riverbedsand and plastering on top of thesand. 'E'Type lock will be provided byRailway. (i)Single Case
Installation of Apparatus Cases withminiature'E' Numbers type lock on CCfoundation. This includesfilling oflocation foundations with riverbedsand and plastering on top of thesand. 'E'Type lock will be provided byRailway. (ii)HalfCase
Excavation of cable trench as percable routeplan,1 cum Mtr. deep and of 0.3Mtr. to 0.6 Mtrswide advised byEngineer-in-charge alongsidethe trackin normal (all type)soil/strata,conforming to distances asper cable routeplan and refilling. Thiswork includes clearingof route frombushes etc, covering of cablelaid intrench by loose soil for a layerof50mm thickness approximatelybeforecovering by bricks. The workshall be done asper the extantpractice on Western Railwayandinstructions of Railway Engineer atsite.In case 1m depth of trench is notachievabledue to site conditions,specific approval of JAgrade officerwill be required for each sitewheretrench depth of 1m is not possible.Without the approval of JAG rade officer, no payment for trenching will be made fortrench depth less than 1m.
Digging of cable trench 0.3 Mtrs.Deep and0.3 Mtrs. cum Wide on AsphaltedPlatform / Road /Hard rocky area.Refilling with earth leveling of trenches & restoring the original surface of trenches.
Placing of DWC/RCC/GI pipes along with collars in Metre trenches at places oftrack and road crossings, plat form cuttings etc.
Fixing of GI pipes for crossing theculverts,bridges Metre etc. and concreting of ends with brick masonry at bothends as per the instructionof Rly engineer at site.
Supply & fixing of GI troughing &Channel ongirder Metre bridges for carryingcables. Fixing ofchannel with Girder tobe done with hook/ 'J'bolts of suitablesize to held the load of thetroughingas per Drg. No. CSTE/3004andCSTE/3006. This item alsoincludes the fillingone layer ofBitumen compound as per extant practice. (ii)Supply and fixing ofGI troughingof size 150mm x 200 mmx 2000mm RATLAM DIVISION-S AND T/WESTERN RLY
Laying of S&T Cables of various cores/pairs/quads in Metre trenches/ GI pipes/ RCCpipes/ DWCpipes/ Trunking. This alsoincludes laying ofcables in trackcrossings & road crossings.Itemincludes provision of labels ofcolouredplastic adhesive tapes or anyotheridentifiable material on eachcable to give thecable number ateach G.P.(Cables will bemaggeredbefore and after its layingbycontractor under supervision ofRailwayRepresentative and he willsubmit themaggering report of eachtesting). Length ofthe cable laidincludes the length of the cable coiled for termination purposes.
Supply and installation of RCC cableroutemarker Numbers engraved and painted onboth sidealong the route every 50 Mand routediversion as per Drg. No4014/00/CC4 or latest/ Stone marker.
Digging of cable pit (min 2x2x1m) asperinstruction Numbers of Site Engineer,supplying andfilling of sand beforeand after coiling thecables, coveringtop of the cable pit withstones andproviding brick masonry on all foursides of the cable pit and plastering thereafter.
Providing brick masonry in ratio 1:6cementand cum mortar includingplastering with 1:4cement and sandmixture both sides, 20 mmthick eachwith contractor's owned class II bricks,including excavation, curing,grouting,bolting etc. wherever required. Bricks sand and cement tobe supplied by the contractor.
Earthwork in filling in embankment,guidebunds, cum around buried typeabutments, bridgegaps, trolleyrefuges, rain bunds ifprovided,platforms etc. with earthexcavated fromoutside railwayboundary entirely arranged bythecontractor at his own cost as perRDSO'slatest guidelines andspecifications and specialcondition ofcontract including all leads,royalty,lifts, ascents, descents, crossingofnallahs or any other obstructions.The ratesshall include all dressing ofbank to finalprofile, demarcation andsetting out of profile,site clearance,removing of shrubs, rootsofvegetations growth, heavy grass,benching ofexisting slope of old bank,all handling/re-handling. Taxes, Octroiand royalty etc. as acomplete job. Cuttrees shall be property of railways andto be deposited in the railway godown unless specified otherwise in theSpecial conditions of contract.
Painting of two coats of syntheticenamelpaint over Numbers one coat of primeron the followingafter scraping &cleaning surface wherevernecessarywith contractor's own supply ofpaints.Wherever required contractorshallapply coating of epoxy paint alsoas perinstructions of site-in-charge.Epoxy paint willbe supplied byRailways. NOTE:- The paintand primershould be from Asian Paints/Nerolac /Dulux / Berger. The primer /enamelpaints (Aluminum synthetic,black enamel,brilliant white and yellow) will be as per (IS5660 of1970) / (IS 2932 of 1974)." (i)Apparatus Case Full Size. (Outside& inside)
Painting of two coats of syntheticenamelpaint over Numbers one coat of primeron the followingafter scraping &cleaning surface wherevernecessarywith contractor's own supply ofpaints.Wherever required contractorshallapply coating of epoxy paint alsoas perinstructions of site-in-charge.Epoxy paint willbe supplied byRailways. NOTE:- The paintand primershould be from Asian Paints/Nerolac /Dulux / Berger. The primer /enamelpaints (Aluminum synthetic,black enamel,brilliant white andyellow) will be as per (IS5660 of1970) / (IS 2932 of 1974)." (ii)Apparatus case Half Size. (Outside&inside) RATLAM DIVISION-S AND T/WESTERN RLY
Painting of two coats of syntheticenamelpaint over Numbers one coat of primeron the followingafter scraping &cleaning surface wherevernecessarywith contractor's own supply ofpaints.Wherever required contractorshallapply coating of epoxy paint alsoas perinstructions of site-in-charge.Epoxy paint willbe supplied byRailways. NOTE:- The paint Nerolac /Dulux / Berger. The primer /enamelpaints (Aluminum synthetic,black enamel,brilliant white andyellow) will be as per (IS5660 of1970) / (IS 2932 of 1974)." (iv)MainSignal Post with Signal Units,Surface baseand complete fittings asper Western Railways standard practice.
Painting of two coats of syntheticenamelpaint over Numbers one coat of primeron the followingafter scraping &cleaning surface wherevernecessarywith contractor's own supply ofpaints.Wherever required contractorshallapply coating of epoxy paint alsoas perinstructions of site-in-charge.Epoxy paint willbe supplied byRailways. NOTE:- The paintand primershould be from Asian Paints/Nerolac /Dulux / Berger. The primer /enamelpaints (Aluminum synthetic,black enamel,brilliant white andyellow) will be as per (IS5660 of1970) / (IS 2932 of 1974)." (vi)Track Lead Junction Box. (Black enamel outside only)
Lettering equipmentsnames etc., legiblyand neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac /Dulux/ Berger make. (i)Full Case.
Lettering equipmentsnames etc., legiblyand neatly insidelocation boxes. This includes supply ofpaints of Asian Paints/ Nerolac /Dulux/ Berger make. (ii)Half Case
Dismantling of Concretefoundation/Demolishing cum RCC/CC/Stonework /CuttingTarcarpenting/ CCFlooring/ Precast concreteslab/ Brickwork including leading thedebriesinside Railway limit or outside Railway limit as directed by site incharge. This work to bedone by contactors with his own vehicleand labour.
Dismantling & releasing of all typeofApparatus case Lumpsum including foundationcompleteand other accessories andtransporting themto consignee'sdepot or DS-8 depot as perthe instruction of Engineer In-chargeby contactors own vehicle & labour
Dismantling of all signals completewithsignal unit, Numbers route indicator, signalfoundationand other accessoriescomplete withtransporting them toconsignee's depot or DS-8 depot asper the instruction of Engineer Inchargeby contactors own vehicle & labour.
Dismantling of Track circuitequipmentsincluding Numbers track circuitcharger, battery choke ,resistance ,bonding wires, bootlegs andotheraccessories with transportingthem toconsignee's depot or DS-8depot as per theinstruction ofEngineer In-charge by contactors own vehicle & labour .
Installation of Maintenance free Earth Electrode for Numbers Maintenance freeearth spec of RDSO/SPN/197 ver 1.0
Installation of media change over as per instruction Pair of engineering incharge. RATLAM DIVISION-S AND T/WESTERN RLY
Installation testing & commissioningof Axle counter Set 4DP/3TS type systemor as provided and decided byrailways complete with track devicesandother associated accessories. Thisinclude fixing of device,relays, wiring,lacing/dressing,cabletermination withlug eyelet,drilling holes inrails,Installation of track devicesandmake it functional along withexistingUFSBI/block instrument.Material required other then supply item of DAC shall be arranged by contactor to make it functional.
Fixing of Q series relay baseplate/metaltometal Numbers relaymini groupand major groupbaseplate,laying,bunching, lacing,dressing&packeting of@10<47@40corePVCindoorcable/flexible wire andtermination of core of cable/flexiblewire ontagblock/base plate &baseplates &soldering.This includesfuse wiring, busbarloopingetc.required for keepinginstallationreadyforcircuit wiring work &panel throughing work. The work shall be doneas per approved plan, extantpractice onWR & the instruction of Rly. Engineer at site
Supply and installation of two wiretalk backsystem System consisting of onemaster unit and one slave unitsuitable for IBS, working voltage110 VAC as per sitein charge's instructions.
Detailed testing of wiring as per approved wiring Station diagram (W.D.) at stations,including one and two wire check, functional testing,section table & locking table testing with simulation panel including making panel through, In thepresence of railway officials. A copy of tested selection table,locking table and cross sheet duly signed by contractor to be submitted to field office for record. This item includes wiring of simulation panel for testing as per standard practice, with contractors own materials. Contractor will put sufficient staff to carryout the testing round the clock and will ensure that any alternations which may become necessary during testing are carried out and testing is repeated wherever required. This includes supply of lamps for simulation panel for testing.This also including extending various supplies upto bus bars in relay room, and up to battery room, providing manual bypass arrangement for automatic changeover arrangement and stabilizers,provision of Test Board for monitoring suppliesas per instructionof Engg.Incharge. All materials like nuts, bolts, fixtures etc required shall be supplied by Contractor.
Installation, fixing and wiring of LED signal lighting Numbers unit inside alltypesof Signal units. Italso includes complete wiring in signal unit and location boxes/ hut asper approved drawing and as per instruction of Engineer incharge.Note: LED Signal Unit will be suppliedby Railways. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, Fabrication & fixing of hylamsheetofsize Sqm 10mm thick (otherdimension i.e.lengthand breadthwillbe decided by Enggin-charge)forA/case NE type byprovidingallfixturesincluding fixing ofPVCcoatedString Rods atthe back sideforcable support withcontractorownmaterials.The item includes fixingofM6terminals orscrew less /fuseblocks /HRCfusesND typeon eachstrip. Two extra holes onbothsidesofM6 terminals or screw less/fuseblocks/HRC fuseand two extra holesforfixingthe sheet. Note: (i)Thecompletehylamsheet to be coveredwitheitherM6terminals or screw less/fuse blocks/ND type HRC fuses as perinstructions of engineer at site. (ii)Hylam sheet to be of grade P2. (iii) M6 terminals or screwless,HRC fuses willbe supplied by Railway.Theaboveitem also includes fixing of Qseries(GPR) relays.
Supply, fabrication and fixing of commercially Sqm available Compact water resistance Laminated Sheet 12mm thick for keeping S&T equipmentsas per the Instruction of Engineer incharge. This item includes supply and fabrication/ fixing of all materials like laminated sheet, Nuts and bolts,fixingarrangementsalongwithfabrication of tablesfor keepingequipmentsl ike reset box, Blockpanelandfabrication of Key boxand/ or anytype of box/ table box for keeping equipmentsetc. can also be got fabricated under this itema s perthe design given by engineer incharge.
Termination coresonARAterminal/fuseblocks, 8 wayterminalsblock/Screw-lessconnectorsin theapparatuscases/cable termination rackatbothends.Both ends of a cablecoreterminated shallbecounted as oneterminal.This includesallassociatedworks of pulling outthecable from underground. The itemincludes dressing of cables, makingwiring tree etc.The work shall be doneas perLocation plans andas per theinstruction of Engineerin- charge.
Provision of Earth connection toLoactionBoxes and Metre signals with MSFlat strip as per instruction ofengineering in-charge .Supplyof MSflat of size40X6mm at site whichincludes loading, unloading,transportation and fixing.
Installation of 9U rack with complete accessories as Numbers per instructions of Engineering in charge
Splicing of OFC cable and making thesplicejoint Numbers indust free environmentwithcontractor'sown equipment andlabour. Allrequired materials toolsplants shall bearranged by thecontractor splicing shall bestartedfrom one end and each splicing shallbemonitored after splicing and afterclosing theenclosure for all the fibersfrom one centrallocation bycontractor engineer with his ownOTDRand optic talk set with railwayengineertrace for the fibers shall betaken and signedjointly, if any fibredsplice shows highloss/lossy event thesame shall be redone before completion of splicing work.The splice loss shall be as per the policy/technical circular issued by the Railways from time to time.
Blowing of OFC through HDPE duct&protective work Metre where it is notfeasible toblowOFC due to curvesroad/trackcrossing bridgesor for anyother reason,OFC shall be draw/laidmanually as per standard procedure.Allthe equipments and machineryrequired shallbe arranged by thecontractor at his own cost.In case OFCis to be laid adopting'direct in trench method. RATLAM DIVISION-S AND T/WESTERN RLY
Laying of HDPE Pipe of size 40 mmwith protective Metre workas per instruction of Engineer in charge.
Installation of Axle counter cable conductor's Earth Numbers Resistance sensing unit
Supply, Microprocessorbased Networkable AnalogueAddressable upto 64 nodes 1Loop FireAlarmControl panel with LCD display,the panel should be equipped withsufficient nos.of loop as per RDSOSpecification No.RDSO/SPN/217/2025ver 3.1 or latest.Each loop shall havecapacity of 127 analogue addressabledevices in1loop,the panel shall havesufficient nos. of programmable relaycontrol for controlling AHU's,pressurisation fans,ventilation fans atfire pump room,monitoring of firesprinkler & sealed lead acid batteriessufficient for 24 Hours normal working& then capable of operating thesystem for 24 Hours duringEmergency conditions as required.The panel shall have provision ofconnectivity ofBACNET/MODBUS/LONWOK/TCP-IP.The panel shall have dedicated RS232serial port for direct PC or MODEMconnection,optional remote printer asper RDSO SpecificationNo.RDSO/SPN/217/2025 ver 3.1 orlatest.
Supply, installation andcommissioning of intelligent Numbers AnalogueAddressable Multi-Sensor type smokedetector with inbuilt fault isolator andintegral response indicator with 360degree viewing angle.Detector shallcommunicate 3 danger levels fordifferentiated alarm activation andhigh tolerance todust,dirt,temperature fluctuations andair current.Detector should haveunique address for communicationand assigned through panel withmounting base as required with theprotection category of IP40. All itemsas per RDSO Specification No.RDSO/SPN/ 217/ 2025 ver 3.1 or lates
Supply installation commissioning ofAnalogue Numbers Addressable Manual CallPoint with integral short circuitisolator, Analogue addressableprotocol having status LED foralarming & standbymode,Electronically addressed) asperRDSO Specification No.RDSO/SPN/217/2025 ver 3.1 or latest
Supply, installation, testing andcommissioning of Metre Linear Heat Sensing (LHS)cable as per RDSO Specification No.RDSO/ SPN/ 217/2025 ver 3.1 or latest
Supply, installation, testing and commissioning of Numbers LHS interface module as per RDSO Specification No.RDSO/SPN/217/2025 ver 3.1 orlatest.
Supply, installation, testing andcommissioning of Lot FRLSunarmoured/armouredcable(2Cx1.5sq.mm)with all accessories for connection of all Fire Alarm devices as per RDSOSpecification No. RDSO/SPN/217/2025 ver 3.1 or latest
Supply installation commissioning ofUV/IRType Numbers Flame detector withrequired module to communicateonmain fire alarm panel as perRDSOSpecification No. RDSO/SPN/217/2025 ver 3.1 or latest.
Supply, installation, testingand commissioning of Numbers Supply of AirSampling Type detector shall useLASER type. This type ofdetector shalluse piping or tubingdistributionnetwork thatshallrunfromthe detector to theareaas tobeprotected. Itshouldbesuppliedwithrequired module&Powersupplyunitcomplete as asystem with all accessories like pipes,Sampling point set as per RDSO Specification No.RDSO/SPN/217/2025 ver 3.1 or latest. RATLAM DIVISION-S AND T/WESTERN RLY
Supply, installation, testingandcommissioning of Numbers Supply ofintelligentAddressable Loop PoweredSounder cumbeacon with base inbuiltfault isolator with protection category of IP42 and duly approved as per RDSO Specification No.RDSO/SPN/217/ 2025 ver 3.1 or latest. Total 2838977.45 Item- 3 A-2 Telecom Supply Items S No. Item Description of Item Unit Qty Rate Amount No
Thermo shrink Universal Jointing kitfor QuadCable Numbers (for straight joints) asper RDSO specIRS/TC- 77/2012revision 3 With latest Amd.
Supply of one inch diameter PVC pipewithmedium Metre mechanical stressconforming toIS9537 Part-III.
Supply of 30 MBPS 2W/4W LANExtendersupporting Pair short and longdistance (upto10Kms or more) Dualpower supply AC/DCfrom a singlesocket plug inmodule in the stand alone unit.Make MROTEK,TEAMLINK,Cygnus,ANDA.
Supply of 24 Port LIU Rack Mountableloadedwith Numbers suitable connectors of Dlink,Molex,Raychem orAmpmake.TheContractorshouldsupply all miscellaneous items like connector patch cord for complete installation of Fixed optical fiber inter connection unit. Total 40269.46 Item- 4 B-2 Telecom Execution Items S No. Item Description of Item Unit Qty Rate Amount No
Excavation of cable trench as percable routeplan,1 cum Mtr. deep and of 0.3Mtr. to 0.6 Mtrswide advised byEngineer-in-charge alongsidethe trackin normal (all type)soil/strata,conforming to distances asper cable routeplan and refilling. Thiswork includes clearingof route frombushes etc, covering of cablelaid intrench by loose soil for a layerof50mm thickness approximatelybeforecovering by bricks. The workshall be done asper the extantpractice on Western Railwayandinstructions of Railway Engineer atsite.In case 1m depth of trench is notachievabledue to site conditions,specific approval of JAgrade officerwill be required for each sitewheretrench depth of 1m is notpossible.Without the approval of JAGrade officer, nopayment fortrenching will be made fortrenchdepth less than 1m.
Laying of S&T Cables of various cores/pairs/quads in Metre trenches/ GI pipes/ RCCpipes/ DWCpipes/ Trunking. This alsoincludes laying ofcables in trackcrossings & road crossings.Itemincludes provision of labels ofcolouredplastic adhesive tapes or anyotheridentifiable material on eachcable to give thecable number ateach G.P.(Cables will bemaggeredbefore and after its layingbycontractor under supervision ofRailwayRepresentative and he willsubmit themaggering report of eachtesting). Length ofthe cable laidincludes the length of the cable coiled for termination purposes.
Supply and installation of RCC cableroutemarker Numbers engraved and painted onboth side along the route every 50 Mand route diversion as per Drg. No4014/00/CC4 or latest/ Stone marker.
Laying of Telecom cable in PVCPipe,Casing Capping Metre & conduit Pipe as per Instruction of Engineer Incharge. RATLAM DIVISION-S AND T/WESTERN RLY
Labour assistance for SSE/JE in day to day works Man- i.e.,checking the curves/straight alignment of Days formation levels etc,. Carrying the tools & equipments etc,.Watch & ward during the course of execution of work as per the instructions of concerned SE/JE. Total 87854.41
Item Breakup - XS2-EI alteration items icw IBS at SMP & GRF station
Design and modification in existing EIas per Numbers approved Signalling plan. Thisworkincludes all indoor and outdoorwork necessary software andhardware to carrying out alteration/modification and also carry out FATand SAT test ( If required). This alsoincludes modification to all existingdrawings provided with Electronicinterlockingand preparation/alteration of Logic diagram, Interfacediagram, VDU diagram.Square sheet,I/F wiring chart and selection tableetc. and other inter connectiondrawings with Relay room, equipmentroom etc. on the basis of approvedsignalling plan like typical circuitdiagram, fuse analysis chart, terminalanalysis and contact analysischartetc. as per Railway practice andobtaining approval ofcompetentauthority for EI.Design andsupply foradditional altration andmodification in Electronic interlockingsystem of Ansald omake at GambhiriRoad station and Medha make atShambupura station. Existing EI is Ansaldo make at Gambhiri Road station and Medha make at Shambupura station. Total 5815600.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
revisedTANearthingHQletter040725_compressed.pdf Latest Earth TAN
ATTACHMENT
TenderdocumentGRF-SMPIBS1.pdf
ATTACHMENT
AppendixGRF-SMPIBS2.pdf
ATTACHMENT
ACS-2toGCC-2022.pdf
ATTACHMENT
GCCApril2022ACSNo_3_1.pdf
ATTACHMENT
GCCApril2022ACSNo_4.pdf
ATTACHMENT
GCCApril2022ACSNo_5.pdf
ATTACHMENT
GCCApril2022ACSNo_6.pdf
ATTACHMENT
GCCApril2022ACSNo_8.pdf
ATTACHMENT
GCCApril2022ACSNo_9.pdf
ATTACHMENT
GCCApril2022ACSNo_7.pdf
ATTACHMENT
GCCApril2022ACSNo_10.pdf
ATTACHMENT
GCCApril2022ACSNo_11.pdf
ATTACHMENT
ApprovedSIPofGRFicwSMP-GRFIBS.pdf
ATTACHMENT
ApprovedSIPofSMPicwSMP-GRFIBS.pdf
ATTACHMENT
revisedTANearthingHQletter040725_compressed.pdf
ATTACHMENT
Download all tender documents and submit your bid