Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.9 L+₹8.2 L (21.6%)Rejected-Finance | L2 | Rejected-Finance Being L 2 | |
| 3 | L3₹46.7 L+₹8.9 L (23.6%)Rejected-Finance | L3 | Rejected-Finance Being L 3 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
10 Nov 2021, 6:00 pmClosed
GE (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
REPAIR / MAINTENANCE OF LT UG CABLE / LT OH LINES, REPAIR / REPLACEMENT OF CORRODED GI / CI DISTRIBUTION PIPE LINES AND OTHER ALLIED WORKS AT VARANASI CANTT UNDER GE(EAST) ALLAHABAD.
2021_MES_480120_1
8507/E8
Open Tender
Civil Works
Item Rate
180 days
Varanasi
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹97,000
Yes
8 Jan 2022
6 Oct 2021
13 Nov 2021
6 Oct 2021
10 Nov 2021
26 Oct 2021
6 Oct 2021 - 13 Oct 2021
Amount
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5metre in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft / loose soil, complete all as specified and directed.
Returning, filling in, in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm., complete all as specified and directed.
Removing surplus excavated soils to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Spreading of natural, clean and dry river sand in trenches for cable protection, complete all as specified and directed. NOTE:- Punned thickness shall only be measured and paid.
Supply and lay burnt clay fly ash bricks class 'B', old size, designation 75, size 230mm x 115mm x 75mm, laid in trenches for cable protection with length of brick equal to width of trench, complete all as specified and directed.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls / ceilings or laid in floors / laid in ducts / laid under road crossing for cables, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 80mm bore of pipe including taking down old and unserviceable pipe, complete all as specified and directed. NOTE:- Necessary excavation and earthwork for taking down old and unserviceable GI pipe shall be measured and paid separately under respective items of this Schedule. MAKE:- TATA / Jindal / Zenith / Prakash Surya / Swastik
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls / ceilings or laid in floors / laid in ducts / laid under road crossing for cables, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 50mm bore of pipe including taking down old and unserviceable pipe, complete all as specified and directed. NOTE:- Necessary excavation and earthwork for taking down old and unserviceable GI pipe shall be measured and paid separately under respective items of this Schedule. MAKE:- TATA / Jindal / Zenith / Prakash Surya / Swastik
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 240 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 120 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 95 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 70 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 50 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 35 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volt grade, ISI marked as per IS-7098, cross-sectional area 25 sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, including taking down existing old and unserviceable cable in any position, complete all as specified and directed. NOTE:- Excavation and earthwork, sand cushioning and brick cable protection shall be measured and paid separately under respective items of this Schedule.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling existing cross arms, complete all as specified and directed.
Preparation of steel and iron based surfaces of any description (the surfaces are of indoor / outdoor panel of any size / type) including removing dust / dirt by cleaning / scrubbing as required, including welding / fixing, provision of new hinges, scres, nuts, bolts and washers as required, painting the outer surfaces of panel with one coat of synthetic enamel paint without disturbing existing fittings and fixtures, including wiriting letters such as SM No., capacity with safety precautions etc., complete all as specified and directed.
Supplying and laying synthetic Rubber insulated mats, ISI marked, 19 mm thick for voltage upto 33 kV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes, 2000mm x 1000mm, including taking down old and unserviceable matting of any size and thickness, complete all as specified and directed.
Restringing of existing OH lines of ACSR conductor and earthwire of any size inlcuding opening from insulators, tightening upto permissible sag, binding properly and refixing of cradles with safety precautions, complete all as specified and directed. NOTE:- (a) Each row of ACSR conductors and earthwire shall be measured and paid as one unit. (b) Approximate length of each span shall be 30-35 metre
Preparation of external surfaces of steel tubular street light poles of 9.00metre long including cross arms, clamps of any lenght and shape and painting externally complete pole portion with two coat of aluminium paint over a coat of red oxide primer, painting of three black & two yellow strips of 100mm width each externally from ground level upto 1.5m including writing of pole number in a 150mm dia yellow circle with fluorescent paint and painting of coping surfaces with three coat of white wash, complete all as specified and directed.
MCCB 3 pole 415V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 25 kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
ACB 4 pole 415V, 630 Amps, 50 Hz with thermal magnetic release (manual draw-out type) with rupturing capacity 50 kA, fixed in repairs, complete all as specified and directed. MAKE:-: Legrand / L&T / ABB / Schneider
MCCB 4 pole 415V, 400 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 50 kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
MCCB 4 pole 415V, 250 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 35 kA / 36kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
MCCB 4 pole 415V, 200 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 35 kA / 36kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
MCCB 4 pole 415V, 160 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 35 kA / 36kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
MCCB 3 pole 415V, 160 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 35 kA / 36kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
MCCB 4 pole 415V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 25 kA, adjustable overload min 70-100%, fixed in repairs, complete all as specified and directed. MAKE:-: ABB (T-Max) / Siemens(3VT) / L&T(D-Sine) / Legrand(DPX) or techno-commercially equivalent model in Schneider.
Stringing of Aluminium conductor, steel reinforced (ACSR) of required size for overhead lines on LT poles with and including provision of suitable size of copper binding wires, complete all as specified and directed. NOTE:- (a) Copper binding wire shall not be included in the weight of conductors. (b) Weight of ACSR or all aluminium conductors drawn for overhead lines shall be determined by measuring that horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc. (c) Weight of conductors shall be calculated from the tables given in the relevant I.S. Where the weight of any conductor is not given in the I.S, it shall be calculated using standard tables of the electrical conductors supplied by the makers.
Stringing of Galvanised steel wire 3.15mm dia as earth conductor on LT poles with and including provision of suitable size of copper binding wires, complete all as specified and directed.
Cutting of existing bituminous road or PCC hardstanding upto 1200mm deep and 250mm wide and getting out for laying of under ground pipe line (80/50mm dia), including returning, filling in layers not exceeding 25cm thick, including making good of the top surface upto 150mm depth to match with the existing using PCC 1:2:4 type B1 (20mm graded stone aggregate), complete all as specified and directed. NOTE:- GI pipe light grade 80mm / 50mm dia shall be measured and paid under respective items of this Schedule.
Bus bar box of sheet metal 2mm thick having 4 Nos aluminium bus bar of 200 Amp rating mounted on insulator, with and including provision of MCCB 4-pole 415 Volt 100Amp with thermal magnetic release, rupturing capacity 25kA - 01 No provided inside the box, providing suitable fixing arrangement using FI clamps of size 25mm x 3mm with hinged cover and locking arrangment including painting with two coat of synthetic enamel over a coat of red oxide primer after preparation of surfaces, fixed in repairs, fixed on poles / walls, complete all as specified and directed. MAKE:- Havells / C&S / L&T
Steel tubular swaged poles type 410 SP 31 (Overall length 9.00 metre) complete with cast iron base plate, finial taper plug, with necessary bolts, nuts and washers screws, pole shall be painted with two coat of black bituminous paint throughout internally and externally upto planting depth (i.e., embedded portion in ground / concrete) and the remaining external complete pole portion shall be painted two coat of aluminium paint over a coat of red oxide primer, painting of black & yellow alternate strips of 30cm each externally from ground level upto 1.5m with synthetic enamel paint, including writing of letters or figures (block, roman, italic or Indian) with thick synthetic enamel paint of approved tint not exceeding 5cm height including numbering of poles, complete all as specified and directed. NOTE:- Excavation in trenches, PCC in bed concrete, foundation and coping shall be measured and paid separately under respective items of this Schedule. MAKE:- National tubing Co., Kanpur / BCW Kanpur / M/s Sohan Lal & Sons / United Engineers, Kanpur
Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps 31mm x 3mm, 18mm dia GI nuts, washers, insulator bolts, washers and nuts, 75mm height & 90mm dia suitable for 1100 Volt grade including taking down old and unservicebale one, complete all as specified and directed.
Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 65mm height, 100mm dia for 1100 Volt grade, including taking down old and unserviceable one, complete all as specified and directed.
Change over swirtches panel mounted off-load type in open execution, front operated rotary handle of 200 Amp rating, 4-pole, 415 Volt, including taking down old and unserviceable one, complete all as specified and directed.
Change over swirtches panel mounted off-load type in open execution, front operated rotary handle of 400 Amp rating, 4-pole, 415 Volt, including taking down old and unserviceable one, complete all as specified and directed.
Change over swirtches panel mounted off-load type in open execution, front operated rotary handle of 63 Amp rating, 4-pole, 415 Volt, including taking down old and unserviceable one, complete all as specified and directed.
Change over swirtches panel mounted off-load type in open execution, front operated rotary handle of 100 Amp rating, 4-pole, 415 Volt, including taking down old and unserviceable one, complete all as specified and directed.
PVC junction box of size 230mm x 170 mm x105 mm with four Nos Aluminium bus bar of rating 100 Amp, mounted on and including provision of heavy duty insulators, shockproof, rustproof and termite resistant cable entry from bottom and other sides,100% weatherproof, with pole mounting arrengement tamperproof, suitable fire retardant class FV-0 as per IS 11731 part -II or V-O as per UL-94 including provision of flexible twin core copper cable PVC insulated 2.5 sq.mm from junction box to light fittings and fixed with and including provision of flat iron clamp of size 25mm x 3mm, complete all as specified and directed. MAKE:- SINTEX / NAITHANI PLASTIC WORKS / SUPREME INDUSTRIES
Supplying, installation, testing and commissioning of factory made cubical outdoor (kiosk) type feeder pillar box 415 Volt, 4-wire, AC 50 Hz, of size 1000mm x 750mm x 600mm, made out of 3.15mm thick CRCA sheet, weather and vermin proof powder coating finish both interior and exterior side, for outdoor mouting with having degree of protection as per IP-65 with locking arrangements, two earth terminal suitable cable gland for incoming and outgoing and removable neutral link, connecting strip / solid coductor brought out to cable chamber brass / copper nut, bolts, washers etc., including grouting of feeder pillar box 600mm above ground level including provision of suible size angle iron stand made up of 65mm x 65mm x 6mm welded on all the four corner embedded in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) upto 300mm above ground by providing 900mm long ISA 50mm x 50mm x 6mm, complete all as specified and directed with and including provision of the following:-
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for cable end terminatiion heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sq.mm to 50 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for cable end terminatiion heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sq.mm to 95 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for cable end terminatiion heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 120 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, jointing and testing of Cable jointing kit for 1100V grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 300 sq.mm., fixed in repairs, complete all as specified and directed. MAKE:- 3M LTD / DENSON / RAYCHEM / M-SEAL
Supplying, installation, testing and commissioning of factory made cubical outdoor (kiosk) type feeder pillar box 415 Volt, 4-wire, AC 50 Hz, of size 900mm x 750mm x 600mm, made out of 3.15mm thick CRCA sheet, weather and vermin proof powder coating finish both interior and exterior side, for outdoor mouting with having degree of protection as per IP-65 with locking arrangements, two earth terminal suitable cable gland for incoming and outgoing and removable neutral link, connecting strip / solid coductor brought out to cable chamber brass / copper nut, bolts, washers etc., including grouting of feeder pillar box 600mm above ground level including provision of suible size angle iron stand made up of 65mm x 65mm x 6mm welded on all the four corner embedded in PCC 1:2:4 type B1 (using 20mm graded stone aggregate) upto 300mm above ground by providing 900mm long ISA 50mm x 50mm x 6mm, complete all as specified and directed with and including provision of the following:-
Providing pre-cast cement concrete 1:2:4 type B1 (20mm graded stone aggregate) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, complete all as specified and directed.
Earthing with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of 25mm x 4mm size by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'light grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber, 40mm thick precast RCC cover (1:2:4) type B1 mix with 6mm dia nominal reinforcement @ 100mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. NOTE:- Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor and protection pipe beyond 7.5metre shall be measured and paid under respective item of this Schedule.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25mm x 4mm galvanised iron strip, complete all as specified and directed.
Steel tubing, light grade, ISI marked, galvanised including short lengths, laid in trenches / fixed to walls / ceilings or laid in floors / laid in ducts / laid under road crossing for cables, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 40mm bore of pipe, complete all as specified and directed. MAKE:- TATA / Jindal / Zenith / Prakash Surya / Swastik
Hardcore of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft / loose soil, complete all as specified and directed.
Loop type insulator, vitreous porcelain, white, brown or green, large size, with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, complete all as specified and directed.
Galvanised stay strand, 7 / 4mm, complete all as specified and directed.
Stay assembly, using 20mm dia stay rod, complete with accessories as shown in electrical plate No. 1, complete all as specified and directed. NOTE:- Loop type insulator, stay clamps, excavation and concrete etc., shall be measured and paid separately under resepctive items of this Schedule.
LT spacer spiral type including fixing on existing over head lines to maintain the required distance, complete all as specified and directed.
Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole, complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 200mm x 150mm size, oomplete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 250mm x 200mm size, oomplete all as specified and directed.
Supplying and fixing 1100 Volt grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 4sq.mm cross-sectional area, complete all as specified and directed.
Supplying and fixing 1100 Volt grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 6sq.mm cross-sectional area, complete all as specified and directed.
Supplying and fixing 1100 Volt grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of 10sq.mm cross-sectional area, complete all as specified and directed.
Taking electric shutdown and employing labour competent to climb on trees for maintenance and trimming of tree branches touching to overhead bare electric condutor lines / electric installation upto the clearance of 2 metre all-around and removing the garbage and deposting where directed, complete all as specified and directed. NOTE:- The quoted rate shall deemed to be inclusive for deploying 8 Nos of (Minimum) labours along with proper safety kit and cuttings tools, ladder, electric saw / generator set, wire rope etc., by the contractor and nothing extra what-so-ever shall be admissible on this account at any stage.
Supply, lay, jointing and testing of DI pipes with spigot and socket ends centrifugally cast type, class K-9 pressure pipe for water supply, ISI marked suitable for ring tyton joint in any length laid in trenches in proper alignment of following sizes, complete all as specified and directed.
80 mm bore
100 mm bore
150 mm bore
DI fittings bends (any type of radius and angle), tapers, any type of straight bends, increasing/ decreasing or double socket etc, tees, pieces, single branch, Y junctions, doublebranch, cross (all sockets or socket and spigot), collars, caps and plugs upto 150 mm bore pipe, complete all as specified and directed.
Taking down unserviceable CI / DI water mains including all necessary fittings from trenches of the following sizes, complete all as specified and directed.
80 mm bore
100 mm bore
150 mm bore
Steel tubing, medium grade, ISI marked, galvanised including short lengths, laid in trenches, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), of the following sizes, complete all as specified and directed. MAKE:- TATA / Jindal / Zenith / Prakash Surya / Swastik
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Steel tubing, medium grade, ISI marked, galvanised including short lengths, fixed to walls / ceilings or laid in floors / laid in ducts / laid under road crossing for cables, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), of the following sizes, complete all as specified and directed. MAKE:- TATA / Jindal / Zenith / Prakash Surya / Swastik
20 mm bore
25 mm bore
Taking down unserviceable GI water tubings, including all necessary fittings from trenches or walls / floors of the following sizes, complete all as specified and directed.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, for following sizes, fixed in repairs, complete all as specified and directed.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Sluice valve of pressure rating PN 1.6 with stainless steel rod / spindle and check nut of following sizes, complete all as specified and directed MAKE:- Kirloskar / Leader / Kejriwal / Upadhyay / BIR
80 mm bore
100 mm bore
150 mm bore
Taking LT shutdown, dismantling and removing the motor of the coupled pump set from existing foundation / any position, shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator slots, rewinding the motor with super enamelled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying, etc, replacing the bearing, reassembling and installing back at its original position, aligning, testing and commisioning on full load for 8 hours continuous running for the 10 HP, 3 phase elctric motor, complete all as specified and directed.
Taking LT shutdown, dismantling and removing the motor of the coupled pump set from existing foundation / any position, shifting to authorized workshop for the repair work, removing the burnt winding, cleaning rotor / stator slots, rewinding the motor with super enamelled copper wire of the size equivalent to the original winding including insulated packing materials, varnishing, heating, drying, etc, replacing the bearing, reassembling and installing back at its original position, aligning, testing and commisioning on full load for 8 hours continuous running for the 20 HP, 3 phase elctric motor, complete all as specified and directed.
Taking out old unserviceable online pressure pump and repair and refixing fully automatic online pressure pump complete with replacement of pressure gauge and storage tank and all accessories and testing, complete all as specified and directed.
PVC insulated multi stranded copper conductor submersible cable, 1100 Volts grade, ISI marked of size 6 sq.mm, 3 core, complete all as specified and directed.
Digital submersible motor starter DOL type suitable for 3 phase, 10 HP, alongwith all connected accessories PLC relay, single phase preventor, dry run protection enclosed in and including box of make:- L&T / SEIMENS or techno-commercially equivalent make and making electric connection, complete all as specified and directed.
Single phase 220 V DOL starter suitable for 1.5/2 HP pumpset with overload and short circuit protection, fixed in repair, complete all as specified and directed. MAKE:- Schneider / L&T
Mechanical joint to existing CI pipes, fixed in repair, complete with rubber ring nut / bolts and washers, complete all as specified and directed, of following sizes :-
80 mm bore
100 mm bore
150 mm bore
Supply only water disinfectant containing 60 to 70% chlorine content (Calcium based granular disinfectant for water treatment, packed in 45 kilogram plastic drums), complete all as specified and directed. MAKE:- Aquafit / Chloropure
Ring tyton joint including rubber ring for DI / CI pipes of following sizes, complete all as specified and directed :-
80 mm bore
100 mm bore
150 mm bore
Excavation in trenches in soft/ loose soil upto a depth not exceeding 1.0 metre along the CI pipe line of dia 80 to 200 mm dia between leaking area, burning out the leakage joint and jointing with spun yarn and lead complete and refixing the same with proper lead joint and lead wool including necessary returning, filling in and well ramming in layers not exceeding 25cm each, complete all as specified and directed.
Excavation in trenches in soft / loose soil upto a depth notexceeding 1.0 metre along the CI / DI / GI pipe line of dia 50 to 150 mm (main line between leaking area and taking out old unserviceable MS clamp and jointing properly with new clamps of same size and type including provision of nuts, bolts and rubber packing including necessary returning, filling in and well ramming in layers not exceeding 25cm each, complete all as specified and directed.
Cutting of existing bituminous road or PCC hardstanding upto 900mm deep and 500mm wide and getting out for laying of under ground pipe line any dia as required at site, including returning, filling in and well ramming in layers not exceeding 25cm each, including making good of the top surface upto 150mm depth to match with the existing using PCC 1:2:4 type B1 (20mm graded stone aggregate), complete all as specified and directed.
Construction of brick masonry valve pit of size 1050 mm x 1050 mm x 1050 mm (internal dimensions of chamber) (depth shall be reckoned from the top of PCC in foundation to top of MS cover) with MS sheet cover 3mm thick including frame of angle iron 40 mm x 40 mm x 6 mm with locking arrangement with pad lock of size 50 mm brass, 6 levers and key (Make : GODREJ) and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc., including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 150mm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 metre, 15 cm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in PCC foundation projected by 150mm all round from the outer face of brick wall, PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in coping including dismantling old/damaged valve pit, complete all as specified and directed.
Construction of brick masonry valve pit of size 900 mm x 900 mm x 750 mm (internal dimensions of chamber) (depth shall be reckoned from the top of PCC in foundation to top of MS cover) with MS sheet cover 3mm thick including frame of angle iron 40 mm x 40 mm x 6 mm with locking arrangement with pad lock of size 50 mm brass, 6 levers and key (Make : GODREJ) and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc., including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 150mm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 metre, 15 cm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in PCC foundation projected by 150mm all round from the outer face of brick wall, PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in coping including dismantling old/damaged valve pit, complete all as specified and directed.
Construction of brick masonry valve pit of size 600 mm x 600 mm x 750 mm (internal dimensions of chamber) (depth shall be reckoned from the top of PCC in foundation to top of MS cover) with MS sheet cover 3mm thick including frame of angle iron 40 mm x 40 mm x 6 mm with locking arrangement with pad lock of size 50 mm brass, 6 levers and key (Make : GODREJ) and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc., including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 150mm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 metre, 15 cm thick PCC 1:4:8 type D-2 (40mm graded stone aggregate) as in PCC foundation projected by 150mm all round from the outer face of brick wall, PCC 1:2:4 type B-1 (20mm graded stone aggregate) as in coping including dismantling old/damaged valve pit, complete all as specified and directed.
Gland packing (best quality) 6 to 12 sq.mm area to stop leaking in Pump houses / sluice valves in fileld area, complete all as specified and dircted. MAKE:- Champion or techno-commercially equivalent make as approved by GE
Taking out existing Multi stage submersible pump (6 stages) of 40HP capacity, 3 phase, 415 V after disconnectring all electrical connections and transporting to workshop for repair and replacement of stainless steel bush / bearing, sleeves, brass / stainless steel impellors, CI body bowls of existing sizes, thrust plate / sand guard / strainer and reassembling after repair, re-fixing in existing position and making all connection and testing for smooth function without any vibration, complete all as specified and directed.
Taking out existing Submersible motor of capacity 40 HP, 3 Phase, 415 V after disconnecting all electrical connections and transporting the motor to workshop for rewinding with PVC insulated copper conductor, 'F' class insulation of existing gauge including cleaning of each slot and providing the insulating material and replacement of bush / bearing and reassembling after repair and re-fixing in existing position and making all connection and testing for smooth function without any vibration, complete all as specified and directed.
Making all arrangement of tripod stand, chain pulley, clamp for taking out MS column pipe of size 100 to 150 mm dia from existing borewell including motor, pump and submersible cable and lowering after cleaning and repair work including dismantling and refixing the flanged joint with fresh rubber gasket, complete all as specified and directed.
FASD (fully automatic star-delta) motor starter prewired suitable for 40 HP, 3 phase, 415 V with suitable relay of 415 V, MU contactors, electronic timer switch, single phase preventor, complete all as specified and directed. MAKE:- L&T / Seimens / Schneider
MS nut bolts, washers and foundation bolts made out of hard carbon steel with suitable threading to suit the requirement at site, complete all as specified and directed.
Rubber packing cotton braided not less than 3 mm thick of any size, complete all as specified and directed.
Thermal overload relay 415 V of range 28 to 42 Amp, fixed in repair, complete all as specified and directed. MAKE:- L&T Cat No. SS91859OOFO or techno-commercially equivalent model in Seimens / ABB
Power Contactor, 3 pole, ML-3 having AC3 rating, 80 Amps with 2 NO + 2 NC, auxilliary contacts, including taking down old unserviceable contactor of any rating, complete all as specified and directed. MAKE:- L&T / Schneider
Taking out old unserviceable chemical dosing pump and repair to fully automatic online pressure feed chemical dosing pump single phase, 230 Volts, 50 Hz, fully adjustable output cap with bleed valve assembly, skid mounted for water treatment complete with all accessories including replacement of FRP tank, 50 litre capacity, epoxy coated SS agitator shaft with motor, PH controller, pump maintenance kit, level switch, control panel and accessories as directed by manufacturer, complete all as specified and directed. MAKE:- Thermax Limited / Pure Aqua / Declibac
Taking down old unserviceable water level indicator and installation, testing and commissioning of digital type water level indicator device with 19mm size digit display including float switch / sensor and PVC insulated weather proof connection wire 1.0 sq.mm 4 core annealed copper conductor from over-head reservoir (OHR) to pump house (Approximately 20 metre length) and provision of necessary electric connection, complete all as specifiied and directed. MAKE:- SECO-DDS-2 / Active Control.
Supply and lay M S Pipes, 125mm bore, heavy grade 3 metre long, with all fittings laid in floors or fixed to walls and ceilings or lowering in borewells, complete all as specifiied and directed.
Supply and fill the silicious, free from foreign matters, washed and disinfected gravels of 10-12.5 mm size, rounded, conforming to IS- 4097: 1988, complete all as specifiied and directed.
PCC 1:2:4, type B-1, using 20 mm graded stone aggregate, around the tubewell to prevent the surface water contamination of the tubewell, complete all as specifiied and directed.
Taking out old unserviceable strainer and fixing in replacement CI body both end flange, 150mm dia, strainer in suction or delivery line, complete all as specifiied and directed.
Dismantling of existing sluice valve of 100 / 150mm bore and taking out operating rod and and check nut and transporting to workshop for repair of SS rod and replacement of brass check nut including threading, all lathe work and refixing in original position, complete all as specifiied and directed.
M/s Rajeev Kumar
UNIVERSAL ELECTRIC WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .