Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹10.0 L+₹11,659.73 (1.18%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹11.1 L+₹1.3 L (12.9%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹11.9 L+₹2.0 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Being 4rth lowest | |
| 5 | L5₹12.1 L+₹2.2 L (22.3%)Rejected-Finance 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
27 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MMD PRAVEEN NANDIKATTI GE AF SARSAWA
REPAIR/MAINT TO INDUSTRIAL HIGH WAY LIGHT, FLOOD LIGHTS, FLAME PROOF LIGHTS AND CONNECTED ITEMS AT AF STN SARSAWA UNDER GE(AF) SARSAWA
REPAIR/MAINT TO INDUSTRIAL HIGH WAY LIGHT, FLOOD LIGHTS, FLAME PROOF LIGHTS AND CONNECTED ITEMS AT AF STN SARSAWA UNDER GE(AF) SARSAWA
2022_MES_531048_3
8122/SAR-33/2022-23
Open Tender
Civil Works
Item Rate
333 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹30,000
Yes
4 Feb 2023
30 Aug 2022
3 Jan 2023
30 Aug 2022
27 Dec 2022
30 Aug 2022
Amount
Supply & fixing of LED aviation light yellow painted die cast aluminium alloy housing with five parellel circuits max 12 watt consumption with all accessories with and including one LED lamp 12 watt after taking out light fittings as existing at site complete all as specified and directed.
Supply & fixing of LED driver suitable for LED High bay light fittings 150 W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED Flood light fittings 150W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply & fixing of LED driver suitable for LED Flood light fittings 200W and of make same as of respective light fitting as existing at site including taking out of existing unservicable driver complete all as specified and directed.
Supply and fixing 150 watt LED High bay light with high luminous efficacy upto >=100 LPW , IP 66 protected , front polycarbonate cover with discrete high lumen LED , cast alluminium alloy housingn, input voltage range 140-270 volts auto cut off at voltage exceeding 300 volts, autopower on after cutt off with time delay of less than 60 seconds, power factor more than 0.95,, driver electrical efficiency not less than 85% at constant current delivery, with secondary optic lense for every LED, with five year warranty with name of manufacturer / logo clearly embossed on housing of every fitting, , including taking down existing light fittings complete all as directed and specified and directed.
Supply and fixing 150 watt LED Flood Light fitting with not less than 110 lumen / watt delivered system efficacy, cast aluminium alloy housing IP 66 protection, with secondory peanut lenses, potted driver, toughned glass input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, having name of manufacturer and logo embossed on housing of each light fitting, with five year manufacturer warranty certificate including taking down existing light fittings all as specified and directed.
Supply and fixing 200 watt LED Flood Light fitting with not less than 110 lumen / watt delivered system efficacy , cast aluminium alloy housing IP 66 protection, with secondory peanut lenses, potted driver, toughned glass input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light fitting, with five year manufacturer warranty certificate including taking down existing light fittings all as specified and directed.
Supply and fixing 250 watt LED Flood Light fitting with not less than 110 lumen / watt delivered system efficacy , cast aluminium alloy housing IP 66 protection, with secondory peanut lenses, potted driver, toughned glass input voltage range 140-270 volts, auto cut off at voltage exceeding 300 volts, auto power on after cut off with time delay of less than 60 seconds, power factor more than 0.95, driver electrical efficiency not less than 85 % at constant current delivery, with secondary optic lense for energy LED, having name of manufacturer and logo embossed on housing of each light with five year manufacturer warranty certificate fitting encluding all as specified and directed.
Supply & fix in replacement of flame proof LED flood light luminaries 120 watt comprising of body made in cast alluminum alloy LM6 construction luminaries spun alluminium reflector fitted inside main body main body, heat resistant toughend glass cemented to cast aluninuuim, retainging ring fixed to main body , mounted on MS galvanised iron cradle and base plate for rotating in horizontal and vertical planes, voltage 140-270,IP 65 , main connector suitable up to 6 Sqmm incoming cable, terminal enclosure plain covers are fixed by means of socket head allen cap stainless steel screw, conforming to standard IS/IEC 60079-0-2004, IS/IEC 60079-1-2007 , earthing with internal 1 No., external 2 Nos on main Enclosure M6x 12 MS screw & plain washer all as specified and directed by Engr-in-charge. Note:- (i) Contractor will provide 20 mtr height ladder/hydra to make hanger LED light fixing at your own arrangement complete all as specified and as directed.
S&F in replacement of sub main wiring with single core PVC insulated and unsheathed 1100 volt grade (FRLS) electric cable with multi stranded copper conductor of size 2.5 Sqmm phase and neutral drawn in and including ERW rigid steel stove enameled black conduit heavy duty ISI marked of size 20mm dia concealed type including all conduct fittings and accessories such as tees junction boxes, bends and including drawing continuous earth wire PVC insulated unsheathed 1100v grade cable with stranded copper conductor of size 2.5 Sqmm and connected to earth dolly complete all as specified and directed by Engrs-in-Charge. Note:- For item no.1 to 10 :- (i) Contractor will provide 20 mtr height ladder/hydra to replace/repair light fitting and connecting element and rate for making such arrangement deemed to be included in the quoted rate of respective item of schedule.
S & F in replacement of timer switch for security lights duly enclosed in suitable enclosure with locking arrangement. Fixed to wall/pole by means of clamp, nut, bolt and washers etc incl for comprising the following items :- (a) MCCB 63 A 16 KA 4 pole - 01 No Make :L&T/Schinder (b) MCB SPN 5 - 30 Amp - 01 No . Make : L&T/Strandard (c) Power contactor ML-3, 3 pole- 01 No . Make : L&T (d) Timer switch analog dial type -01 No. Make : L&T/Legrand (e) By pass arrangement for testing/repairing the lights
S&F in replacement multi stranded copper cable PVC insulated sheathed 1100 volts grade of size 2.5 sqmm 3 core, drawing through tubular pole and GI brackets etc upto LED light and making connections and testing for functioning of light fittings complete all as specified and as directed. Make:- Grandlay/ Havells/KEI
M&L for PCC 1 : 2 : 4 type B1 Using 20 mm graded stone aggregate for copping of poles/stay/panel/light plinth complete all as specified and directed .
S&F in replacement Non metallic Junction box made out of Thermoplastic size not less than 28 cm x17cmx10cm hinged with lockable arrangement including aluminium bus bar TPN capacity 200 Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed
S&F in replacement Non metallic Junction box made out of thermoplastic size not less than 18 cm x10cmx8cm hinged with locking arrangement including aluminium bus bar TPN capacity 100Amp with one No MCB 6 Amp SP with provision of tapping incoming and outgoing cable connection with gland box of suitable size and fixing on pole/grouting in PCC muff complete all as specified and directed.
Supply and fixing in replacement of 40 watt solar street light fitting complete with GI pipe med grade 50 mm bore 20 feet long grouted in PCC , with not less than 125 lumen / watt delivered lumen efficacy , total system lumens not less than 5000 lumen,solar PV module should be 12V 60W-Mono-crystalline & solar charge controller should be MPPT & its capacity not less than 12V,6A with battery (LiFeP04) with BMS 12.8V 24 Ah & its back up should be 2 days with dimming & its life span must be more than 50000 hours all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
Supply and fixing in replacement of flame proof/weather proof direct entry type rotary switch single pole on & OFF rotary motion switch in cast aluminum alloy LM-6 enclosure epoxy powder coated single pole 230Volts 10 Amps, AC ON/OFF switch operated externally by Knob having 02 Nos of M-20 cable entries, earthing terminals suitable for mounting on Wall/Steel structure all as specified and directed by Engr-in-charge.
Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 mtr deep for taking out/laying of U/G LT cable and getting out the excavated soil including triming the sides
Returning, filling in, incl spreading leveling, watering and well raming in layers not exc 25 centimetre thick in layer in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed Engr-in-Charge.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for Sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed. Note :- Only punned thichness shall be measured and punned down to 180 mm thick
Supplying, laying, jointing & testing of LT cables XLPE insulated, PVC sheathed aluminium conductors multistranded armoured heavy duty 1100 volt grade cross sectional area 10 sqmm 4 core laid in trenches/ducts/along poles/through pipe under road complete all as specified and as directed.
All as per item No 24 above but size 16 sq mm 4 core complete all as specified and as directed.
Supply and laying double walled corrugated HDPE duct pipe of 40 mm outer dia confirming to IS 14930 Pt II with antirodent and non flame propergating properties of approved colour complete with fitting for cable protection complete all as specified and as directed.
Labour for augering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified and directed
Sharma Electrical and Engineering Works
OMVIN ENTERPRISES LLP
SHRI RAM ENTERPRISES
VIJAY ENTERPRISES
G.H. INFRASTRUCTURE PRIVATE LIMITED
NAQLI LAL SHARMA AND ARUN SHARMA
SHARP ENGINEERING WORKS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .