1. Balance work of approach road and retaining wall for closure of LC gate no 33A on Sewagram-Ballarshah section. 2. Balance work of approach road, retaining wall and drainage arrangement for closure of LC gate no.11 on Sewagram-Ballarshah section. 3. Balance work of approach road and retaining wall for closure of LC gate no 71 on Wardha-Badnera section. 4. Construction of Relay Hut for Interlocking of LC Gate No 6 (Wani-Kayar) and 1C (Sewagram-Ballarshah) in Nagpur division.
DRMWNGP-57-2026-02
DRMWNGP-57-2026-02
Open
12 Months
Nagpur, Maharashtra
₹0
₹24.9 L
16 May 2026
16 May 2026
25 May 2026
1C (Sewagram-Ballarshah) in Nagpur division.
Item- 01 MS ITEM (DSR 2023)
S No. Item Description of Item Unit Qty Rate Amount
2.0 EARTH WORK
2.1S General
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.6 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and for all lift, as directed by
Engineer-in-charge.
Earth work in excavation by mechanical
means (Hydraulic excavator)/manual means
over areas (exceeding 30 cm in depth, 1.5 m
2.7 in width as well as 10 sqm on plan) including
getting out and disposal of excavated earth
lead upto 50 m and lift upto 1.5 m, as
directed by Engineer-in-charge.
2.27 Supplying and filling in plinth with sand under cum 192 2123.75 407760
3 floors, including watering, ramming,
consolidating and dressing complete.
4.0 CONCRETE WORK
4.1S CEMENT CONCRETE (CAST IN SITU)
Providing and laying in position cement
concrete of specified grade excluding the
cost of centering and shuttering - All work up
to plinth level :
derived from natural sources : 6 graded stone
aggregate 20 mm nominal size derived from
natural sources)
5.0 REINFORCEMENT CEMENT CONCRETE
5.9S FORM WORK
Centering and shuttering including strutting,
propping etc. and removal of form for
5.9.1 Foundations, footings, bases of columns, etc. Sqm 52 392.15 20391.8
for mass concrete
5.9.3 Suspended floors, roofs, landings, balconies Sqm 188 927.25 174323
and access platform
5.9.5 Lintels, beams, plinth beams, girders, Sqm 144 736.4 106041.6
bressummers and cantilevers
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Sqm 136 961.3 130736.8
5.9.16 Edges of slabs and breaks in floors and walls
5.22S STEEL REINFORCEMENT
NAGPUR CR DIVISION-ENGINEERING/CENTRAL RLY
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete upto plinth
5.22.6 Thermo-Mechanically Treated bars of grade Kg 4800 107.85 517680
Fe-500D or more.
Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in
position and binding all complete above
5.22A.6 Thermo-Mechanically Treated bars of grade Kg 5600 107.85 603960
Fe-500D or more.
5.33S DESIGN MIX CONCRETE
Providing and laying in position ready mixed
or site batched design mix cement concrete
for reinforced cement concrete work; using
coarse aggregate and fine aggregate derived
from natural sources, Portland Pozzolana /
Ordinary Portland /Portland Slag cement,
admixtures in recommended proportions as
per IS: 9103 to accelerate / retard setting of
concrete, to improve durability and
w o r k a b i l i t y without impairing strength;
including pumping of concrete to site of
laying, curing, carriage for all leads; but
excluding the cost of centering, shuttering,
finishing and reinforcement as per direction
of the engineer-in-charge, for the following
grades of concrete.:
5.33.1 All works upto plinth level
5.33.1.1 Concrete of M25 grade with minimum cement cum 36 9504.75 342171
content of 330 kg /cum
5.33.2 All works above plinth level upto floor V level
5.33.2.1 Concrete of M25 grade with minimum cement cum 40 9860.4 394416
content of 330 kg /cum
6.0 MASONRY WORK
6.26S EXPOSED BRICK WALL
Brick work with clay flyash F.P.S. (non
modular) brick of class designation 7.5 in
superstructure above plinth level up to floor
five level in :
9.0 WOOD AND P.V.C. WORK
9.1S FRAMES AND TRUSSES
Providing wood work in frames of doors,
windows, clerestory windows and other
frames, wrought framed and fixed in position
with hold fast lugs or with dash fasteners of
required dia & length (hold fast lugs or dash
fastener shall be paid for separately).
Providing and fixing panelling or panelling
and glazing in panelled or panelled and
glazed shutters for doors, windows and
clerestory windows (Area of opening for
panel inserts excluding portion inside
grooves or rebates to be measured).
Panelling for panelled or panelled and glazed
shutters 25 mm to 40 mm thick :
9.7.8 Fly proof stainless steel grade 304 wire Sqm 8 1800.45 14403.6
16 gauge with 0.5 mm dia. wire and 1.4 mm
wide aperture with matching wood beading
NAGPUR CR DIVISION-ENGINEERING/CENTRAL RLY
Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I)
decorative type, core of block board
9.20 construction with frame of 1st class hard
wood and well matched teak 3 ply veneering
with vertical grains or cross bands and face
veneers on both faces of shutters.
9.20.2 30 mm thick including ISI marked Stainless Sqm 20 3167.95 63359
Steel butt hinges with necessary screws
9.40S MISCELLANEOUS-WOOD WORK
Providing and fixing M.S. grills of required
pattern in frames of windows etc. with M.S.
9.48 flats, square or round bars etc. including
priming coat with approved steel primer all
COPER OXIDISED MILD STEEL FITTINGS
(COPPER OXIDISED AS PER IS: 1378)
Providing and fixing ISI marked oxidised M.S.
9.62 sliding door bolts with nuts and screws etc.
complete (Copper oxidised as per IS 1378)
9.70S STAINLESS STEEL FITTINGS
Providing and fixing IS : 12817 marked
9.71 stainless steel butt hinges (heavy weight)
with stainless steel screws etc. complete :
9.72S BRASS FITTINGS
Providing and fixing bright finished brass
handles with screws etc. complete:
9.82 Providing and fixing bright finished brass Each 8 121.65 973.2
22 hanging type floor door stopper with
necessary screws, etc. complete.
10.0 STEEL WORK
10.1S General
10.1 Structural steel work in single section, fixed Kg 5524.58 117.35 648309.46
with or without connecting plate, including
23 cutting, hoisting, fixing in position and
applying a priming coat of approved steel
primer all complete.
11.0 FLOORING
11.41S VITRIFIED FLOOR TILES
Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by
the manufacturer) with water absorption less
than 0.08% and conforming to IS: 15622, of
approved make, in all colours and shades,
laid on 20mm thick cement mortar 1:4 (1
cement : 4 coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sqm including
grouting the joints with white cement and
matching pigments etc., complete.
12.0 ROOFING
12.37S RAIN WATER SPOUT AND PIPE
NAGPUR CR DIVISION-ENGINEERING/CENTRAL RLY
12.50 Providing and fixing precoated galvanised Sqm 88 738.65 65001.2
iron profile sheets (size, shape and pitch of
corrugation as approved by Engineer-in-
charge) of total coated thickness 0.50 mm
(base metal of minimum 0.45 mm thickness
with total coating thickness of 0.05 mm) with
zinc coating 120 grams per sqm as per IS:
277, in 240 mpa steel grade, 5-7 microns
epoxy primer on both side of the sheet and
polyester top coat 15-18 microns. Sheet
25 should have protective guard film of 25
microns minimum to avoid scratches during
transportation and should be supplied in
single length upto 12 metre or as desired by
Engineer-in-charge. The sheet shall be fixed
using self drilling /self tapping screws of size
(5.5x 55 mm) with EPDM seal, complete upto
any pitch in horizontal/ vertical or curved
surfaces, excluding the cost of purlins, rafters
and trusses and including cutting to size and
shape wherever required.
13.0 FINISHING
13.1S CEMENT PLASTER (IN FINE SAND)
15 mm cement plaster on the rough side of
single or half brick wall of mix :
13.44S EXTERIOR FINISHING
Finishing with Deluxe Multi surface paint
13.48 system for interiors and exteriors using
Primer as per manufacturers specifications :
13.48.1 Two or more coats applied on walls @ 1.25 Sqm 1002 193.7 194087.4
28 ltr/10 sqm over and including one coat of
Special primer applied @ 0.75 ltr /10 sqm
13.48.3 Painting Steel work with Deluxe Multi Surface Sqm 225.6 170.7 38509.92
Paint to give an even shade. Two or more
29 coat applied @ 0.90 ltr/10 sqm over an under
coat of primer applied @ 0.80 ltr/10 sqm of
approved brand and manufacture
15.0 DISMANTLING AND DEMOLISHING
15.1S General
Demolishing cement concrete manually/ by
mechanical means including disposal of
material within 50 metres lead as per
direction of Engineer - in - charge.
(including equivalent design mix)
15.60 Disposal of building rubbish / malba / similar cum 4 263.95 1055.8
unserviceable, dismantled or waste materials
by mechanical means, including loading,
31 transporting, unloading to approved
municipal dumping ground or as approved by
Engineer-in-charge, beyond 50 m initial lead,
for all leads including all lifts involved.
21.0 ALUMINIUM WORK
21.1S General
NAGPUR CR DIVISION-ENGINEERING/CENTRAL RLY
Providing and fixing aluminium work for
doors, windows, ventilators and partitions
with extruded built up standard tubular
sections/ appropriate Z sections and other
sections of approved make conforming to IS:
733 and IS: 1285, fixing with dash fasteners
of required dia and size, including necessary
filling up the gaps at junctions, i.e. at top,
bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections
shall be smooth, rust free, straight, mitred
and jointed mechanically wherever required
including cleat angle, Aluminium snap
beading for glazing / panelling, C.P. brass /
stainless steel screws, all complete as per
architectural drawings and the directions of
Engineer-in-charge. (Glazing, panelling and
dash fasteners to be paid for separately) :
21.1.1 For fixed portion
thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators
including providing and fixing hinges/ pivots
and making provision for fixing of fittings
wherever required including the cost of EPDM
rubber / neoprene gasket required (Fittings
shall be paid for separately)
thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium
door, window, ventilator shutters and
partitions etc. with EPDM rubber / neoprene
21.3 gasket etc. complete as per the architectural
drawings and the directions of engineer-in-
charge . (Cost of aluminium snap beading
shall be paid in basic item):
21.3.1 With float glass panes of 4.0 mm thickness Sqm 30 1176.8 35304
(weight not less than 10kg/sqm)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TENDER DOCUMENT
ATTACHMENT
PCECir-207.pdf
ATTACHMENT
PCECir.208.pdf
ATTACHMENT
Specialconditions.pdf
ATTACHMENT
57-2026-02Bal.wkofapproachLCgatesSOUTH.pdf
ATTACHMENT
Download all tender documents and submit your bid