Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC | L1 | Accepted-AOC AOC |
Tender Value
₹3.8 L
EMD Value
₹7,500
Closing Date
29 Jun 2021, 5:00 pmClosed
Executive Engineer
HPSIDC Ltd. Shimla
(SH- Providing electrical installation thereof).
2021_SIDC_48916_1
Job No. 3
Open Tender
Electrical Works
Item Rate
90 days
Junga
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹7,500
11 Nov 2021
23 Jun 2021
30 Jun 2021
23 Jun 2021
29 Jun 2021
23 Jun 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box, Fan Box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and as per direction of the Engineer-in-charge.. Group A.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required and as per direction of the Engineer-in-charge.. (i) S.P. 5/ 6 Amps one way Modular switch.
(ii) 5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Wiring for light plug with 2 x 1.5 Sq. mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required and as per direction of the Engineer-in-charge.
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. PVC insulated HRFR LS Copper conductor 10 Sq. mm. 2x 10 Sqmm.
Wiring for power plug with 2 x 4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No. 4 Sqmm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required and as per direction of the Engineer-in-charge. Single pole. Cat-A.
Supplying and fixing following rating, double pole 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp. Cat-A
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required and as per direction of the Engineer-in-charge.. (i) 40 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required and as per direction of the Engineer-in-charge.(i) Double door-12 way
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required and as per direction of the Engineer-in-charge..
Extra for using salt and charcoal for pipe earth electrode complete as required and as per direction of the Engineer-in-charge..
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required and as per direction of the Engineer-in-charge..
Supplyign and fixing call bell/ buzzer, suitable for D.C./A.C. single phase, 230 volts complete as required.
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but in/c CFL lamp including making connections, testing etc. as required and as per direction of the Engineer-in-charge. (i) Fixed type wall bracket 150 dia, single lamp.(Category-A)
Supplying and fixing of bulk head fitting of all sizes and shapes, containing one No. thread type CFL lamp holder (s), complete with all accessories but in/c CFL lamp including making connections, testing etc. as required. and as per direction of the Engineer-in-charge.(i) Bulk head fitting, CFL type (Category-A)
Supplying and fixing plain pendent with 16/0.20mm twin twisted, flexible, PVC insulated, cotton braided, copper cable and bakelite pendent holder including connections etc. as required.
Supplying and fixing bakelite batten/ angle holder including connections etc. as required.
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) or up to required length with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Model to be got approved from engineer in charge.(i) Ceiling Fan 1200 mm sweep, Category-A
Supplying and fixing stepped type modular fan regulator on the existing modular box including making connections etc. as required.
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required. Exhaust Fan, light duty, (Domestic) 225mm sweep
Providing & fixing surface/ recess mounted 15W LED fitting of approved make complete as required and as per direction of the Engineer-in-charge.
Providing & fixing reputed make light emitting diode of following rating as required 7-9 watt. Complete fitting of approved make as required and as per direction of the Engineer-in-charge.
Providing and fixing LED Baton aluminium body fitting 18/20 W of Approved make (Bajaj) or equivalent complete in all respect and as per direction of the Engineer-in-charge.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .