Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.6 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹31.0 L+₹2.3 L (8.20%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹40.3 L+₹11.7 L (40.7%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹40.9 L+₹12.3 L (42.8%)Rejected-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹43.9 L+₹15.3 L (53.4%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | SUN MANN ENGINEERS L2 | somyaenterprises L3 | DUGGAL CONSTRUCTION CO L1 | J.K & Company L4 | PAWAN KUMAR GOVT. CONTRACTORS L5 | ASHWANI SETHI L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface all as directed | 9 | Each | 100 ₹900 Lowest | 1,000 ₹9,000 | 100 ₹900 Lowest | 200 ₹1,800 | 1,500 ₹13,500 | 1,000 ₹9,000 |
| 2.00 | Supply fabricating erecting LT panel outdoor type CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply factory made fully compart mentalized made out of 3.00 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of abgle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioning with including the following :- (a) Aluminium bus bar of capacity 400 Amps for Three phase and Neutral. -04 No's
(b) Combined Voltmeter 415V, Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three), Indicator lamp
Incoming : (i) MCCB 4P 250 Amps, 36 KA 415 Volts (Thermal Magnatic and microprocessor release- 01 No
Outgoing :
(i) MCCB FP 125 Amps 16 KA 415 Volts (adjustable thermal and magnatic type70% to 100%)- 02 N
(ii) MCB TPN, 63 Amps, 16 KA 415 Volts.- 02 No's
(iii) Digital type Digital Timer switch suitable for 3 phase, 415 volts AC supply for street light feeder programmable 1 min, with backup for 6 years, 28 memory locations, current capacity 10 Amps weekly program with 1 changeover (1co) total 28 programs Model No DIN, Type ECO weekly with 1 CO cat part No TDA44196. | 3 | Each | 97,000 ₹2,91,000 | 90,000 ₹2,70,000 | 81,000 ₹2,43,000 Lowest | 1,08,500 ₹3,25,500 | 99,500 ₹2,98,500 | 1,95,000 ₹5,85,000 |
| 2.10 | Supply fabricating erecting LT panel outdoor type CPRI approved double door totally enclosed weather and vermin proof suitably ventilated 415 Volts 50 cycles, AC supply factory made fully compart mentalized made out of 3.14 mm thick CRCA sheet for laod bearing and 2.00 mm thick for nonload bearing protection of enclose IP 54 as per IS 2147 of 1962 with pretreatment and powder coated of approved colour including suitable size of abgle iron/flat iron frame work/ support required civil works, excavation & earth work, PCC foundation etc, installation, testing & commissioning with including the following :- (a) Aluminium bus bar of capacity 250 Amps for three phase and Neutral.-04 No's
(b) Combined Voltmeter & Ammeter 0 to 500 Amps digital type with built in selector switch CTS of suitable ratio (Set of Three)
Incoming : (i) MCCB TPN 160 Amps, 36 KA 415 Volts - 01 No's
Outgoing :
(i) MCCB 4 pole 100 Amps 25 KA 415 Volts - 03 No'
(ii) MCCB 4 pole 63 Amps 25 KA, 415 Volts - 02 No's | 6 | Each | 69,000 ₹4,14,000 | 65,000 ₹3,90,000 | 57,000 ₹3,42,000 Lowest | 72,000 ₹4,32,000 | 72,500 ₹4,35,000 | 1,50,000 ₹9,00,000 |
| 3.00 | M & L for earthing complete with galvanized iron or steel or steel earth plate electrode of size 60cmx60cmx6.3mm thick buried directly in ground, vertically to a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides with alternate layers of charcoal and common salt and connected to GI Strip of size 32x6 mm by means of GI bolts, nuts washers & check nuts electrode connected to main switch board or main control board or on poles or on transformer and GI pipe light grade 20 mm bore for watering including providing funnel and wire mesh GI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown in plate No 5 of SRR-1991 Part-1 . | 14 | Each | 3,200 ₹44,800 Lowest | 4,500 ₹63,000 | 3,200 ₹44,800 Lowest | 3,200 ₹44,800 Lowest | 4,800 ₹67,200 | 4,000 ₹56,000 |
| 4.00 | M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. | 8 | Each Job | 2,000 ₹16,000 Lowest | 4,500 ₹36,000 | 2,900 ₹23,200 | 3,000 ₹24,000 | 4,700 ₹37,600 | 2,500 ₹20,000 |
| 5.00 | Preparation to steel surface of existing LT panels, LT feeder pillars boxes of any size and description internally and externally after scraping and scratching the old paint with emery paper etc, and painting with two coat of gray painting with spray gun and writing feeder names and numbers with suitable capital letters in English with white paint on and a black paint strip of size 20 cm x 25 cm all as directed. | 10 | Each | 500 ₹5,000 | 1,000 ₹10,000 | 300 ₹3,000 Lowest | 400 ₹4,000 | 2,500 ₹25,000 | 1,000 ₹10,000 |
| 6.00 | Material and labour for repair to LT panels feeder pillar box by dismantling old rusted and perished doors shutter and bus bar covers etc and providing new doors shutters, bus bar cover etc by cutting, welding, fabricating and made to existing shape with 3.15 mm plain black sheet and angle iron of required size including providing hinges and locking arrangement all as directed including material and labour for two coat of painting with synthetic enameled Grey paint over a coat of red oxide primer. | 10 | Each | 780 ₹7,800 | 1,500 ₹15,000 | 300 ₹3,000 Lowest | 400 ₹4,000 | 2,000 ₹20,000 | 1,000 ₹10,000 |
| 7.00 | Supply and fixing in replacement MCCB, 4 pole, 3 phase, 415 volts, 400 Amps, repturing capacity 35 KA with overload and thermal tripping features. Make-Havell’s/ABB/Legrand | 4 | Each | 14,500 ₹58,000 | 22,500 ₹90,000 | 12,000 ₹48,000 Lowest | 13,500 ₹54,000 | 17,500 ₹70,000 | 19,000 ₹76,000 |
| 8.00 | All as per item No 7 here-in-before but 250 Amps repuring capacity 36 KA. | 4 | Each | 10,800 ₹43,200 | 11,000 ₹44,000 | 10,000 ₹40,000 | 9,000 ₹36,000 Lowest | 12,800 ₹51,200 | 18,000 ₹72,000 |
| 9.00 | All as per item No 7 here-in-before but 200 Amps repuring capacity 25 KA. | 5 | Each | 6,800 ₹34,000 | 10,500 ₹52,500 | 6,000 ₹30,000 Lowest | 8,200 ₹41,000 | 11,500 ₹57,500 | 15,000 ₹75,000 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
16 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Kapurthala
GE Kapurthala
Repair/replacement and maintenance of LT Over head line, cable, allied works at Mil Stn Beas under GE Kapurthala.
2025_MES_741561_1
8103/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹98,000
28 Mar 2026
26 Nov 2025
18 Dec 2025
26 Nov 2025
16 Dec 2025
9 Dec 2025
Taking down existing LT panel by disconnecting all incoming and outgoing cables, earthing connection, dismantling PCC and making good the disturbed surface all as directed
Material and labour for repair to LT panels feeder pillar box by dismantling old rusted and perished doors shutter and bus bar covers etc and providing new doors shutters, bus bar cover etc by cutting, welding, fabricating and made to existing shape with 3.15 mm plain black sheet and angle iron of required size including providing hinges and locking arrangement all as directed including material and labour for two coat of painting with synthetic enameled Grey paint over a coat of red oxide primer.
Supply and fixing in replacement MCCB, 4 pole, 3 phase, 415 volts, 400 Amps, repturing capacity 35 KA with overload and thermal tripping features. Make-Havell’s/ABB/Legrand
S&F in repair on load change over switch 4 pole 400 Amps in sheet metal enclosure make :- Indio asian cat part ICASO400 or equivalent inHavells,C&S, L&T
Supply and fixing aluminum thimbles/Lugs crimping type of size 16 to 25 Sq mm
Supply and fixing aluminum thimbles/Lugs crimping type of size 50 to 120 Sq mm
Supply and fixing aluminum thimbles crimping type of size 150 Sq mm to 240 Sq mm all as specified.
Supply, stringing and fixing on existing poles, ACSR conductor of any type/ size including fixing to insulators with binding wire complete all as directed by Engr-in- Charge Make: Allind, ICC, Bharat Conductor,VK conductors,NICCO.
Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including segregating the serviceable cable by cutting down defective portion after testing by meggar and relaying (Note : Excavation and earth work will be measured separately under respective item)
Taking out old defective underground cable from trenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including segregating the serviceable cable by cutting down defective portion after testing by meggar.(Approx 700 is reduced for old ACSR where required.
Supply, Laying, jointing and testing XLPE PVC insulated & PVC sheathed LT cable, 1100 volts grade (heavy duty )with stranded aluminium conductor, cross sectional area 10 Sqmm 2 core fixed along the poles or passing through pipes or laid under floors or through walls complete all as specified. Note (i) Earthwork, sand cushioning, brick protection and GI pipe to be measured and paid for separately under respective items.
All as per description of serial item no.15 here in before but cross sectional area 16 Sqmm 2 core complete all specified.
All as per description of serial item no.15 here in before but cross sectional area 16 Sqmm 4 core complete all specified.
All as per description of serial item no.15 here in before but cross sectional area 25 Sqmm 3½ core complete all specified.
All as per description of serial item no.15 here in before but cross sectional area 35 Sqmm 3½ core complete all specified.
All as per description of serial item no.15 here in before but cross sectional area 50 Sqmm 3½ core complete all specified.
All as per description of serial item no. 15 here in before but cross sectional area 70 Sqmm 3½ core complete all specified.
All as per description of serial item no. 15 here in before but cross sectional area 95 Sqmm 3½ core complete all specified.
All as per description of serial item no. 15 here in before but cross sectional area 120 Sqmm 3½ core complete all specified.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out including trimming of sides complete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified.
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge. (for LT Cable )
M&L for road cutting for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe complete all as specified
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate for fdn of poles, stay etc.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting at side for re-use with in 50m
Material and labour for mild steel cross arms,bracing,supports,clamps and back plates fabricated from structural steel section including nuts,bolts washers,welding,bending cold or hot, drilling holes for bolts in any shape/size as directed including painting with two coats of approved colour over a coat red oxide primer all as specified and directed by Engr-in-Charge
M&L galvanised stay strand size 7/4 mm complete all as specified and directed by Engr-in-Charge.
Taking down insulators off any size & type.
Supply and fix pin type, porcelain,vitreous,white brown or green insulator including one galvnised mild steel spindle, two nos galvanised iron washer and one galvnised iron nut, 100mm height,65mm dia for 1100v grade
Supply and install in replacement of prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l2mm x 279mm at bottom, class 10
Supply and fix, Volt meter 0-15KV with PT, digital type, suitable for LT panel 415V, as in replacement, complete all as specfied and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tender8103.pdf
Tender Documents • 1.22 MB
BOQ_830373.xls
BOQ • 1.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .