Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.8 LAdmitted-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹54.8 L | L1 | Admitted-Finance |
| 2 | L2₹57.1 LAdmitted-Finance | ₹57.1 L | L2 | Admitted-Finance |
| 3 | L3₹57.7 LAdmitted-Finance COLABA MUMBAI | ₹57.7 L | L3 | Admitted-Finance |
| 4 | L4₹58.2 LAdmitted-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹58.2 L | L4 | Admitted-Finance |
| 5 | L5₹58.4 LAdmitted-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | ₹58.4 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Chakshu Enterprise L8 | sapana enterprises L4 | pk Enterprises L6 | BRITE INDUSTRIES L2 | Shree Ayyappa Engineering L1 | Veer High Tech Solution L3 | Maruti Abhiyantriki L7 | shakti engineering and electrical works L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | periodical and servicing through agency authorized by OEM of HT VCB, 11 KV, 400/630/800 Amps of make AREVA/ ABB / CG/Schneider/ Seimens installed at various locations including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gaskets, washers, panel heater, indicator bulbs and carry out any other repairs required at site to make the VCB fully functional, complete all as specified and directed (i) Checking of Draw out mechanism/arrangement of VCB (ii)Inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts if any. (iii) Checking of alignment with spout and setting of contact gaps. (iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease. (v) Checking/setting of master control relay, earth fault realy and overload realy. (vi) Also checking ON/OFF/TRIP indication and make it serviceable by necessary checking/repair/replacement of control wiring. Replacement of Push button for open and Close, micro switches, indication lamps. (vii) Decarburizing and re-insulation of complete busbar track system complete in all respect. (viii) Misc works deemed essential to make VCB in perfectly working order.
Note : Major spare parts are to be paid sepratly under respective items here in after, however cost of minor spares shall be deemed to be included in item rate. | 32 | Each Job | 11,000 ₹3.5 L | 12,065 ₹3.9 L | 9,800 ₹3.1 L | 11,000 ₹3.5 L | 10,800 ₹3.5 L | 12,019 ₹3.8 L | 12,058 ₹3.9 L | 12,055 ₹3.9 L |
| 2.00 | Overhauling and servicing through agency authorised by OEM of HT RMU SF6 11 KV, 400/630 Amps of make Schneider / ABB installed at various locations including SF6 Gas Leakage test and SF6 Gas Refilling , Oiling,Greasing,cleaning of all contacts with CT's and replacement of minor parts such as Gasket, washers, panel heater and indicator bulbs and any other repair Such as Service and Repair for Manual handle operation unit,as well as Motor Operated Spring Charge Control,Push button servicing for Breaker On/OFF etc,required at site to make the RMU fully functional, complete all as specified and directed | 3 | Each Job | 11,000 ₹33,000 | 11,935 ₹35,805 | 9,800 ₹29,400 | 11,000 ₹33,000 | 10,000 ₹30,000 | 12,019 ₹36,057 | 12,058 ₹36,174 | 12,055 ₹36,165 |
| 3.00 | Filtration & Dehydration of transformer oil (at different locations) using ON-LINE filtration plant to achieve dielectric strength minimum 50 KV/ 4mm including testing of oil before and after dehydation, complete all as specified and directed..
Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration. | 900 | Litre | 30 ₹27,000 | 58 ₹52,200 | 88 ₹79,200 | 100 ₹90,000 | 22 ₹19,800 | 40 ₹36,000 | 83 ₹74,700 | 80 ₹72,000 |
| 4.00 | Material for topping up to transformer oil conforming to IS 395-1983 (Make : 'Savita', 'Power Oil', APAR) having die electric strength minimum 50 KV at 4mm gap complete all as specified and directed.
Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer.
(b) Transformer oil shall be supplied in sealed barrel with test result and test certificate. Empty cantainer shall be property of contractor. | 300 | Litre | 1,200 ₹3.6 L | 208 ₹62,400 | 150 ₹45,000 | 126 ₹37,800 | 157 ₹47,100 | 190 ₹57,000 | 233 ₹69,900 | 230 ₹69,000 |
| 5.00 | Calibration of Microprocessor based Over Current and Earth Fault( O/C+E/F) Numerical relays by secondary injection and testing kits in accordance with existing load (in peak hours) cleaning the relays with CTC/Petrol including checking and making connections of control wiring of fault control systems from relays to CTs/PTs, operating and measuring instruments, selector switches including making them functional (Each VCB shall be tested for feeding load current / fault current by primary/secondary injection test kit) complete all as specified and directed. (Note :- This work shall be got carried out by the contractor from the OEM authorised agent.) Locatio MO MB GHATKOPAR (Note : This work shall be carried out from the OEM authorised agent.) | 32 | Each Job | 1,200 ₹38,400 | 3,833 ₹1.2 L | 1,200 ₹38,400 | 3,900 ₹1.2 L | 3,420 ₹1.1 L | 3,815 ₹1.2 L | 3,858 ₹1.2 L | 4,000 ₹1.3 L |
| 6.00 | Calibration of relays of HT RMU by secondary and primary injection, replacement of selector switches, voltmeters, ammeters for HT supply, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV parts of master relays, complete all as specified and directed. | 3 | Each Job | 1,200 ₹3,600 | 3,833 ₹11,499 | 3,868 ₹11,604 | 3,900 ₹11,700 | 3,420 ₹10,260 | 3,815 ₹11,445 | 3,858 ₹11,574 | 4,000 ₹12,000 |
| 7.00Overhauling of step down outdoor/indoor transformer (Make:- WESTERN / INDIAN Transformer Ltd / Volts) 11/0.433 KV by disconnecting HT/LT terminals, decanning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, reassembling refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint after preparation of painted surfaces of transformer and testing and recommissioning on load etc, complete for the transformers of following rating (Filteration and dehydration of transformer oil, supply only transformer oil for topping up, supply only of HT & LT bushings shall be measured and paid separately under respective items) | |||||||||||
| 7.01 | Transformer 630 KVA | 1 | Each Job | 300 ₹300 | 5,333 ₹5,333 | 5,311 ₹5,311 | 5,387 ₹5,387 | 4,770 ₹4,770 | 5,268 ₹5,268 | 5,235 ₹5,235 | 5,344 ₹5,344 |
| 7.02 | Transformer 500 KVA | 2 | Each Job | 300 ₹600 | 4,817 ₹9,634 | 4,861 ₹9,722 | 4,937 ₹9,874 | 4,365 ₹8,730 | 4,818 ₹9,636 | 4,785 ₹9,570 | 4,894 ₹9,788 |
| 7.03 | Transformer 400 KVA | 2 | Each Job | 1,000 ₹2,000 | 4,332 ₹8,664 | 4,376 ₹8,752 | 4,452 ₹8,904 | 3,900 ₹7,800 | 4,333 ₹8,666 | 4,300 ₹8,600 | 4,409 ₹8,818 |
Tender Value
₹55.5 L
EMD Value
₹1.1 L
Closing Date
23 Apr 2026, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
PREVENTIVE MAINT/ REPAIR AND MAINT OF HT VCB, ISOLATOR, RELAYS, TRANSFORMERS, APFC PANELS AND HT CABLES AT MO (MB) GHATKOPAR/ NAE SANTACRUZ AND REPAIR/ REPALCEMENT OF FIRE FIGHTING AND FIRE ALARM SYSTEM AT MO (MB) GHATKOPAR UNDER CWE (SUBS) BHANDUP
2026_MES_757858_1
8431/E8
Open Tender
Electrical and Maintenance Works
330 days
GHATKOPAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) BHANDUP
₹1.1 L
7 May 2026
26 Mar 2026
25 Apr 2026
26 Mar 2026
23 Apr 2026
16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
periodical and servicing through agency authorized by OEM of HT VCB, 11 KV, 400/630/800 Amps of make AREVA/ ABB / CG/Schneider/ Seimens installed at various locations including cleaning of all VCB contacts with CT's and replacement of minor parts such as Gaskets, washers, panel heater, indicator bulbs and carry out any other repairs required at site to make the VCB fully functional, complete all as specified and directed (i) Checking of Draw out mechanism/arrangement of VCB (ii)Inspection of isolating Contacts, and decarburizing the male /female contacts, jaws complete and replacement of worn out contacts if any. (iii) Checking of alignment with spout and setting of contact gaps. (iv) Replacement of worn out/defective minor spares parts, lubrication of moving parts of the truck by moly grease. (v) Checking/setting of master control relay, earth fault realy and overload realy. (vi) Also checking ON/OFF/TRIP indication and make it serviceable by necessary checking/repair/replacement of control wiring. Replacement of Push button for open and Close, micro switches, indication lamps. (vii) Decarburizing and re-insulation of complete busbar track system complete in all respect. (viii) Misc works deemed essential to make VCB in perfectly working order.
Note : Major spare parts are to be paid sepratly under respective items here in after, however cost of minor spares shall be deemed to be included in item rate. | - | Each Job | - | - | |
Overhauling and servicing through agency authorised by OEM of HT RMU SF6 11 KV, 400/630 Amps of make Schneider / ABB installed at various locations including SF6 Gas Leakage test and SF6 Gas Refilling , Oiling,Greasing,cleaning of all contacts with CT's and replacement of minor parts such as Gasket, washers, panel heater and indicator bulbs and any other repair Such as Service and Repair for Manual handle operation unit,as well as Motor Operated Spring Charge Control,Push button servicing for Breaker On/OFF etc,required at site to make the RMU fully functional, complete all as specified and directed | - | Each Job | - | - | |
Filtration & Dehydration of transformer oil (at different locations) using ON-LINE filtration plant to achieve dielectric strength minimum 50 KV/ 4mm including testing of oil before and after dehydation, complete all as specified and directed..
Note: 1.Oil samples are to collected from top and bottom of oil tank and test results to be recorded for each sample before and after filteration. | - | Litre | - | - | |
Material for topping up to transformer oil conforming to IS 395-1983 (Make : 'Savita', 'Power Oil', APAR) having die electric strength minimum 50 KV at 4mm gap complete all as specified and directed.
Notes : (a) New Transformer oil will be filled in the transformer only after filteration and dehydration of existing transformer oil of the transformer.
(b) Transformer oil shall be supplied in sealed barrel with test result and test certificate. Empty cantainer shall be property of contractor. | - | Litre | - | - | |
Calibration of Microprocessor based Over Current and Earth Fault( O/C+E/F) Numerical relays by secondary injection and testing kits in accordance with existing load (in peak hours) cleaning the relays with CTC/Petrol including checking and making connections of control wiring of fault control systems from relays to CTs/PTs, operating and measuring instruments, selector switches including making them functional (Each VCB shall be tested for feeding load current / fault current by primary/secondary injection test kit) complete all as specified and directed. (Note :- This work shall be got carried out by the contractor from the OEM authorised agent.) Locatio MO MB GHATKOPAR (Note : This work shall be carried out from the OEM authorised agent.) | - | Each Job | - | - | |
Calibration of relays of HT RMU by secondary and primary injection, replacement of selector switches, voltmeters, ammeters for HT supply, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV parts of master relays, complete all as specified and directed. | - | Each Job | - | - | |
Overhauling of step down outdoor/indoor transformer (Make:- WESTERN / INDIAN Transformer Ltd / Volts) 11/0.433 KV by disconnecting HT/LT terminals, decanning transformer oil, removing sludge, cleaning of HT /LT bushings to remove dust particles /dirt etc, cleaning the core and winding with compressed air including replacement of copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, reassembling refilling the transformer oil after filteration and dehydration and toping up with new transformer oil, painting with two coats of synthetic enamel paint after preparation of painted surfaces of transformer and testing and recommissioning on load etc, complete for the transformers of following rating (Filteration and dehydration of transformer oil, supply only transformer oil for topping up, supply only of HT & LT bushings shall be measured and paid separately under respective items) | - | - | - | - | |
Transformer 630 KVA | - | Each Job | - | - | |
Transformer 500 KVA | - | Each Job | - | - | |
Transformer 400 KVA | - | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tenderdocus.pdf
Tender Documents • 1.19 MB
BOQ_848887.xls
BOQ • 0.51 MB
Download all tender documents and submit your bid