Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹14.4 L
Closing Date
11 Jul 2026, 9:30 pm
University of Horticultural Sciences
SPO/TN-222/Establishment of Common Incubation Centre for processing of fruits, vegetables at COH, Bidar including of Construction Works
57939
UHS/2025-26/IND0052/CALL-3
Open
University of Horticultural Sciences Bagalkote
38 documents required · 38 mandatory
Performance and Satisfactory / Experience reports issued by the any state government / Central Government undertaking and Universities, the Bidder should have executed 80% of OEM or 30% of authorized dealer same nature of work completed in any last five financial years.
If the bidder is an OEM has to upload documents of having supplied 80% of tender quantity of similar goods Purchase orders with satisfactory or completion report.
To qualify for Award of this contract, (i) Each Tenderer in its name should have in the last five years i.e., 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25(b) Satisfactory completed (at least 90% of contract value) as prime contractor at least one similar nature work of (single building work only with water supply / sanitary and electrification works) in State Government /Central Government / Public Sector Undertaking / Municipal Corporations of State Government /Central Government shall be with RCC framed structure including Excavation, PCC works, RCC footings, RCC roof, RCC columns and Beam works, value not less than Rs.1,72,50,457.00This has to be supported by the certificate issued by the officer not below the rank of an Executive Engineer.
To qualify for Award of this contract, (i) Each Tenderer in its name should have in the last five years i.e., 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25(c) Executed in any one year during 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25 following minimum quantities of works. Sl.No., Description, Unit, Qty, Required, 1, Earthwork Excavation, Cum, 640.80, 2, Cement concrete RCC / PCC, Cum, 306.40, 3, Laterite masonry / Bricks masonry, Cum, 109.60, 4, Steel reinforcement / TMT Steel, Tonne, 23.60, 5, Flooring with Granite / vitrified / glazed tile / ceramic / kota /Cement Flooring (Qty inclusive of all), Sqm, 559.20, 6, Plastering, Sqm, 1512.00, 7, Providing and applying painting, Sqm, 1888.00, 8, Structural Steel, Kgs, 19680.00
The Bidder should be a firm /Company registered as evidenced by a certificate of registration / Incorporation and should be in the Related Business as detailed in the scope of work. The Bidder should be in Existence for a minimum period of 5 (Five) Years.
Tenderer/ Bidders should furnish OEMs Manufacturer Authorization Certificate (MAF) for each of the product / Equipment quoted authorizing Tenderer/ Bidder for participating in the tender on behalf of the OEMs concerned on their letterhead
The Bidder must attach as per given all technical specifications Compliance sheet in their letterhead for all items along with the brochures of each of the item of the equipment quoted
Manufacturing License if Manufacturer is participating.
Authorization certificate if an Authorized Delear is participating (MAF & Authorization Certificate).
If the bidder is an authorized dealer has to upload 30% of tender quantity of similar items supplied purchase orders with satisfactory or completion certificate along with OEMs 80% purchase orders / satisfactory completion reports.
Declaration on judiciary bond paper stating that the company / bidder is not blacklisted.
KPWD Registration certificate scanned copy attached
The agency shall submit Statement indicating (I) Existing commitments and ongoing works The above statements should be furnished as per clauses 1.5 (A) of Section 3 of Qualification information of Standard Bid document (as per the table). These documents shall be countersigned by engineer in-charge not below the rank of Executive Engineer. (A) Existing Commitments and on-going works Description of work, Place and state, Contract No. & Date, Name and address of employer, Value of contract (Rs. Lakhs), Stipulated period of completion, Value of works remaining to be completed (Rs. Lakhs), Anticipated date of completion
The agency shall submit Statement indicating (I) Works for which tenders are already submitted The above statements should be furnished as per clauses 1.5(B) of Section 3 of Qualification information of Standard Bid document (as per the table). These documents shall be countersigned by engineer in-charge not below the rank of Executive Engineer (B) Works for which tenders already submitted Description of work, Place & State, Name and address of employer, Estimated value of works (Rs. Lakhs), Stipulated period of completion, Date when decision is expected, Remarks if any
The tenderer has to furnish the details of Technical Personnel working/Associated with him.
Each Tenderer should further demonstrate: Availability by owning/hiring of the required/specified key and critical equipments for this work as per the table appended here with by giving information about brief specification of the equipment as per 1.6 of clause 3.3 (a Availability by owning at least 50% of the required following key and critical equipments for this work (b) the remaining 50 % can be deployed on lease/hire for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished) in respect of this agreement copy should be enclosed for hiring. Sl.No., Description of the Equipment, Owned, Hired, Total No.s, 1, Tipper/Lorry, 1, 1, 2, 2, Concrete Mixture, 1, 1, 2, 3, Pin Vibrator, 1, 1, 2, 4, Water tanker, 1, 1, 2
Bid capacity the bidder shall necessarily enclose duly filled and completed tender capacity in enclosed format
PF & ESI registration certificate
Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity (AxNx1.5 B)Where A is Maximum value of civil engineering works executed in any one year during the last five years (updated to 2025-26 price level) taking into account the completed as well as works in progress.N -Number of years prescribed for completion of the works for which tenders are invited-0.92Year.B Value, at 2025-26 price level, of existing commitments and on-going works to be completed during the next 0.92year (Period of completion of the works for which tenders are invited)
Tenderer / Bidders should enclose Turnover certificate for the last three financial years i.e., 2022-23, 2023-24, 2024-25 and the Bidder will have to attach documentary evidence confirming that they have average annual turnover of 80% for Manufacturer or 30% for Authorized dealer.
Qualification Criteria : a) Technical Capacity : The Tenderer should be a Manufacturer / Authorized Dealer who must have manufactured (80%) as an OEM or as an Authorized Dealer must have supplied similar Goods at least (30%), b) Financial Capacity The tenderer should have annual turnover of not Less than 30% for authorized dealer or 80% for the OEMs as per estimated cost
GST Registration Certificate shall be enclosed.
GST Returns Certificate GSTR 3B returns certificate for the last 6 months is to be uploaded.
PAN Card of the tenderer shall be enclosed.
Annual Turnover for the last 3 Years certified by CA along with UDIN Number shall be uploaded
PAN Card (Enclose PAN Card)
Income tax returns of preceding last three years i.e., 2022-23, 2023-24 and 2024-25.
GST Registration Certificate
To qualify for Award of this contract, (i) Each Tenderer in its name should have in the last five years i.e., 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25 (a)Achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 3,83,34,348.00
The agency shall submit the total value of Civil Engineering Construction works executed and payments received in the last five years i.e. 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25 as per sub clause 1.2 of section 3 of standard bid document (as per relevant table). Enclose the certificate from chartered accountant with chartered accountant UDIN number.
Maximum of Civil Engineering works executed in any one year during the last five years (updated to 2025-26 price level) taking into account the completed as well as works in progress. (Financial turnover of previous years shall be given a weight of 10% per year to bring them to the price level of the 2025-26)
Each tenderer should further demonstrate liquid assets and / or availability of Credit facilities of Rs. 67,85,180.00 amount put to tender (Credit lines / letter of credit / certificates from banks) for meeting the fund requirement etc, shall be enclosed as per the format under KW manual section 1.10 of section-3 of standard bid document. The format / information shall be as per certificate mentioned in the standard bid document.
To qualify for award of this contract, each Tenderer / agency in its name should have in the last five years i.e. 2020-21, 2021-22, 2022-23, 2023-24 and 2024-25 achieved in at least two financial years, turnover equal to Rs.3,83,34,348.00for each individual work (In all classes of civil engineering construction works). In support of this claim, he has to provide year wise turnover certificate of duly certified by the Chartered Accountant with chartered accountant UDIN number as per sub clause 3.2. (a) of section 2 of standard bid document
Tax Paid Details for last 3 years.
Technical specifications / information / Literature / Brochure shall be enclosed.
Bidder has to clearly mentioned Brand, Country of origin, Make & Model.
The proposed methodology and program of construction, backed with equipment planning and deployment, duly supported with broad calculations and quality control procedures proposed to be adopted, justifying their capability of execution and completion of the work as per technical specifications within the stipulated period of completion as per milestones
Tenderer shall quote their rates in given excel format only and upload the same excel file copy (The agency please note the rates quoted shall inclusive of GST for both Civil and Machineries, installation etc.,)
₹500
₹14.4 L
11 Jun 2026
11 Jun 2026
13 Jul 2026
20 Jun 2026
23 Jun 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungle
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20 percent E.C. or Lindane 20 percent E.C. at 3.19 l or m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates a) Level 1 (Upto 3.5m Level)
Providing and laying in position Cement Concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Shuttering work for Isolated Footing at 8 percent
Shuttering work for Combined Footing at 3 percent
Shuttering work for Pedestrals at 70 percent
Shuttering work for Columns Upto Plinth Beam at 70 percent
Shuttering work for Plinth Beam at 50 percent
Providing and laying in Cement Concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates
Shuttering work for Wall at 10 percent
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates a) Level 1 (Upto 3.5m Level)
Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates b) Level 2 (From 3.5m to 5.0m Level)
Columns at 70 percent - a) Level 1 (Upto 3.5m Level)
Columns at 70 percent- b) Level 2 (From 3.5m to 5.0m Level)
Roof Beam, Lintel Beam at 60 percent- a) Level 1 (Upto 3.5m Level)
Roof Beam, Lintel Beam at 60 percent- b) Level 2 (From 3.5m to 5.0m Level)
Roof Slab at 50 percent- a) Level 1 (Upto 3.5m Level)
Chajja at 45 percent a) Level 1 (Upto 3.5m Level)
Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Level 1 (Upto 3.5m Level)
Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. b) Level 2 (From 3.5m to 5.0m Level)
Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing Flush or Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620 or 1979 having compressive strength not less than 3.5 N or mm2 for saturated dry samples - For Super structure in CM 1:6. a) Level 1 (Upto 3.5m Level)
Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620 or 1979 having compressive strength not less than 3.5 N or mm2 for saturated dry samples - For Super structure in CM 1:6. b) Level 2
Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. a) Level 1 (Upto 3.5m Level)
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings or wooden frames with rawl plugs screws etc. a) Level 1 (Upto 3.5m Level)
Providing and fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm-2.5mm. Maximum possible size – 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made) a) Level 1 (Upto 3.5m Level)
Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size – 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made) a) Level 1 (Upto 3.5m Level)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. a) Level 1 (Upto 3.5m Level)
Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. a) Level 1 (Upto 3.5m Level)
Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 m² and upto 16.80 m² in the area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineer-in- Charge. a) Level 1 (Upto 3.5m Level)
Extra for providing Manually operated Bevel Gear Box for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. a) Level 1 (Upto 3.5m Level)
Providing and fixing corrugated G.S. sheet roofing including vertical or curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal or vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g or m² b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g or m² b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 percent) total coated thickness, Zinc coating 120 g or m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling or self tapping screws complete : Flashings or Aprons ( Upto 600 mm) b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g or m²) b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 1.3mm thickness and 38 No.s of Vanes and turbine doom thickness 1mm and total weight not less than 6kg for Industrial use for area upto 100m2 for Industrial use b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing Steel work welded in built up sections or framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.
Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. a) Level 1 (Upto 3.5m Level)
Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification. -do- 35 mm thick both side teak a) Level 1 (Upto 3.5m Level)
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door or window or Clerestory windows and other Frames or Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder or rice husk or wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg or m3, screw withdrawal strength of 2200 N (Face) and 1100 N (Edge), minimum compressive strength of 58 N or mm2 , modulus of elasticity 900 N or mm2 and resistance to spread of flame of Class A category with property of being termite or borer proof, water or moisture proof and fire retardant and fixed in position with M.S hold fast or lugs or SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 100mm a) Level 1 (Upto 3.5m Level)
Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder or rice husk or wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg or m3 and screw withdrawal strength of 1800 N (Face) and 900 N (Edge), minimum compressive strength of 50 N or mm2 , modulus of elasticity 850 N or mm2 and resistance to spread of flame of Class A category with property of being termite or borer proof, water or moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness a) Level 1 (Upto 3.5m Level)
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. a) Level 1 (Upto 3.5m Level)
Providing and fixing Float glass panes of nominal thickness 5 mm (weight not less than 12.50 kg or m2) a) Level 1 (Upto 3.5m Level)
Providing and fixing PVC Edge beading a) Level 1 (Upto 3.5m Level)
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 300mm a) Level 1 (Upto 3.5m Level)
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Handles 200mm a) Level 1 (Upto 3.5m Level)
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Door stopper 75mm a) Level 1 (Upto 3.5m Level)
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm a) Level 1 (Upto 3.5m Level)
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 200x10mm a) Level 1 (Upto 3.5m Level)
Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm a) Level 1 (Upto 3.5m Level)
Providing and Fixing Holdfast of size 260mm x 25mm x 5mm a) Level 1 (Upto 3.5m Level)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing,curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. a) Level 1 (Upto 3.5m Level)
Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume,hardening compound mixed at 2 L per 50 kg of cement or as per direction of Engineer incharge. a) Level 1 (Upto 3.5m Level)
Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement. 15 mm thick a) Level 1 (Upto 3.5m Level)
Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry at 3.3 kg or m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600x600 mm a) Level 1 (Upto 3.5m Level)
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry at 3.3 kg or m2 including pointing the joints with white cement and matching pigment etc., complete. a) Level 1 (Upto 3.5m Level)
Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. a) Level 1 (Upto 3.5m Level)
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering a) Level 1 (Upto 3.5m Level)
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering b) Level 2 (From 3.5m to 5.0m Level)
Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering a) Level 1 (Upto 3.5m Level)
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering a) Level 1 (Upto 3.5m Level)
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering b) Level 2 (From 3.5m to 5.0m Level)
Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g or m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide a) Level 1 (Upto 3.5m Level)
Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g or m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide b) Level 2 (From 3.5m to 5.0m Level)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Level 1 (Upto 3.5m Level)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. b) Level 2 (From 3.5m to 5.0m Level)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams or litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams or litre as per specifications and as per directions of Engineer in charge. a) Level 1 (Upto 3.5m Level)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams or litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams or litre as per specifications and as per directions of Engineer in charge. b) Level 2 (From 3.5m to 5.0m Level)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt and pick up resistant, Alkali and Water resistant of required shade: New work (Two coats applied at 1.43 L or 10 m² over and including priming coat of exterior primer applied at 2.20 kg or 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Level 1 (Upto 3.5m Level)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt and pick up resistant, Alkali and Water resistant of required shade: New work (Two coats applied at 1.43 L or 10 m² over and including priming coat of exterior primer applied at 2.20 kg or 10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) Level 2 (From 3.5m to 5.0m Level)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied at 0.90 ltr or 10 m² over an under coat of primer applied at 0.75 ltr or 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Level 1 (Upto 3.5m Level)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Level 1 (Upto 3.5m Level)
GYPSUM CEILING Providing and fixing Gypsum false ceiling as per India Gypsum specification for ceiling with drops as per drawing including of providing and fixing Aluminium Frame work as per specification of India gypsum at a distance of 2'0" clc both ways complete with 12.5mm board (IS-2095-1982) had all necessary perimeter channels etc. No extra payment will be made for the cutting of light points, stain glass, cove lighting etc. The measurement will be taken in one level , rate should include the drops also. no extra amount will be paid for the drops. The joints to be properly mended with paper tapes and gypsum compound all complete . The rate should include the full completion of the ceiling. At the time of handing over the site all necessary repairing work to be considered if required. The work to be completed as per specification ,design and approval of the Architect . a) Level 1 (Upto 3.5m Level)
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising at 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls or partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws at 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting or making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. a) Level 1 (Upto 3.5m Level)
RCC D.P structure using 9 mtrs RCC Pole with WL 145 kg
11 kV, 45 KN Polymeric Insulator
NO 15 strain insulator
Caution danger board
11 kV 200 A Single Break GOS
H Frame for mounting GOS
Spiral earth electrode
DOLO Cut Out
11 kV, Solid Core HG Fuse Unit
Lightning Arrester 10 kV, 5 kA Polymeric Type with Ground disconnector
11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)
Errection of 9Mtrs Long RCC DP Structure
Fixing of Guy set with Break insulators, turn buckle and anchor rod
Fixing danger board
fixing of GOS including wiring (11 kV Single Break 200 Amps)
Errection of H Frame for mounting GOS
Fixing of Spiral earth electrode
Fixing of DOLO Cutouts
Providing concrete cement to poles with materials and labour cost including curing etc. a) Base concreting 1:4:8, 650x650x150mm. Supply and installation:
b) Pole conctreting 1:2:4, 650x650x1700mm Supply and installation:
c) Providing coping for poles with 1:2:4 and as per actuals, 150mm around pole for an height of 300mm Supply and installation:
Supply and making of 11KV (E) Extruded "X" linked for tubing and moulded and cross-linked components using Heat Shrink Stress Control tube having High Permitivity XLPE Terminations - INDOOR and OUTDOOR JOINTING KIT latest amendments. OUTDOOR TYPE 3Cx95 Sqmm
Supply and making of 11KV (E) Extruded "X" linked for tubing and moulded and cross-linked components using Heat Shrink Stress Control tube having High Permitivity XLPE Terminations - INDOOR and OUTDOOR JOINTING KIT latest amendments. INDOOR TYPE 3Cx95 Sqmm
Supply of HT Cable 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 3Cx95sqmm
Labour charges for laying of 11 KV class UG cable in the existing trench GI pipe or stoneware pipe or on wall or on pole as required. On wall or Structure. 3Cx95sqmm
Supply, erection, testing and commissioning of........ KVA 5Star rated aluminum or copper wound Distribution Transformer 11KV or 433V with Off circuit Tap change over Switch , Buchholtz relay winding temperature indicator, oil temperature indicator, marshelling box with wiring, oil level indicator with +5 percent to -15 percent steps of 1.25 percent, HT and LT Cable box, stacked core with oil as per IS:1180 (part-1) : 2022 with all standard accessories as per latest IS standard no.2026 or 1977 and IS :335, technical spcification and ESCOM approved. a) 63KVA Aluminium Wound
Construction of platform with size stone, cement concrete for errection of 250 upto 500 kVA Transformer or HT panels or Heavy Equipment. Construction of platform (1.5x1.5x1.2 ) mtr in size stone, for errection of transformers or Heavy Equipment including all materials, labour, excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint and nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.
Chain link fencing - Providing chain link fencing 50mm size of 8 guage properly stretched between rectangular poles and fixed with suitable bolts and nuts, the free ends shall be welded to the pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. Providing and laying in position plain cement concrete of mix 1:3:6 for poles. The rate shall included all rectangular poles, height 2.8 mtrs fixed at a distance of 2 mtrs welded together, etc. with chain link matching gate of 1.5 mtrs wide with hinged and locking arrangements.
Jelly Spreading (20-25 mm) : Supplying and providing jelly in the station yard of uniform thickness of 100 mm including the cost of materials, labour charges, required tools and plants etc., complete. Work shall be carried out as per the instructions of Engineerin-charge of works as per the standard procedure.
LT ELECTRICAL WORKS PVC CONDUITS and ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19 or 20 mm dia 2mm thick
Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick
Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. c) 32mm dia 2.5mm thick
Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. d) 40mm dia 2.5mm thick
Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals or PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19 or 20 mm dia 2mm thick
Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals or PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick
Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals or PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. c) 32mm dia 2.5mm thick
Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals or PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. d) 40mm dia 2.5mm thick
Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19 or 20 mm dia 2mm thick
Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick
Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thick
Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary d) 40mm dia 2.5mm thick
Supplying and fixing PVC or metal conduit deep junction box. a) 19 or 20mm deep junction box
Supplying and fixing PVC or metal conduit deep junction box. b) 25mm deep junction box
Supplying and fixing PVC or metal conduit deep junction box. c) 32mm deep junction box
Extra for Groove cutting in brick wall or cc floor to the suitable depth for concealing of Conduit or GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor
Supplying and fixing Metal fan box with round hook.
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit or casing capping using 2x1.5Sqmm (Phase and Neutral) and 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet or gland box, the other end of the wires shall be terminated with sufficient loose length in a wood or PVC round block complete for each outlet. (For light and fan point) a) Short point up to 3Mtr from tapping point to out let via switch box
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit or casing capping using 2x1.5Sqmm (Phase and Neutral) and 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet or gland box, the other end of the wires shall be terminated with sufficient loose length in a wood or PVC round block complete for each outlet. (For light and fan point) b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit or casing capping using 2x1.5Sqmm (Phase and Neutral) and 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet or gland box, the other end of the wires shall be terminated with sufficient loose length in a wood or PVC round block complete for each outlet. (For light and fan point) c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit or casing capping using 2x1.5Sqmm (Phase and Neutral) and 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet or gland box, the other end of the wires shall be terminated with sufficient loose length in a wood or PVC round block complete for each outlet. (For light and fan point) d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit or casing capping using 2x1.5Sqmm (Phase and Neutral) and 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet or gland box, the other end of the wires shall be terminated with sufficient loose length in a wood or PVC round block complete for each outlet. (For light and fan point) e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) a) 1.0 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) b) 1.5 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) c) 2.5 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) d) 4 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) e) 6 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) f) 10 sqmm
Wiring for lighting or power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. (Lihgitng, Raw Power, UPS, AC citcuits) g) 16 sqmm
Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 3Cx4.0Sqmm
Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. b) 5Cx4.0Sqmm
Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. c) 4Cx6.0Sqmm
SWITCHES, SOCKETS and ACCESSORIES Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall a) 1-2 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall b) 3 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall c) 4 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall d) 6 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall e) 8 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall f) 16 Way
Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick or Stone or C.C wall g) 18 Way
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. a) 1 to 2 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. b) 3 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. c) 4 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. d) 6 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. e) 8 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. f) 16 Module
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal or metal PVC box. g)18 Module
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,Switch
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switch
Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 g) 6 or 16Amps universal socket
CONTROL SWITCH GEARS and ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400 or 440 volts 3 phase motor or single phase motor upto 5 HP.
Supplying and fixing regular MCCB distribution Panel confirming to IS or IEC61439-3 and IK09 tested as per IS or IEC62262 with minimum IP43 protection provided with Polyurethane(PUR)gasket, with suitable earthing system, on wall or woodboard or flushmounting using required clA,bolts,nuts,etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single or three phase suitable capacity MCB's as outgoings confirming to IS or IEC 60898 - 2. 8 way
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6-32Amps SP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 6-32Amps DP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 6-32Amps TP or TPN
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPN
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. e) 63Amps TPN
Supplying and fixing regular MCB distribution boards on wall or wood board or flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase or 3 phase or single door with powder coated painting. Made out of 14 SWG MS Enclosure. a) Double Door 4 Way SP and N
Supplying and fixing regular MCB distribution boards on wall or wood board or flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase or 3 phase or single door with powder coated painting. Made out of 14 SWG MS Enclosure b) Double Door 16 Way SP and N
Supplying and fixing regular MCB distribution boards on wall or wood board or flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase or 3 phase or single door with powder coated painting. Made out of 14 SWG MS Enclosure c) Double Door 4 Way TP and N
Supplying, fixing and wiring Residual Current Circuit Breaker [RCCB] 240 or 450V up to 300mA sensitivity on existing wood or panel Board. a) 32-40Amps 2 pole
Supplying, fixing and wiring Residual Current Circuit Breaker [RCCB] 240 or 450V up to 300mA sensitivity on existing wood or panel Board. b) 32-40Amps 4 pole
Supplying, fixing and wiring Residual Current Circuit Breaker [RCCB] 240 or 450V up to 300mA sensitivity on existing wood or panel Board. c) 63Amps 4 pole
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6
Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic or powder coated metal box and wired completely. SP and N 20Amps
Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic or powder coated metal box and wired completely. TP and N 20Amps
Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic or powder coated metal box and wired completely. TP and N 30Amps
Supply and fixing of metal clad industrial plugs and sockets. 2Pole + earth 250v Plug 16 Amps
Supply and fixing of metal clad industrial plugs and sockets. 3Pole + earth 440v Plug 16 Amps
Supply and fixing of metal clad industrial plugs and sockets. 3Pole + earth 440v Plug 32 Amps
Supply and fixing of metal clad industrial plugs and sockets. 2Pole + earth 250v Socket 16 Amps
Supply and fixing of metal clad industrial plugs and sockets. 3Pole + earth 440v Socket 16 Amps
Supply and fixing of metal clad industrial plugs and sockets. 3Pole + earth 440v Socket 32 Amps
L.T. U.G. CABLES AND EARTHING Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
Supplying and running of GI or Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm
Supplying and running of GI or Copper strips for grounding connections, using necessary fixing materials as required. b) GI strip 25x6mm
Supplying and running of GI or Copper strips for grounding connections, using necessary fixing materials as required. c) CU strip 25x3mm
Supplying and running of GI or Copper strips for grounding connections, using necessary fixing materials as required. d) 600x600x3mm GI Plate
Supplying and running of GI or Copper strips for grounding connections, using necessary fixing materials as required. e) 600x600x3mm CU Plate
Supplying, Fixing and proper termination of vertical Air-termination using Gunmetal ball with finials of 5 spikes mounted on 2 mtrs long copper rod, mounted at the highest point of the building, with base plates, connection with horizontal conductor, necessary civil works, etc.
Supply and fixing Test Link as per specification and drgs. and grouted to wall at 1200 mm. above ground level complete with all fixing accessories, clamps, screws etc, enclosed in M.S box.
Supplying and Fixing Chemical earthing for grounding, conduits, IC cut outs and other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm. Using 10 ft copper bonded rod with backfill compound
Supplying and running GI or Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas or spacers etc.. 8 SWG GI wire.
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 a) 2 core 10 sq.mm
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 b) 4 core 10 sq.mm
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 c) 4 core 16 sq.mm
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 d) 3.5 core 25 sq.mm
Supplying of 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 e) 3.5 core 50 sq.mm
Laying of cable in Existing Trench or GI pipe or Stone Ware or RCC Hume pipe using Wooden or Aluminum Rollers as directed by the departmental staff. a) 2.5 sqmm to 25 sqmm
Laying of cable in Existing Trench or GI pipe or Stone Ware or RCC Hume pipe using Wooden or Aluminum Rollers as directed by the departmental staff. b) 35 sqmm to 95 sqmm
Laying of cable in Existing Trench or GI pipe or Stone Ware or RCC Hume pipe using Wooden or Aluminum Rollers as directed by the departmental staff. c) 120 sqmm to 240 sqmm
Supplying and fixing of Brass Cable Gland a) 25mm
Supplying and fixing of Brass Cable Gland b) 32mm
Supplying and fixing of Brass Cable Gland c) 45mm
Supply and laying of underfloor (concealed) or Above false ceiling raceways manufactured from 1.5 mm thick cover and base (including partitions for multicompartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2. 100 x 38 x 2500mm, 1 compartment
Supply and laying of underfloor (concealed) or Above false ceiling raceways manufactured from 1.5 mm thick cover and base (including partitions for multicompartment raceways), zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 50085-2-2. 150 x 38 x 2500mm, 1 compartment
upply and laying of under floor junction boxes shall be of three-piece construction – Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile or Carpet or marble or granite or according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways. For (50-100x38mm) duct.Dimensions:172x172x60mm. 10 mm Recess
Supply and laying of under floor junction boxes shall be of three-piece construction – Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre-galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 50085-2-2. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile or Carpet or marble or granite or according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have pre-punched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways. For (50-200x38mm) duct.Dimensions:272x272x60mm. 10 mm Recess
Supply, termination of Aluminium End Terminal (Lug) a) 1.5 to 10 sq.mm
Supply, termination of Aluminium End Terminal (Lug) b) 16 sq.mm
Supply, termination of Heavy Duty Copper Terminal Long Barrel a) 25 sq.mm Long barrel
Supply, termination of Heavy Duty Copper Terminal Long Barrel b) 50 sq.mm Long barrel
Supply, termination of Heavy Duty Copper Terminal Long Barrel c) 120 sq.mm Long barrel
FIXING CHARGES Fixing charges of Post top or gate or garden fitting or LED on the existing CI or GI or any other pipe using required size of reducer, wiring using suitable wires.
Fixing all types and all capacities fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23 or 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall or ceiling or Rafters or Girders
Fixing a ceiling or wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 or 0.0076 inch PVC insulated twin twisted copper wire and wiring.
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire.
Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel painted.
Extra length of GI pipe of class b 19mm dia for down rod.
LED LUMINAIRS or LIGHT FIXTURES and ACCESSORIES AND FANS Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications
Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 8. Power Input : 220-240V at 50 Hz and power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 or 10 watts
Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 8. Power Input : 220-240V at 50 Hz and power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 or 22 watts
Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 8. Power Input : 220-240V at 50 Hz and power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. c) Led light fitting 4' - 36 or 40 watts
Supply of round or square recess or surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 80. Power Input: 220-240V at 50 or 60Hz and Power factor More than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition. 6W
Supply of round or square recess or surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 80. Power Input: 220-240V at 50 or 60Hz and Power factor More than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition 10-12W
Supply of round or square recess or surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI More than 80. Power Input: 220-240V at 50 or 60Hz and Power factor More than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition 15-18W
FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374 or 79 and also comply with IS:1709 or 1984 with latest amendment, Rated voltage 220 V or 50 Hz, Rated power input 48 W + or - 10 percent, Rated current As per IS:374 or 79, Rated power factor 0.9 lagging(min), Rated speed 350 + or - 10 percent RPM, Rated air delivery 210 + or - 10 percent Cubic Meter Minimum, Rated service value ≥ 4.2 CMM or Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt and current , Air Delivery and Fan Speed as per IS:374 or 1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48" Sweep 5 Star (1200mm)
Supplying wall mounting fan suitable to operate at single phase 230v AC supply. 400mm Sweep
Supply of LED Street light with pressure die cast aluminum housing body with optimal heat sink for better thermal dissipation. Diffuser with injection moulded and is made of polycarbonate material with high transmission index, delivering supirior light output. Rated life burning Hrs 50000 hr at lumen maintainence of 70 percent. CCT More than 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire More than IK08. Power Factor More than 0.9 with mains current should not be greater than 0.1A to 0.7A and surge protection - min 4KV along with over voltage or overload, short circuit or mis wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal voltage driver to operate wide range from 100v to 270V 50 or 60Hz application. Overload and short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322 or IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to enxsure ease of maintainence at the sight site location with minimized minimal tools. LED Light fixture with .........W system power consumption. LEd efficiency More than 130ml or w at 1w and fixture efficiency More than 75ml or w with CRI More than 75. luminaire Manufacturer should have inhouse facility accredited by NABL or CPRI and any government certified agency and design and development facility certified by ISO 9001:2008. Housing with supplier word mark or name shall be engraved or embassing on the die cast housing or body part. 2 years warranty against any manufacturing defect working under standard electrical condition as mentioined above should be given by LED source manufacture. Suitable for B1 or B2 roads as per IS 1944 Part 1 and Part II. b) LED Street light 70W
LT PANEL WORKS: Design, manufacture, supplying, fixing in position, testing and commissioning of following MV switchgear panels made up of 14G, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification. Fabricating supplying and mounting MS box made out … SWG suitable for floor or wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating. etc., complete. 14SWG
Fabricating supplying and mounting MS box made out … SWG suitable for floor or wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating. etc., complete. 16SWG
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat …….. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mm
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat …….. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 150 x 75 x 6 mm C channel
Supply of on load change over switches 4 poles, AC-23A duty, 415v, 50Hz, AC supply. (Open Execution) 200Amps
Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood or panel board using necessary screws, bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnetic or micro processor releases and earth fault as per IS-13947. (Icu equals toIcs). In 4P MCCB, all poles should have protection for short -circuit or over load. For Microprocessor MCCBS Facility for segregating priority and Non -Priority load must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE POLE 63-100Amps 25kA
Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood or panel board using necessary screws, bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnetic or micro processor releases and earth fault as per IS-13947. (Icu equals toIcs). In 4P MCCB, all poles should have protection for short -circuit or over load. For Microprocessor MCCBS Facility for segregating priority and Non -Priority load must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 160Amps 25kA
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12 or 24V DC.
Supplying, fixing and wiring 3 phase Digit Digital Ammeter or Voltmeter
Supplying, fixing and wiring 50 or 5A to 400 or 5A 5VA burden current transformer class 0.5 accuracy with Tape wound
Supplying of multi function Meter digital three line back light LCD type display of voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required wit communication Port and class 0.5s accuracy.
Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic or FRP or DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips.
Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic or FRP or DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips.
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps SP
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps TPN
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 40 Amps TPN
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON or OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 50-63 Amps TPN
Supply and fixing of 4 pole contactor with No or NC contacts on existing wood or panel board using necessary bolts, nitsm washers and wiring etc, complete with AC-3 rating and as per IS- 13947 25Amps
Supplying, fixing and wiring heavy duty low voltage capacitors confirming to IS 2834. 3 phase, 400 or 440 volts grade, for power factor improvement of rotating machinery.
Supplying, fixing and wiring Automatic Power Factor controller fully, static units controilled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, comprehensive displays with large, three place LED display, long term memory for settings, protection for over voltage, power facor correction fault and no voltage, to connect or disconnect banks, with automatic recognition or with standard programs.
NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch or Socket or stepped electronic fan regulator or dimmer or telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. b) RJ45 or I.O. outlet Cat -6 (For data and voice)
Supplying and drawing UTP-CAT 6 LAN cable.
Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 5 Pair
Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. b) 20 Pair
Supplying and fixing of switch mounting rack with power manager and cable manager. 6U with 450mm depth
Supplying and fixing of power strip.
Supplying and fixing of fan.
Supplying fixing of Network Switches. 24 Port Gigabyte (Manageable)
Supplying and fixing of ….mtrs Cat6 Patch Cable - a) 1 mtr
Supplying and fixing of Patch Panel for LAN cabling. 24 Port 10 or 100 or 1000 Patch Panel
Supplying and Fixing of MDF Krone junction box with KRONE module or Telephone cable termination. 20 pair
Supply and laying 6 Core Multimode OM3 outdoor Fiber Cable.
Supply and providing 12F, 1U, LC MM OM3, Loaded with Pigtails, Splice tray, adapter and splice protectors
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid a) Ground Floor
Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40mm Dia
Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark and with its latest amendments
Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark and with its latest amendments
Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Providing and fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..
Supplying and fixing PVC `P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.
Providing and Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.
Providing and grouting sleeves made in beam or slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes
25 mm dia pipe nominal OD pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25mm nominal bore
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete As per direction of engineer in charge (external work) 20 mm dia pipe nominal OD pipes
25 mm dia pipe nominal OD pipes
32 mm dia pipe nominal OD pipes
40 mm dia pipe nominal OD pipes
50 mm dia pipe nominal OD pipes
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal bore
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25mm nominal bore
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32mm nominal bore
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40mm nominal bore
Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50mm nominal bore
Providing and placing on terrace, polyethylene water storage tanks As per IS 12701 Marked with cover and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes But with out fittings and the base support for the tank
Supplying and fixing suction `Y' or pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia
Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark and with its latest amendments
Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark and with its latest amendments
Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark and with its latest amendments
Supply and delivery at site special moulded variety 160mm dia PVC elbows as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834 or 1987 and fabricated as per IG124 or 1984 with ISI mark with its latest amendments
Providing And fixing Square mouth stone ware gully trap SP-1 Complete With CI Grating Brick Masonry Chamber 100x100mm Size P trap With Non modular common burnt bricks of designation 3.5, with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 KG, and frame to be not less than 2.70Kg as per the standard design
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5
DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible or Mono blockelectrical driven pump 1set . (1 working and standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O or L relays, single phase preventor,separate overload trip and relayset, ON or OFF or TRIP indicating lamps,start or stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar or suguna or texmo or CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes or sensors.
Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal bore Vertical
Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore Vertical
Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement and making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm and depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.
Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. a) 32 mm dia
Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. b) 40 mm dia
Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. c) 50 mm dia
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Addtionalities for Form Work for combined Footing at 8 percent
Addtionalities for Form Work for retaining wall at 10 percent
Addtionalities for Form Work for Slab at 50 percent
Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt Floor
UGT or OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied at 0.35 Kg or m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g or m2 or 24 hrs, as per IS 7809 or Pt 2 or 1977, Adhesion strength: 2 N or mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates
Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances complete Heavy Duty
Providing and fixing of PVC Rungs footrest in under ground tanks or manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Addtionalities for Form Work for Combined Footing at 3 percent
Addtionalities for Form Work for Wall at 10 percent
Addtionalities for Form Work for Roof Beam, Lintel Beam at 60 percent
Addtionalities for Form Work for Roof Slab at 50 percent
Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt Floor
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering
Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50 percent applied at 1.5 kg or m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.
Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances complete Heavy Duty
Providing and fixing of PVC Rungs footrest in under ground tanks or manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates
Concrete, Formwork and reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Addtionalities for Form Work for Combined Footing at 3 percent
Addtionalities for Form Work for Wall at 10 percent
Addtionalities for Form Work for Roof Beam, Lintel Beam at 60 percent
Addtionalities for Form Work for Roof Slab at 50 percent
Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt Floor
Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.
Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading andleveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineerin- charge.
Supplying, filling, spreading andleveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge.
Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering
Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50 percent applied at 1.5 kg or m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.
Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.Providing and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances complete Heavy Duty
Providing and fixing of PVC Rungs footrest in under ground tanks or manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.
Providing, Supplying, Installing and Commissioning of Modular Effluent treatment plant of 5 KLD capacity consisting of the following Components, 1. BAR SCREEN CHAMBER Purpose : For Retaining Coarse Material Like Rags,Plastics Etc. Quantity : 1No Location : At starting of ETP Max. Flow : 0.5 m³ or hour Material : MSEP 2. BAR SCREEN Purpose : Screening of floatable matter Quantity : 1No Location : At inlet of Screen Chamber Max. Flow : 0.5 m³ or hour Size of spacing : 20 mm or 10 mm Material : SS Screen 3. OIL AND GREASE TANK Purpose : To remove oil and grease from effluent i.e., floatable matter Quantity : 1No Location : After screen chamber Size : 0.5 m³ or hour Material : MSEP 4. REACTION TANK Purpose : Coagulation, Flocculation and Settler tank Quantity : 1No Location : After collection tank Size : 2.6 m³ Material : MSEP 5. FILTER FEED TANK Purpose : To store treated water for passing through DMF Quantity : 1No Location : After reaction tank Size : 2 m³ Material : MSEP 6. SLUDGE DRYING BED Purpose : For Collecting sludge from the process Quantity : 1No Location : After reaction tank Size : 0.4 m³ Material : MSEP 7. DOSING TANK Purpose : For storage of Chemical solution Quantity : 3Nos Location : Near the reaction Tank Capacity : 50 L Material : HDPE 8. AIR BLOWER Purpose : To provide air for mixing Quantity : 2Nos Location : Near the reaction Tank Capacity : 10 m3 or hour Type: Ring 9. EFFLUENT TRANSFER PUMP Purpose : To feed effluent to next tank Quantity : 2Nos. (1W+1S) Location : Collection Tank Size: Centrifugal Capacity : 0.5 m3 or hour Make : Kirloskar or Crompton or Equivalent 10. FILTER FEED PUMP Purpose : To feed effluent to Filter Quantity : 2Nos. (1W+1S) Location : Filter feed Tank Capacity : 0.5 m3 or hr. Type: Monoblock Make : Kirloskar or Crompton or Equivalent 11.MULTIGRADE FILTER Location :After a Filter Feed Pump Quantity : 1 No Type: Vertical Size : Diameter 325 mm x Height 1350 mm Working flow : 0.5 m³ or hour Backwash duration : 15-20 minutes daily Filter Media : Quartz sand with pebbles, gravels Make: Pentair or Starlite or Kai or Sea flow or Alfa or Equ. 12. ACTIVATED CARBON FILTER Location :After Multigrade Filter Quantity : 1No Type: Vertical Size : Diameter 325 mm x Height 1350 mm Working flow : 0.5 m³ or hour Backwash duration : 15-20 minutes daily Filter Media: Quartz sand with pebbles, gravels and Activated Carbon Make : Pentair or Starlite or Kai or Sea flow or Alfa or Equ 13. MULTIPORT VALVE Location: On the MGF and ACF vessel Quantity : 2No Purpose: To direct the flow of water Size : 25 NB Type: Side Mount Front Facing Make :UKL or Initiative or Equivalent 14. CARBON AND MEDIA Location In MGF and ACF Vessels Quantity : 1 LOT Purpose : For removing and retaining dust, heavy particles, odor and color. Contents : Quartz sand, Pebbles, gravels and Activated Carbon. 15. COARSE BUBBLE AIR DIFFUSERS Location : Inside tanks Purpose : To provide air for Equalization Quantity : 1 LOT Type :Disc Size: 80 mm Material : EPDM Make : Kelvin 16. AERATION GRID Location : In collection tanks and reaction tank Purpose : For Aeration Quantity : 1 LOT Material : UPVC with MSEP header Make : Ashirwad or Prince or Supreme or Tata or Jindal or CK Birla or Equivalent Accessories : Complete with piping, valves, and other fittings such as tees crosses, plugs, sockets, elbows, reducers, supports and clamps etc. DETAIL OF ELECTRICAL WORKS 1. CABLING Description : Electrical cabling shall be provided underground from control panel to various units of effluent treatment plant Quantity : 1 Lot Application : For supplying electricity to electromechanical parts Size of cable : As per the capacity of the motors or drives Material : Copper Make : CCI or Polycab or Finolex or Equivalent 2. CONTROL PANEL. Location : MCC Application : For Supplying electricity to electromechanical parts Quantity : 1No Description : Control panel will be industrial cubical type, with noncompartment, dust and vermin proof, wall mounted. One incoming feeder will be provided which will have amp meter, voltmeter, indicating lamps and energy meter. Outgoing feeders will be as per drives of mechanical equipment. Outgoing feeder shall have contactor, overload relay, on or off push button, indicating lamp, neutral link and one set of terminal block. Panel will be epoxy coated. Make of switchgears : L andT or Siemens or Equivalent DETAIL OF OTHER PARTS AND INSTRUMENTS 1. Pressure Gauges Quantity : 1 Lot Location: Delivery line of Pump and Blower wherever needed Application: To Indicate the Pressure Type: Bourdon or Diaphragm Range : 0 to 7 Kg or cm2 Make : Wika or H guru or Equivalent 2. Water Meter Location : Mechanical water meter at outlet pipe line Quantity : 1No Application : For Measuring quantity of treated water Make : Magflow or equivalent DETAIL OF INTERCONNECTING PIPING Quantity : 1 LOT Description : Supply of interconnecting piping, fitting and valves for ETP units Material : UPVC Make: Ashirwad or Prince or Supreme or Tata or Jindal or CK Birla or Equivalent Pressure : at 10 kg pressure The plant to be provided 30 m away from incubation centre as per the site condition, the cost includes materials mentioned above, installation and transportation, Pipe line works and electrical works related to plant, complete as per instructions of engineer in charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed or plain ended casing pipes of required dia, conforming to IS: 4270,of reputed and approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings and accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm
Providing to work spot rolling, lowering and placing in position RCC perforated rings in the already excavated pit including loading and unloading at both the destinations with all lead and lift with appurtenances., complete. 1200 mmx1250 mm
Providing and laying 100mm thick pre-cast cover slabs over Road side drains or utility ducts or Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 at 6kg or m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.
Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading andleveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineerin- charge.
Supplying, filling, spreading andleveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer -in-charge.
Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine or medium or coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineerin- charge.
TOTAL AMOUNT
Add 18% GST
GRAND TOTAL AMOUNT
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid document-kw4.doc
Others - KW-4 Manual for Civil Works • 2.80 MB
MDP.pdf
Others - MDP Govt. Circular • 2.15 MB
KG Documents.docx
Others - KG document for Goods • 0.12 MB
Notification TN-222 final.docx
Others - Notification • 0.27 MB
Equipments etc specification.pdf
Others - Equipments, Machineries etc., specification • 1.11 MB
Drawings.pdf
Others - Drawing for Civil Works • 2.17 MB
Tender BOQ - Incubation centre at Bidar_ UHS - 04-3-26.xlsx
Others - Estimate for Civil Works • 0.72 MB
Download all tender documents and submit your bid