| Sl No | Description | Qty | Unit | SACKSON ENTERPRISES L1 | BHARAT MULTITECH INDUSTRIES PVT LTD L2 | kakolil trade agencies L3 | CITY CONSTRUCTION COMPANYU L4 | M/s V M K Construction L5 | NAWAZ CONSTRUCTIONS L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed. | 1,123 | SQUARE METRE | - | - | - | - | - | - |
| 2.00 | Rough excavation not exceeding 1.5 m deep and getting out in any type of soil all as specified and directed. | 300 | CUBIC METRE | - | - | - | - | - | - |
| 3.00 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil all as specified and directed. | 123.1 | CUBIC METRE | - | - | - | - | - | - |
| 4.00 | Excavating over areas, exc 1.5 m and not exc 3.0m deep and getting out in hard/dense soil all as specified and directed. | 2.6 | CUBIC METRE | - | - | - | - | - | - |
| 5.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed. | 33.5 | CUBIC METRE | - | - | - | - | - | - |
| 6.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil all as specified and directed. | 210.8 | CUBIC METRE | - | - | - | - | - | - |
| 7.00 | Excavating in trenches, not exceeding 1.5 m wide and depth exceeding 1.5 m but not exceeding 3.0m ; for foundations, laying of pipe and cables etc or for shafts, well cess pits, manholes,pier holes not exceeding 10 sqm on plan, including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in any type of soil complete all as specified. | 21 | CUBIC METRE | - | - | - | - | - | - |
| 8.00 | Returning and filling in including spreading levelling watering and well ramming in layer n.exc 25 cm using soil obtained from excavation all as specified and directed. | 445 | CUBIC METRE | - | - | - | - | - | - |
| 9.00 | Sand filling (River sand from mainland)under floors or in foundations including watering and consolidation all as specified and directed. | 7.5 | CUBIC METRE | - | - | - | - | - | - |
| 10.00 | Removing of excavated material to a distance exc.50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed. | 539.2 | CUBIC METRE | - | - | - | - | - | - |
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
25 Jun 2020, 6:00 pmClosed
CWE No 2 Port Blair
HQ Commander Works Engineer No.2, Brichgunj, Junglighat Post, Port Blair - 744 103
PROVN OF DOUBLE STOREY PORTA CABIN WITH TOILET AT INS KOHASSA UNDER GE(SOUTH) DIGLIPUR
2020_MES_345394_1
80176/E8
Open Tender
Civil Works
Item Rate
180 days
Shibpur, Port Blair
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (South) Diglipur
₹2.1 L
Yes
29 Jul 2020
28 May 2020
30 Jun 2020
28 May 2020
25 Jun 2020
11 Jun 2020
28 May 2020 - 4 Jun 2020
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in soft/loose soil all as specified and directed.
Rough excavation not exceeding 1.5 m deep and getting out in any type of soil all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil all as specified and directed.
Excavating over areas, exc 1.5 m and not exc 3.0m deep and getting out in hard/dense soil all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft /loose soil all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and depth exceeding 1.5 m but not exceeding 3.0m ; for foundations, laying of pipe and cables etc or for shafts, well cess pits, manholes,pier holes not exceeding 10 sqm on plan, including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in any type of soil complete all as specified.
Returning and filling in including spreading levelling watering and well ramming in layer n.exc 25 cm using soil obtained from excavation all as specified and directed.
Sand filling (River sand from mainland)under floors or in foundations including watering and consolidation all as specified and directed.
Removing of excavated material to a distance exc.50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
Material and labour Loose filling with broken stone or boulders of gauge 80 to 150 mm in soakage pits, soakage wells all as specified and directed.
Material and labour for Hardcore with broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
Material and labour Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and directed.
Material and labour plain cement concrete in foundations, filling and mass concrete in type C2 ,1:3:6 (using 40 mm graded stone aggregate) complete all as specified and directed.
Material and labour plain cement concrete in foundations, filling and mass concrete in type D2 ,1:4:8 (using 40mm graded stone aggregate)complete.
Material and labour plain cement concrete in foundations, filling and mass concrete in type B2 ,1:2:4 (using 40 mm graded stone aggregate)complete all as specified and directed.
Material and labour PCC 1:2:4, type B0(using 12.5 mm graded stone aggregate) as in kerb stone rounded or chamfered on edges including necessary form work etc. all as specified and directed.
Material and labour Plain cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in coping, kneelers water throughs bed plates, kerbs and like including weathering, slightly rounded or chamfered engles and throating, finished even & smooth without using extra cement including necessary form work etc.complete all as specified and directed.
Material and labour precast cement concrete block with 1:3:6 type C1 using 20mm graded stone aggregate for block masonry with solid blocks exc 10cm in width and setting in cement mortar 1:4 complete all as specified.
Material and labour precast cement concrete block with 1:3:6 type C1 using 20mm graded stone aggregate for block masonry with solid blocks exc 10cm in width and setting in cement mortar 1:6 complete all as specified.
Providing precast ce-ment concrete type B1 ,1:2:4 (using 20 mm graded aggregate)in lintels n.exc 1.5m clear span with plain fair faces, including cham-fers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match all as specified and directed.
Material and labour precast cement concrete block with 1:3:6 type C1 using 20mm graded stone aggregate for block masonry with solid blocks , 7.5cm in width, setting in CM 1:4 all as specified and directed.
Material and labour Reinforced cement concrete design mix M-30 (using 20 mm graded stone aggregate) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.
Material and labour Reinforced cement concrete design mix M-30 (using 20mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
Material and labour Reinforced cement concrete design mix M-30 (using 20mm graded stone aggregate), beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
Material and labour Reinforced cement concrete design mix M-30 (20 mm graded aggregate) for column, pillars, piers, posts and struts all as specified and directed.
Material and labour Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement , including forms, moulds, mitred/stopped ends etc complete all as specified
Material and labour Extra for forming fair finished drain or channel 45cm inner girth in cement concrete using extra cement , including forms, moulds, mitred/stopped ends etc complete all as specified
Supply only Integral water proofing compound complete all as specified and directed.
Material and labour Damp proof course 40 mm thick in cement concrete 1:2:4 type B-0,using 12.5mm graded stone aggregate including necessary form work with WPC as per manufacturer instruction by weight of cement. Note:- WPC shall be measured and paid separately under nrelevent item of this schedule.
Material and labour broken stone or boulder of size 40 to 80 mm size filling dry hand packed at back side of retainning wall for weep holes as specified and directed.
Use and waste of formwork using steel shutter flat to sides of concrete foundations, footings, bases of columns, and plinth beams and similar work vertical or to batter rough finished surfaces of concrete all as specified .
Use and waste of formwork using steel shutter flat to sides of concrete slab n.exc 200mm thick,chajjas,fins facia, para pets and similar work vertical or to batter fair finished surfaces of concrete all as specified.
Use and waste of formwork using steel shutter flat to sides of concrete of pillars, posts, struts, piers, and beams exceeding 1.5m span columns and stanchions square, rectangular or polygonal fair finished all as specified.
Use and waste of formwork using steel shutter flat to sides of concrete, treads, breaks in floors, window cills, concrete rail- ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon- tal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed.
Material and labour hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work conforming to Fe-290 Gde E-165
Material and labour MS work such as rungs, handles to manholes, etc as directed by Engineer-in-Charge.
Material and labour mild screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut of any length and not exceeding 15 mm dia complete all as specified and directed by Engr-in-Charge .
Material and labour Mild steel TMT Bars 10mm dia and over cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia., or securitn with clips
Material and labour Mild steel TMT Bars 6 to 8mm dia cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia., or securitn with clips
Material and labour Mild steel TMT Bars 5 dia and over up to and including 10mm dia as in stirrupscut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed ) not less than 0.9mm dia., or securitn with clips
Material and labour structural steel section Fe-410W (Gde E- 250) quality-A, as in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices, frames for wall panels etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, including cutting, notching, drilling, fitting, riveting and/ or welding or connecting with nus, bolts, providing and fitting cleats, fish plates, gusset plates etc. complete all as specified and directed.
Supply & Fixing rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe-410-W (Gde-E-250) quality A complete all as specified and directed by Engr-in-Charge. .
Supply & Fixing Hollow structural steel section, cold/hot formed, rectangular/square section , of specified 1st grade as in trusses of any shape and size, vertical post/column/structs/ top pipe of any shape and size and similar work, complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 including cutting, notching, drilling, fitting, riveting or welding or connecting witj nuts , bolts, providing and fitting cleats, fish plates, gusset plates etc complete all as specified.
Material and labour Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
Material and labour Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip and straight flashing, eaves board etc, cut to length and bend to shape and fixed with self tapping screws complete all as specified and directed by Engr-in-Charge .
Material and labour Providing PCC 1:3:6 types C1 (using 20mm graded stone aggregate) 75mm thick as in plinth protection, with necessary expansion joints as specified in SSR, finishing cement concrete surface even and fair without using extra cement.
Material and labour 75mm thick PCC 1:4:8 type D-2, (using 40mm graded aggregate) as in sub base to floor etc complete all as specified.
Material and labour 100mm thick PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in sub base complete all as specified.
Material and labour 40mm thick Cement Concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor including finishing the cement concrete surface to receive the fixing of tiles complete all as specified.
Material and labour 150mm thick cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in floor/hard standing finish including finishing cement concrete surface even and smooth and finally finishing the surface by belting/brooming without using extra cement complete all as specified.
Material and labour 40mm thick Cement Concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in floor including finishing cement concrete surface to receive the fixing of tiles complete all as specified.
Material and labour Vitrified Ceramic tiles 600x600x10 mm thick (square/ rectangular) polished, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
Material and labour Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
Material and labour chequered cement concrate coloured tiles of size 30cmx30cmx25mm thick, set, jointed and pointed in neat cement slurry and pointed with grey cement and pigment complete all as specified.
Material and labour rendering 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces finished even and smooth with out using extra cement complete all as specified.
Material and labour rendering 5 mm thick in CM I:4 over backing coat of 10 mm thick in C M 1:6, complete, the 5mm thick finishing coat shall be mixed with water proofing compound @3% by weight of cement and finished even and smooth without using extra cement all as specified and directed Note:-WPC shall be measured and paid separately under relevent item of this schedule.
Material and labour 15mm thick rendering on fair faces of brick work/ concrete surfaces , two coat plaster work consisting 10 mm thick under coat in cement mortar 1:6 and top layer 5mm thick in cement mortar 1:4 ,finished even and faircomplete all as specified and directed.
Material and labour 15mm thick screed bed in CM 1:4 as bedding layer in floors for receiving tiles complete all as specified and directed.
Material and labour applying two coats of cement base paint over a coat of primer on new plaster or untreated surfaces on walls including preparation of surfaces all as specified.
Material and labour applying two coats of synthetic enamel paint over a coat of primer including preparation of new or previously untreated concrete surfaces of any description over 10cm width or girth complete all as specified.
Material and labour applying two coats of synthatic enamel paint over coat of red oxide zinc chrome primer including preparation of new steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified.
Material and labour GI pipe light grade 40mm for cable protection laid in trench/wall/floor complete all as specified and directed. .
Material and labour GI pipe light grade 25mm for cable protection laid in trench/wall/floor complete all as specified and directed. .
Supply & Fixing 50mm dia low density polythelene pipe(LDPE) of pressure rating 6 Kg/SqCm fixed in weep holes complete all as specified.
Supply & Fixing 3- layer PP-R (Polypropylene random copolymer) pipes SDR 11, 20mm outer dia, UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed on floor/wall/ceiling/laid in trenches complete all as specified and as directed.
All as item ser No 66 above but pipe for outer dia 25mm
All as item ser No 66 above but pipe for outer dia 40mm
Supply & Fixing 20 mm bore PP-R valve(brass insent) ISI Marked, screwed both ends suitable for PR-R pipe. complete all as specified and directed.
All as item ser No 69.0 above but for size 25 mm bore
All as item ser No 69.0 above but for size 40 mm bore
Supply & Fixing in repair Rotational moulded polyethlene water storage tank, double layered 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I complete including float valve 25mm dia suitable for inlet all as specified and directed.
Supply & Fixing 15mm bore dia brass CP bib tap fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified and directed.
Supply & Fixing 15mm bore dia Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed.
Supply & Fixing 15 mm bore dia Stop valves fancy type chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified and directed.
Supply & Fixing grating doom 100mm dia of PTMT (Minimum weight 25 gms) all as specified and directed. Make : Cat Part No 181C of Prayag or equivalent.
Supply & Fixing Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) all as specified and directed. Make : Cat Part No 181C of Prayag or equivalent.
Supply & Fixing Shower arm 15 mm size, 225 mm long with bend of 45degree with flange of PTMT any colour.(Minimum weight 40gms) all as specified and directed. Make : Cat Part No 200 of Prayag or equivalent.
Supply & Fixing Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) all as specified and directed.
Supply & Fixing PVC connection 15mm dia and 300mm long with synthetic metal nut all as specified and directed. .
Material and labour 100 mm internal dia Cast iron soil (Sand Cast pipes), confirming to IS 1729-2002 waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed by Engr - in - charge.
Supply & Fixing CI bend 100 mm dia (any radius) diminishing pieces etc all as specified and directed.
Supply & Fixing Bends 100mm dia CI bends with oval access door (any radius), diminishing pieces or tapers (larger bore measured) all as specified and directed.
Supply & Fixing for CI Branch pipes 100mm dia (equal or unequal) with parellel branches all as specified and directed.
Supply & Fixing 100 mm dia CI 'P' or 'S' trap all as specified and directed. .
Supply & Fixing CI cowls suitable for 100 mm dia pipe complete all as specified
Supply & Fixing 100 dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified and directed.
Material and labour for PCC 1:3:6 type C2 as in bed to drain pipes incl packing under and haunching against the sides of pipes after they are laid and tested for CI pipe 100mm bore all as specified and directed.
Supply & Fixing salt glazed stoneware gully traps square type 'P' and size of gully trap 150 x 150 mm.
Supply & Fixing soap dish, PTMT any type fixed to plugs with chromium plated brass screws all as specified and directed. Make : Cat Part No 180 of Prayag or equivalent.
Supply & Fixing 12mm thick Figured glass , pin head type and glazing n exc 0.5 sq. m in each pane fixed with suitable aluminium frames all as specified and directed.
Supply & Fixing 50mm thick tongued and grooved sandwitch panels comprising of 0.35mm thick precoated plain galvanised steel sheet on both side (inner and outer) and middle core PUF (non CFC) of density not less than 40 kg/cum complete all as specified and directed for outer walls of double storey porta cabin.
Supply & Fixing aluminium door with powder coated aluminium sections (minimum 50 micron thick coating), of size 900 x 2100 mm single or double door partly panelled with panel insert of aluminium composite panel sheet 4.0 mm thick or partly glazed with plain glass 4.0mm thick and balance portion with gauzed using aluminium alloy wire cloth/mesh 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples with including necessary joining cleats, anodised aluminium snap beading, screws etc, complete with handles, Stainless steel butt hinges of suitable size, door stopper and necessary builders hardware complete all as specified and shown on drgs and as directed. Note:- The rate inclusive of Aluminum panel, Glass, wire mesh as applicable.
Supply & Fixing aluminium windows openable type with powder coated aluminium sections (minimum 50 micron thick coating) of size 1000 x 1200 width with four shutters, out of two fixed with 4mm thick float glass and two with anodised aluminium alloy wire cloth/mesh 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples with including necessary joining cleats, anodised aluminium snap beading, screws etc, stainless steel butt hinges of suitable size, locking handles complete fixed type all as specified and shown on drgs and as directed. Note:- The rate inclusive of Aluminum panel, Glass, wire mesh as applicable.
Supply & Fixing aluminium ventilators fixed type with powder coated Aluminium section (minimum 50 micron thick coating) of size 600 x 935mm with aluminium alloy wire cloth/mesh 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples with including necessary joining cleat complete all as directed. Note:- The rate inclusive of Aluminum panel, Glass, wire mesh as applicable.
Supply and fix Aluminium ventilators with powder coated aluminium sections (minimum 50 micron thick coating) of size 600 mm x 935 mm width for toilet block porta cabin with openable shutters and fixed with 4 mm thIck pin headed glass including stainless steel butt hinges of suitable size, locking handles complete all as specified and as directed.
Supply and fix 250 mm wide, 6 mm thick polymeric panels cut to suitable length for false ceiling with tongue and groove joints fixed to the grid work with self tapping screws including provision of necessary cut outs for light fittings and with hook for ceiling fans including GI slotted intermediate grid channels (35 mm x 60 mm) of 0.35 mm thick, at every 600 mm fixed to mild steel support with self tapping screws, GI grid periphery channel (25 mm x 35 mm), 0.35 mm thick, provided along the wall/partition with self tapping screws for porta cabins, and suspended with Gl cleat and steel expansion fasteners with and nut bolts for adjusting the level complete all as specified and as directed.
Supply & Fixing sun shades with 250 x 6 mm thick polymeric panels with tongue and groove joints fixed to the 25 x 25 x 1.6 mm thick MS hollow secton support frame work with no. 8 x 13 self tapping screws. The size of sunshade shall be 1200 x 500 mm complete all as specified and shown on drgs and as directed.
Supply & Fixing 1.80 mm thick vinyle flooring for first floor, of approved shade and pattern pasted with adhesive as per manufactures instructions over and including 19mm thick fibre cement board fixed to steel frame work complete all as specified and as directed. The floor load capacity shall not be less than 200kg/sqm. Note: Steel frame work shall be measured and paid seperately
Material and labour lipped channels made out of mild steel of grade Fe-410W (Gde E- 250) quality-A, as in floor grid, purlins, legs, stairs, floor runners, stringers, railings, stair support frames, etc., cold/hot formed of any shape and size and similar work including cutting, notching, drilling, fitting, riveting and/ or welding or connecting with nuts, bolts , providing and fitting cleats, gusset plates etc. complete all as specified and directed.
Supply & Fixing 3mm thick UPVC sleeves to pressed steel channels of 75 mm x 40 mm to make the mild steel unexposed to weather complete all as specified and directed.
Material and labour 110mm bore PVC (SWR) pipes for rain water pipe, plain end ISI marked IS-13592, type 'A' , pressure rating not less than 6kg/Sqcm in any length fixed in walls, at every 6m with PVC elbow, MTA, MS clamps made out of 25x6mm flat, screw etc complete all as specified.
Supply & Fixing 25mm thick plastrocrete panels for outer walls and partitions of single storey porta cabins, polymeric section filed with low density cellular concrete, panels of size 1000 x 300 mm, jointed together by tongue and grooved method to ensure 100% leak proof, including necessary fittings complete all as specified and directed .
Supply & Fixing 25 mm thick PVC door of size 760 x 1950 mm with PVC outer frame for toilets with standard accessories such as stainless steel hinges, latch lock, sleek O-Matic door closer etc complete all as specified and directed.
Supply & Fixing looking mirror consisitng 5.5mm thick glass mounted on stainless stud,4 Nos including necessary drilling complete all as specified.
Supply & Fixing for CI vent pipe 100mm dia with or without ears with cement joints fixed to walls.
Supply & Fixing Vitreous China Squatting pan, `Orrisa` pattern size 580 x 440 mm (ISI marked) white with integral foot rest with suitable CP Trap including necessary concrete work and finished to match the surface all as specified.
Supply & Fixing vitreous china urinal bowl type flat back size (465 x 355 x 265 mm) mm white grating and union and discharge pipe, waste pipe etc, including providing and fixing plugs, bedding urinal against wall in CM (1:2) including suitable arrangements for fixing the urinal in wall panel all as specified and directed by Engineer in Charge.
Supply & Fixing 10 litre PVC valveless, syphonic action type flushing cystern low level with inlet valve, float and handle and PVC outlet suitable for IWC/EWC all as specified..
Supply & Fixing Vitreous China wash basin, flat back, size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets, waste pipe etc and fixing the wash hand basin in wall panel with necessary fixing arrangements complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Soling 150mm thick (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified .
Material and labour 15cm thick in two layer of 7.5cm (compacted thickness) WBM, with coarse aggregates of grading 2(63 to 40mm size) or of grading 3 (50 to 20mm size), spread, rolled and consolidated to gradient and camber required complete all as specified .
Forming 12mm thick & 100mm deep expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified .
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade ‘B’ complete all as specified .
Supply, laying and testing XLPE Insulated cable of size 6 sq mm 2 core, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor .
All as per item ser no 115.0 above but of size 10 sq mm 4 core
All as per item ser no 115.0 above but of size 16 sq mm 4 core
Supply & Fixing Switch , Single pole, one way, 6 amps, 230 Volts
Supply & Fixing Switch , Single pole, two way, 6 amps, 230 Volts
Supply & Fixing PVC box type switch Socket outlet 3&2 pin 5A, 240 V,flush type universal controlled by one switch with ISI mark complete all as specified.
Supply & Fixing PVC box type switch Socket outlet 3& 2 pin 5/16 A, 240 V,flush type universal controlled by one switch with ISI mark complete all as specified.
Supply & Fixing epoxy powder coated distribution box, double door for MCB of capacity SPN, 12 ways, 240 volts, fixed to platocrete walls complete with IP 43 and metal door all as specified and directed.
All as per item ser no 122.0 above but for capacity SPN, 8 ways, 240 volts.
All as per item ser no 122.0 above but for capacity MCB, TPN, 4 ways, 415 volts.
Material and labour ceiling rose , 3 terminal ceiling rose 6A, all as specified.
Supply & Fixing electronic fan regulator 5 step complete all as specified .
Material and Labour point wiring fixed on wall of plastocrete panel/ laying on top surface of false ceiling , controlled by one, one way switch, using 1.5 sqmm nominal cross sectional area multistranded copper conductor,PVC insulated unsheathed (FRLS), single core cables in and including 20mm dia , medium grade PVC conduit , with 1.5 sqmm nominal cross sectional area multistranded copper conductor , PVC insulated unsheathed FRLS earth wire etc, excluding terminal boxes all as specified for following:-
One light point controlled by one switch
One ceiling /exhaust fan point controlled by one switch
One three pin socket 5Amp plug point controlled by one switch on independent board
One light point controlled by one two way switch
Material and Labour point wiring on independent box, fixed on wall of plastocrete panel/ laying on top surface of false ceiling for one 16 Amps socket outlet point on independent board controlled by one, one way switch, using 2.5 sqmm nominal cross sectional area multistranded copper conductor,PVC insulated unsheathed (FRLS)1100 Volts grade , single core cables in and including 20mm dia and higher medium grade PVC conduit, with 2.5 sqmm nominal cross sectioanl area multistranded copper conductor, PVC insulated unsheathed FRLS earth wire excluding terminal boxes complete all as specified.
Material and Labour for submain wiring fixed on wall of plastocrete panel/ laying on top surface of false ceiling comprising 2 runs of 4sq mm and one run of 4 sqmm (as earth wire) , single core , multistranded copper conductor cable, PVC insulated unsheathed (FRLS) 1100 Volts grade drawing in and including PVC conduit and conduit fittings , medium grade not less 20mm dia complete. Note :- (i) 2 runs of 4 sqmm, one run of 4 sqmm cable and one run of PVC conduit will be measured as one unit/ RM. (ii) Extra length of cables/ wire required for connection to MCB shall not be measured and the rate quoted by contractor for per unit shall be deemed to be included in the quoted rate
Supply & Fixing Miniature circuit breakers , 240 Volts , 10 KA rating and to be housed in sheet metal enclosures ( distribution boxes) complete all as specified and directed of following sizes :- Note :- Proper and suitable size cable lugs to be fixed with Miniature circuit breakers are included in unit rate of each Miniature circuit breakers of any rating.
SP, 6 to 20 Amps
SPN, 20 Amps
SPN, 10 Amps
TPN, 16 Amps
Supply & Fixing ceiling fan 1200mm sweep,5 star rates , white/ coloured complete with down rod, canopy and making connections with and including 3 core flexible cable, PVC insulated with Stranded copper conductor of suitable size complete all as specified .
Supplying, installing, testing, commissioning exhaust fan heavy duty, 300 mm sweep, 230 Volts, AC , 50 Hz, 1370 RPM air delivery 1600Cum/hr with accessories, and connecting the fan to ceiling rose with 3 core copper cable of size 23/.0076 complete all as specified. Make : Aeroclean of Usha or equivalant
Material and labour LED street light fittings 1x 15 watt complete fixed on wall of plastocrete panel including 1.2 m light grade GI pipe, 25mm dia bend to shape at an angle of 120 degree, suitable fixing clamps etc, and providing connections with PVC insulated sheathed copper conductor cable from ceiling rose to connector complete all as specified and directed.
Supply & Fixing LED Lamp 9W complete retrofit type complete all as specified .
Material and labour LED tube light fittings box type 1X22 W complete fixed on wall/ceiling and providing connections with PVC insulated and sheathed conductor cable from ceiling rose to connector complete all as specified and directed.
Material and labour for Cutting of 50 mm existing GI pipeline and taking a new connection with necessary fittings and 'T' joints of size 50 x 50 x 40 mm complete all as specified . .
Material and labour for Construction of masonary valve chamber internal size: 600 x600x600mm, 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks set in cement mortar 1:4, 15mm thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement , 3.15mm thick MS sheet cover including 50mmX50mmX6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50m complete all as specified and shown on drawing .
Material and labour DWC pipe for sewage line 150 mm dia with joints, laid in trenches or in floors complete all as specified and directed by Engr - in - charge.
Supplying and laying DWC ( Double wall corrugated) ISI-14930 Marked, HDPE pipe 50 mm outer dia and 38 mm inner dia with smooth internal and external surfaces for non pressure under ground cable including all fittings like couplers,'O' ring, bends etc. for under ground cables complete all as specified.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI wire 4mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I .
BHARAT MULTITECH INDUSTRIES PVT LTD
kakolil trade agencies
CITY CONSTRUCTION COMPANYU
M/s V M K Construction
NAWAZ CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
80176Tenderdocuments.pdf
Tender Documents • 0.97 MB
BOQ_388587.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .