Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹3.4 L
EMD Value
₹6,730
Closing Date
12 Oct 2026, 3:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
Providing earthing
2026_PWD_299464_1
71/EE (E)/PWD EMD South West/2026-27
Open Tender
Electrical Works
Percentage
30 days
works
Please refer Tender documents.
11 documents required · 11 mandatory
₹0
₹6,730
5 Oct 2026
5 Oct 2026
12 Oct 2026
5 Oct 2026
12 Oct 2026
5 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required | 10 | Set | 7,658 | ₹76,580 |
| 2 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. | 400 | Meter | 50 | ₹20,000 |
| 3 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. | 400 | Meter | 287 | ₹1,14,800 |
| 4 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | 50 | Meter | 755 | ₹37,750 |
| 5 | Locating and reviving the buried earthing pit, including cleaning rusted terminals, replacing nuts and bolts, adding charcoal and salt to improve conductivity, watering through the pipe, and providing a new CI cover if required etc complete as required. | 10 | Job | 1,386 | ₹13,860 |
| 6 | Cutting of hard rock/road/PCC/paver block for laying of earthing strip/ UG cable with the help of hilty /hammer etc i/c making good by laying in position cement concrete 1:2:4 (1 cement : 2 coars sand : 4 graded stone) of size 0.2 B x 0.2 D mtr. etc as required after laying of DWC pipe etc as reqd. | 50 | Cu.Mtr. | 213 | ₹10,650 |
| 7 | Supply of 6.0 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable complete etc as reqd. | 30 | Mtr. | 81 | ₹2,430 |
| 8 | Supply of 1.5 sq. mm ISI marked, FRLS/HFFR PVC insulated, single core copper conductor cable complete etc as reqd. | 20 | Mtr. | 23 | ₹460 |
| 9Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). | |||||
| 9.01 | 250 watt | 11 | Each | 5,450 | ₹59,950 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.59 MB
BOQ_399665.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .