| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.9 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹35.2 L+₹3.2 L (9.89%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest bidder | |
| 3 | L3₹37.9 L+₹5.9 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest bidder | |
| 4 | L4₹38.5 L+₹6.5 L (20.5%)Rejected-Finance | L4 | Rejected-Finance Not being Lowest bidder | |
| 5 | L5₹39.5 L+₹7.5 L (23.4%)Rejected-Finance | L5 | Rejected-Finance Not being Lowest bidder |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
8 Feb 2020, 6:00 pmClosed
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR/MAINT OF WINDOW/SPLIT TYPE AC, REFRIGERATION, WATER COOLER, VARIOUS AC PLANT AND CERTAIN MISC WORK UNDER GE E/M LUCKNOW
2020_MES_313414_1
GE/EM/LKO/EXT(WS)/79 OF 2019-2020
Open Tender
Miscellaneous Works
Item Rate
180 days
Lucknow
Class D or above category c (i)
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹94,000
Yes
30 May 2020
9 Jan 2020
10 Feb 2020
9 Jan 2020
8 Feb 2020
31 Jan 2020
Amount
Labour only for collecting the complaints of various unit/location etc and all other AOR of AGE E/M (ws) pertains to split / window type ACs / Water Coolers / refrigerators of any capacity and make from concern JE of AGE E/M (ws), attending these at site to assess the actual fault after opening of ACs and fixing only spares required to make it fully functional in all respect and handing over the report duly signed by the user by name to concern JE all as directed. (Spare parts shall be measured and paid separately under appropriate items)
M&L for taking down of window type AC of any capacity or model and transporting and refixing at New Location with opening/cutting of wall for fixing of window type AC and painting the same including covering of old/new opening with Ply( with minimum 3 mm thickness) all as specified and directed by Engr-In -Charge.
Taking out defective blower motor from window type AC of cap 1.5/2.0 TR or outdoor unit of Split type AC of capacity 1.5 TR / 2 TR and transporting defective motor of any make & capacity from site to contractor workshop dismantling the burnt winding & rewinding of 1 / 5 to 1 / 8 HP blower motor with the required size of super enameled copper winding wire of suitable gauge including insulation, varnishing, greasing, testing complete and transporting to back to site and refixing complete all as specified and directed.
M&L for renewal of starting capacitor of 100-120 Mfd capacity mfd in plastic container all as directed by EIC.
M&L for renewal of starting capacitor of 80-100 Mfd capacity mfd in plastic container all as directed by EIC.
M&L for rewal running capacitor of capacity 36 Mfd in plastic container complete all as directed by EIC.
Supply and repairs of running capacitor of capacity 50+5Mfd in plastic container complete all as directed by EIC.
Supply and repairs of starting relay for 1.5 TR / 2 TR compressor all as directed by EIC.
Supply and repairs of overload protector for 1.5 TR / 2 TR compressor all as directed by EIC.
Supply and repairs of Air Censor for temperature control for 1.5 TR / 2 TR compressor all as directed by EIC.
S&F in repairs Thermostate switch for 1.5 TR / 2 TR Window type AC all as directed by EIC( Make :- Carrier/ LG/Voltas/National/Casino type)
S&F in repairs Swing motor for 1.5 TR / 2 TR indoor unit of split type air conditioner all as directed by EIC.
S&F in repairs Swing motor for 1.5 TR / 2 TR window AC all as directed by EIC( Make :-LG/Carrier/Voltas/LG).
S&F reverse cycle solenoid valve in split type AC 1.5 / 2 TR capacity with necessary extension to suction/ discharge copper tubing & toggle switch complete all as directed by EIC
M&L for Converting the existing AC (window / split) type from cooling system to heating system of the existing AC by using necessary items/ equipments/toggle switch etc. from window/split type of any capacity ( Excluding reverse cycle valve, which shall be measured separately if required).
S&F ( in repairs) suction copper pipe line heavy duty ½” dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F( in reapirs) discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S & F( in repairs) PVC insulated three core stranded copper cable of size 80/0.20 ( 2.5 sqmm) all as specified and directed .
S & F ( in repairs) copper Gas filter for AC 1.5 TR / 2 TR capacity all as specified and directed
S & F( in repairs) PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall all as specified and directed.
Dismantling of existing window type AC. from its location and refixing after doing the following repairs wherever required and as directed by EIC. (a) Servicing by oiling & cleaning with liquid soap , cleaning of fins by means of air blower and water with pressure jet and changing of air filter complete with cleaning of Cooling & Condensing coil all as directed by EIC. (b) M&L for painting of outer cage and front grill window type A/C with two coats of synthetic enameled paint of approved shade and tint including preparation of steel surface by emery paper including writing SM No. / MES No. etc with front of grill complete all as directed by EIC
Renewal of plywood 6 mm thick,BWR, grade 1, one side decorative teak veneers and other side commercial veneered finished complete as directed by EIC
Renewal of 2nd class HW (SAL) fillets, cross sectional area excd 3 and not excd 6 sqcm on all four sides of window type AC splayed or chamfered edge including polishing etc complete all as specified and directed.
Dismantling of defective indoor unit of 1.5 TR capacity split type AC and supply & fixing indoor unit of the same capacity with blower motor, front grill and connecting the copper tubing by brazing detecting leak and rectifying the same and recharging with Non CFC refrigerant gas as required the unit in wall/ceiling mounted all as specified and directed.
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 1.5 TR capacity and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as directed . ( Make :- Totaline/ Bluestar/ Acent/Skoda/ Opel/LG)
Dismantling of defective condensing unit ( outdoor unit) of spilt type AC of 2 TR capacity and supply & fixing new condensing unit ( except compressor) complete with condensing coil, coil frame, wiring kit and running capacitor, relay, condensing motor with blade complete all as directed . ( Make :- Totaline/ Bluestar/ Acent/Skoda/ Opel/LG)
S & F ( in repairs) MCB SP -6 to 32 Amps rating to be housed in DBs catered here in after complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating)
S&F in repair plug and socket DBs with single pole MCB rated 32 Amps capacity with socket plug top 2 pin and earth plug complete all as specified including making niche in wall and mounted flush complete all as specified and directed.
S&F in repairs Mettalic Plugs ( top) of AC box 20A, specified make , 2P+E and connecting all as specified and directed
Dismantling of defective cooling coil of 1.5 TR window type AC of any make and S&F cooling coil for AC, detecting the leakage with N2 Gas, reconnecting in to the system complete all as specified and directed
Dismantling of burnt blower motor of 1.5 TR/2.0 TR split AC double shaft ( indoor unit) and supply & fixing new blower motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of burnt outdoor fan motor of 1.5 TR/2.0TR split AC single shaft (outdoor unit) and supply & fixing new outdoor fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of burnt fan motor of 1.5 TR/2.0TR window AC double shaft and supply & fixing new fan motor Suitable for Carrier/Voltas/Blue star/LG/Samsung Make ACs as per sample complete all as specified and directed.
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F new compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :_ (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F compressor rotary type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 1.5 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Dismantling of unserviceable compressors of 2 TR capacities of window/split type ACs including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC. Note :- (i)The electrical accessories required will be measured and paid for separately. (ii) The compressor of make – Emerson Model CR-22 / CR-30 or equivalent of Carrier/ Kirloskar/ Blue star
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 3 TR capacity comprising of Blower, blower motor ,water lifting motor, oiling & greasing of moving parts complete all as specified and directed.
Servicing of IDU (Indoor unit) of ceiling mounted casset type split Air conditioner of 4 TR capacity comprising of Blower, blower motor ,water lifting motor, oiling & greasing of moving parts complete all as specified and directed.
Servicing of condensing unit comprising of condensing coil, condensing fan and tubing by cleaning condensing coil tighting nuts, bolts, screw and other petty repairs ceiling suspended split AC of capacity 3 TR all as directed by EIC.
Servicing of condensing unit comprising of condensing coil, condensing fan and tubing by cleaning condensing coil tighting nuts, bolts, screw and other petty repairs ceiling suspended split AC of capacity 4 TR all as directed by EIC.
Renewal of remote hand set of window type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar)
Renewal of remote hand set of Split type air conditioner of cap 1.5/2.0 TR of existing make with and including pencil cells complete all as specified and directed (Make:- LG / Samsung / Bluestar)
S&F in repairs brass suction valve size 3/8" complete all as specified and directed
S&F in repairs Discharge valve size 1/2" complete all as specified and directed .
S&F ( in repairs) charging valve 1/4" dia for carrier make split AC all as per directed by EIC
S&F in repairs flare nuts size 3/8" complete all as specified and directed
S&F in repairs flare nuts size 1/4"complete all as specified and directed
S&F in repairs flare nuts size 1/2" complete all as specified and directed
S&F in repairs ML-1 contactor 240 volt, 25 Amp for split type AC complete all as specified and directed
S&F in repairs copper capillary of size 0.55 mm complete all as specified and directed.
S&F ( in repairs) Aluminium fan blade with gun metal bush of blower , Screw complete as per complete all as directed by EIC
S&F Aluminium runner for window A.C. as per sample complete all as specified and directed
Supply and fixing ( in repairs) PVC knob of window type AC complete all as specified and directed (Make LG / Carrier/Voltas)
Supply and fixing in repairs front grill quality for window AC of 1.5 TR/ 2 TR of Make National/ Casmo/LG/Carrier / Blue Star/Samsung all as specified and directed
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable corded electronic remote control, supply and fixing new control wiring and corded electronic remote control to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:- ITC / Carrier / Cool Air)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:-Carrier / LG- HI- SERIES)
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR ( heating and cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:-Carrier / LG- HI- SERIES)
Dismantling of defective worn out wiring of window AC/Split ac of capacity 1.5 TR / 2 /3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixing PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 3 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control and sensor supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:-Carrier / LG- HI- SERIES).
Dismantling of defective worn out wiring of CASSETE Type AC of capacity 4 TR ( Heating/ cooling type) including unserviceable cordless electronic remote control, supply and fixingNEW PCB (Printed circuit Board) & Visual Eye demo plate and cordless remote hand set to suit / match the existing system all as specified and directed by EIC (Make of AC and remote:-Carrier / LG- HI- SERIES).
S&F of New Water pump for CASSETE Type AC of capacity 3 TR/4TR including Floate valve and connected items.
M&L for dismantling of defective PCB of 1.5/2.0 TR capacity SplitAC of any make &(cooling only/hot& cold type) from indoor unit and transporting to contractors workshop for repair of the same,transporting back to site & refixing to indoor unit to ensure proper functioning of the AC all as specified and directed
All as per item No 63 above but for 1.5/2.0 TR WINDOW AC OF any make.
All as per item No 63 above but for 3.0/4.0 TR cassette type AC OF any make.
Dismantling carefully front cover of indoor unit split type AC of any make & model of capacity 1.5 / 2 TR and disconnecting the water drain pipe for cleaning sludge etc refixing the water drain pipe at its original position of indoor unit including provision of necessary accessories for fixing of drain pipe and testing complete for proper functioning of indoor unit and refixing of front cover all as specified and directed.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete of 1.5 TR capacity all as specified and directed by EIC.
M & L for servicing of Indoor unit and outdoor unit by means of electric blower & water under pressure ,cleaning & washing of cooling/condencing coil by soap solution or recommended chemical ,oiling & greasing of moving parts such as blower motor etc complete of 2 TR capacity all as specified and directed by EIC.
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22 into the system for 1.5 TR capacity split type AC all as specified and directed. (The refrigerant gas R-22 will be provided by Contractor)
M & L for Nitrogen pressure testing,flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22 into the system for 2 TR capacity split type AC all as specified and directed. (The refrigerant gas R-22 will be provided by Contractor)
M & L for Nitrogen pressure testing Flushing out the system by Nitrogen ,vacumrnation and charging of refrigerant gas R-22 into the system for 1.5 TR/ 2 TR capacity Window type AC all as specified and directed. (The refrigerant gas R-22 will be provided by Contractor)
Supply & Charging (Top up) the AC unit of 1.5 TR / 2 TR split type AC unit with refrigerant gas R-22 in required Qty complete all as specified and directed
S&F ( in repairs) 1100 volts grade heavy duty cable PVC insulated 10 sqmm multistranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm dia. Galvanised mild steel suspension wire, one twin core circular cable complete all as specified.
Servicing and overhauling of walk in cooler of any make and of size 19950 litre make Blue star Model - PC 1950 with 10 Nos strainer steel product and with two condensing unit installed at any location in cantonment including cleaning and painting internally and externally with two coats of synthetic enamel paint ; reparing/ renewal/replacement of defective parts and component all as specified and directed. Parts renewed shall be measured and paid separately under appropriate items
Taking out unservieable blower motor of capacity 1/8 HP from walk in cooler and rewinding it with super enamelled copper wire of suitable size, testing and reassebling in position all as directed.
Supply, installing, commissioing and testing , inverter type , split Air Conditioner of capacity 1.5 TR (Hot & Cold) with rotary compressor , Nano Titanium filter, auto clean function, indoor sound level 32 db, front panel display, wireless LCD remote, precoated aluminium fins, 477 cfm air circulation , auto fan speed, 5 star rated, electric driven , suitable for working on 230 volts, single phase, 50 Hz supply complete including cutting of wall, providing stand for out door unit and making good disturbed surface of wall etc and remote operation complete, including dismantling of window/split AC any make all as specified and directed.
Supply & install voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +/- 2.5% and of capacity 4KVA.
Taking out compressor from water cooler of any make by cutting of suction and discharge lines for carrying out necessary repairs to the water cooler base such as renewal of MS angle iron , base plate, nuts , washers, bolts,compressor rubber grooves and refixing it including N2 flashing and charging of refrigerent with non CFC refrigerant gas matching with R-22 in required quantities and testing of 120/150 litres capacities of water coolers complete all as specified and directed.
All as per item No 79 above but for 40 / 80 Litres capacities of water coolers
Dismantling of unserviceable compressor of any make/brand from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-22, of 1 TR Capacity ( Make Emmerson Model HR-13) or equivalent of other specified make & Model complete all as directed by Engineer-in-Charge.
All as per item No 81 above but 1/3 TR capacity Compressor Model No. CAJ 34 G-DE1( KCJ-444HAG-B220 of Emerson)
Renewal of copper tubing 3/8"dia complete for fixing in water coolers complete all as specified and directed .
Renewal of copper tubing 1/2" dia in water coolers 150 litres capacity and refrigerators 165/286/300 Ltr complete all as specified and directed
Renewal of copper tubing 1/4" dia complete in water coolers 150 litres capacity and refrigerators 165/286/300 Ltr complete all as specified and directed
Renewal of CP pipe connector including flange, screw, CP nozzle of nipple, female nozzle and extention complete all as specified and directed
Taking out defective blower motor with blade and supply & fixing new blower motor with blade AC 240 volts, 50 HZ single phase, of 1/10 hp capaciites complete all as specified and directed.
All as per item No 87 above but for 1/16 HP capacity complete all as specified by EIC.
All as per item No 87 above but for 1/8 HP capacity complete all as specified by EIC.
All as per item No 87 above but for 25 W capacity complete all as specified by EIC.
Renewal of unserviceable aluminium fan blade of blower motor of 1/16 HP complete all as specified.
Renewal of unserviceable PVC fan blade of blower motor of 25 watt complete all as specified.
Renewal of unserviceable PVC fan blade of blower motor of 1/8 HP complete all as specified.
Renewal of unserviceable PVC fan blade of blower motor of 1/10 HP complete all as specified.
Renewal of condensing coil for 150 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge.
Renewal of condensing coil for 60/80 litres Capacity water cooler of any make all as specified and directed by Engineer-in-Charge.
Renewal of front panel of 60 / 80 litres capacity of water cooler made out of 22 gauge MS sheet of shape and size and providing two coats of spray painting with synthetic enamel paint over a coat of pink primer on all the surfaces of panel including discconeccting required parts and reconecting complete all as specified and directed.
All as per item No 97 above but for 150 Ltrs capacity water coolers.
M&L for disconnecting of water cooler of 150 litres capacities from its position, taking out water from its water tank, cleaning of water tank by washing with washing powder and with fresh water externally and internally and spray painting with synthetic enamel paint of approved tint/colour to all painted surface of water cooler of following capacities after preparation of old painted surfaces without disturbing the components & wiring etc. complete and reconnceting all as specified and directed by Engineer-in-Charge.
All as per item No 99 above but for 40 / 80 Litres capacities of water coolers
All as per item No 99 above but for 60 / 120 Litres capacities of water coolers
Checking of leakage in refrigerant system of water cooler of 150 litres capacity by putting nitrogen under pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuumising the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
All as per item No 102 above but for 40 / 80 and 60/120 Litres capacities of water coolers
Supply & fixing (in repairs) starting relay for 1 TR water cooler complete all as specified and directed .
Supply & fixing (in repairs) starting relay for 1/3 TR water cooler complete all as specified and directed .
Supply & fixing (in repairs) starting capacitor (conforming to IS:2993 - 1975) AC 230 volts in plastic container 80-100 mfd complete all as specified and directed .
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 15 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 25 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 36 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) overload protector for 1.00 TR compressor complete all as specified and directed .
Supply & fixing (in repairs) overload protector for 1/3TR compressor complete all as specified and directed .
S & F Thermostat long tail for water cooler complete all as specified and directed by Engineer-in-Charge .
S & F Thermostat short tail for water cooler complete all as specified and directed by Engineer-in-Charge.
Renewal of capacitor for blower motor of water cooler of 2.5 Mfd capacity all as specified and directed
Renewal of capacitor for blower motor of water cooler of 4.00 Mfd capacity all as specified and directed
Transporting defective blower motor of 1/ 16 HP capacities from AGE E/M yard to contractor's workshop, dismantling the burnt winding & rewinding of blower motor with the existing size super enameled copper winding wire including insulation, varnishing, greasing, testing and transporting back to AGE E/M yard all as directed by EIC.
All as per item No 116 above but for capacity of 25 Watt
All as per item No 116 above but for capacity of1/8 HP
S&F ( in repairs) gas filter, flare type, 3/4"x 1/2" flare, all as specified and directed by EIC.
S&F in repairs copper capillary of size 0.55 mm complete all as specified and directed
S&F ( in repairs) float valve , 15 mm bore of brass with nipple and polyethylene float valve complete all as specified.
Renewal of PVC connection 15 mm dia with brass ferule both and length 600 mm all as specified.
Renewal of Plug top 16 Amps, 250Volts, of anchor or equivalent of other specified make.
Renewal of Plug top 5 Amps, 250Volts, of anchor or equivalent of other specified make
Renewal of unserviceable PVC insulated , copper conductor cable, 3 core of size 48/20 complete all as specified.
Collecting unserviceable sealed/ cut compressor unit from AGE E/M yard / by taking down from the regrigerator and Supplying and fixing new sealed unit compressor suitable for 165 litres refrigerator ( 1/8 TR) capacities , charging with gas and making connections and testing complete all as specified and directed.
All as per item No 126 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
S&F cooling coil of 165 litres capacities refrigerator after disconnecting the cooling coil from refrigerator, Nitrogen gas pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as directed by Engineer-in-Charge.
All as per item No 128 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
S&F( in repairs) condensing coil of 165 litres capacities refrigerator by disconnecting condensing coil from refrigerator, N2 pressure testing and flushing out the system and charging of Non CFC gas as per required quantity and testing complete all as directed.
All as per item No 130 above but for capacity of 286/300/310 ltrs (1/6 TR) refrigrators
Dismantling of wornout base of water cooler fan blower motor of water cooler and S&F new base made out of 450mmx450mm sheet of 16 gauge including welding, rivetting and reinstalling the motor after repairs complete all as specified and directed.
Checking of leakage in refrigerant system of refrigerator of 165 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
Checking of leakage in refrigerant system of refrigerator of 286 /300/310 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity all as directed by Engineer-in-Charge.
S&F in repairs starting relay, open type for refrigerator of capacity 165/300/310 litres all as directed by Engineer-in-Charge.
S & F in repairs over load protector for 1/6 HP refrigerator of capacity 165/300/310 litres all as directed by Engineer-in-Charge.
S & F in repairs thermostat defrost type for refrigerator all as directed by Engineer-in-Charge.
S & F in repairs thermostat non defrost type for refrigerator all as directed by Engineer-in-Charge.
Dismantling of existing repairable deep freezers of any make and capacity from its position after disconnecting electric connections, transporting from site to Contractor's workshop for carrying out repairs and renewal/ replacements of Parts, reassembling and transporting back to the site including installation of the same on same location and making electric connection etc. complete all as specified and directed. (Note :- Parts renewed shall be measured and paid separately under appropriate item(s) listed herebelow.
Renewal of starting relay for 200 Ltr. Capacity deep freezer complete all as specified and directed.
Renewal of starting relay for 300 Ltr. Capacity deep freezer complete all as specified and directed.
Renewal of over load protector suitable for 200/300 Ltr deep freezer complete all as specified and directed.
Renewal of running capacitor for 200/300 Ltr capacity deep freezer complete all as specified and directed.
Renewal of thermostate suitable for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
Renewal of starting capacitor for 200/300 Ltr. Capacity deep freezer complete all as specified and directed.
Taking down defective compressor of following capacity of deep freezer of any Make and depositing same in AGE E/M EXT(WS) yard and Supplying and fixing sealed unit compressor as specified here under including brazing and with necessary nuts and bolts, copper filter, capalary and supply & charging of refgn Gas Non CFC in required Qty and testing 200 Litres capacity deep freezer compressor Model No. KCN 372 of Kirloskar complete all as specified and directed.
All as per item No 146 above but 300 Litres capacity deep freezer compressor Model No. KCN 411 of Kirloskar complete all as specified and directed.
Supply and install and testing of Deep freezer of capacity 300/320 Ltrs double door suitable for working on 230 Volt SP 50 Hz complete all as specified and directed.
Checking of leakage in refrigerant system of deep freezer of 200 / 300 litres capacity by putting nitrogen pressure, identifying the leak, rectifying the leak/defects by brazing and testing, vacuuming the system including charging refrigerant gas Non CFC in required quantity complete all as specified and directed.
Renewal of Fan Motor of deep freezer, 230Volts rating, AC, Single Phase, 50 Hz including disconnection and reconnecting and testing complete all as specified and directed.
M&L for taking down of Split type AC of any capacity or model and transporting and refixing at New Location including cleaning of filter with water and some minor repairs to make it fully functional again at new location with all as specified and directed by Engr-In -Charge.
Shree Tirupati Associates
M/s Hanspal Enterprises
Enviro India
M/s ARPIT ENTERPRISES
Ajanta Motor Store
JASPREET SINGH COOLING CORP.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .