Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹25.6 L+₹76,124.50 (3.06%)Rejected-Finance NO 577 5TH MAIN D GROUP LAYOUT 60 FEET ROAD SRI GANDHAKAVAL BANGALORE 560 091 | BANGALORE | BANGALORE | KARNATAKA | 560091 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹26.0 L+₹1.1 L (4.44%)Rejected-Finance NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹28.2 L+₹3.3 L (13.4%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
12 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY BANGALORE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPL REPAIRS TO ROAD AT VNC AND VSF QTRS AREA UNDER GE (CENTRAL) BANGALORE
2020_MES_393435_1
86024/E8
Open Tender
Civil Works - Roads
Item Rate
60 days
BANGALORE
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (Central) Bangalore
₹60,000
Yes
HQ CWE ARMY BANGALORE
8 Jan 2021
7 Nov 2020
15 Dec 2020
7 Nov 2020
12 Dec 2020
28 Nov 2020
7 Nov 2020 - 12 Nov 2020
12 Nov 2020
60 days
Amount
Repairs to pot holes any depth not exc 1 sqm each in area including sweeping free from dust and mud or water scoring sunken surfaces in roads, path, etc cutting around edges to at least 25mm depth, making good by filling in screened and graded road metal, watering and well ramming (including supply of road metal) completed all as directed.
Scarifying or picking graveled, macadam or bituminous macadam surfaces in area not exceeding 400 sqm and deep not exceeding 50 mm completed all as directed.
Premix bituminous macadam laid/rolled and compacted to reuired gradient and camber (consolidated thickness 75mm or less) with minimum 4% paving bitumen VG-30 grade by weight of total mix, mixed in hot mix plant, laid using sensor based mechanical paver, rolled with 8 to 10 tonne power roller and compacted to required camber and gradient complete all as specified and directed.
Applying evenly a priming /tack coat with bituminous primer using paving bitumen of VG-30 Grade at 10 kg per 10 sq mtrs complete all as specified and directed.
Preparing black top surfaces by brushing with wire brushed for removing caked mud etc sweeping with brooms finally fanning the cleaned surfaces with gunny bags to remove all loose dirt etc complete all as specified and directed.
Applying evenly a priming /tack coat with bituminous primer using paving bitumen of VG-30 Grade at 5 kg per 10 sq mtrs complete all as specified and directed.
Bituminous premix semi dense asphaltic concrete, 30 mm consolidated thickness with 5.5% binder content Paving bitumen VG-30 grade by weight of total mix, mixed in hot mix plant, laid using sensor based mechanical paver, rolled with 8 to 10 tonne power roller and compacted to required camber and gradient completed all as specified and directed.
Preparation of new or previously treated surfaces to receive the thermoplastic paste and marking of guide lines, dashed arrows, letters etc with reflective thermoplastic paste 2 to 2.5 mm thick using fully automatic tharmoplastic paint applicator machine fitted with profile shoe, glass beads dispanser, propane tank heater and profile shoe heater driven by experience operator, white, golden, yellow colour as required using glass beads necessary for achieving reflection on roads pavements and the like as per BS 6088 complete all as directed. Note : 1. Unit rate quoted by the contractor include for provision of red signals to keep off trafic from work, cleaning road surface and working during odd hours when traffic is light. 2. The line marking shall stand out boldly and solidly without showing any signs of scratch marks or surfaces underneath, if necessary the surface shall be remarked after removal of existing treatment untill the desired result is obtained.
Demolition of stone masonry laid dry in edging along the road complete all as directed.
Precast cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as in kerb stone with plain fair faces including chamfers, weathreing, throating etc and set joined and pointed in cement mortar 1:6 complete all as specified and directed.
Demolition of brick work/ PCC block masonary built in cement mortar complete all as directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for coping, benching and bed/foundation concrete etc complete all as directed.
Precast cement concrete 1:3:6 type C1 using 20mm graded crushed hard granite stone aggregate block masonry with solid block exc 10cm width & setting in CM 1:6 complete all as specified and directed.
Cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of drains etc complete all as specified and directed.
Providing cement concrete type C-1, 1:3:6 (using 20mm graded stone aggregate) in bed blocks, coping etc including necessary formwork complete all as specified and directed.
Rendering 15mm thick in CM 1:6 on brick or concrete surfaces and finished even & smooth without using extra cement complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth getting out in hard/ dense soil complete all as directed.
Returning, filling in including spreading watering and well ramming in layers n.exc 25cm thick in hard/ dense soil complete all as directed.
Demolition and breaking up drain pipes 300mm internal dia of pipe (Salt glazed ware AC or reinforced concrete) set in cement mortar complete all as directed.
Providing plain cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) as in bed to drain pipes of 300mm bore including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Reinforced concrete pipes dia 300mm class NP3, laid and jointed complete with collars complete all as specified and directed.
Removing excavated soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.50m above the starting point complete all as specified and directed.
PATEL CONSTRUCTION
PRACHANIVA CONSTRUCTIONS
G VENKATESH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .