Construction of Alaboi Ron Smriti Khetra in the Kamrup District
2022_PWBNH_27376_1
CE/TB-VI/58/2022/02 Dated Guwahati 12th Oct 2022
Open Tender
Civil Works - Building
910 days
Kamrup
Please refer Tender documents.
4 documents required · 4 mandatory
₹30,000
₹2.4 Cr
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
29 Mar 2023
15 Oct 2022
21 Nov 2022
15 Oct 2022
19 Nov 2022
22 Oct 2022
21 Oct 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 1.5m to 3.0 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 3.0m to 4.5 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 4.5m to 6.0 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 6.0m to 7.5 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 7.5m to 9 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary rock 9m to 10.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil
Providing hard stone soling of required thickness (or as specified in drawing) in layers not exceeding 20 cm in depth under foundation,flooring,under pavement,under plinth protection,under ramp, consolidating each deposited layer by ramming, watering and rolling with ½ tonne roller or wooden or steel rammers where ever required including preparing of surface etc. complete as per the direction of Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:4:8 (1 cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size drived from natural sources).
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg /cum
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Shelves (Cast in situ)
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for all heights :Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level. Concrete of M30 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement , admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site of laying, curing, carriage for all leads, but excluding the cost of centering, shuttering , finishing and reinforcement as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 330 kg/cum
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 600 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).
Providing and laying autoclaved aerated cement blocks masonry with 100/115 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Coursed rubble masonry (first sort) with hard stone in foundation and plinth with : Cement mortar 1:6 (1 cement : 6 coarse sand)
Coursed rubble masonry with hard stone (first or second sort) in superstructure above plinth level and upto floor five level. Masonry work (first sort), in cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for coursed rubble masonry with hard stone (first or second sort) in: Square or rectangular pillars
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of Slab over 0.50sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Polishing in high gloss/matt finish melamine matt clear polish on new wood work in required colour/wooden shade texture with following process in the sequence as detailed. 1st the surface to be polished is to be sanded with sand paper 80no./120no. And then sanding with sand paper of 160x180 nos. Applying sealer coat with brush or spray gun which is allowed to dry for 8 to12 hours. on drying of sealer coat wet sanding with emery cloth of finer grating with ample water id done so as to remove excess sealer layer and make the surface further smooth after this wet sanding the surface is applied with special grade melamine filler so as to fill all the small and big holes/grooves etc. filler coat dries in 4 to 6 hr on which again a light wet sanding is done and this surface is allowed to dry for 12 hrs.On this 1st coat of melamine polish is applied using malamine and hardening compound in light proportion using melamine thinner.As far as possible this coat shall be done with compressor pressure air gun. This 1st Coat is allowed to dry for 12 Hrs. On drying the final Melamine polish is applied with compressor pressure gun using melamine and hardener is right proportion. Final coat may be in 1 or 2 layer but care should be taken that it is not overdone.
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 160 mm
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. 10 x 60 mm
Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : 2nd class teak wood 50 x 20 mm
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick.
Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square
Providing and fixing of Wooden Fire door at all levels from ISO 9001:2015 certified Manufacturer . All Fire doors must satisfy the requirement of latest NBC 2016 Part 4 for Fire & Life Safety guidelines for 120 minutes Fire Rating with minimum 20 minutes Insulation properties along with its Stability & Integrity for 120 minutes. However Wooden Fire door carries 120 minutes Insulation properties . The Prototype sample of the door must carry a prior test evidence as per IS 3614 part-2 / BS 476 Part 20 & 22 . The manufacturer must submit the copy of test evidence prior to start of production .The offered test certificate should either carries it's Validity or certificate must not be older than 5 years from CBRI / NABL Accreditated Lab . Door frame shall be Single rebate profile of section 120 x 70 mm made out of Hard wood - Red meranti with factory made groove of suitable size so as to accomodate Fire & smoke seal of size 20x4mm . The frame must be primed with Fire retardant primer FR880 . Wooden shutter must be of minimum 52mm thickness finished with commercial ply on both faces. The commercial ply must be finished with Fire retardant primer FR880 . The Commercial ply may also be pasted with Laminate in desired shade (payable in extra item) . The composite thickness of the core insulation will be 44mm consists of Calcium Silicate boards and treated wool Insulation material . The shutter should be provided with heat activated intumescent fire seal strip of size 20mm x 4 mm mounted in the suitable grooves all three sides except bottom provided on Exposed wooden lipping . Vision panels wherever required should be of 120 minutes fire rated clear non-wired type. All hardwares , Fasteners and FR Glass shall be payable in Extra item. VISION PANEL Supply and fixing of Interlayered FR Glass of Saint-gobain, Pyrobeck ,Glaverbel or equivqlent make minimum 11 mm thick interlayred , 120 minutes fire Rated (EW120, EI 20 minutes ) Non Wired, Toughened Interlayered Glass of approved make and is to be fixed in between the glass beading by using ceramic fiber of size 350 mm x 350mm (Clear vision ) and the manufacturer should have tested the similar glass of similar size or bigger size . The Location of the Fr Glass will be as per the directions of Engineer-in-charge ( Actual supplied Glass size will be meaured for payment).Rate should include supply and installation of door and hardware as per application. Double Leaf Door With Hardwares ( 8 Nos. Hinge+ 2 Panic Bar+ 2 Door Closer+ 2 Fire Glass of size 350x350 With fixing minum 9 Fastners)
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade Godrej CYLINDRICAL LOCKS - CLASSIC LOCK Model no 5808. Complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300 mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete..
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.
Providing and fixing approved brand and manufacture SS 304 grade Top & Bottom Patch fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade H type 900mm Pull Handle with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Floor spring (weight approx 100-120kgs) fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge
Automatic Sliding Door- Frameless Providing and fixing Automatic Sliding door operator, Make: dormakaba ES 200 Easy - 4.15 Mtrs Bi-parting Sliding System, compliant with European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested, tested according to the low voltage guidelines, production according to ISO 9001:2000 certification, fulfils DIN18650 Standards for Pedestrian Safety, TUV Design Tested for Durability of 1 Million Cycles, for frameless glass door application, modular design including internal cover. and with 12 mm clear toughened glass for 2 Nos sliding door panel, Operator to be mounted on MS-Box Section/ Equalant. Operator Finish should be Silver Anodised E6/C0, with operator dimensions Maximum (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. The track profile should be separate from the main profile for enabling reduction in vibration insulation and easy maintainence. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20. Activators- dormakaba Nemo Motion + Nemo Dual ( Safety& Motion), EM Lock - Fail Safe and 5 Position Program Switch.The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below: Clear Passage Width = 700 - 2000 mm Max Clear Passage Height = 3000 mm Max Panel Weight Double Sliding = 2 x 100 Kgs. Max Panel Weight Single Sliding = 1 x 120 Kgs
Toilet Cubical Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard. This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Designing, Providing, installing and fixing factory finished customed design pregalvanized high tensile steel joists manufactured from G350 Z275 confirming to IS:277-1992, minimum coating of galvanizing 275 gm/sqm, minimum yield stress 35 MPa & minimum tensile strength of 380 MPa placed 1.23 metre apart to support the load of slab etc as per the design & directions of Engineer-in-Charge.
Providing and fixing of Glass Railing NCL OZRCL-125mm (H) x 57mm (W) Aluminium 6063 grade, Anodized with 12 mm toughened glass , OZRAC-UTB-40X40 top rail of Stainless steel with OZRAC-GKT-11 EPDM and necessary fitting woth grouting chemical fasteners complete with installation. all as per manufacturer’s specifications and Engineer Incharge’s directions complete in all respects.
Providing and fixing of Laminated Glass (8mm Toughened Glass + 2.28mm PVB + 8mm Toughened Glass + 2.28mm PVB + 8mm Toughened Glass) complete with installation. all as per manufacturer’s specifications and Engineer Incharge’s directions complete in all respects.
EXTERNAL : KLIPPON SMP COATED GALVALUME STEEL. INTERNAL : HI-RIB SMP COATED GALVALUME STEEL. Supply of Double Skin Insulated roofing system comprising external sheet of Klippon profiled sheeting 406 mm cover width, 41 mm crests @ 203 mm c/c manufactured out of 0.58 mm TCT (total coated thickness) SDP coated Galvalume (275 Mpa yield stress) steel. The sheet shall have wide pans with stiffening ribs for effective water shedding and special male/ female ends on sidelaps for purlin support and anti-capillary flute in side lap. The sheet shall have a hot-dip metallic coating of zinc aluminium alloy coating mass total of both sides, AZ- 150 as per AS-1397 ) having 275 Mpa yield stress. The sheet shall be coated with exterior coat of Silicon Modified Polyester paint, 20 microns top coat applied over 5 micron primer and conversion coat and a 5 micron polyester back coat. The external sheets shall be fixed to G.I sub-girts with clips and no fasteners to penetrate the sheeting. The clip should lock over the male rib and into the underside of the centre and female ribs and shall be fastened to support with wafer-head self-drilling zinc coated fasteners. The internal sheeting shall be Hi-Rib profiled sheets manufactured out of 0.50 mm TCT SDP GALVALUME Hi-Tensile Steel (150gsm, zinc aluminum alloy coating mass total of both sides,AZ-150 as per AS-1397 ) having 550 Mpa yield strength. The sheet shall be coated with exterior coat of Silicon Modified Polyester paint, 20 microns top coat applied over 5 micron primer and conversion coat and a 5 micron polyester back coat. The sheets shall have 1020 mm cover width, 28-30 mm high crests at 250 mm wide pans with special male/female side-laps and anti-siphoning feature to prevent leakages. The pan shall be stiffened by using 3 small ribs. The Sub-Girts Of Size 50mm X 50mm X 50mm X 1.6mm Manufactured Out of 18(G) G.I. ‘ Z ’ Shape would be fixed to Inner liner on face Side at Purlin Locations by means of Galvanised Self Drilling self tapping fasteners thru the crest. An Insulation of 50mm thick glass wool insulation16 Kg/M3 - Density wrapped in polythene bags shall be laid over the internal sheeting and G.I. sub girts are held between the external and internal sheets. The sheets shall be supplied in lengths maximum upto 6 - 12 metres to suit site dimensions. all complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia 4 mm
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required.
Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying FULL BODY HOMOGENOUS VITRIFIED TILES in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours, shade and design pattern, in flooring, skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints etc. all complete as specified and as directed by the Engineer-in-Charge.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
Extra for pre finished nosing to treads of steps of Granite stone.
30 mm thick Tandur stone slab flooring (Antique Finish) over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
30 mm thick Tandur stone slab flooring (Short Blasted and Diamond Brushed) over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab.
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Wooden flooring
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Wooden flooring Skirting same as above
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-incharge. Floor strip on edges 20% of Wooden flooring
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
38 mm thick wood block flooring of first class teak wood laid over 25 mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size) to be paid separately, coated with a thin layer of hot bitumen penetration 80/25 (blown type) @ 2.45 kg per sqm, including fixing blocks in position after dipping in hot bitumen (blown type) up to half depth, planed, levelled smooth and finished complete.
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone
40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. White sand stone
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and fixing 18mm thick Granite stone work for wall lining upto 10 m height in cement mortar 1:3 (1cement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction of Engineer-in-charge.
Providing and Fixing of “ FAVETON TERRACOTTA-Bersal” Made in SPAIN” Tiles, dimension 300 X 1200 X 16m.m. and Metal substructure including Aluminum T-Profile, horizontal profile, square tube L- Angle, Galvanized Brackets fasteners and SS Screws etc. resistance to impacts (classification as per P08- 302) with wind resistance to positive/ negative pressure 7000 / 5500 Pa, weight of approx. 32 kg per m2 which conform to standard NF EN 539-2, water absorption to be between 3% - 5% conforming to EN ISO 10545-3 § 5.1.1, bending strength not to exceed 1503 Newton conforming to EN ISO 10545-4. Installation of Bersal terracotta panels to be done by securing to the vertical Rectangular Box Profiles using the fixing clips 300mm per tiles fastened with 2 selftapping stainless steel screws. Vertical aluminum Rectangular Box Profiles are to be prepunched hole with vertical spacing of 25mm. The terracotta tile is to be well-supported on four points by the clips and on its two smaller sides by the rubber gasket so as to have a very good wind load resistance of more than 7000 PA positive wind load pressure and a negative wind load pressure of 5500 PA and flexural strength of 150 da N. The total thickness Bersal cladding system are not to be more than 110 mm. Tender specification text for framing & installation for Bersal (FAÇADE TILE) Vertical spacing of 1200mm to be set between vertical aluminum Rectangular Box Profiles. Horizontal and vertical lines to be drawn as fixing references. Supporting brackets to be set up and fixed in a staggered way along Rectangular Box Profiles’ fixing line. Brackets’ depth to be adapted as per site. The vertical Rectangular Box Profiles to be fixed in the brackets and profiles’ to be adjusted vertically so all profiles are to be on same vertical plan. Fixing clips to be screwed on the Rectangular Box Profiles. The Bersal terracotta panel is to be positioned in level and panel’s back face grooves to be inserted onto the clips. Panel installation to be done from bottom to top all complete as per Engineer in charge.
Designing, fabricating, testing, installing and fixing in position Rustic Corten Steel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panel cladding in pan shape in rustic colour of approved shades made out of 6mm thick corten steel panel material as specified using stainless steel screws, nuts, bolts, washers, cleats, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area shall be measured in sqm. up to two decimal places.
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. Red sand stone
Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 30 mm thick White sand stone - Exposed face machine cut and table rubbed with rough backing.
12 mm cement plaster of mix : 1:6 (1 cement : 6 Course sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement : 6 Course sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Providing & fixing 150mm wide Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer-in-charge.
LIME PLASTER Providing and applying MARMARINO PASTE FINE : : Approved Shade or equivalent approved make Application Process/ Methodology 1. Sanding the existing Surface with Sand paper. 2. Marmarino Bond Primer applied with Roller and Brush. The purpose of water redispersal polymer and vinyl acrylic acrylic primer is to reduce the absorption of the surface & create bonding between both the materials & act as water proof agent. 3. Minor Repair check ( As required) With Exterior grade Putty or black cement mixed with Masonry primer . 4. Sanding with sand paper 5. Priming on the repaired Surface. 6. Two coat of Marmorino ( Paste Fine) in approved shade.& buffing with SS Steel Trowel. 7. One Coat Of Water Base Protection Coat ( Ext) which act as anti-efflorescence & to avoid fading. The product has anti fungal , breathes out trapped moisture, flexibility & elasticity, long shade life for the shades made of ignorance pigment, water repellent, VOC in permissible limit etc., all complete as per directions and approval of Engineer-in-charge.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge.
Grading roof for water proofing treatment with Cement mortar 1:4 (1cement : 4 coarse sand)
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75 x75 mm deep chase
Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck , using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturer's specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R- 2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm.
Polyurethane based waterproofing system for podium and landscape decks. Base preparation 1. Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialized non shrink grout, coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing. 2-Bore Packing /Core cut treatment Providing and sealing the gaps in the core cuts around PVC pipes treated with epoxy bonding agent & sprinkled sand; using a non shrink grout , followed by sealing of the same joint by using 2 coats of waterproofing coating & Joint Tape. 3-Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with SBR 45 at dosage of 4Ltr per 50kg cement. (cement and sand shall be supplied by the main contractor) 4-Application of Primer: Apply Epoxy based primer over well prepared surface at 150-200 gm per Sq.Mtr. 5- Providing and applying Single component moisture cured polyurethane Elastomeric liquid water proofing coating [email protected] kg/sq.mtr to achive a DFT of 1.5 mm over the entire horizontal area extending upto 300mm on the parapet wall and then terminated. Sprinkling quartz sand @ 200 gm/m2 while second coat of PU coating is still tacky for providing mechanical grip to facilitate installation of plaster on the veriical walls. The membrane will have the following technical parameters: Tensile Strength : 2 N/mm2(ASTM D412) Elongation at break : 500 % (ASTM D412) Punture resistance : 90 N (ASTM D 4833) Adhesion to Concrete: >2.0 N/mm (ASTM D 903) 6- Providing and laying 150 Gsm Geo fabric membrane as separation layer 7- Protection Screed:Horizontal Areas: Providing and Laying M20 grade screed concrete in 1:100 to a minimum thickness of 75 mm mixed with Integral Waterproofing admixture at the dosage of 125 ml/bag of cement. 8- Providing and installing Drain board as a soil filtration cum drainage media before soil filling.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick
Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation.
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portion Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). Powder coated aluminum (minimum thickness of powder coating 50 micron)
Providing and fixing Single Glazing 6mm thick ET 125 series (Saint Gobain) toughened glass complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor ≤ 0.45, U-Value ≤ (W/sq.m-K) 5.7W /M2K, Visible light transmittance ≥ 0.30)
Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in- Charge.
Providing & fixing access panel is made out of Moist Bloc (Moisture Resistant) board for opening 600 x 600mm of thickness 12.5mm. All edges of the panel are reinforced with aluminium profiles and corners are guarded with stainless steel 304 grade clips to increase strength and prevent damages. complete in all respect as directed by Engineer-in-charge.
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): Flat surfaces
Supply & Installation of Luxalon® Heartfelt® Acoustical baffle linear felt linear box shaped panel Ceilings system made from non-woven thermo-formable virgin PES fibers. Dimension (bxh) 40mm x 55mm with an open joint between the panels. Panels are with the upper flanges pointing inward and the same is supported by the prongs on the inner corner of the flanges and not by the edges of the flanges and . Max Panel length can be provided from 1000mm upto 4000mm.Panels to be coupled in longitudinal direction by means of panel splices. Panel Carriers are made out of 0.9mm thick AA5052 Aluminium are available in natural finish 7178 or black 1863.). Carriers will be joined by means of carrier splices. Carriers provided with prongs to hold panels in 70mm Module . Carriers are fixed to the subframe using a suitable wall bracket. Edges of panels that are exposed to be covered with the same material. Fire Rating : classB ,s1,d0 according to EN 13501-1Mode of Measurements: Measurements shall be wall to wall without any deductions for lights, diffuses, columns etc. Approved Make List: Hunter Douglas, SAS, Gordon Inc.
Providing and fixing U Baffle Aluminium panel ceiling (M/s Hunter Douglas or Equivalent) consisting of Wood finish panel size 30 mm width X 100mm deep using 0.6mm thick, panel length upto 4 mtr, Coil Coated on a Continuous Paint Line, Double baked and roll formed from enamelled corrosion resistance Aluminium alloy AA 3005 (Al. Mg) for higher strength and good roll forming characteristics. Panels shall be clipped to a baked enamelled Aluminium carrier of 30 mm wide x 47 mm high x 0.5 mm thick, Black Colour coated, one leg of the carriers with cut outs to hold the panels in a module of 150 mm. Panel carrier shall be suspended by means of threaded rod at a distance of 1.8 mtr c/c. Aluminium panels shall be chromatised for maximum bond between metal and paint enamelled twice under high temperature, Exposed side with a full primer and finish coat on a Continuous Paint Line. Ceiling area above U Baffle to be painted in black colour before fixing this system (Cost of black paint shall be paid separately).
Providing and fixing of Harsons Green Aluminum perforated Post coated Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing wall angle of size 20x20 mm made of 0.4 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to center, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1200 mm c/c. Clip in profile main runner having height of 40 mm and width of 19 mm made of GI steel 0.5 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 1200 mm centers with help of suspension brackets & with L profile size of 24x24x0.40mm. Wherever the main C carrier and Clip in Profile have to join, C carrier and Clip in Profile connectors have to be used, fixing with clip in tiles into Clip in Profile with : Aluminum Metal Ceiling Clip in perforated Beveled edge global white color tiles of size 600x600 made out of 0.7 mm thick, The tile shall be fabricated from aluminium alloy AA 31005, The tiles shall be bevelled edge, and 20% perforation area with 1.8 mm dia holes The tiles shall have black tissue on back of side having 0.5 to 0.7 NRC value.and with Antimicrobial 60-micron powder coating activity using Test Based on MOD ISO 22196:2011. Powder coating test result should pass, Pencil hardness ASTM D3363-05, Scratch resistance ISO 1518-1/ SIS 83 91 17, Impact resistance ASTM D2794, Resistance to neutral salt spray ASTM B117, Resistance to humid atmospheres ISO 6270-2, Adhesion ISO 2409. Mode of Measurements: Measurements shall be wall to wall without deductions for Lights, diffusers, columns etc.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, ptimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineerin- charge.
Providing and laying 125 micron thick Membrane of impermeable plastic sheeting
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine
Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete New work (Two or more coats)
Grass Pavers Providing placing & fixing Precast Concrete Grass Grid Pavers of 70 mm Thickness and appropriate size, laid over compacted earth and over 75 mm thick layer (average) of fine sand, manufactured by using M-30 grade of concrete by using vibro compaction process using accurately designed moulds. The Grass Grid pavers shall be suitably reinforced etc. complete in all respects as per direction of the Engineer-in-charge.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge).
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge
Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Providing construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine complete as per direction of engineer-in-charge.
Providing and filling in position bitumen mix filler of proportion 80 kg. of hot bitumen, 1 kg. of cement and 0.25 cubic metre of coarse sand for expansion joints.
Supplying and laying of Uni-Axial Woven Polyster Geogrid conforming to MORTH 3100 and IRC113, as soil reinforcement/basal reinforcement including accessories like tie-strips, nuts & bolts and loops/lugs for joining reinforcing elements with the facia pannels, overlaps and other protective elements for synthetic geo-grids and all other activities required for reinforced soil walls, slopes etc complete as per design requirements, manufacturer specifications and as per direction of engineer-in- charge. Uni Axial Woven polyster geogrid of minimum tensile strength 80 KN/m in the Longitudinal direction and 30 KN/m in the Transverse direction.
Slit Drain Providing placing & fixing Precast Concrete Slit Drain (a) 1000 mm (Length) X 250 mm (Width) X 250 mm (Height), Drain diameter 150 mm, Slit width (20 mm) Manufactured with M - 30 grade of concrete by vibro compaction process with the following specifications: complete in all respects as per direction of the Engineer-in-charge.
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 20 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm
Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 4.75 mm
Fine dressing of the ground
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately).
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge..
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 60 cm dia, and 60 cm deep.
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 45 cm dia, and 45 cm deep.
Providing and fixing M.S. flat iron tree guard 60 cm dia and 2 m high, above ground consisting 4 nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm 2 m long verticals M.S. flats, riveted to 3 nos 25 x 6 mm M.S. flat iron rings in two halves, fixing together at site with required six numbers of 8 mm dia. and 30 mm long bolts, including painting two coats with synthetic enamel paint of approved brand and manufacture over a coat of primer. One name plate of 1 mm thick M.S. sheet of size 250x100 mm shall be welded to the tree guard near the middle height and lettered CPWD / PWD/ any other approved name. The tree guard shall be suitably fixed to the ground by embedding four legs of tree guard in pits of suitable dia and to a depth of 25 cm, refilling the pits with soil and ramming, complete in all respect as per satisfaction and direction of Officer-in-charge.
Providing and displaying of Philodendron Xanadu having 15 to 20 leaves, well developed with full of fresh & healthy leaves in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and Displaying of Spathiphyllum (peace lily), having 15 cm to 25 cm ht. blooming stag with fresh & healthy foliage well developed in 15 cm of Earthen pot/plastic pot as per direction of officer-in-charge.
Providing and stacking of Asparagus sprengeri of height 30 cm to 45 cm, full of leafy branches in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge..
Providing and stacking of Aspidistra, having 10 to 15 leaves well developed with fresh & healthy in 25 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Ophiopogon jaburan (variegated ), full of variegated leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Schefflera green, having 3 to 4 branch, ht. 30 to 45 cm well developed with fresh & healthy in 20 cm size of Earthen Pot/ Plastic Pot as per direction of the officer-in-charge
Providing and stacking of Setcreasea purpurea full of variegated leaves in 15 cm size of Earthen Pot/Plastic Pot as per direction of the officer-in-charge.
Providing and stacking of Syngonium variegated,of height 20-30 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge.
Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Alstonia scholaris of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Chorisia speciosa of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Chukrassia tabularis of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Heterophragma adenophyllum (Marore fali) of height 150-165 cm. in Big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Mimusops elengi (Maulsri) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Spathodea campanulata of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Lagerstroemia speciosa of height 240-300 cm. in big poly bag of size 7.5-10 cm as per direction of the officer-in-charge.
Providing and stacking of Agathis robusta of height 300-360 cm. in big poly bag of size 7.5-10 cm as per direction of the officer-in-charge.
Providing and stacking of Erythrina crista-galli of height 240-300 cm as per direction of the officer-in-charge.
Providing and stacking of Gmelina arborea of height 240-300 cm and 100 mm trunk dia as per direction of the officer-in-charge.
Providing and stacking of Toona cilliata of height 210-240 cm as per direction of the officer-in-charge.
Providing and stacking of Terminalia chebula of height 240-300 cm as per direction of the officer-in-charge.
Providing and stacking of Artocarpus heterophyllus of height 240-300 cm as per direction of the officer-in-charge.
Providing and stacking of Mesua ferrea of height 180-210 cm as per direction of the officer-in-charge.
Providing and stacking of Callistemon lanceolatus of height 300-360 cm and trunk dia 7.5-10 cm as per direction of the officer-in-charge.
Providing and displaying of Areca palm having ht. 1.50 m to 1.80 m with 6 to 8 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge..
Providing and displaying of Dracaena Marginata having ht. 30 cm to 45 cm with colorful leaves, fresh and healthy in 20 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
Providing and displaying of Livistona palm having ht. 60 cm to 75 cm, well developed with 8 to 10 leaves, fresh & healthy foliage in 30 cm size of Earthen pot/Plastic pot. as per direction of the officer-in-charge.
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Furcaria Variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35 cm Cement Pot as per direction of the officer-in-charge.
Providing and Displaying Washingtonia filifera palm well developed 90 to 105 cm ht. having 5 to 6 straight fresh and healthy leaves in 35 cm Cement Pot as per direction of the officer-in-charge
Providing and stacking of Clerodendrum inerme of ht. 20 cm to 30 cm multi branched in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge.
Providing and stacking of Calliandra hybrida of height 75-90 cm. with 4-5 branches in bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 60-75 cm. with 6-8 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Hibiscus rosasinensis of height 60-75 cm. with 5-6 branches in p.bag of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and Stacking of Ficus panda plant of height 90 -105 cm. multibranches, well developed in poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work : 150 mm nominal dia Pipes
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 1729
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality H D - 20 Circular shape 560 mm internal diameter
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing, Fabrication, Erection and Installation of 30-Meter High Sword (Including pedestal) at Alaboi Ron Smriti Khetra. 30-Meter High Sword consist of Bronze and Stainless Steel cladding. Bronze Work for Sword Handle, approximate weight of bronze Handle to be 9.5 Tones with average thickness of Bronze Cladding Shall be 6-8mm thick whereas Stainless steel Part of Sword skin of avg 3mm thick sheet SS 304 Grade Sheet with approximate weight to be 12 Tones, cladded on steel armature of Steel structural for the statue space frame members supporting the exterior cladding as per Technical specification and vetted design and model to be commissioned with all incidental expenses such as wind tunnel test (consisting of wind climate analysis, proximity model and structural wind load study thru RWDI or equivalent agency) complete in all respect with complete mechanism of maintenance and monitoring etc. (Bronze weight approximately 9.5 Tones) (Stainless Steel approximately 12 Tones) Note : The quantites provided below are indicative, Contractor need to verify and analyse the indicative quantities as per design intent before quoting the price and item of one job to be treated as design build with wind tunnel test and all incidental expenses if any required to complete the statue complete. Nothing extra will be paid other than quoted one job price. In any case excess quantity is not payable, however any saving in quantity of steel and bronze will be deducted as per quoted price. During execution of the work, running bill payment will be regulated on prorata basis. Cost of pedestal will be paid as per tendered item. The cost of Bronze Statue Includes. a)Artist Sculpture Design & Modelling charges for 30-Meter High Sword (Including Pedestal) b) 30-Meter High Sword (Including Pedestal) of Lachit Borphukan c) SS Steel Structure to Support 30-Meter High Sword d)Installation charges of Bronze & Stainless Steel parts at site e)Transportation charges f)Providing & Fixing Double scaffolding system g)Hire charges of Tower Crane (90 days) h)Cost of Wind Tunnel test i)Preparation of scale Sword in thermocol. j)Bronze & Stainless Steel casting of Sword panels. k)Welding of 1:1 scale bronze & Stainless Steel Sword in Foundry, l)Final finishing of bronze & Stainless Steel Panels of Sword at site. m)Final painting with PU paint (metallic bronze shade).
Providing and fixing of white vitreous china wall hung / floor mounted European type water closet of approved shape and size with inside glazed P trap, with concealed flushing cistern dual flush capacity of 2.1 / 4.2 LPF including soft close anti-bacterial seat & cover infused with nano silver ions (AG+) for 99.9% bacteria protection along with hinges & rubber buffers, CP brass screw, washer with all associated accessories with side gap filled with silicon sealant wherever required complete including cutting and making good the walls, floors, slab wherever required complete. Wall Hung WC with seat cover Make Kohler Model No K-26994IN-0 + Concealed Flushing Cistern Make Kohler Model No K-26353IN-M-NA + Face Plate for Cistern Make Kohler Model No K-75890IN-P-BN + W.C Pan Connector Make Kohler Model No K-1046327-S + W.C Chair Bracket Make Kohler Model No K-1225108-0 or Equivalent.
Providing and fixing white vitreous china wash basin of approved shape and size with special fabricated brackets duly painted white, faucets as required, 32 mm C.P. brass waste.32 mm C.P. brass bottle trap & pipe to wall with rubber adopter for waste connection and C.P. brass wall flange complete in all respects including cutting and making good the walls where required. Counter Top Wash basin Make Kohler Model No K-28782IN-0, 32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP, Soft Press Basin Faucet Make-Kohler Model K-20747IN-8-CP or Equivalent.
Counter Top Wash basin Make Kohler Model No K-28782IN-0, 32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP, Basin Mixer Make-Kohler Model K-23483IN-4-CP or Equivalent.
Providing and fixing white vitreous china urinal of Make Kohler Model-K-16321IN-SS-0, including fixing to wall with suitable brackets, urinal sensor Make- Kohler Model- K-24199IN-C03-CP,32 mm CP brass waste Make Kohler Model No K-45432IN-CP, 32 mm C.P. brass bottle trap with pipe to wall and C.P. wall flange Make Kohler Model No K-75823IN-CP or Equivalent. complete including cutting and making good the walls and floors where required.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink single bowl with single drain board 1220 x 510mm, bowl depth 200mm with mat finish Make Jayna Model-SBGB 02 , Sink Mixer Make- Jayna Model-SF O1 or Equivalent.
Providing and fixing Stainless Steel Waste pipe for sink including waste fittings complete. 40 mm dia.
Providing and fixing brass toilet paper holder Kohler Model. No. K-25346IN-BN or Equivalent. including cutting and making good the walls wherever required.
Providing and fixing C.P. brass 15 mm nominal bore two way bib cock Kohler Model.K-20075IN-4-CP or Equivalent
Providing and fixing C.P. brass 15 mm nominal bore one way bib cock Kohler Model.K-20073IN-4-CP or Equivalent.
Providing and fixing C.P. brass 15mm nominal bore angle valve Kohler Model. K-80154IN-4-CP or Equivalent.
Providing and fixing C.P. cast brass twin coat hooks fixed to PVC rawl plug with SS screws Kohler model. No. K-25073IN-CP or Equivalent.
Providing and fixing health faucet with 1 m long flexible tube and wall hook including all fittings Kohler model No.K-12925IN-CP or Equivalent. .
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete in all respects. Make Jaquar Model. No.ALD-801B or approved equivalent.
Providing and fixing fully automatic Hand dryer Kohler Model-K-5486T-2-0P or equivalent. including all fittings complete in all respect.
Providing and fixing liquid soap dispenser including all fittings complete.Make Euronics Model-ES18 or equivalent.
Providing and fixing Aerosol Perfume Dispenser including all fittings complete.Make Euronics Model-EA03 or equivalent.
Supply of Stainless Steel Dust Bin.Make Kohler Model-K-17531T-STor equivalent.
Providing and fixing Swing Grab Bar Jaquar Model No. WAC-SAP-BG0800CS including cutting and making good the walls wherever required.
Providing and fixing Hand Rail Jaquar Model No. Grab Bar 842 mm Long, Satin including cutting and making good the walls wherever required.
Providing and fixing 150 litre/ hr. cooling and 150 Litres storage capacity,fully stainless steel electric storage type water cooler (Blue Star model No. SDLX 15150 or equvalant) with inlet hose connection inbuilt float valve. 2 Nos. outlet foucet, drain tray with waste and pipe up to fllor trap heavy compressor and wire up to socket, 3 pin plug etc complete in all respect.
Supplying, installation, testing and commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 150 litres / hour designed at a minimum Flux at inlet complete as required.
Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 25 Litres
Providing & fixing Centrifugally Cast (Spun) Iron Hubless Pipes & Fittings as per IS-15905, (plain or door of LH/ RH/ Rear as required as per site) e.g. bends, junction, offsets, end caps, including Stainless Steel (SS-304) Coupling with Electrometric Gasket (EPDM) as per ISO-6594 / DIN-19543 / ASTM / IS-15905 Standards, suitable joints with nuts and bolts, including cutting chase or holes in walls and floors and making good the same wherever required. 100 mm dia.
Providing and fixing trap of self cleansing design with screwed down or hinged with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS: 15905
Painting sand cast iron/ centrifugally cast (spun) soil, waste, vent pipes and fittings with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. 100 mm diameter pipe
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 32 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 40 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 50 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 32 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 40 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. 50 mm dia. nominal bore
Providing and fixing of GI split pipe support clamps with EPDM rubber lining, Zinc plated for support of vertical/hanging horizontal soil, waste, vent and rain water pipes, embedded in walls with anchor fastner, including recommended size GI threaded rod of required length etc. including cost of cutting holes and making good the walls complete in all respects. For 100 mm dia Pipe (Thickness of clamp 2.0 mm)
Providing and fixing of GI split pipe support clamps with EPDM rubber lining, Zinc plated for support of vertical/hanging horizontal soil, waste, vent and rain water pipes, embedded in walls with anchor fastner, including recommended size GI threaded rod of required length etc. including cost of cutting holes and making good the walls complete in all respects. For 150 mm dia Pipe (Thickness of clamp 2.0 mm)
Providing and fixing cast brass clean out plug with suitable insert keys for opening, male threaded joint with GI threaded socket caulked to CI soil pipe including cost of lead Joint. 100 mm dia
Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar.
Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar.
Providing and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2 or 3 inlets of 32 to 50 mmdia, fixed to CI trap with lead joint and set in cement concrete as per drawing complete.
Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement joint as per manufacturers' recommendations. [for Rain Water Pipes] 110 mm OD
Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g. couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement joint as per manufacturers' recommendations. [for Rain Water Pipes] 160 mm OD
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 32 mm nominal outer dia .Pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on Wall 40 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 25 mm dia nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 65 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 80 mm nominal dia Pipes
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 20 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 25 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :32 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :40 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :50 mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality :80 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 20 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 25 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 32 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 40 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work :65 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 80 mm dia nominal bore
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 65 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 80 mm dia
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 20 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 25 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 32 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects.40 mm nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female BSP threads complete in all respects. 50 mm nominal bore
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 20 mm Pipe
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 25 mm Pipe
Providing and fixing Thermoflex or Kaiflex thermal insulation tubing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) For 32 mm Pipe
Providing and fixing Flanged end CI digital water meter complete in all respect. 80 mm dia.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc, exceeding 80mm dia but not exceeding 300mm dia
Extra for every additional lift of 1.5m or part thereof in: All kinds of soil (Manhole)
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. 150 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. 200 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design. 250 mm diameter
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 Part-2 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. 150 mm dia.
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 Part-2 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. 200 mm dia.
Providing, laying and jointing HDPE Double Wall Coil (DWC) SN-8 Grade pipes confirming to IS: 16098 Part-2 including all fittings wherever required e.g., tees, bends of any degree, couplings, adapters, plugs, unions etc. and jointing as manufacturer recommondation etc. including testing of joints etc. complete. 250 mm dia.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.22m internal dia (at bottom) beyond 1.68 m to 2.29 m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing brick masonry circular manhole 1.52m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, all complete as per standard design : 2.30 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra depth for circular type manhole 1.52m internal dia (at bottom) beyond 2.30m : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50m. All kinds of soil Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia.
Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. 250 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) up to haunches of S.W/RCC pipes including bed concrete as per standard design. 300 mm diameter
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 300 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 450 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 500 mm dia. R.C.C. pipe
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 600 mm dia. R.C.C. pipe
Constructing bricks masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth beyond 45 cm of brick masonry chamber : For 455x610 mm size With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer –in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 400 mm dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia having minimum wall thickness 5.40 mm
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia
Providing and fixing 80 mm dia. GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete.
Supply, Lowering, installation & testing of KSB make submersible pumping set with 7.5 HP motor 4 stage pump suitable for 20/26/30/38/40/45/50 m3 hr. at 42/38/36/32/29/25/20 mtr. Head respectively. With Three Phase. (Model: 273/4)
Providing & fixing cable 6 sq.mm. From submersible pump to panel board.
Providing & fixing Panel Board for submersible pump fitted with DOL starter ammeter, voltmeter single phase preventer standard/indo/cop make MCB of off switch push bottom duly wired and made out of 16/18 SWG sheet.
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. 80mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. 80mm dia
Supply, installation, testing & commissioning of vertical inline multistage pumping set (Imported) with Stainless steel body, impeller, casing, shaft and C.I. base & head with mechanical seal, connected to a TEFC induction motor suitable for 415+/- 10% volts, 3 phase 50 cycles A.C. supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundations, 80x40 mm I section base plate bolted to cement concrete foundations complete.Vendor to submit performance curves and technical catalogue of the proposed model for review and information. Filter Feed Pump ( Dom. Water) at Water Supply Pump Room) Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 4.5 LPS Head 25 M. HP 3.0 HP Approxi.
Supply, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical inline multistage pumping set with Stainless steel-304 body, Stainless steel-304 impeller, Stainless steel-304 casing, shaft of Stainless steel-316 and C.I. base & head with mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 60 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,dual type pressure switch, complete in all respects, including suction and delivery headers of Stainless steel-316 grade pipe of required dia, isolation valves, NRV of PN-25 grade & vibration eliminators on both suction & delivery side of pumps,power box, equipped with fuses/ isolators/circuit breakers as required. The entire Hydropneumatic system shall be factory fitted. Hyd. System for Domestic Water Supply at Pump Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 5.0 LPS Head 35 M. HP 5.0 HP Approxi.
Supply, installing, testing and commissining of fixed speed hydropneumatic system mounted on a common base plate comprising of vertical inline multistage pumping set with Stainless steel-304 body, Stainless steel-304 impeller, Stainless steel-304 casing, shaft of Stainless steel-316 and C.I. base & head with mechanical seal, shaft directly coupled to a TEFC induction motor suitable for 400/440 volts, 3 phase, 50 cycles AC supply with 150 mm dia pressure gauge with gunmetal isolation cock, vibration eliminating pads under foundation, dry running Protection,motor control centre, necessary power and control cabling from MCC to pumps including required rating of MCB, one No. 60 litre capacity M.S diaphragam tank with interchangeable butyl rubber membrane,dual type pressure switch, complete in all respects, including suction and delivery headers of Stainless steel-316 grade pipe of required dia, isolation valves, NRV of PN-25 grade & vibration eliminators on both suction & delivery side of pumps,power box, equipped with fuses/ isolators/circuit breakers as required. The entire Hydropneumatic system shall be factory fitted. Hyd. System for Flushing Water Supply at STP Room Set of Two Pumps ( 1 Working+ 1 Standby) Capacity 4.0 LPS Head 35 M. HP 3.0 HP Approxi.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby) Pump Room Drainage Pumps (Pumps to be suitable to handle solids upto 12 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 1.5 HP Approx.
Supply, installing, testing and commissioning of submersible open impeller non-clog pumps with C.I.body and to TEFC submersible motor for 415 + 10% volts, 3 phase, 50 cycles A.C. power supply with mechanical seal, pump connector unit with rubber diaphragm and bend, vertical discharge pipe, guide pipe and chain in built level controller, sequence running controller, arrangement for both pumps together inacase of emenegency, audible hooter for failure or flooding, dry running Protection complete in all respects., painting, testing and commissioning complete with approved quality and make as required as per instruction of site incharge. (Pumps shall be installed in a set of two pumps One working and One standby) Sewage Sump Pumps (Pumps to be suitable to handle solids upto 40 mm size) Capacity - 4.0 LPS (Each) Head - 15 M H.P. - 2.0 HP Approx.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required. For Water Supply Pump: To start pump when water level is low in Domestic Water U.G. tank and shut off pump when Domestic Water U.G. tank is full. Also to stop when water level is low in raw water underground tank.
Supplying, installing, testing and commissioning controllers with low voltage relays, stainless steel probes and PVC shroud wiring from tank top to problems of required. For Sump Pumps: To start pump when water level is high in sump and shut off pump when sump is empty. Both pumps are start when sump is over flowing.
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. 50 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. 65 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. 80 mm dia
Providing and fixing GI pipes complete (IS:1239 Heavy Class) with GI fittings and clamps including MS pipe supports, enamel paint as per specifications cutting and making good the walls etc. complete. 100 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. 50 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. 65 mm dia
Providing & fixing butterfly valve tested to a pressure not less than 16 Kg/Sq.cm. Including rubber gasket, 2 nos. Table-E flanges, nuts, bolts, washers & painting complete as required. 100 mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. 50 mm dia
Providing & fixing dual plate CI wafer type check valve tested to a pressure of 16 Kg/sqcm. Including rubber gasket, 2 nos. table-E flanges, union, nuts, bolts, washers & painting complete as required. 65 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. 50 mm dia
Providing and fixing resilient rubber neoprene lined style arch vibration eliminators suitable for raw water upto 45 deg.C. Temperature working pressure upto 25 Kg/Sqcm. 65 mm dia
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. Power cable Copper 3 core 6 sq.mm
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. Power cable Copper 3 core 4 sq.mm
Providing and fixing heavy duty armoured cables 1.1 KVA grade including necessary support clamps at ceiling level and connection lugs complete in all respects. Control cable copper 2 core 1.5 sq.mm
Supply Installation,Testing & Commissioning of vertical self supporting Filter fabricated from MS sheet as per IS: 2825, (minimum thickness of shall 6 mm and dished end 8 mm)) pressure gauges, sample cock, GI class 'C' face piping, CI butterfly valves and all accessories , with initial charge of filter media including anthracite, painting inside with epoxy paint and outside with two coat of red oxide primer and two or more coat of synthetic enamel paint, testing and commissioning complete including CC foundation of suitable size. Dual Media Filter For Domestic Water Supply Capacity- 16200 LPH Filtration rate- 14000 LPH/Sqm. Filter dia approx. - 1200 MM Working pressure: 3.0 Kg/sq cm. Test pressure : 4. 5 Kg/sq cm
Supply Installation,Testing & Commissioning of metering pump type chemical doser with 200 lits. HDPE chemical grade solution tank,injection fitting assembly,suction and delivery hose upto the point of injection, capacity 0-12 lph, complete in all respects. Chlorination of Domestic Water
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 2280 LPM at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads. 180 LPM at 70 m Head
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a)Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. (b)Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d)Suitable cement concrete foundation duly plastered with anti vibration pads. 450 LPM at 35 m Head
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 80 mm dia.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 100 mm dia.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. 150 mm dia.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 32 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 40 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 65 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100 mm dia
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 80 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm dia
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm dia
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 150 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 40 m
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for nstantaneous connection to interconnect hose pipe coupling as required : Stainless Steel (Grade 304)
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way - 100 mm dia M.S. Pipe
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Upright Sprinkler
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 150mm dia
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 700 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1000 mm
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1200 mm
Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required.
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width x 50mm depth x 1.6 mm thickness.
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Providing and fixing MS partly glazed double hung lockable shutter fabricated from MS section as required with 5 mm thick glass for fire station complete including stove enamelled painting of door and frame and words "Fire Hydrant" written on glass, suitable to accommodate 2 Hydrant landing valves, 1 fire hose reel, 2 nos.15m long 63 mm dia hose,1-branch pipe, 1no. fire man's axe, fire extiguishers 2 nos, including suitably mounted on a raised masonry platform as required. (Approx.size 1.20 m x 2.1m )
Providing and fixing of Weather proof hose cabinets fabricated from 14 g M.S. Sheet with full glass door and mortise locking arrangement , suitable to accommodate one Hydrant landing valve, 2 nos. 15 M long hose and 1 No branch pipe. The cabinet shall be painted with one coat of primer and finished stove enamelled "Fire Red", "Fire Hose" written on front including suitably mounted on a raised masonry platform as required. (Approx 0.75mx0.6 m x 0.25 m).
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. 80 mm dia.
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. 100 mm dia
Providing and fixing resilient rubber neoprene lined single arch vibration eliminators with unit control suitable for raw water upto 450C temperature working pressure 25 kg and test pressure 37.5 kg/cm2. 150 mm dia
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3.5 core 95 sq mm aluminium conductor armoured cable
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Power cable 3 core 16 sq mm aluminium conductor armoured cable.
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs complete in all respects. Control cable copper 2 core 1.5 sq.mm
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length, discharge horn, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge (Halon Free Gas) Capacity 4.5 Kg.
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) Capacity 6.0 Kg.
Sewage Treatment Plant (SBR Technology) Supplying, installing, testing & commissioning of Sewage Treatment Plant of 250 m3/day based on SBR technology (excluding excavation, back filling & disposal of surplus earth MS / Civil construction work) for the following duty: Nature of Sewage - Domestic Sewage waste water shall be discharged into the STP. Design to take consideration of same. The STP design based on the following parameters: Daily average flow: 850 M3/Day PH : 6-8.5 BOD : 350 mg/l S. Solids : 500 mg/l COD : 450 mg/l Oil & Grease : 45 mg/l Sewage discharge standard after treatment :- PH : 6.5-7.5 BOD : Less than 20 mg/l After ozonator Less than 10mg/l S. Solids : Less than 10 mg/l COD : Less than 80 mg/l After ozonator Less than 50mg/l Oil & Grease : Less than 5 mg/l (a)Detailed GA drawing, flow diagram, equipment list, power load requirement- Job-1 (b)Design, calculations of all elements of the plant, electrical and mechanical work to satisfy adequacy of design- Job-1 (c)Submission of detailed GOOD FOR CONSTRUCTION' stage architectural, structural, construction, electrical, mechanical and piping drawing for approval. - Job-1 (d)Supply Installation Testing & Commissioning of 1 No. Manual Coarse Screen to Remove coarse material in the water by screen interception to protect the pipes and pumps from tearing and wearing. Size: 1000 mm X 1200 mm MOC : SS 304 (e)Supply Installation Teating & Commissioning of 1 No. Mechanical Coarse Screen to Remove coarse material in the water by screen interception to protect the pipes and pumps from tearing and wearing. Size: 1000 mm X 3000 mm MOC : SS 304 Type: Mechanically Cleaned. (f)Supply Installation Testing & Commissioning of 1 No. Manual Fine Screen to Remove fine material in the water by screen interception to protect the pipes and pumps from tearing and wearing. Size:1000 mm X 1200 mm MOC: SS 304 (g)Supply, installation, testing & commissioning of 1 Set Grinder/Cutter type Sewage Pumps having CI casing & CI impeller complete with foundation bolt and all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller to control the level for provision to control the level of sump automatically. Pumps shall have following duty: 2 Nos .(1W+1S), Flow Rate : 17 M3/Hr, Head : 15 mtr (h)Supply, installation, testing & commissioning of 1 Set non clogging type Submersible Sewage Pumps having CI casing & CI impeller complete with foundation bolt and all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller to control the level for provision to control the level of sump automatically. Purpose: For sewage transfer from equalisation tank to SBR reactor. Pumps shall have following duty: 2 Nos.(1W+1S), Flow Rate : 17 M3/Hr , Head : 10mtr, Solid Handling : 32MM (i)Supply, installation, testing & commissioning of 1 Set non clogging monoblock type Sludge Recirculation pump having CI casing & CI impeller complete with and foundation bolts all accessories, motor of required capacity. pressure gauge on delivery line with isolation cock, level controller to control the level of sump automatically. Purpose: For transfer sludge to Sludge holding tank and recirculation to SBR Reacter. Pumps shall have following duty: 2 Nos. (1W+1S) Flow Rate : 17 M3/Hr Head : 10 mtr Solid Handling : 8 MM (j)2 Nos. twin type Rotary air blowers (1W + 1S) capable of delivering of free air at 0.5 kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC motor of suitable HP Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply. Including foundation and foundation bolts work. Purpose: For air supply to equalisation tank/sludge holding tank/SBR reactor Capacity :- 400 m3/hr (k)Supply Installation Testing & Commissioning of 2 Nos. VFD for Air SBR Reactors with in all respect (l)Supplying, installing, testing & commissioning of Horizontal centrifugal non clog water pumps with CI casing and CI Impeller along with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, stainer (with by-pass) at suction. Mechanical seal, suitable vibration elimination pads of approved design,drain pipe with valve for the pump. The pump shall be suitable for 415±10% volts 3 phase AC supply. Including foundation bolts Set of Two Pumps (1 Working + 1 Standby) Filter Feed Pump ( Set-1) Capacity : 21 M3/Hr Head :25Mtr Treated Water Transfer Pump ( Set-1) Capacity :17 M3/HR Head : 10 Mtr (m)Supply, installation, testing and commissioning of Sludge Feed Pumps Screw type Complete with all fittings & accessories. Including foundation and foundation bolts.( 2Nos.- 1W+1S). Set-1 For Feed Sludge to filter press Capacity : 5 M3/H Head : 40mtr MOC :CI (n)Providing, fixing, testing & commissioning of vertical filter with adequate dirt holding capacity complete with intitial charge filter media, thickness 8 mm for dishes of filter & 6 mm for shell of Filter, Internal surface coating from epoxy and external surface coating with primer & enamel twice. The filter shall also be provided with set of internals for raw water inlet and bottom collecting system. Pressure Sand Filter ( 1 No.) Type : Down Flow Flow rate: 21 M3/hr Dia : 1400 mm Height: 2200 mm Filter Media: Sand & Gravel MOC: Mild Steel Activated Carbon Filter (1 No.) Type : Down Flow Flow rate: 21 M3/hr Dia : 1400 mm Height: 2200 mm Filter Media: Sand & Gravel MOC: Mild Steel (o)Supply, installation, testing & commissioning of 1 Set Poly dosing system comprising of 1000 ltrs HDPE/FRP tank with 0-100 LPH electronic metering type pump and SS agitator complete with motor.Purpose : For Thickening of Sludge (p)Supply, installation, testing & commissioning of 1 Set Chlorine dosing system comprising of 1000 ltrs HDPE/FRP tank with 0-100 LPH chlorine Dosing electronic metering type pump.Purpose : For Disinfection of water (q)Supply, installation, testing and commissioning of 1 No. Volute type screw disc press of particular size with all fittings & accessories .Purpose : For Sludge Drying.Sludge Capacity to Centrifuge :5 M3/Hr (r)Providing and fixing all piping MS C-Class (as described below) and isolation control valves- CI for making the system complete. 1 Lot- MS Epoxy : Submerged air piping 1 Lot - MS Epoxy : Air piping & pumped effluent riser (non-submerged) 1 Lot- MS Epoxy : Interconnecting pipe line after delivery header of pump/ filter 1 Lot- MS Epoxy : Pumped effluent (submerged) & tank overflow pipe line Purpose :- For Flow Control & Transfer path of Flow (s)Supply, instalation,testing and commissining of 1 Lot- MS puddle flanges in accordance to BS : 10 table D as required to be provided ( in the structural slab and wall ) of various diameters. Puddle flanges shall be provided for all the structural component of the STP. The installation of the puddle flanges shall be carried out by the Civil Contractor in accordance to the Civil GA drawings ( to be prepared by the STP contractor) at the required levels and position : under the supervision of the civil contractor. (t)Non clog, Self Cleaning type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per / meter water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. Course Bubble Diffuser = 30 Nos. Fine Bubble Diffuser = 60 Nos. (u)Supply, instalation,testing and commissining of 1 Lot- Motorised valve for decanter, distribution system and air dispersion grid as required for STP as described above (v)Supply, installation, testing and commissioning of 2 Nos.fully automatic SBR package, Automated system shall include Floating Decanter with articulated arm, stainless steel collector joint, knee joint, air compressure and flexible hose pipe. make a provision for auto air scoring specially for decanting machenism for self cleaning to avoid blocking in extraction nozzle , MOC should be SS-304 for decanted water extraction from SBR tank. Inlet of sewage water decantation and areation shall be automatic and PLC controlled with the help of automatic valves. SBR cycle shoul be auto control through PLC including air compressure for Decanter, ultrasonic water point control unit, Disolve oxygen transmeter, pressure gauge, Human machin interface shall be provide with PLC to make the system complete. (w)Approval from pollution board at initial & various other stages of works including preparation of report / drawings as per pollution board requirement. Contractor shall include the cost of all chemicals consumed during testing & commissioning and the cost of such items of works which are not explicitly mentioned above, but are mendatory to have pollution board approval. (Approval scope only related to STP works) (x)Supply, installation, testing & commissioning of 1 Set Ozone generator system comprising SS ventury, oxyzen concitrator, SS recirculation pump, ozone dosing asembly recirculation line comple with replacable ozone cell for suitable capacity. Flow Rate: 55 m3/Hr (y)Supply of 1 Set lab equipments for testing of parameters i.e. pH, TSS, BOD, COD, O&G and TDS (z)Suppy, installation, testing & commissioning of 1 Lot electro-mangnetic type flow meter at inlet of reactor tanks. Purpose : For Measure flow quantity with time. (aa)Supply, Installation, Testing & Commissioning of 1 Lot Water level controller for operation of the system connected to control panel for automatic switching ON / OFF of each pump. Purpose : For control Amount of Influent in tank (ab)Supply, Installation, Testing & Commissioning of 1 Lot pressure gauges with in all respect Purpose : For Measure & Indicate the pressure into vessel. (ac)Supply, Installation, Testing & Commisioning of 1 Lot PH Indicator with in all respect. Purpose : For measure acidic & alkaline nature of water (ad)Supply, Installation, Testing & Commissioning of 1 Lot Dissolved Oxygen meter with in all respect. Purpose : For measure oxygen level into reactor. (ae)Electrical Panel with PLC Control (af)Designing, Supply, instalation, testing & commissining of 1 Set PLC based control panel with interlocking arrangement with suction pumps,modulating or shut-off valves including necessary wiring, magnetic switches and sensors complete to make the system functional with following interlocking Construction: compartmentalized type skid mounted, MCC control panel will be free standing; vertical, fabricated from CRCA steel sheet 14/16 G conforming to degree of protection IP-52 or better. Cable entry will be from bottom. System Voltage: 380 to 410 Volts & 50HZ (415V +- 10%, AC, 50 HZ +- 5% for india) Surge protection to be provided at every applicable point. PLC: The programmable logic controller (PLC) shall consist of a PLC hardware, with 16K (min) program memory shall be protected by a backup battary with further memory protection from an EEPROM. HMI: 5.5 inch colour touch screen HMI, will be mounted on A Man-machine interface terminal (MMI) shall be mounted on the front of the main control panel for control of the activated sludge plant. It will provide a display of the process parameters and equipments status. The display will have an associated keypad. the system will allow operator changes to set points and control of equipments. The terminal shall include an alarm annunciation with a dedicated alarm page and allow acknowledgement of alarm. Electrical Motor Control Panel Design, supply, installation, testing and commissioning of 1 Set CPRI Approved STP Main Electrical Panel (MCC) housing with individual DOL starter of suitable capcity upto 10 HP motor and Star delta starter above 10 HP motor panels for various loads complete in all respects with suitable switchgear. It shall be provided with metering, ACB’s with S/C & O/L releases, MCCB Units, lamps, bus bars etc. The accessories used shall conform to the latest IS codes. The complete panel shall be complete Type tested Assembly panel. Sewage Treatment Plant as Descrbe Above
Ultrafiltration System - 18 KL/Hr - For Generating 180 KL Water for Flushing (a)Supply, installation,testing & commissining of 1 Set UF Module (Hollow Fibre -outside in type porocity 0.1 to 0.01 micron) including micron cartridge filter in PP housing, Pneumatic Valve, PLC Electrical Panel, flow meter, compressor and all other accessories making the system complete Flow rate : 18 cum/hr Output Inlet TSS :- 10-30 mg/lt Filtration Flux :- 45 lt/m2/hr Membrane Area - 64 M2 as per approved makes Membrane MOC - PVDF / PES Membrane Type :- Pressure Feed Mambrane 0.01-0.04 Micron rating type, Out to in process No. of UF Membrane - As Per Manufacturer Make UF Membrane - Norit / Pureflow / Koch / Dow / GE (b) Supply, installation,testing & commissining of 1 Set UF Feed Pumps. Capacity 21 M3/hr each (1 W + 1 SB) Head 20-25 Mts RPM 2900 (c)Supply, installation, testing & commissioning of 1 Set UF pre fine filtration. It can be micron filter or Bag filter as per vendor design. The MOC of housing of filter shall be PP (d)Supplying, installing, testing, commissioning of 1 Set centrifugal Vertical UF Backwash pumps with Complete SS - 304 with motor, pressure gauge with isolation cock, Isolation valve, NRV on delivery line. Isolation valve, strainer at suction. The pump shall be suitable for 415±10% volts 3 phase AC supply . Capacity : - 27 M³/h Head : - 18- 20 m No. of Pumps: 2Nos ( 1 Working + 1 Stand By ) (e)Supplying, Installation, testing and commissioning of 1 Set chlorine dosing system compromising of Sintex Tank with inlet/ outlet connection, piping and valves alongwith metering pump of 6 LPH for dosing. (f)Supply, Installation, testing and commissioning of 1 Set CEB / CIP dosing sstation including dosing tank, pumps complete in all respect as per UF memrbane specification requirement (g)Supply installation commissioning of 1 Set PLC control panel with all automation required like Pneumatic valves, piping in uPVC PLC and other required accessories. Make PLC - Delta, Pneumatic Valve / Solenoid Valves, uPVC Pipe. (h)Supply installation commissioning of 1 Job MS epoxy coated skid for the complete plant (j)Supply, installation & commissioning of 1 Set HDPE backwash tank of 1000 Litre capacity including required level controller inlet, outlet, overflow and drain connection. Ultra Filtration System as Descrbe Above
Water Body Fitration System (1)Supply, installation, testing & commissioning of 2 Nos. Totaly Non-Corrosive Filter made of Fibreglass and reinforced with Bobbin wound polyester yarn, Fitted with collector arms and diffusers made from unplasticised PVC and Polypropelene., Hub for holding the collector arms should be made of Stainless Steel, Filter Diameter 1800 mm. (The diameter should be minimum 1800mm as measured at any point of the Height On Straight). Flanged Connection for inlet & outlet : 160mm, Manhole lid: 390mm dia, Media Bed depth 1000mm, Working pressure 2.5kg/cm2, (37.5 PSI), Test pressure 3.75 kg/cm2 (56.25 PSI). Flow rate of 100 m³/hour at a specific velocity of 40m³/hr/m². Filter to be supplied complete with lid in polyester resin and fibre glass, of mini-mum 500mm dia, to ensure easy access to the filter internals,manual air purge cap, for sand discharge, presurre gauge. (2)Supply, installation, testing & commissioning of 2 Nos. Manually operated 5 Valve batteries built entirely in PVC/PN-10 with 160mm flanged connections to filters. Butterfly valves also in PVC. Supports & Clamps made of SS Pipes. (3)Supply, installation, testing & commissioning of 5600 Kg Silica sand media for filter with granulometry between 0.4 and 0.8mm. (4)Supply, installation, testing & commissioning of 2000 Kg Gravel for filter with granulometry between 1-2 mm. (5)Supply, installation, testing & commissioning of 3 Nos. Self Priming pump with injection moulded componement of high quality glass reinforced thermoplastic, Body is made of Polyproplene, Prefilter body in Polyproplene with Basket with lid Pre-filter is closed with knob system of easy acessibilty, Shaft : Made of AISI SS 316, Mechanical seal : made of graphie/Ceramic, Impeller : Made of plastic ,Capacity : 7.5 HP,Motor 2850 rpm, IP 55 , 50 Hz, IE 2 motor , Electrical Protection : IP55, Capable of delivering 100 m³/hr @ 12 m head and shut off head not exceeding 2.5kg/cm2, Duty 3 nos. 1 no. standby. (6)Supply, installation, testing & commissioning of 4 Nos. Chemical Dosing system for pH and Chlorine Electromagnetic dosing pump in Polypropylene, IP 65 protection. Maximum Flow 10.0 lph at 5 bar. 0-100% manual flow adjustment.180 strokes / minute. (7)Supply, installation, testing & commissioning of 2 Nos. Semi transparent polyurethane tank for feeding chemicals to the dosing pumps Dia. 580 mm x 900 mm Height 200lts capacity. (8)Supply, installation, testing & commissioning of 8 Nos. ABS Drain Grill 300 mm x 300 mm. (9)Supply, installation, testing & commissioning of 12 Nos. Suction inlet in white ABS with cap internal 50mm glue connection. (10)Supply, installation, testing & commissioning of 90 Nos. White ABS plastic bottom inlet for concrete with S.S. screws and regulable flow. Max flow 9 m3/hr. Connection: Outside/ inside dia 50mm Glue. (11)Supply, installation, testing & commissioning of 200 Metres White Color Modular Gratings made in UV stabilized PP. With Anti-spill design Snaps together on central spine thus enabling a flexible continuous run.45 units per meter, Ht.22 or 35 mm, width: 295 mm (12)Supply, installation, testing & commissioning of 400 Metres Grating Profile for Grating support on both side of overflow channel in PP height 25 mm (13)Supply, installation, testing & commissioning of 1 No. Anodised aluminum double vacuum head (900 mm width) with 1-1/2" connection with rope. (14)Supply, installation, testing & commissioning of 1 No. Extensible handles for cleaning attachments in anodized aluminium which can be adapted to the entire range of cleaning equipment, brushes, leaf skimmers and scoops. 10 mts. Long (15)Supply, installation, testing & commissioning of 1 No. Transparent blue Copolymer Floating vacuum hose 1.5" dia (40mm) 30 mtrs long. Including hose cuffs for connection to suction inlets. (16)Supply, installation, testing & commissioning of 1 No. Deep bag net made in polypropelene and white polyester netting clip type connection. (17)Supply, installation, testing & commissioning of 1 No. Surface net made in polypropelene and white polyester netting clip type connection. (18)Supply, installation, testing & commissioning of 1 No. Curved brushes made in polypropelene for pool basins and scum liners clip type connection. (19)Supply, installation, testing & commissioning of 1 No. Straight brushes with stainless steel bristles. (20)Supply, installation, testing & commissioning of 1 No. Reinforced aluminium telescopic handle 2.4 - 4.8M long with clip type connection. (21)Supply, installation, testing & commissioning of 1 No. Algae Brush with Aluminium back and S. S. bristles, fixing with clip connection. (22)Supply, installation, testing & commissioning of 2 Nos. Test kit for free chlorine & pH. (23)Supply, installation, testing & commissioning of 1 Lot uPVC Pipes & Valves 10 Kg/cm2 pressure rating , pipe diameter 50 mm to 200 mm, including all fittings. (24)Supply, installation, testing & commissioning of 1 Lot. Electrical Power & Control Cables, including all fittings. (25)Supply, installation, testing & commissioning of 1 No. Electrical Motor control panel as required for proper operation of system. (26)Supply, installation, testing & commissioning of 1 Lot uPVC Puddle Flanges. (27)Supply, installation, testing & commissioning of 50 Metres GI Earthing strip/Wire clampled to the wall, cable tray complete as required including interconnection between length at joints all fixing acessreis saddles, clamp etc 25 x 3 mm strip. (28)Supply, installation, testing & commissioning of 1 Lot Pipe support. (29)Supply, installation, testing & commissioning of 1 Lot Intial chemical charge for 1 month start up of water body based in 12 hours running (30)Supply, installation, testing & commissioning of 100 Nos. Hammer Drive Anchor Fastener 12 x 100 mm Steel Zinc Plated in nos. Water Body Filtration System as Describe above
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, 2 Way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. - 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. - 25mm dia
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Triple pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. -40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 A
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. For 8 way, Double door SPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 6 way, Double door TPN MCBDB
Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
Supplying and fixing following rating, 'C' series, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 40 amps
Supplying and fixing following rating, 'C' series, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. - 63 amps
Supplying and fixing following rating, 'C' series, Double pole, 240 volts, RCBO (30mA, 10KA) in the existing MCB DB complete with connections, testing and commissioning etc. as required. (SPN DB Incomer) - 40 amps
Supply, Installation, Testing and Commissioning of 20W COB LED downlight recess mounting luminaire with high performance LEDs with suitable wattage as per design, suitable for mounting with Armstrong/Grid ceiling, Aluminium powder coated white after phosphochromate treatment. LED module is mounted on FR4 with system lumen efficacy of >100lm/W to enhance the lumen output to ensure better uniformity.Powered by an SELV Output electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test. Lumen Output of 2000 lumens.CRI >80, Color temperature 5700K, THD <10% and PF >0.95,IP20,Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-60 HZ; Internal Surge Protection:3 KV.
Deep Recessed adjustable (UGR<19) LED Downlighter 15W. Fixture to be made of Albumin ADC12 housing in white color with mirror finished aluminium reflector mounting kit for light control 15°/24°/32°/50° Beam Angle and 38° shielding angle. LED Used shall be COB type with system Lumens 1410 lm ±10%, fixture Life of : 50k hours L80B50, CCT of 3000K (SDCM≤3), IP20, CRI >90 for high quality light output. power factor >0.90 an operating Voltage Range of 220 - 240 VAC with Operating temperature range - 20 C -+45C. Fixture should comply with EMC/ EMI with flicker free operations ripple <5%, BIS certification is required for LED Driver & Luminaire along with Class I classification The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Luminaire manufacture shall provide LM79 report from NABL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should have separate BIS approval.
Supply, Installation, Testing and Commissioning of IP 20 IK03 LED Downlighter 12W LED, system lumen ≥ 100 Lm/w having PC Housing Body, CRI >80, THD <10%, CCT 5700-6500K, Surge Protection >2.5KV. Life 50000 Hrs. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, Testing and Commissioning of IP 20 IK05 Surface Mounted Batten 20W LED, system lumen ≥ 100 Lm/w having Aluminium Extrussion Housing Body, CRI >80, THD <15%, CCT 5700-6500K, Surge Protection >2.5KV. Life 50000 Hrs. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of 10 Watt LED Bracket light and minium system efficacy of 100lm/w. The luminare should have color temperature of 6500K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. The luminaire has the features of Input voltage: AC220-240V, 50/60Hz Voltage HPF High Surge Protection : 3KV Long life of LEDs 50,000* BH (L70) Confirmed to IEC Safety Standard (IEC60598, IEC61347) integrated LED Driver offers comfortable softlight, high durability.
Supply, Installation, Testing and Commissioning of 10W LED Mirror light including connections etc as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supply, Installation, testing and Commissioning of 450mm dia exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supply, Installation, testing and Commissioning of Stylish, Robust & reliable in UP-Down light with aluminum housing offers uniform light distribution with IP 67 protection suitable for 15W LED gives nominal system lumen output of 800lm .The luminare should have beam angle of 24 Deg with a color temperature of 4000K and CRI>70. The luminaire shall meet IP67 rating HPF and The luminaire housing should made of pressure die-cast aluminium. The luminaire has the features of Input voltage: AC220-240V, 50/60Hz. High Surge Protection : 4KV Confirmed to IEC Safety Standard (IEC60598, IEC61347).
Supply, Installation, testing and Commissioning of Decorative 25 LED with 3.0 M pole aluminium housing offers uniform light distribution with IP65 Protection with 30 W LED will gives minimum system efficacy of 100lm/W.CCT 4000K and CRI>70. and The luminaire housing should made of pressure die-cast aluminium with glass diffuser and specially designed heat sink for better heat dissipation. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Decorative & cylindrical shape LED Bollard 8W LED nominal system lumen output of 400lm The luminare should have color temperature of 4000K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Decorative & cylindrical shape 8 W LED Gate light nominal system lumen output of 400lm The luminare should have color temperature of 4000K and CRI>70. The luminaire shall meet IP65 rating HPF and The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Robust and reliable LED Narrow beam uplighter with aluminum housing offers uniform light distribution, high durability and IP67 Protection 4W LED with system lumen output of 40lm with a color temperature of 4000K and CRI>70. The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of 35W LED Postop made up of aluminium pressure die-cast aluminum with integrated pole top with polyester powder coating in addition to a specific weathering resistance treatment, color RAL7011.Non-yellowing transparent and textured Polycarbonate UV-protected round symmetrical diffuser 1.5 mm thick with circular radial pattern for glare-free and even light distribution. The fixture should have provision of simplified extraordinary maintence by an easy to remove top openable driver compartment. High Efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen Efficacy of LED>105Lm/W@ 3000K color temperature and CRI >70. Powered by Built In electronic. LED driver with THD<10%, 4kV inbuilt surge protection, high cut off at 325V, auto-restart etc. Suitable for pole mounting having OD of 60 mm and height of 6 meters. Fixture Lumen>3700 Lm, IP 66(no glue), IK 10, PF>0.95, Operating voltage range: 120 V - 277 V Average life L70B50: 50000 hours. Luminaire manufacture shall provide LM79 report from NABL/UL accredited lab & LM80 report issued by LED manufacturer. Both the fixture and Driver should be of same make & must have separate BIS approval.
Supply, Installation, testing and Commissioning of Robust and reliable LED Step Light with aluminum housing offers uniform light distribution, high durability and IP65 Protection 4W LED with system lumen output of 40lm with a color temperature of 4000K and CRI>70. The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Robust and reliable LED Fountain Light with aluminum housing offers uniform light distribution, high durability and IP67 Protection 4W LED with system lumen output of 40lm with a color temperature of 4000K and CRI>70. The luminaire housing should made of pressure die-cast aluminium. LM79/80 shall be required from LED Manufacturer and from Third Party NABL LAB to authenticate the above parameters including connections etc as required.
Supply, Installation, testing and Commissioning of Street Light 35W LED will gives nominal system lumen output of 2500lm and minium system efficacy of 100lm/w. The luminare should have color temperature of 6500K and CRI>70. The luminaire shall meet IP66 rating HPF and The luminaire housing should made of pressure die-cast aluminium. The luminaire has the features of Input voltage: AC220-240V, 50/60Hz Voltage HPF High Surge Protection : 3KV Long life of LEDs 50,000* BH (L70) Confirmed to IEC Safety Standard (IEC60598, IEC61347) integrated LED Driver offers comfortable softlight, high durability.
Supply, installation, testing and commissioning of Hot dipped galvanised, octagonal, 8M height pole of structural design as per ILE TR7, considering the wind speed as per IS: 875. The material of construction should be BSEN: 10025 and galavansing as per BS: 729. The pole shall be having a minimum OAF of 130 mm at bottom and 70 mm at top.The pole shall have a minimum section thickness of 3 mm. The pole shall be fabricated in a single section. The pole shall be supplied with minimum 4 nos. 'J' type EN 8 grade foundation bolts of 16 mm dia x 450 mm length with a matching base plate of 200 mm x 200 mm x 12 mm thick. Pole shall be supplied with a inbuilt junction/looping box complete with flush door at the bottom with proper strengthening to the cutout of the door, suitable rating MCB, DIN rail, heavy duty connector , earthing terminals etc. Foundation of size not less than 400 mm x 400 mm x 600 mm deep shall be constructed in situ or precast in 1:2:4 RCC structure with embedded 3 nos. 63 mm OD DWC, HDPE pipes for cable entry, including excavation and refilling/ramming of soil, proper alignment of pole complete as per approved drawings by the Engineer-in-charge.
Design, fabrication, loading, unloading as directed by Engineer-in-Charge, supply of LT Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel 'T' irons and/ or flats wherever necessary, 16 gauge CRCA sheet steel shall be used for final distribution panels. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of zinc chromate primer and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and with 15% spare space, lifting hooks shall also be provided in case of large panels. Approval shall be taken for each panel before fabrication. Galvanized hardwares with zinc passivation shall be used in fabrication of panels. 1- ACB: LSIG (Microprocessor Based) releases shall be used for incoming feeders such as Transformers and DG Sets & LSI releases for outgoing breakers. 2- MCCB: MCCBs of above 250A Microprocessor Based and upto 250A thermal Magnetic releases. 3- Breaking capacity mentioned is Ics value. 4- This BOQ to be read in conjunction with technical specifications and Single Line Diagram (attached for reference). If any discrepancy occurs that should be brought to the notice of Client/Consultant before quoting the price otherwise stringent condition will be deemed to have been considered. 5- All MCCBs shall be provided with rotary operating handle and ON/OFF lamps backed by 2Amp control MCB. 6- All meters shall be digital type (unless otherwise specified) 7- Multi-function meter to be provided as required to cover all the parameters as mentioned. 8- All current/voltage transformer shall be cast resin type. 9- All indicating lamps shall be LED type. 10- Current density for bus bar shall not be more than 0.8A/Sqmm. Rating of Bus bar is after considering all derating factors. (Bus bar sizing calculation to be submitted for approval.) 11-All internal control wiring shall be heat resistant type. 12- All incoming breakers in Main LT panel shall be electrically interlocked. 13-Bus bar chamber shall be provided at top only. Incoming and outgoing cable entry shall be from top/bottom as required. 14- All feeders shall be provided with door interlocked with door defeat, pad lock facility. 15-Live parts shall not be accessible after opening the door, Transparent acrylic sheet to be provided to cover the same. 16- Spare contacts of ACBs/ MCCBs/ Relay/ Contactor shall be wired upto terminal block. 17-20% spare control terminal to be provided. 18- All MCCBs shall be provided with variable O/L & S/C releases. Incoming MCCB shall be provided with E/F releases also. 19- All incoming/outgoing cables shall be terminated on links/terminals. 20- 3-phase Digital Energy Meters with RS -485 Port (Dual Source) with necessary CTs. Main LT Panel : Main LT Panel shall Comprise of the following: a) Incomings: One (1) Nos. 800 Amps, 415 V, 35kA four pole draw out, Electrically operated ACB, with ON/OFF/TRIP circuit healthy/Spring Charged indication lamp and TNC control switch, under voltage & shunt trip release, anti pumping protection microprocessor based O/C, Time Delayed S/C, Instantaneous S/C, E/F protection etc. complete as required for Transformer Supply Feeder. One (1) Nos. 400 Amps, 415 V, 35KA, 4 pole drawout type electrically operated ACB with ON/OFF/TRIP/Trip Ckt. healthy/Spring Charged indication lamp, TNC control switch, under voltage & shunt trip release, anti pumping protection, microprocessor based O/C, Time Delayed S/C, Instantaneous S/C, E/F protection etc. complete as required for DG Supply Feeder. b) Metering & indication for Transformer Supply incoming breakers: Each Breaker shall be provided with : i) One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (Schneider EM6400NG or Equivalent make). ii) One (1) set 3 Nos. CTs of ratio 800/5A,15VA, Class 1.0 as required. iii) One (1) set of 800/5 A, C.L 1.0 CTs for input to APFC relay. iv) One set (3 Nos) phase indication lamp with backup SP MCB 2Amp. c) Protection Relays & Interlocking for transformer breaker: Each Transformer breaker to be provided with : i) One (1) no. REF (CAG14) or equivalent relay with stabilising resistance for transformer REF protection with 4 nos. 800/1A,CL-PS CTs of suitable VA and knee point voltage. ii) One (1) Set of Numerical, Multifuntional protection relay suitable for Under voltage (27), overvoltage (59), Trip Circuit supervision (95) and Master trip relay (86) protections. d)Metering & Indication For DG supply breakers: Each Breaker shall be provided with:- i) One(1) No. multifuction meter (MFM-1) with Rs- 485 port suitable for measurement of voltage, current, power factor, frequency,hour run, Power (kW,kVA, kVAR), Energy (kWH, KVAH, KVARH) and Harmonics (Schneider EM6400NG or Equivalent make). ii) One (1) set 3 Nos. CTs of ratio 400A,15VA, Class 1.0 as required. iii) One set (3 Nos) phase indication lamp with backup SP MCB 2Amp. e) BUS BARS: 1000Amp., 35kA, TPN, Aluminium Bus bar with colour coded, heat shrinkable sleeves. (with 100% neutral). Separate earth Bus of 65 x 8 mm Aluminium shall be provided. f) Outgoing: Each outgoing feeder shall be provided with ON/OFF/Trip indication lamps,shall be provide with Dual source Energy meter with RS 485 port with one set of suitable ratio, 15VA, class 1.0 CTs. The Number of outgoing feeders shall be as follows. No energy meters shall be provided in spare feeders. i) 1 Nos. 400 A, 25 KA, TP MCCB (for Capacitor Banks, without Energy Meter). ii) 3 Nos. 400 A,4P MCCB. iii) 2 Nos. 250 A,4P, MCCB. iv) 2 Nos. 160 A,4P, MCCB. v) 7 Nos. 100 A,4P, MCCB. Main LT Panel, described as above (from a to f).
Supply, Installation, Testing and commissioning of Cat6 23 AWG Solid Copper Conductor UTP LSZH Cable roll of 305 Mtr, in accordance to IEC 60332-2-33, ANSI/TIA 568 C.2, UL 444, IEC 60754 -1,2 & 3, IEC 60134-2 and ISO/IEC 11801–2nd Edition, 250 Mhz tested and UL & ETL Listed Cable, Grey, RoHS Certified for Connectivity of Hub room to End Point.
Supply, Installation, Testing & Commissioning of CAT6 UTP JACK, Universal (tool/toolless), As per ANSI/TIA 568 A/B wiring system, UL & ETL Verified- Blue for Camera at user end.
Supply, Installation, Testing & Commissioning of loaded 12-Port 1U loaded Universal Modular Straight Patch Panel, pre loaded with cable support Bar, Individual port transparent shutter and labelling point, Preloaded earthing plug for surge protection. UL & ETL Verified. CRC Metal with Black Powder Coated. RoHS Compliant, in accordance to ANSI/TIA-568-C.2, ISO/IEC 11801:2002/AMMD.2:2010, YD/T 926.3-2009, ISO/IEC 60603-7 standards. Saftey parameters as per UL 94V-0, at rack end.
Supply, Installation, Testing & Commissioning of loaded 24-Port 1U loaded Universal Modular Straight Patch Panel, pre loaded with cable support Bar, Individual port transparent shutter and labelling point, Preloaded earthing plug for surge protection. UL & ETL Verified. CRC Metal with Black Powder Coated. RoHS Compliant, in accordance to ANSI/TIA-568-C.2, ISO/IEC 11801:2002/AMMD.2:2010, YD/T 926.3-2009, ISO/IEC 60603-7 standards. Saftey parameters as per UL 94V-0, at rack end.
Supply, Installation, Testing & Commissioning of Cat6 UTP 24AWG, Stranded Flexible, LSZH Jacket, in accordance to ANSI/TIA 568C.2 Patch Cord, Complying to UL94-V-0 BLUE 1 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of Cat6 UTP 24AWG, Stranded Flexible, LSZH Jacket, in accordance to ANSI/TIA 568C.2 Patch Cord, Complying to UL94-V-0 BLUE 2 Mtr for rack side switch to jack panel connectivity.
Supply, Installation, Testing & Commissioning of 1/2/ 4 Port British Style Spring Shutter Face Plate with elegant 2 Piece design ABS-UL94-V2, 86x86x12.8 (mm). Straight white for I/O fixing at user side.
Supply, installation, testing and commissioning of IP Outdoor type Dome Camera, Resolution upto 5 MP, Quad stream with each stream support H.265 + compression simultaneously, fixed focal lens 3.6mm, 1/2.8" CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265+ ,H.265 ,H.264+ H.264, frame rate : Main stream upto 5MP@25fps, substream upto 2MP@25fps, third and fourth stream upto VGA@25fps. Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning), Cross counting, Pedestrian detection ,Inbuilt IR LED, IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S, G& T. UL, CE, FCC Certified.
Supply, installation, testing and commissioning of Bullet Camera, Resolution upto 5 MP, Quad stream with each stream support H.265+ compression simultaneously, fixed focal lens 3.6mm, 1/2.8" CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265+ ,H.265 ,H.264+ H.264 , frame rate : Main stream upto 5MP@25fps , substream upto 2MP@25fps , third and fourth stream upto VGA@25fps . Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning), Cross counting, Pedestrian detection ,Inbuilt IR LED, IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S, G& T . UL, CE, FCC Certified.
Supply, installation, testing & comissioning of 5MP IP PTZ camera shall be equipped with a 1/2.8 in. progressive CMOS 2 MP sensor to capture 4.5-135 mm, 30x optical zoom lens with 360° endless continuous rotation. IR LED upto 200m. -40°C to 70°C (-40°F to 158°F) working temperature. Cameras can be retrofitted on many existing DVR/NVR installations without requiring additional storage. up to 128 GB microSDHC (Class 10) card for local video storage. Events : Motion Detect; Video Tamper; Audio Detect; No SD card; SD card EVENT error; SD card capacity warning; Network disconnection; IP address conflict; Illegal access. Waterproof (IP67) and IK10 vandal resistant camera housing.
Supply, installation, testing and commissioning of 24 channel NVR, ONVIF compliant , recording bandwidth 640 Mbps, output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16ch in/ 4ch out , 1 X RJ45 ethernet , iOS smartphone support, 8 HDD support , each HDD slot support upto 8 TB HDD, RAID support , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. UL,CE,FCC certified.
Supply, installation, testing and commissioning of 8 channel NVR, ONVIF compliant , recording bandwidth 640 Mbps, output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16ch in/ 4ch out , 1 X RJ45 ethernet , iOS smartphone support, 8 HDD support , each HDD slot support upto 8 TB HDD, RAID support , 1x3.0 USB for backup /upgrade , 2x 2.0 USB for mouse .Edge analytics of poposed cameras must be integrated with NVR . Artificial Intelligence Support having face recognition with compatible deep learning supported cameras, AI-Face registered quantity upto 10,000 ,A.I maximum captured quantity 200,000. UL,CE,FCC certified.
Supply, Installation, Testing & Commissioning of 4TB Surviellance Hard Disk.
Supply, Installation, Testing and Commissioning of Full HD 32" LED Professional Display Panel.
Supply, Installation, Testing and Commissioning of Rack Mounted Industrial 12 port L2+ Managed switch having 24*10/100/1000Base-T POE ports, 4*100/1000Base-X uplink SFP ports, 1*RS232 Console port. Forwarding Rate @ 64 byte 38.69Mpps .Operation TEMP/ Humidity -40~+85°C.
Supply, Installation, Testing and Commissioning of Rack Mounted Industrial 12 port L3+ Managed Access switch having 24*10/100/1000Base-T POE ports, 4*100/1000Base-X uplink SFP ports, 1*RS232 Console port. Forwarding Rate @ 64 byte 38.69Mpps .Operation TEMP/ Humidity -40~+85°C.
Supply, Installation, Testing and Commissioning of Workstation PC: Intel(R) Core(TM) i7-3770 Processor (8M Cache, up to 3.90 GHz); RAM: 8GB (1x8GB) Non-ECC DDR3 1600MHz ; Keyboard: 12 function keys; Chassis: Tower/Workstation; DVD: 8X Slimline DVD+/-RW, Data Only; Dual Graphics Card; Network interface card: Integrated Intel(R) 82579LM Gigabit1 Ethernet LAN 10/100/1000; Hard disk: 250GB, 7200 RPM 3.5" SATA 6Gb/s Hard Drive; Operating system: Windows 7 Professional 64 Bit or latest.
Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following: a) Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. b) IGBT Rectifier Modules to achieve less than 2% Input Current distortion and greater than 0.98 PF at Input at all loads. c) Fully microprocessor based with diagnostics capability. d) Dual Input (Separate Input for rectifier and separate input for Bypass) e) Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per SLD. f) Design, manufacturing, testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V Cells) g) Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Battery to be included in UPS cost 1 x 30 KVA UPS.
Design, manufacturing, assembly, testing at works, supply, receiving at site, erection, testing and commissioning of true-online double conversion VFI Technology UPS, 1Ph/3Ph. AC input & 3Ph/1Ph AC output UPS system suitable for 415VAC, 50Hz supply, variation +/-1% , PF 0.8 as required as per specification and consisting of following: a) Input range should be 320V AC-460V AC, in case the voltage range does not meet the specified range, cost of servo stabilizer should be added. b) IGBT Rectifier Modules to achieve less than 2% Input Current distortion and greater than 0.98 PF at Input at all loads. c) Fully microprocessor based with diagnostics capability. d) Dual Input (Separate Input for rectifier and separate input for Bypass) e) Required quantity and details of UPS are as mentioned below. Location details and mode of operation of UPS shall be as per SLD. f) Design, manufacturing, testing at works, supply, erection, testing and commissioning of One sets of SMF VRLA battery with each UPS capacity as mentioned below, having back up time as mentioned below at full load, with interconnecting cables, cabinets and standard accessories as per specification and as required for the UPS system. (12V Cells) g) Battery shall be external type with rack and suitable for 15 minute backup on 100% load. Battery to be included in UPS cost 1 x 60 KVA UPS.
Supplying, installation, testing & commissioning of central graphical fire alarm management system to centrally monitor and operate the fire alarm system complete as required.
Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Below False Ceiling
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. Above Fasle Ceilling
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supply, Installation, Testing & Commissioning of Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved. Hooters Circuit.
Supply, Installation, Testing & Commissioning of Isolator Module for Isolating short/ dewired/ loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.
Supply, installing, testing and commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance UL & FM Approved.
Supply, installing, testing and commissioning of 2 way communication Fire Fighter's Telephone Jack.
Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required.
Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required.
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required.
Supply, Installation, Testing & Commissioning of 1X100W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. 100 Watts
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 300 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 240 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 185 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 150 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 120 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 95 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 70 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 3½ X 50 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Aluminium Conductor Cables: - 4 X 25 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 3½ X 35 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 16 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 10 sq. mm
Supply, loading, transportation unloading at site, storages at site, shifting from storage place to site of following sizes of XLPE insulated PVC sheathed, FRLS, Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications. Copper Conductor Cables: - 4 X 6 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 185 sq. mm and upto 400 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on cable tray as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 300 sq. mm (70 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 240 sq. mm (62mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm (57mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 150 sq. mm (50 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 120 sq. mm (45 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25 mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width x 50 mm depth x 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 450 mm width X 50 mm depth X 2.0 mm thickness
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. 2 Core x 2.5 Sq.mm Cable
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. 4 Core x 2.5 Sq.mm Cable
Supplying, laying, installation, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated and PVC sheathed copper conductor armoured stranded control cable conforming latest IS complete as required. 10 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 2 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 4 Core x 2.5 Sq.mm Cable
Supplying of all materials and making terminations of control cable terminations for control cables above item complete with single brass compression glands, copper lugs etc. as required. - 10 Core x 2.5 Sq.mm Cable
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. - 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. - 90 mm dia (OD-90 mm & ID-76 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. - 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. Conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. - 200 mm dia (OD-120 mm & ID-103 mm nominal)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: - 50 x 6 mm strip
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: - 25 x 3 mm strip
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. G.I. Earthing Strip/Wire: - 8 SWG wire
Supply, installation, testing and commissioning of following sizes of GI/ Copper strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment/ System earthing complete as required including inter connection between length at joints, all fixing accessories such as Earth bar, saddles, clamps, lugs etc and other fixing hardware material as required for proper installation. CU. Earthing Strip/Wire: - 25 x 6 mm strip
Design, manufacture, loading, unloading, supply, Supervision of Installation testing and commissioning on location as desired by project manager or as shown in layout plan of 500 KVA, oil filled 11 KV/433V, 3 phase, 50 Hz, delta/star connected with additional neutral of LT winding brought out to separate bushing terminal for earthing, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, ON LOAD Tap changer with +5% & -15% tappings in steps of 2.5%, diagram & rating plate, oil temperature indicator, winding temperature indicator and buccholtz relay with wiring upto marshalling box, lifting lugs, first filling of oil, and weather proof 11KV HT cable box, LT cable chamber minimum 8mm thick non magnetic gland plate etc. complete as per specification and as per IS : 1180 latest amendment upto date. (The transformer shall be subject to all test specified in specification and test certificates shall be produced). The Transformer shall comply to IS: 1180, Losses shall be as per Level-II. Core shall be of prime metal grade CRGO with boltless design. Provision for CTs for REF protection shall be provided (CTs shall be provided loose as free issue item by the LT Panel Manufactrure to be fixed by Transformer Manufacturer either at site or works as the case may be) Voltage Ratio : 11 / 0.433 KV Vector Group : Dyn11 Tap Range [ON Load] : +5% to -15% step of 2.5% (As per IS : 1180) Insulation Class : 'A' Temperature rise of OIL by thermometer method @ 50 deg C over ambient (Shall bear as per IS : 1180) Temperature rise in winding by resistance method @ 55 deg C over ambient (Shall bear as per IS : 1180) Impedance : 5.0 % Terminal arrangement (HV) : 3C x 300 Sqmm 11 KV Terminal arrangement (LV) : 3.5C x 300 Sqmm Al ,XLPE Cable 500 KVA Transformer as described above
Design, manufacturing, testing at works and Supply Installation testing and commissioning of Radiator Cooled DG sets of following capacity (rating in kVA) compact packaged silent type, with Outdoor type Acoustic Enclosure to reduce the noise level as per requirements of central pollution control board, (72 db from 3 mtrs.) 415Volts, 3 phase, 50 Hz AC alternator coupled to diesel engine with Electronic Governer Suitable for Auto Load Sharing and Auto Synchronizing System complete with all accessories, standard specifications tool kits, service manual, self starting device, fly wheel, coupling with guard, V velt, radiator, instrument panel (starting switch with key, Water Temperature indicator gauge, Lub OIl Pressure gauge, Lube oil temperature gauge, Battery Charging Ammeter, indicating lamp, hour counter etc.), hospital silencer, common bed plate, anti vibration isolation pads, extended cable termination box, grouting bolts, first charge of engine oil, gear oil, high speed diesel oil, 24 volt maintenance free chargeable battery set with Trickle/Boost Battery charger, interface card for BMS connectivity complete as required of rating 415 Volts, 3 phase, 50 Hz. AC alternator coupled to Diesel Engine complete with all accessories. 250 KVA DG Set
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 120 sq. mm and upto 400 sq. mm
Supply of following sizes of 11 KV cables conforming to the data given below: Guaranted Technical Particulars for 11 KV Cables Conductor : a) Core/Size : 3 b) Material : Aluminium c) Shape : Circular d) Type : Stranded e) Insulation : Material : XLPE f) Inner Seath: Material : PVC(ST1/ST2) Type : Extruded g) Armour: Material : GI Type : Flat h) Outher Sheath: Material : HR PVC Type : ST 2 FRLS : Not required. i) Drum Length : As per Site requirement 3 C x 300 Sq.mm XLPE HT cable (Earthed)
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 300sq. mm
Brilliance - 10W (Underwater Spot)
Zerox S - 8W (Inground Uplighter)
Side Light - 3W (Step Light)
LL130063 - 4W (Floor Washer)
R System - R1 - 273W (Projector)
Alicante - 54W (Inground Uplighter)
LL130052 - 20W (Inground Uplighter)
Path Grazer - 14W (Low Height Bollard)
Agathos - R1 - 24W (Post Top Luminaire)
3M high MS Pole (MS Pole)
Wolf Projector - 13W (Spike Light)
LL130065 - 5W (Inground Uplighter)
Wolf Projector - 13W (Spike Light)
VRF/VRV OUT DOOR UNITS: Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 20.0 HP HEAT PUMP
VRF/VRV OUT DOOR UNITS: Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 28.0 HP HEAT PUMP
VRF/VRV OUT DOOR UNITS: Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 38.0 HP HEAT PUMP
VRF/VRV OUT DOOR UNITS: Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. 64.0 HP HEAT PUMP
VRV/VRF INDOOR UNITS: Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower ,multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drainpan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%,50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiveing signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 8.0 TR Ductable unit
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.0 TR Cassette unit with drain pump
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.6 TR Cassette unit with drain pump
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.0 TR Cassette unit with drain pump
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%,50Hz ,single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27Degree C DB and 19 Degree C WB temperature. 1.0 TR Hi-Wall unit with drain pump
Supply, installation, testing and commissioning of following minimum capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%,50Hz ,single phase AC supply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27Degree C DB and 19 Degree C WB temperature 2.0 TR Hi-Wall unit with drain pump
DX AHU COMPATIBLE WITH VRV/VRF ODU Supply, Installation, Testing and commissioning of factory built Ceiling/floor mounted DX double skin type horizontal air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, and internal gasket between the skins to interrupt the thermal bridge of the panel. AHU shall be complete in all respect dampers etc. Blower section with AMCA certified DIDW fan for ceiling suspended unit with highly efficient IE3 TEFC Squirrel cage motor drive suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply and variable frequency drive (VFD) as required. Cooling coil section with Dx cooling coil with aluminium finned copper tubes (Thickness not less than 0.4mm) & puf insulated 18G stanless steel drain pan with drain connections and AHU kit (priced separately). Filter section with 50mm thick metal viscus/washable synthetic type air prefilters having efficiency 90% down to 10 micron. Necessary vibration isolation arrangement, canvas connection etc., complete as per specifications and drawing of followings capacities. AHU: 8700 CFM (23.5 TR) 4 Row Deep Coil at 50 mm static pressure.
DX AHU COMPATIBLE WITH VRV/VRF ODU Supply, Installation, Testing and commissioning of factory built Ceiling/floor mounted DX double skin type horizontal air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, and internal gasket between the skins to interrupt the thermal bridge of the panel. AHU shall be complete in all respect dampers etc. Blower section with AMCA certified DIDW fan for ceiling suspended unit with highly efficient IE3 TEFC Squirrel cage motor drive suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply and variable frequency drive (VFD) as required. Cooling coil section with Dx cooling coil with aluminium finned copper tubes (Thickness not less than 0.4mm) & puf insulated 18G stanless steel drain pan with drain connections and AHU kit (priced separately). Filter section with 50mm thick metal viscus/washable synthetic type air prefilters having efficiency 90% down to 10 micron. Necessary vibration isolation arrangement, canvas connection etc., complete as per specifications and drawing of followings capacities. AHU: 9200 CFM (31.5TR) 4 Row Deep Coil at 50 mm static pressure.
DX AHU COMPATIBLE WITH VRV/VRF ODU Supply, Installation, Testing and commissioning of factory built Ceiling/floor mounted DX double skin type horizontal air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, and internal gasket between the skins to interrupt the thermal bridge of the panel. AHU shall be complete in all respect dampers etc. Blower section with AMCA certified DIDW fan for ceiling suspended unit with highly efficient IE3 TEFC Squirrel cage motor drive suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply and variable frequency drive (VFD) as required. Cooling coil section with Dx cooling coil with aluminium finned copper tubes (Thickness not less than 0.4mm) & puf insulated 18G stanless steel drain pan with drain connections and AHU kit (priced separately). Filter section with 50mm thick metal viscus/washable synthetic type air prefilters having efficiency 90% down to 10 micron. Necessary vibration isolation arrangement, canvas connection etc., complete as per specifications and drawing of followings capacities. AHU: 14500 CFM (52.5TR) 4 Row Deep Coil at 50 mm static pressure.
DX AHU COMPATIBLE WITH VRV/VRF ODU Supply, Installation, Testing and commissioning of factory built Ceiling/floor mounted DX double skin type horizontal air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation factory injected between them by injection moulding machine, and internal gasket between the skins to interrupt the thermal bridge of the panel. AHU shall be complete in all respect dampers etc. Blower section with AMCA certified DIDW fan for ceiling suspended unit with highly efficient IE3 TEFC Squirrel cage motor drive suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply and variable frequency drive (VFD) as required. Cooling coil section with Dx cooling coil with aluminium finned copper tubes (Thickness not less than 0.4mm) & puf insulated 18G stanless steel drain pan with drain connections and AHU kit (priced separately). Filter section with 50mm thick metal viscus/washable synthetic type air prefilters having efficiency 90% down to 10 micron. Necessary vibration isolation arrangement, canvas connection etc., complete as per specifications and drawing of followings capacities. AHU: 15000 CFM (53.5 TR) 4 Row Deep Coil at 50 mm static pressure.
AIR HANDLING UNIT KIT: Supply, installing, testing and commissioning of Electronic expansion valve & control kit compatible to connect the following Dx type AHU with the VRF outdoor unit, the AHU kit should be complete with Control box for flow of refrigerant so as to modulate the capacity of AHU as and when required in sync with VRF outdoor unit, the AHU kit should have corded remote control, and capability to control the AHU fan , speed of AHU Fan. Suitable for AHU :8700-9200cfm AHU 7.5HP)
AIR HANDLING UNIT KIT: Supply, installing, testing and commissioning of Electronic expansion valve & control kit compatible to connect the following Dx type AHU with the VRF outdoor unit, the AHU kit should be complete with Control box for flow of refrigerant so as to modulate the capacity of AHU as and when required in sync with VRF outdoor unit, the AHU kit should have corded remote control, and capability to control the AHU fan , speed of AHU Fan. Suitable for AHU :14500-15000cfm AHU 10HP)
Supply, installing, testing and commissioning of VFD starter suitable for following AHU unit complete as per specification and drawing. Suitable for AHU :8700-9200cfm AHU 5.5kw)
Supply, installing, testing and commissioning of VFD starter suitable for following AHU unit complete as per specification and drawing. Suitable for AHU :14500-15000cfm AHU 7.5kw)
Y-JOINTS: Supply Installation, testing, commissioning of supply & return Y-joints sets of required size for refrigerant piping as per manufacturer standards. Y- Joints set
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 6.4 mm OD 13mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 9.5 mm OD 13mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 12.7 mm OD 13mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 15.9 mm OD 13mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 19.1 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately).Dia 22.2 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 25.2 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 28.6 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 31.8 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 34.9 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 38.1 mm OD 19mm thick insulation
REFRIGERANT PIPING: Supply Installation, testing, commissioning and Interconnecting refrigerant copper pipe work (between indoor & outdoor units as per specifications) with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation. All piping inside the room shall be properly supported with MS slotted angle, including cutting chases, holes in walls/slabs and making them good. All external piping shall run in covered cable tray (item for cable tray shall be quote seperately). Dia 41.3 mm OD 19mm thick insulation
DRAIN PIPING : Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. 25 mm dia
DRAIN PIPING : Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. 32 mm dia
DRAIN PIPING : Providing and fixing of PVC drain pipe of 6 Kg /cm2 pressure rating complete with 6mm thick closed cell nitrile rubber insulation, fittings, supports, valves as per specifications & drawings. 40 mm dia
Air Cooled Inverter type Split AC SITC of inverter type Split Cooling units as per specifications and complete as required. Outdoor units shall be with rotary/scroll compressor air-cooled condenser coil with fan, casing, MS-stand, cabling and earthing as required. Indoor units shall consist of centrifugal fan with motor, dx-cooling coil of copper tubes and aluminium fins, casing, filter, full charge of gas and oil, control wiring, interconnecting refrigerant piping between indoor and outdoor unit, cooling thermostate control wiring, Note : Aluminium Fins and copper tubes of Air Cooled Condenser along with copper tubing / piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. 1.5 TR Hi-wall Unit
Air Cooled Inverter type Split AC SITC of inverter type Split Cooling units as per specifications and complete as required. Outdoor units shall be with rotary/scroll compressor air-cooled condenser coil with fan, casing, MS-stand, cabling and earthing as required. Indoor units shall consist of centrifugal fan with motor, dx-cooling coil of copper tubes and aluminium fins, casing, filter, full charge of gas and oil, control wiring, interconnecting refrigerant piping between indoor and outdoor unit, cooling thermostate control wiring, Note : Aluminium Fins and copper tubes of Air Cooled Condenser along with copper tubing / piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. 2.0 TR Hi-wall Unit
Sheet Metal Duct: Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet (22 G)
Sheet Metal Duct: Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet (20 G)
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.00 mm sheet (20 G)
Supplying, fixing. testing commissioningof GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, in accordance with approved shop drawings and specifications complete as required.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supply and fixing of Acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class "O") insulation on existing duct after applying two coats of cold setting adhesive (CPR X compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications etc complete as required. Fire Damper
Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications etc complete as required. Actuator
Supply, installation and balancing of extruded aluminium powder coated air louvers complete with aluminium wire mesh bird screen as per specifications.
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. 200 mm dia.
Supply, installation, testing & commissioning of aluminium iball jet nozzle diffuser of following sizes as per site requirement etc. complete as required as per specifications. 300 mm dia.
AXIALS FANS SITC of AMCA certified for sound and air performance (FEG) Tube Axial fan complete with tube casing in MS standard construction powder coated, aluminium impeller with adjustable blade angles,vibration isolator and directly coupled TEFC to Sq.cage induction motor, suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. The complete fan assembly shall be BSEN-1210-3-2002/UL listed for 250 Deg C 2 hours in accordence with power ventilator for smoke control systems and as per specification complete as required. Air Qty. = 12000 CFM Static Pressure = 20mm Wg Fan Speed = Not exceeding 1450 rpm
AXIALS FANS SITC of AMCA certified for sound and air performance (FEG) Tube Axial fan complete with tube casing in MS standard construction powder coated, aluminium impeller with adjustable blade angles,vibration isolator and directly coupled TEFC to Sq.cage induction motor, suitable for 415V±10%, 50 Hz. 3 phase electric supply complete with required hardware etc. The complete fan assembly shall be BSEN-1210-3-2002/UL listed for 250 Deg C 2 hours in accordence with power ventilator for smoke control systems and as per specification complete as required. Air Qty. = 16000 CFM Static Pressure = 20mm Wg Fan Speed = Not exceeding 1450 rpm
INLINE FANS Supply, Installation, Testing and commissioning of Fresh/exhaust air fan suitable for Inline mounting comprising of forward curved centrifugal blower complete with induction motor, metal clad MCB, canvas connection all compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz AC. supply as per specifications of following capacities: Noiselevel should not exceed 65dB(A)at 3 meter in room condition. 500 cfm capacity with10 mm static pressure
INLINE FANS Supply, Installation, Testing and commissioning of Fresh/exhaust air fan suitable for Inline mounting comprising of forward curved centrifugal blower complete with induction motor, metal clad MCB, canvas connection all compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz AC. supply as per specifications of following capacities: Noiselevel should not exceed 65dB(A)at 3 meter in room condition. 600 cfm capacity with10 mm static pressure
INLINE FANS Supply, Installation, Testing and commissioning of Fresh/exhaust air fan suitable for Inline mounting comprising of forward curved centrifugal blower complete with induction motor, metal clad MCB, canvas connection all compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz AC. supply as per specifications of following capacities: Noiselevel should not exceed 65dB(A)at 3 meter in room condition. 700 cfm capacity with10 mm static pressure
INLINE FANS Supply, Installation, Testing and commissioning of Fresh/exhaust air fan suitable for Inline mounting comprising of forward curved centrifugal blower complete with induction motor, metal clad MCB, canvas connection all compete as required. Motor shall be suitable for single phase, 230 volts, 50Hz AC. supply as per specifications of following capacities: Noiselevel should not exceed 65dB(A)at 3 meter in room condition. 800 cfm capacity with10 mm static pressure
PROPELLER FANS Supply, Installation, Testing and commissioning of wall mounted propeller type exhaust fans of Axial Flow type with light weight type PVC / aluminium impellers with aerofoil contours for high efficiency and low noise. The fan shall be supplied complete with and gravity louvers with a suitable Squirrel cage induction motor. 225 mm dia
AIRWASHER Supplying, Installing, Testing and Commissioning of CELDEK FILL package type air cooling unit with minimum 90% saturation efficiency. Air cooling unit shall be factory assembled and complete with double skin casing 0.8mm Inner / outer pre-coated GI sheets, DIDW forward curved fans with TEFC, sq. cage, induction motors 1440 RPM (IE-3) with IP-55 Protection. Suitable for operation on 415 ± 10% voltage, 50 Hz 3 phase AC supply, drive package including multi sheave pulleys and belts for fans and motors, 1.2mm thick tank & pad section in SS Construction, vibration isolators, wire mesh pre-filters, 200 mm thick CELDEK FILL, Water Circulation Pump (1W+1S), internal PVC piping, valves and fittings, 4-bend PVC eliminator. The Unit shall be following capacities complete as required. 5500 cfm WITH capacity with 40 mm static pressure for kitchen
DRY SCRUBBER Supply, Installation, Testing and Commissioning of dry type scrubber comprising of electrostatic section with auto wash multiple cells to suit total volume. The housing shall be 16 gauge zinc coated steel sheet with gasketed access door, electrical interlocked, and bottom drain pan integral washing system. The unit can be floor mounted or ceiling suspended. The cell wash module shall have a set of metal mesh filters. The electronic air cleaner shall be the two- stage dual voltage plate type cells and efficiency of 90% as per ASHRAE test Standard for dry particulate. Ionizing-collecting cell shall be of one-piece construction. Power supply shall be 100% solid state. UL listed on 200 to 240 VAC, 50HZ, single Phase input with an LED light indicating the performance status. The controller shall be programmable logic controller (PLC) with terminals to interconnect the system fan and sequence the detergent wash, soak, rinse fan return to operation cycle. The wash system shall be with manifolds located on the air entering side of the perfilter ionizing / collector cell through spray nozzles. The detergent pump shall be of positive displacement self priming type. 6500 cfm capacity for kitchen
SISW KITCHEN EXHAUST FAN FOR SCRUBBER Supply, installation, testing and commissioning of Suitable SISW Backward Curved Kitchen Exhaust Air Fan in double skin construction complete with TEFC Induction Motor, Drive Assembly, Base Frame, Vibration Isolators and other accessories etc as per specification complete as required. 6500 cfm capacity for kitchen
AIR DISTRIBUTION WORK FOR VENTILATION SYSTEM Sheet Metal Duct: Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24 G)
AIR DISTRIBUTION WORK FOR VENTILATION SYSTEM Sheet Metal Duct: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24 G)
AIR DISTRIBUTION WORK FOR VENTILATION SYSTEM Sheet Metal Duct: Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.80 mm sheet (22 G)
AIR DISTRIBUTION WORK FOR VENTILATION SYSTEM Sheet Metal Duct: Supply, installation, balancing and commissioning of MS WELDED rectangular/round ducting complete with all fixing seal,fire paint, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.6mm sheet (16G)
Supply, fabrication, installation and testing the non-porous flexible connections constructed of fire resistance flexible, double canvas connection with resistoflex material as per the approved shop drawings.
Supplying, installing and testing of extruded aluminium louvers with bird screen in accordance with approved shop drawings and specifications complete as required.
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed Aluminium conductor armoured cables including , clamped includes anchor fastners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning etc as per specification complete as required. 3C x 6 Sq.mm.
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed Aluminium conductor armoured cables including , clamped includes anchor fastners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning etc as per specification complete as required. 3C x 10 Sq.mm.
Supplying & laying of following 1100 volt grade XLPE insulated PVC sheathed Aluminium conductor armoured cables including , clamped includes anchor fastners wall with suitable clamps, saddles fixing bolts including connecting testing and commissioning etc as per specification complete as required. 3C x 16 Sq.mm.
Supply and erection of hot dip G.I. cable tray perforation not more than 17.5% for specific dimensions along with tees, bends. The cable tray shall be hang from ceiling/ fixed to wall with necessary angle/flat iron / hanging rod, for ceiling suspensions, clamps, anchor fastner, nuts, bolts, washers, not mor than 1.5 mtr. apart complete as per specification to complete the job. The tray shall be as follows :- 100 x 50 mm x 1.6mm thick
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia. ISI marked, PVC conduit
WIRING IN EXISTING CONDUIT / PVC CASING CAPPING WITH COPPER CONDUCTOR Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2x 1.5Sq mm
WIRING IN EXISTING CONDUIT / PVC CASING CAPPING WITH COPPER CONDUCTOR Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 4x 2.5sq.mm
EARTHING SYSTEM Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing aling with existing surface/recessed conduit/submain wiring/cable as required. 6SWG
DESIGN, FABRICATION, INSTALLATION, TESTING & COMMISSIONING and 5 years Operation and Maintenance of multimedia and interactive exhibits for the museum at Alaboi Memoral Park in the proposed museum buildings spread over an area of 7000 sq mtr including equipment, soft content (audio, and video, and animation), graphics and signage, required civil and interior and acoustic and works. The major installations proposed include the following 1. Key Introductory exhibit with holographic projection and customised audio 2. Dome projection theatre for 100 persons, 3. 5 nos Individual audio-video kiosks featuring audio visual exhibit with multiple projections and audio tracks.
SHREE GAUTAM CONSTRUCTION CO. LTD.
M/s Sanwarmal Khetawat
Ahluwalia Contracts India Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid