GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR MAINT OF FLAME PROOF WIRING INCLUDING REPAIR MAINT REPLACEMENT OF LIGHT FITTINGS AND FIXTURES AND CONNECTED ITEMS IN TECH AREA AT AFS CHAKERI KANPUR
2020_MES_343938_1
8405/E8
Open Tender
Civil Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹82,000
17 Jun 2020
11 May 2020
15 Jun 2020
11 May 2020
8 Jun 2020
25 May 2020
Amount
Taking down unserviceable MS conduit point wiring from existing place ( light fan, socket or power points) complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants holders etc and making good to disturbed surface to wall, floor etc to match with existing surface either by using same colour distemper, puuti or white / colour wash all as required complete all as specified and directed.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories complete all as specified and directed.
M & L for flameproof concealed point wiring on wall and surface wiring on ceiling / roof /hanger with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled ERW rigid steel conduit (metallic) not less than 19 mm dia with all MS conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces for one light, fan point controlled by one switch complete all as specified and directed. Note : Junction boxes sahll be measured separately
S&F in repair Flame proof - weather proof switch socket & plug combined 25 A, 500 V(3P+Earth) with cable termination in LM 6 aluminium alloy housing including taking down old unserviceable complete all as specified and directed.
S&F in repair flame proof weather proof threaded type junction box LM 6 aluminium alloy 2 way complete including taking down old unserviceable complete all as specified and directed.
All as per item No 5 here-in-before but 3 way
All as per item No 5 here-in-before but 4 way
S&F in repair flame proof weather proof metallic hose conduit 3/4 " dia 300mm long including taking down old unserviceable complete all as specified and directed.
All as per item No 8 here-in-before but 500mm long -do-
S&F in repair flameproof double compression brass cable gland 3/4" dia complete with nipples including taking down old unserviceable complete all as specified and directed.
S&F in repair flameproof weather proof main switch 32A TPN complete with fixing arrangement including taking down old unserviceable complete all as specified and directed.
S&F in repair Flame proof weather proof switch with cable termination in LM 6 aluminium alloy housing 16 Amp, 240 volts complete including taking down old unserviceable complete all as specified and directed. Note for Srl item No 4 to 12:- Make : Bajaj/Sudhir/CG/Shyam switch gear Pvt Ltd.
S&F in repair double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with IP 54 Protection with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed. Make : Legrand/L&T/C&S
All as per item No 13 here-in-before but 4 way.
All as per item No 13 here-in-before but TPNL 4way, 415 volts -do-
S&F in repair sheet metal enclosure double door type for DB when MCBs & MCCB 100 (as incomer) to be used, TPNL, 4 ways, 415 V, IP 54 Protection with bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S &F in repair testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
All as per item No 17 here-in-before but SP 40-63 Amps -do-
All as per item No 17 here-in-before but SPN 16-32 Amps -do-
All as per item No 17 here-in-before but SPN 40-63 Amps -do-
All as per item No 17 here-in-before but TP 40-63 Amps -do-
All as per item No 17 here-in-before but TPN 40-63 Amps -do-
S&F in repair MCCB 125 Amps, 4 Pole, 415V, 25KA Note for Srl item No 13 to 23:- MCBs & DBs shall be used of same make only
S&F in repair Flame proof weather proof LED luminaire 2 X16/20W, epoxy finish with LM 6 aluminium housing , heat resistant borosilicate tubular glass held in two alluminium cups with inbuilt DRIVER accessories & LED tubelight including taking down old unserviceable complete all as specified and directed. Make: CROMPTON cat pt no EXTN1LT8-16/20
S&F in repair non integral flood light fitting 1x250 watt MH Flame proof - weather proof luminaire with LM 6 aluminium alloy lamp housing , heat resistant and toughned glass, hings cover with neroprene gasket, painted MS bar guard, epoxy finish provided with external flameproof control gear & fixing accesories with suitable MH lamp including taking down old unserviceable complete all as specified and directed.. Make bajaj Cat: Part BJFFL 250/400NI / sudhir-FL/1251
S&F in repair LED flood light fitting 40 watt LED Flame proof - weather proof well glass luminaire with LM 6 aluminium alloy lamp housing , heat resistant and tuffend glass, hings cover with neroprene gasket, painted MS bar guard, epoxy finish provided with internal flameproof control gear & fixing accesories with suitable driver including taking down old unserviceable complete all as specified and directed. Make: Crompton Cat No. fwl1315-40-CDL/CG or sudhir-catpart No-0151
S&F in repair control gear box (flame proof) epoxty finish LM6 aluminium alloy housing with accessories and three cable entries suitable fcr HPMV light fitting 1x250 watt including taking down old unserviceable complete all as specified and directed. Make-sudhir--CGB/A/13-bajaj BJFC-125MV CA
S &F in repair flamefroof well glass fitting 125 W HPMV lamp with complete control gear assembly for fitting at any location & at any height complete all as specified and directed. Make - sudhir/shyam or equivalent
S&F in repair integral 1x15 watt LED flameproof weather proof bulkhead lumainaire with hear resistant toughend flat glass cover, LM 6 aluminium housing complete with flameproof control driver including taking down old unserviceable complete all as specified and directed.. Make: Crompton Cat No. FWL 1315 -40-CDL/CG or sudhir-0197
S&F in repair LED aviation obstruction light fitting, red painted die-cast aluminium alloy housing , red coloured polycarbonate dome and accessores suitable for LED 300 -TWIN complete all as specified and directed Make :BAJAJ -cat part No BGAV 302 or shyam/sudhir/CG
S&F in repair LED aviation obstruction light fitting, red painted die-cast aluminium alloy housing , red coloured polycarbonate dome and accessores complete comprising of LED 300 SINGLE complete all as specified and directed. Make : Bajaj/shyam/shudhir/CG
S&F in repair LED Flame proof batten 1x16/20 Watt suitable for safe working in gas/vapour envirment with IP65 protection linked alongwith driver and all other accessories for installation complete all as specified and directed. Make - sudhir/Shyam/CG or equivalent
M&L sub main wiring with two single core PVC-FR insulated unsheathed stranded copper conductor cable of size 4 sqmm drawn in conduit with 2.5 Sqmm PVC-FR insulated unsheathed stranded copper conductor as a continuous earth wire including taking down old unserviceable sub main wiring complete all as specified and directed. Note : (i) Two single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii)Conduit pipe and fitting will be measured and paid separately
All as per item No 33 here-in-before but with 6 Sqmm ,4single core PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 4 Sqmm PVC insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead -do- Note : (i) Four single core cable and one run of earth copper conductor will be measured and paid as one unit length (ii)Conduit pipe and fitting will be measured and paid separately
S&F PVC insulated, 6 sqmm alluminium stranded conductor sheathed, twin core flat cable in & incl PVC conduit medium grade 20mm dia complete burried in ground (300 mm below GL) incl earth work & connection to exixting system complete all as specified and directed. Note :Conduit pipe and fitting will be measured and paid separately as applicable
S&F in repair rigid stove enameled steel conduit ISI marked of size not less than 20 mm dia position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly on as in concealed position incl cutting chasing & making good to disturbed surfaces & matching with the existing colour of wall/floor etc including taking down old rusted MS conduit complete all as specified and directed.
All as per item No 36 here-in-before but 32mm dia stove enameled steel conduit ISI marked incl taking down old rusted MS conduit -do-
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 8 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed..
Disconnecting & Taking down FLP ceiling fan,,Axial flow fan any type any size any sweep any make from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of ceiling fan and providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete & rehanging fan to site incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers etc whereas required and refixing in position complete all as specified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire , winding & painting will be measured & paid separately under S&F /M&L items here-in-after
S&F in Replacement of ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable complete all as specified and directed.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled grey paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan/ all sweep complete all as specified and directed.
Supply and fix condenser with PVC clamp of 2.5 mfd complete all as specified and directed.
Supply and fix condenser with PVC clamp of 4 mfd complete all as specified and directed.
Supply and fix condenser with PVC clamp of 6 mfd complete all as specified and directed.
M&L for removing of burnt winding from FLP ceiling fan stator of size 1200mm/1000mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete all as specified and directed.
Disconnecting & Taking down FLP Exhaust fan any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling, commissioning and testing complete & refixing fan to site incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers whereas required and refixing in position complete all as specified and directed. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
Material and Labour for removing of burnt winding from exhaust fan450/600 MM fans rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete including transportation to work shop and bringing back to store and testing complete all as specified and directed.
Material and Labour for making circular holes suitable for fixing of 18”/24" sweep Exhaust fans by cutting the wall any thickness/ required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site complete all as specified and directed.
S&F in repair exhaust fan MS blade 12” to 15” as per existing complete all as specified and directed.
S&F in repair exhaust fan MS blade 18” to 24” as per existing complete all as specified and directed.
M&L for MS front frame suitable for mounting of stays of suitable for 18" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing complete all as specified and directed.
All as item No 51 but suitable for 24" exhaust fan -do-
M&L for circular / rectangular framed shutters suitable for FLP 18" exhaust fan made out of as per existing size and strength for shutter painted with two coat of synthetic enamelled over a coat of red oxide primer complete with neccesarry fixing accessories all as per existing complete all as specified and directed.
All as item No 53 but suitable for 24" exhaust fan -do-
Taking down flameproof HPSV / HPMV /HPMH/LED fittings,/ Flameproof tube light fittings/ bulkhead flameprrof fittings any location any capacity from any height any situation, repairs to the extent by removing connections from the system checking of unserviceable spare parts and serviceable parts ,replacement of unserviceable parts with new spares and testing complete, tightening the loose connection and made item functional, reassembling the fitting and re-fixing/ re-hanging the same after repair in existing location or other location (as directed) including replacement of three core proof copper cable of size 1 Sqmm and painting of MS Bracket and clamps with painting after cleaning with grey colour and tesing complete all as specified and directed. Note : Spares required for repair (except connection cable) shall be measured and paid separately as supply only items here-in-after and the cost of connection cable shall be deemed to be included in the quoted rates.
Supply only Copper ballast Metal Halide/HPSV 250 Watt complete all as specified and directed. Make: Philips/Wipro/Havells
Supply only Copper ballast Metal Halide/HPSV 400 Watt complete all as specified and directed. Make: Philips/Wipro/Havells
Supply only Copper ballast HPMV 400 Watt complete all as specified and directed. Make: Philips/Wipro/Havells
Supply only Copper ballast HPMV 250 Watt complete all as specified and directed. Make: Philips/Wipro/Havells
Supply only Lamp Metal Halide 250 Watt complete all as specified and directed. Make-Philips/Wipro/Havells
Supply only Lamp Metal Halide 400 Watt complete all as specified and directed. Make-Philips/Wipro/Havells
Supply only Lamp HPMV 400W complete all as specified and directed. Make-Philips/Wipro/Havells
Supply only Lamp HPMV 250W complete all as specified and directed. Make-Philips/Wipro/Havells
Supply only Copper ballast HPMV 125 Watt complete all as specified and directed. Make-Philips/Wipro/Havells
Supply only Lamp HPMV 125W complete all as specified and directed. Make-Philips/Wipro/Havells
Supplyonly Porcelain holder suitable for 125/150/250/400 watt HPSV/ HPMV lamp complete all as specified and directed. .
M & L in repaire for LED Building Security Light 110 watt of alumenium PDC housing glass coverwith IP 66 protection complete all as specified and directed. Make: Philips cat No BRP 410 LED 110 CW HE MR FG S2 PSU Gror equivalent in Havells/C&S
S&F in repair 60 watt LED flameproof wall glass in die cost alluminium with heat resistant to tonhened glass IP 65 protection for safe working in Gas/Vapour envirment CIMFR certificate desirable) alongwith driver and all other accessories complete all as specified and directed. Make: - Crompton FWL 135-60-CDL or equivalent in shayam/sudhir
M & L in repaire LED 100 Watt Flame proof light fitting Flood light suitable for industrial area complete wire with all accessories complete all as specified and directed. Make- sudhir/shyam/or equivalent
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and n.exc 1.5 mtr in depth for laying of under ground electric cable and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removing excavated surplus materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading ganga sand dry, clean in trenches as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as specified and directed. Note:- Punned thickness shall be measured and paid only .
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified and directed.
Supply and laying or fixing or passing through pipe, commissioning and testing LT XLPE cable 1100 volts insulated , screened , PVC bedded galvanised steel strip or wire armoured heavy duty Power cable with aluminum conductor of cross sectional area 25 sqmm 3.5 core using stranded conductor complete all as specified and directed. Make - Havells/POLYCAB/GRANDLY
Ditto all as per item No. 75 above but size 16 sqmm 4 core
Ditto all as per item no. 75 above but size 10 sqmm 2 core
VEE KAY ENTERPRISES
ashokcontractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .