Tender Value
₹1.7 Cr
EMD Value
₹3.4 L
Closing Date
20 Jan 2021, 4:00 pmClosed
OFICE OF THE SUPERINTENDING ENGG. OnM CIRCLE KTWR.
OFICE OF THE SUPERINTENDING ENGG. OnM CIRCLE KTWR.
SUPPLY, INSTALLATION, TESTING AND COMMISSIONING 05 Kms of new 33 KV line for realignment of existing 33 KV Khellani-Bhadarwah line and Stabilization of 33 KV Khellani-Bhadarwah line in district Doda by way of replacement of damaged poles, conductor
2020_PDD_111243_1
SE/OnM/JPDCL/CK/Capex 2020- 21/1 of 2020
Open Tender
Electrical Works
Turn-key
180 days
DODA
KINDLY REFER TO TENDER DOCUMENTS
2 documents required · 2 mandatory
₹4,000
THE SUPERINTENDING ENGG. OnM CIRCLE KTWR.
₹3.4 L
8 Mar 2021
11 Dec 2020
22 Jan 2021
12 Dec 2020
20 Jan 2021
12 Dec 2020
11 Dec 2020 - 12 Dec 2020
BOQ 1 - SUPPLY PART Stablization of 33kV line from Khellani to Bhaderwah twin Transmission line
Providing of 11Mtr Long S.T poles(410SP-56) complete with base plate and cap as per REC standards and specification.
Providing of 0.1 ACSR(DOG) Conductor
Providing of 33kV Polymeric Composite Pin Insulator 36KV, 10KN, Lightning Impulse 170KN Positive & 180 kV Negative, Creepage distance 900mm
Providing of 33kV Polymeric Composite Disc Insulator 36KV, Min falling load 70KN, Lightning Impulse 170KN Positive & 180 kV Negative, Creepage distance 900mm suitable for 0.1 ACSR Conductor
Providing of PG Clamps for 100mm sq ACSR cond
Galvinized Nuts & Bolts with Washer
Providing & fixing of Earthing Complete job by G.I Pipe 40 mm or G.I rod 20mm 2.5mtr long through G.I Strip as per REC standard
Cement Bottoming of Poles of 11 Mtr Long in 1:2:4 Mix(0.6 cum/pole) as per REC standard complete job
Galvanized stay set with 50x8mm Stay Clamps, Guy Insulator, Anchor plat (300x300x8)mm, Nuts/Bolts, Turn Buckle, 1.8Mt Long 20mm Dia Solid GS Stay rod & 7/4.00mm Dia GI Stay wire complete.
Guard Netting with G wire as per REC Standard complete job with average span length of 58 Meters
CI X arms 10 Ft Long 100x50x6mm
CI X arms 8 Ft Long 100x50x6mm
Angle iron braces 12 ft long 50x50mm
angle iron braces 07 ft long 50x50mm
33 KV isolator with clamps and channel iron
Flat iron 50x6mm
SUPPLY PART- Realignment of existing 33 KV Khellani-Bhaderwah line ( New Line )
Providing of 11Mtr Long S.T poles(410SP-56) complete with base plate and cap as per REC standards and specification.
Providing of 0.1 ACSR(DOG) Conductor
Providing of 33kV Polymeric Composite Pin Insulator 36KV, 10KN, Lightning Impulse 170KN Positive & 180 kV Negative, Creepage distance 900mm
Providing of 33kV Polymeric Composite Disc Insulator 36KV, Min falling load 70KN, Lightning Impulse 170KN Positive & 180 kV Negative, Creepage distance 900mm suitable for 0.1 ACSR Conductor
Providing of PG Clamps for 100 mm sq ACSR
Galvanized stay set with 50x8mm Stay Clamps, Guy Insulator, Anchor plat (300x300x8)mm, Nuts/Bolts, Turn Buckle, 1.8Mt Long 20mm Dia Solid GS Stay rod & 7/4.00mm Dia GI Stay wire complete.
Guard Netting with GI wire as per REC Standard complete job with average span length of 58 Meters
Channel iron for cross arms 100x50x6mm
Providing and fixing Danger Plates with clamps
Anticlimbling devices with clamps
Providing & fixing of Earthing Complete by G.I Pipe 40mm or G.I rod 20mm 2.5mtr long through G.I Strip as per REC standard
Red Oxide including painting job
Almunium Paint (Two coats ) including painting job
Cement Bottoming of Poles of 11 Mtr Long upper ground and under ground in 1:2:4 Mix(0.6 cum/pole) as per REC complete job
Al. Jointing sleaves
Galvinized Nuts and bolts
Angle iron braces 12 ft long 50x50mm
angle iron braces 07 ft long 50x50mm
Flat iron 50x6mm
BOQ 2 - ERECTION PART Stablization of 33kV line from Khellani to Bhaderwah twin Transmission line
Erection, testing and commissioning of 11Mtr Long S.T poles(410SP-56) complete with base plate and cap as per REC standards and specification.
Laying, stringing, binding and commissioning of 0.1 ACSR(DOG) Conductor
Restringing of loose and sagged conductor including repair/jointing works and jumper setting
Straightening of tilted poles with proper setting
Replacement of all bad jumper
Galvanized stay set with 50x8mm Stay Clamps, Guy Insulator, Anchor plat (300x300x8)mm, Nuts/Bolts, Turn Buckle, 1.8Mt Long 20mm Dia Solid GS Stay rod & 7/4.00mm Dia GI Stay wire complete.
33 KV isolator with clamps and channel iron
Flat iron 50x6mm
Erection Part - Realignment of existing 33 KV Khellani-Bhaderwah line
Erection, testing and commissioning of 11Mtr Long S.T poles(410SP-56) complete with base plate and cap as per REC standards and specification.
Laying, stringing, binding and commissioning of 0.1 ACSR(DOG) Conductor
Installation of Galvanized stay set with 50x8mm Stay Clamps, Guy Insulator, Anchor plat (300x300x8)mm, Nuts/Bolts, Turn Buckle, 1.8Mt Long 20mm Dia Solid GS Stay rod & 7/4.00mm Dia GI Stay wire complete.
Fixing of Anticlimbling devices with clamps
Flat iron 50x6mm
Dismentaling
11Mtr Long S.T poles(410SP-56) complete including cross arm, braces and clamps and insulators
0.1 ACSR(DOG) Conductor and carriage to site of erection or store
Lokesh Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .