| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.9 L+₹1.9 L (9.09%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | Rejected-Technical | - | Rejected-Technical Scanned copy of similar work order and MSME Udyog Aadhar or NSIC not furnished |
Tender Value
Refer Docs
EMD Value
₹35,000
Closing Date
15 Nov 2023, 3:00 pmClosed
The Director, ICAR -IIHR
ICAR-IIHR,Hesserghatta Lake post Bangalore-560089
Construction of Tin shade structure along with the side and electrical installation with wiring of seed processing lab at ICAR-IIHR,CHES-Bhubaneswar, Odisha 751019
2023_DARE_778174_1
F.No.5-60/2023-24/SP/IIHR
Open Tender
Civil Works
Works
60 days
CHES-Bhubaneswar
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹35,000
12 Jan 2024
26 Oct 2023
17 Nov 2023
26 Oct 2023
15 Nov 2023
26 Oct 2023
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(item code:15.3)
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar (item code:15.7.4)
2 x 20.5m x 0.25m x 0.60m
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (item code:5.2.2)
8 x 0.60m x 0.30m x 3.00m
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts (item code:5.9.6)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Hot rolled deformed bars (item code:5.22A.4)
Brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand) (item code:6.34.1)
2 x 14.5m x 3.00m x 0.25m
1 x 7.20m x 3.00m x 0.25m
1/2 x 7.20m x 1.20m x 0.25m
20 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) (item code:13.6.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (item code:13.80)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (item code:13.48.1)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) (item code:21.1.2.2)
1x1.2x2.1=2.52m2 @ 9kg
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge .(Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ sqm) (item code:21.3.3)
Providing and fixing GI metal ceiling system of 600 x 600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with the help of nylon sleeves and wooden screws at 300 mm center to center, suspending the main C carrier of size 10x38x10 mm made of GI steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspenssion clip and main carrier bracket at 1000 mm c/c. inverted triangle shaped spring tee having height of 24 mm and width of 34 mm made of GI steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centres with help of suspension brackets. wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with:clip in plain beveled edge global white color tiles of size 600 x 600 and 0.5 mm thick with 25 mm height, made of GI sheet having galvanizing of 100 gms/ sqm (both side inclusive) and 20% preforation area with 1.88 mm dia holes and having NRC of 0.5, electro statically polyster powder coated of thickness 60 microns (minimum) including factory painted after bending and perforation.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes (item code:10.16.2)
For one no. trusss Ridge beam (65mm dia) 1no x 8.40m = 8.40m King post (60mm dia) 1no x 1.20m = 1.20m 9.60m @6.42kg/m = 61.63kg Side post(50mm dia) 2 x 1.20m = 2.40m 2 x 1.60m =1.20m Strut(50mm dia) 2x 1.20m = 2.40m 2 x 0.90m = 1.80m Principal rafter(50mm dia) 2 x 4.50m = 9.00m 16.80m @5.03kg/m = 84.50kg 146.13 kg For 4nos of truss = 4 x 146.13 kg
Prulin (40mm dia -medium) 7nos x 21.0m= 147.00m Bottom cord (40mm dia -medium) 5nos x 21.00m = 105.00m 252.00m @3.50kg/m
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(10mm size MS plate) (item code:10.2)
2 x 8nos x 0.30m x 0.30m = 1.44m2 @78.4kg/m2
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(item code:12.50)
Providingand fixing of anchor bolt (20mm) with nuts complete set for installation of truss ystem as per the instruction of Engineer-in-charge.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) (item code:12.51.1)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth) (item code:12.51.6)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter (item code:12.41.2)
6nos x 12.0m
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Coupler 110 mm (item code:12.42.1.2)
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain) 110 mm Shoe (item code:12.42.6.2)
Dismantling of existing water supply line with overehad tank and resetting the same for supply of water as required. The damage part of pipe of required dia and ancellories fitting to be provided such as control valve etc. as required.
Providing and fixing roof top exhaust fan of throat size 600mm of polycarbonated made as per the instruction.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with gray cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc. complete ( size of tiles 600 x 600mm)
ELECTRICAL
Supplying and fixing of following ways surface/ recess(4+12) mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Wiring for circuit/main wiring alongwith earth wire with the following sizes(4 X 6 sq. mm + 2 X 6 sq. mm earth wire) of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required .
Wiring for sub main/circuit wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 5 pin 15/16 A modular socket outlet and 2 nos. 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 3 nos. 5 pin 5/6 A modular socket outlet and 3 nos. 5/6 A modular switch, connections etc. as required.
Wiring for power point wiring alongwith earth wire with the following sizes (2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire)of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
Supplying and fixing of 63A 4pole MCB as required.
Supplying and fixing of 25A C type SP MCB as required.
Supplying and fixing of 16A C type SP MCB as required.
Supplying and fixing of 78W high speed ceiling fan(48'') with good star rating as required.
Supplying and fixing of 40W LED ceilling surface 2 x 2 pannel light.
Supplying and fixing of DP switch board
ABHIPSHA MOHANTY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .