Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-Finance | ₹14.6 L | L1 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per the terms and conditions of NABI MOHALI. |
| 2 | L2₹14.7 L+₹18,435.20 (1.27%)Accepted-Finance | ₹14.7 L+₹18,435.20 (1.27%) | L2 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per the terms and conditions of NABI MOHALI. |
| 3 | L3₹14.9 L+₹32,233.60 (2.22%)Accepted-Finance | ₹14.9 L+₹32,233.60 (2.22%) | L3 | Accepted-Finance The Quoted amount is inclusive of GST and comply as per the terms and conditions of NABI MOHALI. |
Tender Value
Refer Docs
EMD Value
₹29,633
Closing Date
6 Aug 2020, 4:00 pmClosed
MANAGER ADMIN
KNOWLEDGE CITY SECTOR 81 MOHALI
SITC of VRV AC System with AHU at Glass House
2020_NABI_572959_1
NABI/7(226)/2020-WORKS
Open Tender
Electrical Works
Works
42 days
NABI CAMPUS
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
NABI
₹29,633
Yes
16 Dec 2020
23 Jul 2020
7 Aug 2020
23 Jul 2020
6 Aug 2020
23 Jul 2020
Supply, Installation, Testing and commissioning of factory built Floor Mounted double skin air handling units with existing VRV outdoor condensing units of suitable capacities to cater air load as mentioned below and suitable AHU kit. The units shall be of thermal break profile made of 40±2 mm thick panels miminum 4 rows deep cooling coil section suitable for DX Application with aluminium finned copper tubes (tubes thickness not less than 0.5 mm), filter section with 50 mm thick metal viscous/ washable synthetic type air pre filters, belt drive package with TEFC drive motor (IE-3 ) suitable for 415 ± 10% V, 50Hz, 3 Phase AC supply compatible for drain connections, stainless steel (18G) drain pan with nitrile rubber insulation, auto purge valve wherever required, necessary vibration isolation arrangement, with metallic flange inside AHU, gravity louver complete as required and as per specifications, drawings and of following capacities.(Air Qty : 12000 CFM, Static Pressure : 65 mm). The coil tonnage shall be as per the heat load calculations and as per the site requirement.
Lifting, shifting, positioning, vaccumization, installation, testing & commissioning of existing outdoor VRV units of rating 14.83Tr (18HP)
Supply & Filling of Refrigerant R410A in Outdoor VRV units of rating 14.83Tr (18HP)
Supply and Installation of Expansion kit suitable as per the site requirement
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (41.27 mm dia(OD)/Hard drawn with tube thickness minimum 1.62mm with 19mm thick insulation)
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (28.58 mm dia(OD)/Hard drawn with tube thickness minimum 1.2mm with 19mm thick insulation)
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (19 mm dia (OD)/Hard drawn with tube thickness minimum 1.2mm with 19mm thick insulation)
Supply, Installation, Interconnecting, Testing & Commissioning including vaccumization and Nitrogen testing of new refrigerant soft/hard drawn copper piping between each set of indoor & outdoor VRV units, with all piping properly supported, jointing/brazing including accessories,insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines,all accessories as per specifications etc. complete as per the site requirement (15.86 mm dia (OD)/Soft drawn with tube thickness minimum 1.2mm with 19mm thick insulation)
Supply and Installation of Refnet Unit of suitable size as per the site requirement
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required(Thickness 24 Gauge sheet)
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required(Thickness 22 Gauge sheet)
Supplying and fixing of 19mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required.
Supply & Fixing of Acoustic lining of ducting with 10mm thick open cell Nitrile rubber having density 144-180 kg/m3
Supply & Fixing of Canvas Connection for Supply & return Air ducts
Supply & Fixing of GI drain piping with 6mm thick Closed cell elastomeric type Insulation of following size with clamps/supports etc. complete as per the site requirement (32 mm dia)
Supply, Laying, connecting, testing and commissioning of new control cum transmission copper flexible cable of size 2 core x 1.0 sq mm in suitable size existing PVC conduits between AHU & VRV outdoor units and to central remote, if applicable
Supply & Fixing of MS Heavy duty VRV Outdoor Units Frames
Supply, Installation, Testing & Commissioning of AHU control and starter Panel with suitable rating VFD. Panel will contain Starter for AHU and ELCB for Outddor units. Panel will have the protection from Over voltage and under voltage etc. complete as per the site requirement
Supply, Laying and fixing of one number XLPE insulated and PVC sheathed, Aluminium conductor power cable of 1.1 KV grade of following size on existing cable tray as required- 4core x 16sq. mm (clamped with 1mm thick saddle)
Supply, Laying and fixing of one number XLPE insulated and PVC sheathed, Aluminium conductor power cable of 1.1 KV grade of following size on existing cable tray as required- 4core x 10sq. mm (clamped with 1mm thick saddle)
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, with GI cover, joined with connectors, fixed on the floor with painted MS Angular supports including G.I. bolts & nuts, etc. as required. (225 mm width X 50 mm depth X 1.6 mm thickness)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(4C X 10 sq. mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(4C X 16 sq. mm)
Dismantling & Shifting of Existing duct to NABI stores as per the site requirement
Supply & Installation of Duct Heaters of suitable capacity in supply air duct of AHU as per the site requirement
Agile Engineers
SMD SOLUTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .