Maintenance and Toughened Glass Partition/Electrical /CAMC of IT and Furniture work at EKN , New Delhi
NSL/CEO/DBN/NIT/2026/912
NSL/CEO/DBN/NIT/2026/912
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹2,950
₹71,653
20 Jun 2026
20 Jun 2026
29 Jun 2026
29 Jun 2026
SL No DESCRIPTION AMOUNT (Rs.)
1 Civil Maintenance Works 1209963.55
2 Electrical Maintenance Works 1478475.33
CAMC of EPAX , 22 Nos Wifi and 22 Nos PC including 11
printers of office.
Estimate for Toughned Glass Partition/Electrical /CAMC of IT
& Furniture work at EKN New Delhi.
TOTAL with GST 7165329.88
Digitally signed by AMIT
BOQ for Internal maintenance CAMC of IT Equipment and other speical works at DBN office ,3rd Floor, Tower 1, EKN, New Delhi
BILL OF QUANTITIES
S.No. Description of item of work Unit QTY RATE IN RS. AMOUNT IN RS
1 Civil Maintenance work
Maintenance Service charges of works as per the below mentioned procedures as per the directions of Engineer In charge.
Repair works as per the below mentioned procedures as per the directions of Engineer In charge. Month 24 12996.81 3,11,923.41
a) Periodical Maintenance of drainage network manually or using Pressure jetting machines twice in a year or more, if required, i/c desiliting
of , gratings, chocked sewer line, water closet including all the vertical stacks of Sanitary twice in a year or more ,if required, to the
entire satisfaction of Engineer - in - Charge.
b) Maintenance and cleaning of balcony and washroom, kitchen waterproofing works etc,.
c) Maintenance and operation of water supply grid and valves to keep the water supply system efficient and operational at all times to the
entire satisfaction and as per direction of the Engineer - in - Charge.
d) Maintenance and repairing of Stone cladding including joint filling, crack repairing and replacement of stone, Sculptures,damaged doors,
windows, ventilators of steel, aluminium, wood , PVC, Gypsuma and wooden False ceiling, trap doors i/c repair/ replacement of necessary
fittings & fixtures of approved make (or orginal make as per instruction of EIC) and quality, wherever required to keep them in proper
functional conditions to the entire satisfaction of the Engineer - in - charge (EIC).
e) Maintenance and repair of plumbing system in all toilets and kitchen including stopping leakages or over flow of water ,cisterns and
replacement of damaged fittings i/c CP Brass fitting, ball cocks and G.I., PVC fittings sensor device, hand drier, soap dispenser, Mirror
etc. to keep the entire water supply system efficient and functional to the entire satisfaction of Engineer - in - charge . contractor shall
replace all fittings which have lost its esthetic view, colour, polish as per orginal installment with approved or original make as per
instruction of EIC.
f) Maintenance and repair of internal & external plaster, repair and repaint of all area paints (external paint, textured paint, structural steel
paint) flooring ,pavements, pavor block masonry & RCC works, pointing on roof tiles, patch plaster and full plaster,CC gola i/c fixing of
W.C. seat, gully trap, W.C trap, floor traps and sealing of leakages from gully trap, W.C trap, floor trap, drainage and vertical stacks,
expansion joints etc. and restoration of existing finishing in the affected areas to match with adjacent finishes and to the entire satisfaction
of Engineer -in - charge.
g) Welding by electric plant/Machine including transportation of electric welding plant at site to weld broken grills, hinges, doors, windows,
gates, railing and any other steel work etc.complete as per direction of Engineer -in - charge .
h) Investigating causes of seepage / dampness/ leakage from wall, floors, pipes expansion joints of all kinds etc., dismantling existing
affected portion, arranging required materials, labours, T&P, lift/ ladder or jhulla(if required)/stagging including taking all necessary
measures, rectification complete in all respect in time bound manner to the entire satisfaction of Engineer - in - charge .
i) Closing holes in walls, ceilings, floors or any wherelse including repairing with cement mortar to prevent entry of rats & others animals.
j) Recording & maintenance of the complaints register received at service centres in person or through telephone or email or any other
mode or online complaint monitoring system and assigning the complaint to the workers of respective trade.
k) Preparing the abstract of attended / unattended complaints on daily, weekly and monthly basis and submitting the same with reasons of
unattended complaints and action plan for redressal of pending complaint to the Engineer - in - charge of NSL or his authorized
representative.
l) Weekly preventive maintenance shall be essentially carried out by deploying full team on Saturday and Sundays to check each & every
civil , electrical, fire fighting, fire alarm , items etc and maintained the record .
m) Any other works in connection with the smooth operation & maintenance work not mentioned above ,but required to be carried out
within the cost and/ or also as per direction of the Engineer -in - charge .
n) All kinds of blinds (manual or motorised ) shall be repaired, maintained as per director of EIC
o) Wall painting with plastic emulsion paint or existing paint of approved brand and manufacture to give an even shade:One or more coats on
p) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on
q) Repairs to plaster of any thickness under, including cutting the patch in proper shape, raking out joints and preparing and plastering the
surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Total amount (Civil works) 12,09,963.55
Total amount (Civil works) 12,09,963.55
2 Electrical and Mechanical Maintenance work
Maintenance & repair of works as per the below mentioned procedures as per the directions of Engineer In charge. Month 24 16081.14 3,85,947.33
a) All inclusive comprehensive maintenance , upkeep of all electrical internal installations, Lights, Fans, Geysers etc. as per details below
for all days in a month i/c holidays complete with materials , consumables, bulb, tubes, LED lights etc as per terms and conditions
attached and as per direction of Engineer -in-Charge.
S.No. Description of item of work Unit QTY RATE IN RS. AMOUNT IN RS
b) • Light points/ Fan pts/ Ex-fan pts./ Call bell pts.
• 5 amp plug points
• 15 amp power plug points
• Telephone outlet, TV Outlet
• Telephone wire, TV Wire
• SP, SPN, TP & TPN MCB DB’s with MCB’s
• Bus Bars, Bus duct
• Cable trays of different size
• 63 / 100 amps TP & N Switch units
• 125 Amp. TP MCCB’s
• And others as desired by Engineer-in-charge.
c) Supply of one nos multi tasking highly skilled person who will work as a supervisor for all 7 days Month 24 45522.00 10,92,528.00
Total amount (Electrical and mechanical) 14,78,475.33
Total amount (Electrical and mechanical) 14,78,475.33
MR CAMC of EPAX , 22 Nos Wifi and 22 Nos PC including 11 printers of office. Year 2.00 3,80,000.00 7,60,000.00
Total amount for CAMC works 7,60,000.00
Total amount for CAMC works 7,60,000.00
Desception Unit Qty Rate Amount DSR Amount NDSR
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and
DSR- fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required Sqm 30.00 5,325.90 1,59,777.00
2022 door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Supply and installation of 5 mm toughened frameless glass at workstation table, including providing and installing L-shaped Patti for
stianless steel (ss) proper support and finishing, complete in all respects.”
Supply and installation of Aluminium Framed Glass Partition for minimal frame, room dividing solutions. Single glazed demountable glass
partition using clear toughened glass in proprietary natural anodized finish. Clip-on / U-Section of size 30mm x 21mm with suitable
gaskets for insertion with glass. It also consists of clipper two way Clear Profiles, 90 Degree L Junction and T Junction profiles suitably to
be used as per room configuration designs.
MR Glass thickness - 12mm (LSG). Sqm 300.00 5,800.00 17,40,000.00
All Profiles are min 2.5mm thickness excluding 20 microns of Anodizing, Standards applicable.
• Aluminium profile made by Al Alloy 6063-T6 Grade including all the fittings complete as per site requirement and direction of EIC
Providing and Fixing ESDH 1236-22X922 mm Dtype Handle Material : Stainless Steel. Finish : Satin Stainless Steel (SSS). of approved
make and model all complete as per the direction of Engineer-in-charge.
Providing and Fixing EMB 245 SS Mortise Lock Body SB/TB for door thickness 25-50 mm for of approved make and model all complete as
per the direction of Engineer-in-charge.
Providing & Fixing Frosted Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL-effect film to reproduce Sand-blasting effect on
glass with customised designs, thickness of 2 mil (0.05mm) without adhesive & 3mil (0.8)with adhesive having minimum tensile strength
MR of 3.5 pound/inch at 73 F(0.6 kg/cm at 23 C). Adhesion after 24hrs of installation should be 4 pounds/inch (0.7 kg/cm) on Acrylic, Glass Sqm 300.00 1,500.00 4,50,000.00
Polycarbonate: MCS warranty of 3yrs (if exposed to direct sunlight) to 15yrs (indoors) must be endorsed by 3M India Limited Architectural
Market Department. Contractors payment wouldn't be released until & unless he/she produces orginal warranty certificate from the
Electrical work
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in
1.10 surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm.
FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for group controlled (looped) light point/ fan point/call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC
1.55 insulated copper conductor single core cable in surface / recessed PVC conduit, and earthing the point with 1.5 sq.mm. FRLS PVC insulated
copper conductor single core cable etc as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding
S.No. Description of item of work Unit QTY RATE IN RS. AMOUNT IN RS
1.24.4 3 pin 5/6 amp socket outlet Each 30.00 122.00 3,660.00
1.24.5 6 pin 15/16 amp socket outlet Each 30.00 197.00 5,910.00
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/module, GI box along with Modular base & cover plate on existing modular metal boxes etc. as
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in
1.14 surface/ recessed steel conduit as required
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Metre 200.00 334.00 66,800.00
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre 30.00 439.00 13,170.00
Distribution Boards
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following
2.10 poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.15 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a
2.5 Supplying and fixing following way, vertical type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess,
2.14 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a
LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt)
Supplying of Panel light 2x2 ft., of following body material and construction
as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz,
temp range -15 deg to 40 deg centigrade, internal surge protection of
2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20,
CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be
below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000
Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT
SDCM(Standard Deviation Color Matching) <3, Maximum power
DSR/4258 consumption should not more than the specified rating and Fixture shall be of Nos 50.00 2,700.00 1,35,000.00
relevant BIS standard and trade mark certificate (T.C.). Manufactures Word
Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete
in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated
copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output . LM79 & LM80 Test report from NABL lab for all testing required
for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be
as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction
temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness >
1.53 supply and Drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/PVC conduit as required.
Supply , Installtion , Testing and Comissioning of I/O port for CAT6 cable termination at Work Station end. Keystone Unshielded Outlet,
180DG C6, Blue and modular I/O Box
S.No. Description of item of work Unit QTY RATE IN RS. AMOUNT IN RS
Supply , Installtion , Testing and Comissioning of I/O port for CAT6 cable termination at Work Station end Redantant . Keystone
Unshielded Outlet, 180DG C6, Yellow and Modular O/I Box
Supplying & Fixing of Cabin Table 2400X900X750 LXWXH as per specifications 42 mm Top and 25 mm Legs with 3 Drawer Mobile Pedestal
with Side Unit. As per approved Design & Instructions of Site Incharge.
Supplying & Placing High Back Revolving Chair Chrome Base,PP Arms, Cushioned Seat Back With Leatherite upholstrey with Shyinchro
Mechaanisum White as per approved Design & Instruction of Site Incharge
Supplying & Placing Visitor Static Chair Chrome Base,PU Adjuestable Arms, Cushioned Seat With Fabric upholstrey and Mesh Fabric Back
with adjustable Headrest & Adjustable Lumber e as per approved Design & Instruction of Site Incharge
Total Amount (DSR+NDSR) 37,16,891.00
Total Amount (DSR+NDSR) 37,16,891.00
Total Amount ( Civil +Electrical+Partition works ) 71,65,329.88
Total Amount ( Civil +Electrical+Partition works ) 71,65,329.88
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT DBN.pdf
Tender Document
boq dbn.pdf
Tender Document
scc DBN.pdf
Tender Document
GCC 2026.pdf
Tender Document
Instruction to Bidder for online Bid Submission.pdf
Tender Document
updated forms.pdf
Tender Document
list of make.pdf
Tender Document
Download all tender documents and submit your bid