Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹31,700Qualified Make: SAFEPRO
Model: SPFSPL6 16 B KURLA INDUSTRIAL ESTATE NEAR SEVA SADAN ROAD NARAYAN NAGAR GHATKOPAR W MUMBAI MAHARASHTRA 400086 | MUMBAI SUBURBAN | MAHARASHTRA | 400086 | Make: SAFEPRO
Model: SPFSPL6 | L1 | Qualified | |
| 2 | L2₹36,250+₹4,550 (14.4%)Qualified Make: LIFESECURE
Model: Lifesecure, Model-854 E 173 SECTOR 4 DSIIDC INDUSTRIAL AREA BAWANA DELHI 110039 NORTH WEST DELHI DELHI 110039 | NORTH DELHI | DELHI | 110039 | Make: LIFESECURE
Model: Lifesecure, Model-854 | L2 | Qualified | |
| 3 | L3₹40,500+₹8,800 (27.8%)Qualified Make: IFP FIRRECHEK
Model: IFP FIRECHEK 60A PANDIT MADAN MOHAN MALABYA SARANI CHAKRABERIA ROAD NORTH KOLKATA WEST BENGAL 700020 | KOLKATA | WEST BENGAL | 700020 | Make: IFP FIRRECHEK
Model: IFP FIRECHEK | L3 | Qualified | |
| 4 | L4₹40,975+₹9,275 (29.3%)Qualified Make: 4P FIRE
Model: 4P-ABC-R6 HOUSE NO 337 14 STREET NO 8 ARJUN NAGAR GURUGRAM GURGAON HARYANA 122001 INDIA | GURUGRAM | HARYANA | 122001 | Make: 4P FIRE
Model: 4P-ABC-R6 | L4 | Qualified | |
| 5 | Disqualified Make: NA
Model: Portable Fire Extinguishers IS 15683 B H CHANDRAMANI HOSPITAL SHAHIBAUG AHMEDABAD AHMEDABAD CITY GUJARAT 380004 | AHMADABAD | GUJARAT | 380004 | Make: NA
Model: Portable Fire Extinguishers IS 15683 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 May 2018, 4:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 25 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. N/A Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Powder Based powderbased Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA N/A Powder Based Extinguishing Media ABC N/A Clean Agents Based Extinguishing Media NA N/A Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) 6 6 Carbon Dioxide Based Fire Extinguisher NA 2
3
4.5
NA 1/5 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2
NA Weight of Filled Portable Fire Extinghuisher (Kg) 9 Rechargebale true N/A Color Coding Blue N/A Fire Extinguisher Suitable for Class -A Fire true N/A Fire Extinguisher Suitable for Class -B Fire true N/A Fire Extinguisher Suitable for Class -C Fire true N/A Fire Extinguisher Suitable for Class -D Fire false N/A Fire Extinguisher Suitable for electrical Fire true N/A Performance Operating Temperature (° C) -10° C to + 55° C N/A Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar
Burst Pressure >=55 Bar N/A Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA N/A Discharge Range for Extinguisher (Meters) >=2 for Class-A N/A Effective Discharge Time for Fire Extinguisher
Min (Seconds) 8 Fire Rating for Class -A Fire Extinguisher 3A N/A Fire Rating for Class -B Fire Extinguisher 21B N/A 2/5 Certification BIS Marking Yes N/A CM/L No.* with Validity Period 3985085/22-08-2018 N/A Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES N/A Test Report No. 536 N/A Test Report Date 30-01-2018 N/A Name of the Lab Advance Firetech And Research Lab Pvt Ltd N/A Address of the Lab B- Mangolpuri Indl Area
Phase II
Delhi - 110034 N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr Omkar Singh 744204
Medical Superintendent Dr R.P. Hospital
Mayabunder Mayabunder
North & Middle Andaman 25 30 EMD Required No ePBG Required No
20325
GEM/2018/B/2888
Portable Fire Extinguishers IS 15683
30 days
Andaman And Nicobar Islands; North And Middle Andaman
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 25 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. N/A Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Powder Based powderbased Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA N/A Powder Based Extinguishing Media ABC N/A Clean Agents Based Extinguishing Media NA N/A Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) 6 6 Carbon Dioxide Based Fire Extinguisher NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA 1/5 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) NA 2 | - | - | - |
| NA Weight of Filled Portable Fire Extinghuisher (Kg) 9 Rechargebale true N/A Color Coding Blue N/A Fire Extinguisher Suitable for Class -A Fire true N/A Fire Extinguisher Suitable for Class -B Fire true N/A Fire Extinguisher Suitable for Class -C Fire true N/A Fire Extinguisher Suitable for Class -D Fire false N/A Fire Extinguisher Suitable for electrical Fire true N/A Performance Operating Temperature (° C) -10° C to + 55° C N/A Test pressure/Burst Pressurire Extinguisher except CO2 for water/Foam/Powder type fire extinguisher Test Pressure >=20 Bar | - | - | - |
| Burst Pressure >=55 Bar N/A Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA N/A Discharge Range for Extinguisher (Meters) >=2 for Class-A N/A Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 8 Fire Rating for Class -A Fire Extinguisher 3A N/A Fire Rating for Class -B Fire Extinguisher 21B N/A 2/5 Certification BIS Marking Yes N/A CM/L No.* with Validity Period 3985085/22-08-2018 N/A Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES N/A Test Report No. 536 N/A Test Report Date 30-01-2018 N/A Name of the Lab Advance Firetech And Research Lab Pvt Ltd N/A Address of the Lab B- Mangolpuri Indl Area | - | - | - |
| Phase II | - | - | - |
| Delhi - 110034 N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dr Omkar Singh 744204 | - | - | - |
| Medical Superintendent Dr R.P. Hospital | - | - | - |
| Mayabunder Mayabunder | - | - | - |
| North & Middle Andaman 25 30 EMD Required No ePBG Required No | - | - | - |
Exempted
5 May 2018
21 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_20325.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .