| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 408 POOJA NIWAS RANJANPADA POST JASAI TAL URAN DIST RAIGAD NAVI MUMBAI URAN RAIGAD MAHARASHTRA 400707 | RAIGAD | MAHARASHTRA | 400707 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 1 A STAR MANSION 66 WODEHOUSE ROAD COLABA MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance 2189 167 PLOT NO 96 97 KH NO 143 GANESH PURA B TRI NAGAR NORTH WEST DELHI DELHI 110035 | NORTH WEST DELHI | DELHI | 110035 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
3 Feb 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Dy Manager PPD
Admin Building, JNPA, Sheva, Navi Mumbai
Quotation for Firefighting works at Multipurpose Hall in JNPA Township
2025_JNPT_846196_1
PPD/DGM/MP Hall/2025/14
Open Tender
Miscellaneous Works
Item Rate
Jawaharlal Nehru Port Authority
Please refer Tender documents.
1 document required · 1 mandatory
₹0
Exempted
4 Feb 2025
27 Jan 2025
4 Feb 2025
27 Jan 2025
3 Feb 2025
27 Jan 2025
Amount
Providing and fixing Pendent 15mm Sprinkler Point
Providing and fixing Side Wall Sprinkler size 15mm including all nesseceary fittings
Providing, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm G.I pipe Approved item in SPORTS FACILITIES AND CONSTRUCTION
Providing, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm G.I pipe Approved item in SPORTS FACILITIES AND CONSTRUCTION
Providing, laying, testing & commissioning of 'C' class heavy duty GI pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50mm G.I pipe Approved item in SPORTS FACILITIES AND CONSTRUCTION
Providing and fixing Control Panel for the main and jockey pump
4 Way Inlet
2 Way Inlet
Single headed fire hydrant valve as per IS : 5290 having ISI Mark
Providing and fixing Fire hose (Canvas) pipe 15mtr. Long
Providing and fixing SS Nozzle
Double Door Fire Hose Box - Single M.S. fabricated box made out of 18 swg suitable to accommodate one fire hose pipe of 15 mtr long & one branch pipe having front glass door with panel lock & key.
Providng and fixing Non return valve 150mm
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm dia Approved item in SPORTS FACILITIES AND CONSTRUCTION
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 150mm
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100mm dia Approved item in SPORTS FACILITIES AND CONSTRUCTION
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80mm
Supply and Installation of approved makes FOOT VALVE to with necessary bolts, nuts, gaskets, packing complete open/shut position duly indicated as approved by ISI etc. completed. 150mm
Supply and Installation of approved makes FOOT VALVE to with necessary bolts, nuts, gaskets, packing complete open/shut position duly indicated as approved by ISI etc. completed. 80mm
Supply, installation, Testing & commissioning of Air vessel tank set as per design & Drawing or as per direction by Engineer In Charge
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. Approved item in SPORTS FACILITIES AND CONSTRUCTION
Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station. Approved item in SPORTS FACILITIES AND CONSTRUCTION
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Approved item in SPORTS FACILITIES AND CONSTRUCTION
Supplying and errecting mains with 4 X 25 sq mm and earth wire FRLS PVC copper wire
Supplying and errecting mains with 4 X 4 sq mm and earth wire FRLS PVC copper wire
Support and Accessories (Required Trey 75mm, Gland 10mm/4mm, Bullet fastner, Angle Support, Tie & Earthing patti etc.)
FIRE ALARM
Supply, installation, testing and commissioning of 2 loop analogue addressable fire alarm panel with battery backup, it is a 318-point addressable fire alarm control panel with optional Digital Alarm Communicator / Transmitter and expandable to addressable points with an optional second Signaling Line Circuit.
Supply, installation, testing and commissioning of Analogue Addressable twin chamber Photoelectrical type, Below False ceiling mounted Smoke Detector with Mounting base.
Supply, installation, testing and commissioning of Analogue Addressable Type , ceiling mounted Heat Detector with Mounting base.
Providing and fixing M.C.P on near main door
Supply, installation, testing and commissioning of analogue addressable Hooter.
Supply and drawing of 2C x 1.5 Sq. mm Twisted copper FRLS Armoured cable fixed on the surface of the building structure complete with termination and testing as per requirement for detectors, break glass units and hooters to the fire alarm panel as required. Cable to be directly clamp it on wall, slab etc.
Istallation/Programing for Fire alarm system (Softwear)
FIRE EXTINGUISHER
ABC type of Fire extinguisher of 4 Kg cap. complete ready for use as per IS 2171 having Mark Seasfire
Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
Supply, installation, Testing & commissioning 4 kg K Type Fire extingusher ISI Mark or as per direction by Engineer In Charge
SIGNAGES
Supply, installation, Testing & commissioning of LED Fire exit sinages os per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Signages Extinguisher as per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Signages M.C.P as per design & Drawing or as per direction by Engineer In Charge
Supply, installation, Testing & commissioning of Signages Entry/Exit as per design & Drawing or as per direction by Engineer In Charge
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythylerand built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres
Supply and fixing of 1mm (10% +/-) Polymer Based false ceiling of approved manufacturer with Perforation if deemed required, of panel sizes of 340mmx 3060mm//340mm x 4000mm along with option to custom size to a maximum of 1280 mm in length in approved shade, manufactured in India, made with High temperature thermal transfer technology, waterproof, fire retardant and anti-bacterial. Termite resistant, rust proof material. Panels to be installed with GI sections of suitable gauge & size, subject to change according to site conditions. Panels to be installed using suitable, same shade J-Trim with dimensions 39x20x3060/4000 (all in mm) for edge profiles and Connector with dimensions 76x20x3060/4000 mm, using same shade for connecting panels, using outside corner with dimensions 61x63x3060, which can be used in +90 degree corners and inside corner having dimensions 28x76x3060 which can be used for -90 degree corners. Panels are maintenance free and with 10 years warranty for colour & finish of the panels Including trims of approved manufacturer recommended. All material, accessories, ancillary components all as per recommendation of approved manufacturer. The rates shall be inclusive of all material, labour, wastage, scaffolding upto 12 ft. , all lead & lifts, making cut-out for light fixture and other MEP utilities as per GFC drawing and making good with suitable accessories etc. all complete as per manufacturer and as directed by the architect
PYRO DEFENCE CONTROL SYSTEM (BID ID -3165504)
M/s. PAINTERIOR PROTECTIVE SYSTEMS LLP (BID ID -3165242)
SONALI CONSTRUTIONS (BID ID -3165274)
CGS Construction (BID ID -3165356)
DAULAT CONSTRUCTION (BID ID -3165035)
MORYA SAI ABHINAV SAHAKARI SEVA SANSTHA MARYADIT (BID ID -3165357)
UNIVERSAL FIRE AND SAFETY SERVICES (BID ID -3165577)
stage.html
html • 0.03 MB
finance_889500.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .