Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.5 CrAccepted-AOC | ₹3.5 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹4.2 Cr+₹67.1 L (19.3%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹4.2 Cr+₹67.1 L (19.3%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | Rejected-Technical V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | - | - | Rejected-Technical The firm is enlisted two class below the eligibility creteria. |
Tender Value
₹3.3 Cr
EMD Value
₹4.0 L
Closing Date
19 Apr 2022, 12:00 pmClosed
CE (CG) GOA
Head Quarters Chief Engineer Coast Guard Chicolna JNC Nagar Road Bogmalo Post Goa 403 806
PROVISION OF SEWAGE TREATMENT PLANT (STP) IN TRV CHICOLNA, GOA
2022_MES_512562_1
81085E8
Open Tender
Civil Works
Lump-sum
360 days
CE (CG) GOA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹2,000
Yes
GE(I) CG GOA
₹4.0 L
17 Oct 2022
8 Mar 2022
20 Apr 2022
8 Mar 2022
19 Apr 2022
5 Apr 2022
Amount
Schedule A Part I to Part X
Total amount of Sch 'A' Part-I (Buildings & Structures)
Total amount of Sch 'A' Part-II (SITE CLEARANCE, EXCAVATION & EARTH WORK )
Total amount of Sch 'A' Part-III (DEMOLITION)
Total amount of Sch 'A' Part-IV (INTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part-V (INTERNAL ELECTRIFICATION)
Total amount of Sch 'A' Part-VI (PQC ROAD)
Total amount of Sch 'A' Part-VII (RETAINING WALL)
Total amount of Sch 'A' Part-VIII (ADDITION/ ALTERATION OF SEWAGE LINE)
Total amount of Sch 'A' Part - IX(EXTERNAL WATER SUPPLY)
Total amount of Sch 'A' Part- X (EXTERNAL ELECTRIC SUPPLY)
Total amount of Sch 'A' Part- X I(CIVIL WORKS OF STP)
STP E/M PORTION Design, Supply, construction, installation, testing & commissioning of Sewage Treatment Plant based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) having capacity 400 KLD, including required foundations and the following as per the specifications.
Two no. Fine bar screen of MSEP construction as per given minimum specifications, to be installed in Fine Bar screen chamber, to prevent floating objects passing through it and subsequently removing manually and dumped for further disposal. Designed for : a) Maximum Velocity through Screen at Peak Flow = 0.6 m/sec b) Minimum Velocity through Screen at Average Flow = 0.3 m/sec c) Clear Area of Opening through Screen for Peak Flow = 0.014 m3/sec d) Clear Spacing of Bars = 6 mm e) Thickness of Bars = 5 mm f) Gross Area of Screen 0.042 m2 g) Assuming Depth of Screen Channel 0.300 m h) Gross Width of Screen 0.141 m j) No. of Bars = 12 No. k) Width of Screen provided = 200mm The screen shall be fabricated out of stainless-steel SS 304
One lot of air grid for equalization tank for providing aeration in the tank, as specified in PS. Air Grid Type : Header & lateral MOC of Air Grid : uPVC Aeration air required : 71 m/hr Opening of the same should be downwards (facing the floor of the process reactor) Make : Thermax / Optimus Enviropro / SIMA Lab/ Ion Exchange
Four nos. raw sewage centrifugal mono bloc pumps complete with motor and all necessary accessories and fittings, to be installed for transferring sewage from equalization tank to process reactor. Level sensor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Sewage submersible Solid Handling : 20 mm Qty. : 04 Nos. (2W + 2S) Head : 14 m Make:Kirloskar / KSB / Grundfoss
Four nos. twin lobe type Air blower with motor, for providing air in equalization tank, MBBR reactors & Sludge holding tank. One no. Air rotameter is to be provided in each line to MBBR reactor 1 & 2, equalisation tank, sludge holding tank for measurement of quantity of air. Air Grid Type : Header & Lateral Type MOC : SS304 Casing : C I conformimg to IS: 210 Gr FG 260 Rotor : Alloy Steel Shaft : Carbon Steel C40/EN 24/19 Timing Gear : Cast Alloy Steel Pulley and gear side plates and cover : C I conforming to IS 210 Gr FG 260 Make : Everest / KPT / Atlas Capco / Kaesar / Aerzen
Two nos. anoxic chamber in MSFRP construction with all internals comprising of media, media retaining sieves and Mixer. MOC : MS FRP (6 mm thick MS Sheet & 3 mm thick FRP) Total Volume : 8.05 m3 Recirculation Flow : 2.55 i.e. 30% of regular flow Surface Area : 1.61 m Diameter : 1.43 m Make : Thermax / Optimus Enviropro / SIMA Lab/ Ion Exchange
Four nos. MBBR tanks in MSFRP construction with all internals comprising of media, SS air grid & SS rise pipe, media retaining sieves, etc. MOC : MS FRP (6 mm thick MS Sheet & 3mm thick FRP) Average Flow : 200.00 m3/d No. of Units : 2.00 Nos. Recirculation flow : 2.55 m3 Each tank volume required : 16.30 m3 Diameter : 2.04 m Make : Thermax / Optimus Enviropro / SIMA Lab/ Ion Exchange
Four nos. sludge transfer self priming monobloc pumps complete with motor and all necessary accessories and fittings for transferring sludge from bottom of the tube settler to the sludge holding tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Monobloc, sewage self primimg pumps Qty. : 04 Nos. (2W + 2S) Head : 6 m Make : Kirloskar / C&G / KSB / Mather & Platt
Two nos. tube settler tank in MS FRP construction with media & collection trough. MOC : MS FRP (6 mm thick MS Sheet & 3 mm thick FRP) Average Flow : 200.00 m3/d Unit : 2.00 Nos. Length : 2.10 m Width : 2.50 m Total Height : 4.20 m. Make : Thermax / Optimus Enviro / SIMA Lab/ Ion Exchange
Four nos. sewage centrifugal monobloc self-priming recirculation pumps complete with motor and all necessary accessories and fittings for recirculation of biomass with sewage to the anoxic chamber. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Sewage Self priming Centrifugal Qty. : 4 Nos. (2W + 2S) Head : 8 m Make : Kirloskar / KSB / Grundfoss
One no. Sludge Holding Tank in MS FRP construction, as per given specifications, to receive sludge from tube settler by gravity. MOC : MS FRP (6 mm thick MS Steel & 3 mm thick FRP) Volume of tank : 7.7 m3 Length : 2.5 m Width : 2.1 m Depth : 1.5 m Make : Thermax / Optimus Enviro / SIMA Lab/ Ion Exchange
One no. Chlorine Contact cum Filter feed tank in MS FRP construction, as per given specifications. MOC : MS FRP (6mm thick MS Sheet & 3 mm thick FRP) Flow : 400.00 m3/d Length : 2.10 m Width : 3.60 m Volume : 11.34 m No. of Baffle Wall : Two Make : Thermax / Optimus Enviropro / SIMA Lab/ Ion Exchange
One set of Sodium Hypo Chlorite dosing system comprising of 2 nos. dosing pump and one no. Solution tank, all as specified. Make : Minimax / eDose
Two nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, Level sensor should be provided in the chlorine contact cum filter feed tank and interlinked with pumps for ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. Type : Centrifugal Monobloc MOC : Cast Iron Qty. : Nos. (1W + 1S) Capacity : 18.18 m3/hr. Head : 26 m Make:Kirloskar / KSB / Grundfoss
One no. Dual Media filter, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter. MOC : Mild Steel bituminous pain inside Thickness of Sheet : 6 mm shell/ 8 mm dish Design Flow : 18.18 m3/hr No. of Filter : 1.00 Nos. Dia. Of Filter : 1.30 m Height : 1.8 m Make : MES aprooved vendors
One no. Activated Carbon Filter of complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter. MOC : Mild Steel bituminous paint inside Thickness of Sheet : 5 mm shell/ 6mm dish Design Flow : 18.18 m3/hr. No. of Filters : 1.00 Nos. Dia. Of filter : 1.4 m Height : 1.8 m Make : MES aprooved vendors
One no. Tertiary Treated Water tank in MS FRP construction, to receive supernatant coming from tertiary treatment plant, as per given specification. MOC : MS FRP ( 6 mm thick MS Sheet & 3 mm thick FRP) Qty. : 1 No. Volume : 10 m3 Length : 2.5 m Width : 2.7 m Depth : 1.5 m Make : Thermax / Optimus Enviropro / SIMA Lab/ Ion Exchange
Two nos. sludge transfer self priming monobloc pumps complete with motor and all necessary accessories and fittings for sludge screw press , Level sensor should be provided in the sludge holding tank and interlinked with pumps for ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. MOC : Cast Iron Type : Centrifugal monobloc self priming Qty. : 2 Nos. (1W+1) Flow : 2.0 m3/hr Head : 8 m Make : Kirloskar / Johnson / Willo / KSB
One no. Continuous feed sludge screw press with dosing system for sludge dewatering system as specified in PS Qty. : 01 Nos. Total Power : 0.50 HP Power Supply : 400 v/ 50 Hz 3 phase. All as per detailed specifications attached. Make : Huber / FKC Screw / Aadys / AMCON
Two nos. electromagnetic flow meter Make : Crohne Marshall / IOTA / Electronet
One lot of suitable size Piping & valves of suitable material to interconnect various units of sewage treatment plant, as per approved drawings
One lot of Power & control cables to interconnect various drives and instrumentations with STP panel.
One lot of stairs, platform, railing, etc. as shown in drawing.
One lot of suitable size Piping & valves of suitable material to interconnect various units of sewage treatment plant, as per approved drawings
One lot of Power & control cable to interconnect various drives and instrumentations with STP panel.
One lot of stairs, platform railing etc. as shown in drawing.
INTERNAL WATER SUPPLY S&F 15mm dia CP brass angle valves with CP nuts and washers. CP brass valve flange with any other items complete including cutting and making good
EXTERNAL WATER SUPPLY Supply and fix Sluice Valves, , flanged of class PN 1.6, 100 mm (4”)dia
Supply and fix Sluice Valves, , flanged of class PN 1.6 , 80 mm (3”)dia
Supply and fix CPVC Valves, Sluice, flanged of class class PN 1.6, 50 mm (2”)dia
Supply, install, test and commissioning Pump set, centrifugal Monoblock, electric driven, 3Ph, 415 V, 50 Hz of capacity 250 LPM at 30 Mtr head complete with necessary suction side GI pipe medium grade, , pressure gauge & PCC foundation and connecting up with delivery main complete all as per manufacturer's specification and all as specified.
Material and Labour for construction of valve chamberof size 900 X 900 X 900MM depth (internal dimension) with PCC foundation in the ratio 1:4:8 brick work in cement motor in the ratio 1:4 using class B bricks,.PCC coping at the Top in the Ratio 1:2:4; Plastering 15mm thick in the ratio 1:4 including painting with antifungal paint of 2 coats inside and out side the wall of chamber including MS sheet cover 3.15 mm thick with angle iron frame 70 x 70 x 3.15mm, locking arrangement complete with painting on steel surfaces with one coat of red oxide paint over two coats of synthetic enamalled paint all as specified and and directed. Note : (Rate includes excavation earthwork complete all as specivied)
EXTERNAL ELECTRIC SUPPLY Supply and erect factory made precast RCC pole, 9 m long,130mm x 100mm at top and 230mm x 150 mm at bottom, conforming to IS 785:1964 complete all as specified & directed.
Supply and fix street light luminaire with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK07 suitable for LED 45 watt IP-65 complete with Wiring including fixing bracket made of GI tubing medium grade 40 mm dia, 1.5 mtr long with flat iron clamps, nuts, Bolts, washers etc and connecting up from terminal box using 3- core 1.5 sqmm flexible copper conductor cable complete.
Supply and fixing SMC junction Box size 200x140x95 MM Internal Size with hinged door (L) with 01 No. PVC Connector 4-way, 16Amps and 01 No.MCB SP 6 Amps including fixing bracket,nuts,bolts etc. complete Make:- Sintex Cat part No. GSJB2014 or Equivalent of National.
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings INCOMING:- (a) MCCB with thermal release, 4 pole, 100 amps, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB with thermal release, 4 pole, 100 amps, 50 Hz, 415 Volt, 25 KA-1 No. (b) MCCB with thermal release, 4 pole, 63 amps, 50 Hz, 415 Volt, 16 KA - 2 No. (c ) MCB TPN, 16Amps 415 V, 10 KA - 05 Nos (d) MCB SPN, 32 Amps 240 Volts, 10 KA - 01 Nos (e) Timer switches 250 V single Phase of 20 Amp rating with contactor- 01 No.
Supply and fix MCCB with thermal based release 4 pole, 100 AMPS, 50 Hz, 415 Volts, 25 KA in and including Sheet metal enclosure outdoor type made out of 3.15mm CRCA sheet mounted on angle iron pedestal including grouting complete all as specified.
Supplying, installing, testing and commissioning, factory assembled silent Diesel Engine driven generator set, fully wired alternator AC to give an out put of 40 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hz ± 1% supply, 1500RPM, directly coupled with diesel engine water cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, control panel & other accessories etc and comprising of following:-
(A) Diesel Engine: Water cooled turbo charged with after cooler to deliver suitable BHP at 1500RPM under NTP conditions of BS 5514 and conforming to IS 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:- Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries of adequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete. (Make : Cummins/KOEL/Greaves power/Mahindra) (a) Radiator with blower fan or heat exchanger with guard. (b) Pipe coupling for engine cooling system piping. (c ) Corrosion inhibitor coolant (d) Paper element filters (i) Fuel (ii) Lube oil (iii) By pass (e) Fly wheel housing and fly wheel to suit alternator. (f) Engine bearing mechanism in fly wheel housing. (g) Shut off coil with safeties for LLOP/HWT/over speed. (h) Dry type air cleaners and vacuum indicators. (j) Residential silencers. (k) Stainless steel exhaust flexible bellows.
(l) Motor driven priming pump. (m) Battery charging alternator. (n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) battery voltage (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed. (v) Engine hours. (vI) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-1No. 12 volts DC, 180AH, maintenance free battery with leads & terminals (Make- Excide/Amron). (z) Fuel tank: 08 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed
(B) Alternator: Suitable rated at 40 KVA factor , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof , insulation class H IP -23, self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before. (Make : KOEL/Crompton Greaves/Stamford)
(C) Acoustic Enclosure:- M & L for acoustic enclosure for the above 40 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :- (i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt FTL fitting of make Phillips/ Bajaj/ Crompton.
(D) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:
(i) AMF control circuit with 4 pole MCCB 63 Amps with ultimate breaking capacity Icu-35 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts of 16 KA, thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc. (ii) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.
(E) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation recommended by manufacturers. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.
INTERNAL ELECTRIFICATION: S&F 20W surface/wall mounted LED batten having high efficiency long life LED chips with luminious efficiency of >100 lumen/W, Conforming to IS 15885(Part2/sec-13):2012 polycarbonate diffuser, extruded Aluminium housing and white colour ABS end caps having input voltage 220-240V 50-60Hz PF>0.95. complete all as specified and directed. Make: Halonix cat part no. HLB-08-20-CW-AL or Equivelent in Havells/Wipro/ Bajaj
S&F 10W surface/wall mounted LED batten having high efficiency long life LED chips with luminious efficiency of >100 lumen/W, Conforming to IS 15885(Part2/sec-13):2012 polycarbonate diffuser, extruded Aluminium housing and white colour ABS end caps having input voltage 220-240V 50-60Hz PF>0.95. complete all as specified and directed. Make: Halonix cat part no. HLB-08-10-CW-AL or Equivelent in Havells/Wipro/ Bajaj
S&F 25W LED Street Light, pressure die cast housing, prismatic polycarbonate difuser, LEDs with secondary optics and IP65 Protection complte all as secified and directed Make: Bajaj Cat No: 169821 BCLST 25W LED I or Equivalent in Wipro/Havells/Halonix
S & F energy efficient five star rated ceiling fan of size 1200 mm sweep complete with stepped type electronic regulator and down rod including provision of flexible copper cable 3 core of size 0.5 sqmm from ceiling rose to fan, provision of 3 mm thick circular Bakelite sheet cover including writing MES NO. 2 CM height with synthetic enamel black paint all as specified and as directed. Make: BAJAJ Kassels star or equivalent model of Usha/ Crompton/ Havells
S&F and connecting up non-metallic fresh air fan (For toilet) 250mm sweep, Delivery not less than 860CMH, heavy duty single phase 240 volts AC 50 Hz and connecting up complete including louvres and including provision of cable 3 core, 0.5 Sqmm multi-stranded copper conductor PVC insulated and PVC sheathed flexible wire from ceiling rose to fan all as specified and as directed. Including writing MES NO. 2 CM height with synthetic enamelled black paint all as specified and as directed. Make: Crompton VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S & F for MCB SPN 240 volt C curve of 16 Amps capacity complete all as specified and directed. Make:Havells Cat No DHMGCTPE006-032 or equivalent in Legrand/ Indoasian/ HPL
S & F for MCB SP 240 volt C curve of 6 Amps capacity complete all as specified and directed. Make:Havells Cat No DHMGCTPE006-032 or equivalent in Legrand/ Indoasian/ HPL
S & F for MCB SP 240 volt C curve of 10 Amps capacity complete all as specified and directed. Make:Havells Cat No DHMGCTPE006-032 or equivalent in Legrand/ Indoasian/ HPL
M&L for earthing with 600x600x 6mm GI earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including GI earth lead of wire 4.00mm by means of brass bolts, nuts and check nuts and washers of galvanized iron connected to test point. GI tubing 40mm bore medium grade protection pipe, GI watering pipe 20mm bore medium grade with funnel and wire mesh, charcoal and salt, CI cover with suitable handle, PCC pit in 1:2:4 including earth work in any type of soil and connecting to earthing test point/ panel and all as shown in electrical plate No - 3 of SSR 2009 - Part-1 Note: The rates for Earthing include the cost of (a) Earth Electrode (b) Main earthing lead from earth electrode to test point upto 7.50 mtrs (c) Material & Labour for connecting earth electrode & earthing lead as specified (d) Adequate quantity of charcoal dust and common salt (e) All labour involved including testing the network
COMPREHENSIVE MAINTENANCE OF STP :- Annual Comprehensive maintenance of Sewage treatment plant (STP) installed of capacity 400KLD at CGRA TRV Chicolna, Goa including required chemicals complete for period of 03years after expiry of defect liability period of 24 months as specified in condition 46 of IAFW-2249
(a) for First Year
(b for Second Year
(c) for ThirdYear
NOTES: (a) Rates quoted for above item of work by the contractor shall be both for material and labour complete unless mentioned. (b) the comprehensive maintenance shall be period of 36 months wef satisfactory completion of 2 years of defect liability period for the complete equipments installed of the STP. (c) The contractor shall be responsible for the periodical maintenance as sprecified including renewal/ replacement of parts, fittings, fixtures etc required for smooth functioning of the plant as per manufacturer's instructions (d) All chemicals such as Poly electrolyte, calcium hypochlorite etc required for smooyh functioning of STP shall be included in quoted rate. (e) Cleaning of oil and grease chamber, screening bar and centifuse filter press and removal of cake shall be carried out by one sweeper employed a week. (f) Material and labour in collection of dried sludge cake in a month and disposed of safely in suitable place not more than 5KM from STP CRGA TRV, Chicolna, Goa. (g) rates also included M & L for painting of MBBR, tube shelter, duel media filter, activated corbon filter, filter feed tank by epoxy enamel paint over a coat of red oxide once in a year
Supply only Sodium Hypochioride calcium based high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (40/ 50 Kg each) chlorine concentration lever 40 - 60%, 60 - 70% and delivered at STP under AGE B/R Goa complete all as specified and as directed ( Make : RAMCO/ POTTER & WATTS corporation or equivalent make)
Supply only Poly electrolyte chemical complete all as directed ( Make : RAMCO/ POTTER & WATTS corporation or equivalent make)
Note apllicable to Item No. 38.00 and 39.00 above: These two items shall be measured and paid during defect liability period of 02 years
MANNING & OPERATION:- Manning and Operation (for Two shifts per day including Sunday & holiday, from 0600Hrs to 1400 Hrs and 1400Hrs to 2000Hrs) by employing with One skilled operator per Shift and maintaining desired level of Chemicals by dosing of required quantity of chemicals provided in system including tracing out and rectification of minor leakages in pipe line/ valves in entire work for all days in week for Sewage Treatment Plant installed of capacity 400KLD complete for a period of 24 months from the date of completion of installation, testing & commissioning work of STP plant with all instruments and controls complete all as directed
(a) Maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the Department. Format of log sheet and records etc shall be decided by GE/ Engineer -in-charge (b) DHPP shall be issued by the department under Sch 'B' as free filling of DG set. The quoted rate deemed to be inclusive of the transportation and filling of FOL issued by the department to the respective installations. Prior intimation three days in advance regarding requirement of FOL for DG set shall be given by the contractor. (c) The quoted rate includeds any type of conveyance for the Trademan/ Helper and the Sch 'B' items. The contractor is responsible for proper observation and intimationabout the servicability of battery and battery charger, oil and fuel level in DG set. It is responsibility of the contractor to rectify and make good the damage to the installations/ accessories if any caused by the operator during his duty. (d) The contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. The shift timings shall be decided by Engineer- in- charge and liable to change as and when required by Engineer- in- charge. (e) Area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (f) The work covered under this schedule shall be order on the contractor by GE every year through seperate work orders at the rate quoted by the contractor till completion of Five years of comprehensive maintenance
Collecting the waster/ effluent sample monthly from STP before and after treatment, sample handling, transporting to NABL accredited lab approved by authorities, carry out analysis of the following latest ISI method (i) BOD (Bio - Chemical oxygen Demand) (ii) COD (Chemical oxygen demand (iii) TSS ( Total suspended solids) (iv) Total disolved solids (v) Turbidity) (vi) PH
Supply and fix centrifugally cast (Spun) DI pipes class K-7, 150mm dia of standard length spigot and socketed end conforming to IS rubber gasket as jointing material, internal cement mortar coating and external surface with bituminous paint, ISI marked all as specified and directed.
M & L for, Ductile iton fittings conforming to IS 8329/2000 such as bnds (any type, redius and angle) tapers any type, (straight, band increase, decreasing or double socket etc) tee pieces class K-12, caps and plugs all as specified and directed.
Refixing of water flow meter showing discharge of water (Cum) of size 150mm dia including dismantling & taking down all as specified and as directed by Engr-in-Charge.
Supply and fix SFRC (Steel fibre reinforced concrete) manual covers including frame set in cement morter (1:4) of grey colour size of opening 600x600mm square shape all as specified and directed.
M/s R. K. Bhambri
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .