Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC 52 A 4TH FLOOR INDIAN REGISTER OF SHIPPING ADI SHANKARACHARYA MARG POWAI LAKE POWAI MUMBAI MAHARASHTRA | L1 | Accepted-AOC Awarded as per terms and conditions of the contract | |
| 2 | L2₹8.1 L+₹1.0 L (14.8%)Rejected-AOC PLOT NO 15 STRUCTWEL PLOT NO 15 SECTOR 24 OFF SION PANVEL HIGHWAY TURBHE TURBHE NAVI MUMBAI 400 705 THANE MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | L2 | Rejected-AOC Rejected, As not identified as L1 | |
| 3 | L3₹10.1 L+₹3.1 L (43.5%)Rejected-AOC GROUND FLOOR 72 BUSINESS PARK CROSS ROAD C MAROL INDUSTRIAL AREA MIDC ANDHERI EAST MUMBAI MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | L3 | Rejected-AOC Rejected, As not identified as L1 | |
| 4 | L4₹13.7 L+₹6.6 L (94.2%)Rejected-AOC 196 GOREGAON W MUMBAI MAHARASHTRA 400062 | 400062 | L4 | Rejected-AOC Rejected, As not identified as L1 | |
| 5 | Rejected-Technical 3 NEW TRIMURTY CO OP HOUSING SOCIETY INGOLE NAGAR WARDHA ROAD NAGPUR 440005 MAHARASTRA | NAGPUR | NAGPUR | MAHARASHTRA | 440005 | - | Rejected-Technical No Office at Hyderabad |
Tender Value
Refer Docs
EMD Value
₹13,650
Closing Date
13 Feb 2025, 11:00 amClosed
DGM, DPSP
NABARD, Telangana Regional Office, 1-1-61 RTC X Roads, Musheerabad, Hyderabad - 500020
SelectionofconsultantforundertakingstructuralAuditofBankspropertiesinTelangana
2025_NABA_845642_2
NB.TGRO/Structural Audit/129080/22012025
Open Tender
Miscellaneous Works
Item Rate
Hyderabad, Telangana
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹13,650
Yes
Hyderabad, Telangana
28 Mar 2025
23 Jan 2025
14 Feb 2025
23 Jan 2025
13 Feb 2025
23 Jan 2025
23 Jan 2025 - 27 Jan 2025
28 Jan 2025
Amount
Rebound Hammer Test Conducting the rebound hammer test with required instruments/ equipment by preparing the surface of RCC structural members such as beams, columns, slabs etc. by chipping the plastered surface/ finishing/ cladding to expose the concrete, smoothening the area using carborundum stone all in terms of relevant IS code : 13311-1992(Part 2) or as directed. The quoted rate shall be inclusive of cost of all tool & tackles, restoration of the test area/spots after conduct of test with matching paint, associated sundry work etc. as well as all applicable taxes
UPV ( Ultrasonic Pulse Velocity ) Test: Preparing the surface of RCC structural members such as beams, columns, slabs etc. by chipping the plastered surface/ finishing/ cladding to expose the concrete, smoothening the area using carborandum stone all in terms of relevant IS code and conducting rebound hammer test all as per IS 13311-1992 (Part 1) or as directed by consultant including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures, if any.
Carbonation Depth Test Preparing the surface of RCC structural member such as beams, columns, slabs, water tank walls & slab etc. by chipping the plastered surface/ finishing/ cladding to expose the concrete, cutting etc. as per relevant code, and conducting carbonation test at various depth as directed by consultant using phenolphthalein of specified concentration to assess depth of carbonation. The ratio of Carbonation depth to cover depth is also to be measured to check the intensity of carbonation attack on steel bar. The quoted rate shall be inclusive of cost of all tool & tackles, restoration of the test area/spots after conduct of test with matching paint, associated sundry work etc. as well as all applicable taxes
Chemical test for Chloride and pH Value Chemical test for chloride and PH from drilled core samples
Concrete Core Extraction and Testing Deciding the location by using “Rebar Locator/Cover Meter” and Preparing the structural members as directed to expose the concrete, cleaning the area with blower /wire brush and taking out the concrete sample with cutter and testing as per standard specification including analysis of the test result & preparation of separate report for each building with observations and recommendations for remedial measures if any.
Consultancy Charges Preparation of building wise structural audit report which includes, a. The findings from detailed visual inspection as in item 1 b Nondestructive test results c Suggested remedial measures d Bill of quantities item wise & detailed specification with cost estimate for each building All based on the visual inspection, NDT, assessment as per item 1 and 2. a Provding fitness certificate post completion of renovation works
Structwel Designers & Consultants Pvt. Ltd. (BID ID -3170701)
Bureau Veritas (India) Pvt. Ltd (BID ID -3163764)
IDDC Engineers Private Limited (BID ID -3170667)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .