| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹20.6 L+₹2.1 L (11.3%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹22.0 L+₹3.5 L (18.9%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹22.5 L+₹4.0 L (21.4%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
14 Sept 2024, 6:00 pmClosed
GE MH AND RH KHADKI
Military Engineer Services Garrison Engineer MH and Range Hills Range Hills Road Khadki, Pune 411003
REPAIR REPLACEMENT OF LIGHTING CONDUCTOR EARTHING OF BLDS INSTALLATIONS AND REPAIRS TO COOLING APPLIANCE ETC UNDER THE AOR OF GE MH AND RH KHADKI
2024_MES_667022_1
8571/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE MH AND RH KHADKI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MH AND RH KHADKI
₹54,000
2 Nov 2024
20 Jul 2024
17 Sept 2024
20 Jul 2024
14 Sept 2024
3 Aug 2024
20 Jul 2024 - 10 Aug 2024
Amount
Comprehensive maintenance and servicing of Split type Air conditioner / Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connectins including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan motor blade/blower drum, main control board PCB, electronic control box, etc, oiling/greasing of fan motor, checking serviceablility, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing and cleaning of area which is made dirty during cleaning & commissioning all as specified and directed by Engineer-in-Charge. Note: (i) Spare parts replaced shall be measured & paid separately under relevant item of this BOQ. (ii) Supply and charging of Nitrogen /Refrigerant gas will be measured and paid separately under relevant item of this BOQ.
Supply only starting capacitor 80-100 Mfd 440 Volts AC, 50Hz for window /split AC of capacity 1.0 / 1.5 TR for AC all as specified and directed of existing make.
Supply only starting capacitor 120 Mfd 440 Volts AC, 50Hz for window /split AC of capacity 2.0 TR for AC all as specified and directed of existing make.
Supply only running capacitor 36 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR.
Supply only running capacitor 50 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR / 2.0 TR
Supply only blower motor capacitor 4 Mfd 440 Volts, 50 Hz AC for window / split type AC of capacity 1.5 TR / 2.0 TR
Supply only blower motor capacitor 6 Mfd 440 Volts, 50 Hz AC
Supply only running capacitor 25 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only for over load relay comprising of over load protection suitable for air conditioner, water cooler, deep freezer and refrigerator operated in single phase 230 volt all as specifed and directed.
Supply only thermostat switch suitable for Air conditioner, water cooler, Deep freezer and Refrigerator operator on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC, water and Refrigerator.
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply only capillary tubes for the Air conditioner 1.5 Ton / 2 ton and water cooler 40 to 150 Ltrs
Supply only indoor fan motor of split type AC of any capacity
Supply only condensor fan motor 1300 rpm, 1/6 Hp, 1/8 Hp, 1/10 Hp for split type Air conditioner outdoor unit of 1.0 Ton/1.5 Ton/2.0 Ton as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor double shaft 1/4 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (indoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/5 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (indoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/6 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (outdoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor double shaft 1/8 Hp, 230 Volts AC for Window type AC of 1.0/1.5 Ton/2.0 Ton (outdoor unit) as make and capacity all as specified and directed by Enginner in charge
Supply only condensor fan motor 1/36 Hp for water cooler of 40-80 Ltr and Deep freezer up to 400 Ltr as per existing make and capacity all as specified and directed by Engineer in charge
Supply only condensor fan motor 1/6 Hp, 1/8 Hp, 1/10 Hp for water cooler of 120-150 Ltr as per existing make and capacity all as specifed and directed by Engineer-in-Charge
Supply only remote control unit of Splity type AC 1.5 Ton / 2.0 Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer-in-Charge
Supply only Electronic PCB unit for main control panel of splity type/window type AC of any capacity
Supply only capillary tubes for the refrigerator & deep freezer up to 400 Ltr
Supply only starting relay suitable for water cooler, AC and Refrigerator, Deep freezer for any make and model operated on single phase 230 volts all as specified and directed.
Supply only thermostat switch suitable for Air conditioner, water cooler, Deep freezer and Refrigerator operator on single phase 230 volts supply all as specified and directed.
Supply only condensor fan motor 1/36 Hp for water cooler of 40-80 Ltr and Deep freezer up to 400 Ltr as per existing make and capacity all as specified and directed by Engineer in charge
Supply only blower/condenser fan blades as per existing make & type for Air conditioner/water cooler/Deep freezer all as specifed and directed.
Supply only starting capacitor 10 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only running capacitor 15 Mfd 440 Volts, 50 Hz AC for water cooler.
Supply only starting capacitor 60 Mfd for water cooler
Supply only starting capacitor 80 Mfd 440 Volts, 50 Hz AC for water cooler.
Repair, replacement and supply, install, test & commissioning harmetically sealed New compressor for the following appliances duly charged with fresh freon gas / R-134 a complete all as specifed and directed by Engineer-in-Charge including taking down old u/s compressor. Make: Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site.
Split type AC of capacity 1.5 TR
Split type AC of capacity 2.0 TR
Window type AC of capacity 1.5 TR
Water cooler of capacity 40 to 80 Ltrs
Water cooler of capacity 120 to 150 Ltrs
Refrigerator 165 to 210 Ltrs
Refrigerator 210 to 310 Ltrs
Deep freezer upt 200 to 400 Ltrs
M & L for detecting the gas leakage with the help of nitrogen gas, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldering etc, vacumizing and charging, topping up fresh freon Gas/ R-22 a and commissioning and testing for the 1.5 Ton/2.0 ton split /window type AC all as specified and directd by Engineer-in-Charge
All as per item No 42 above, but of water cooler/ refrigerator/ deep freezer of any capacity for servicing and gas charging .
All as per item no. 1 for complete servicing of Water cooler / DeepFreezer/ refrigerator
Comprehensive maintenance and service of cold room / walk in cooler unit outer and inner unit both of any make including cleaning the dust from body with blower cleaning of condensor and cooling coil, with castic soda, oiling to motor, cleaning of filter chekcing all electric connection all as speicified and directed by Engr-in-Charge. Note: Spare parts shall me measured and paid seperately as supply only for the following items
Electronic circuit board for walk in cooler
Defrosting timer 40 Amps rating to walk in cooler
Solenoid valve for cold room
Outdoor unit fan motor as per sample
Evaporator fan motor with blade of cold room outdoor unit as per make and model on existing at site
M & L for replacing unserviceable door lock assembly of cold room existing as per site directed by Engr-in-Charge
Replacement of bakelite connector block 30 Amps
Evaporater coil suitable for Cold room of above size
Compressor Suitable for cold Room
M & L for dismantling of existing unserviceable following voltage stabilizer for repairs including replacement of relays, electronic voltage sensor circuits and meter, micro switch, indication light RC filters and other connected items for making functional as per the entire satisifcation of Engr-in-Charge and replace of unserviceable transformer and testing complete.
Up to 1 KVA
Up to 2 KVA
Up to 4 KVA
Up to 5 KVA
Disconnecting electrical /mechanically and lowering to the ground for repairing / over hauling the desert cooler including replacement of canvas grass/ wood wool pads and spray painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully functional including replacement of unserviceable / defective spare parts, transportation to and from, re-installation and testing on completion to the entire satisfaction of Engineer-in-Charge. Note: Spares replaced will be measured and paid separately under respective item of this BOQ as supply only.
Supply only water lifting pump 1/70 HP capcity, operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr-in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs, nuts and bolts etc.
supply only fan blade with bush for desert cooler motor
Supply only electronic control circuit board (PCB) as per existing type for desert cooler
Supply only swing motor for air cooler
S & F metal plug tops for 2 pin and earth socket AC box of capacity 240 V, 20 A all as specified and directed.
Supply only PVC Flexible pipe 25 - 30 mm dia as in drain pipe suitable for water cooler outlet including taking down old unserviceable pipe of any size
S & F incl connecting sheet metal encosure with two pin and earth plug and socket complete, with one double pole MCB 20 Amp 240 Volts AC. Make: L & T/Hager/Schnedier
S & F Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia
S & F in push tap self closing taps of size 15 mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers with taking down old pipe
M & L for repair/ replacement to stainless steel waste water tray including welding, polishing, riveting, provision of fixing screws and refixing
M & L for Gaskets for top cover for water cooler of any capacity and make as per site requirement
Taking out unserviceable cooling coil of 165/285 Ltrs Refrigerator and S & F Cooling coil as per existing make and size all as specified and directred by Engr-in-Charge.
S&F in repairs damage condenser coil for refrigerator of capacity 210/300 Ltrs
S&F in repairs door switch for refrigerator of any type and any capacity
S&F in repairs pigmy lamp (indoor lamp) as per existing type for refrigerator
S&F in repairs freezer door as per existing make and type for refrigerator
S&F in repairs timer switch assembly for refrigerator as per existing for capacity 210 to 310 Ltrs
M & L for carry out routine maintenance, and servicing of package type air conditioner of capacity 7.5/5 TR including removing the dust from body with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checking function of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT control panel, VFDs, electronic control box, etc, oiling/greasing of fan motor checking serviceability cleaning of the air filter woolen felt& refixing ensuring for air tighting complete repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-charge. Note: 1 Spare parts replaces shall be measured & paid under relevant item of this Schedule (BOQ). 2. Gas required for testing and re-filling is deemed to be included in unit rate quoted.
Supply only relay HP & LP for package type AC plant of capacity 7.5 TR
Supply only condensor fan motor, 230 V, 50 Hz 920 rpm 1/3 HP for package type AC 7.5 TR, on exisiting make all as speicifed and directed by Engr-in-charge.
Supply only blower belt of package unit as per exisiting make and model with new one for 7.5 TR Air cooled package type AC plant
Supply only Intigrated circuit board with all electgronic components suitable for 7.5 TR capacity Voltas package type Air conditioner
Supply only SPPR circuit board suitable for 7.5 TR capacity package AC. Make : Voltas
Supply only 3 phase, 415 V, 50 Hz compressor of capacity 7.5 TR suitable for package type AC. Make: Voltas
Supply only fan blade suitable for outdoor unit of capcity 7.5 TR
Supply only Blower motor suitable for Voltas make Ductable type AC of capacity 7.5 TR
Supply only Electronic PCB kit for control panel suitable for Voltas make Package AC of capacity 7.5 TR
Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 volt with auxilary contact 1 NO + 1 NC, having coil voltage 380 to 400 volts Make : Simens cat ref C4NE22 or equivalent make of L & T /Havells
leak testing & gas charging of package type air conditioner of capacity 7.5/5 TR including complete repair and replacement of worn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-charge. Note: 1 Spare parts replaces shall be measured & paid under separte under relevant item of this BOQ as supply only. 2. Gas required for testing and re-filling including quoted rate.
Material and labour for shifting of split AC 1.5 TR & 2.0 TR with all accessoires and installed at new location, including fixing arrangement of indoor/outdor unit along with mounting bracket/Frame including cutting holes to wall and making good disturbed surfaces to match with the existing finish of walls etc complete all as shown and directed by Engr-in-charge. Note: Additonal copper tubing and gas charging as required to make existing AC serviceable at new location shall be measured and paid separately. All other items are deemed to be included in the unit rate quoted.
Supply only copper tubing 5/8" for 1.0/1.5/2.0 TR split AC with proper insulation of suitable size and taking out old one as per directed by Engr-in-Charge.
Supply only copper tubing 1/4" for 1.0/1.5/2.0 TR split AC with proper insulation of suitable size and taking out old one as per directed by Engr-in-Charge.
Taking down of unserviceable copper/GI/Aluminium earthing strip any size complete all as directed.
S&F in replacement copper strip of size 20mmx3mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/down conductor strip etc, complete all as specified and as directed by Engineer-in-charge. Note: Copper strip shall be 99.99% copper to be provided
S&F GI steel strip of size 32mmx6mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as in repair complete all as specified and as directed by Engineer-in-charge.
S&F Aluminium strip of size 25mmx3mm thick for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or roof for lightening arrestor or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing/down strip from from bldgs etc, using porcelain clit/post insulators with screw/GI drill bit screw with clamp of required size at specified distance, complete all as specified and as directed by Engineer-in-charge. Note : The cost of T & P and minor spares reqd for fixing the above conducor is included in the quoted rate.
S&F Earthing test point terminal block made up of gun metal or phosphorus bronze of size 75mmx75mmx25mm thick drilled and screwed including 3Nos, 8mm dia, 25mm long hexagonal head screws including MS box 2 mm thick of suitable size for protection of test point terminal, including dismantling of old unserviceable test point complete all as specified and directed.
S&F Air termination, single pointed Aluminium rod 12mm dia and 300mm long with complete acessories fixed on aluminuim strip for earth conductivity to ground as in repair complete all as specified and as directed by Engineer-in- charge.
M&L for 40 mm bore Galvanised iron tubing, medium grade, IS-1239 marked including ISI marked fittings and laid in trenches/under road/drains, fixed to poles/ walls or fixed to pcc block for fixing air termination rod with suitable size flat iron clamps, bolts, nuts and washers (for fixing Air termination rods) NOTE :- Clamps, nuts & bolts shall be measured and paid for separately.
M&L for 40mm bore galvanised iron pipe, light grade including all fittings and fixed to wall/poles/floors, laid in trenches including taking down old GI pipe, complete, all as specified and as directed by Engr-in-charge. Note :- Excavation & earthwork shall be measured & paid separately under relevent item.
Disconnecting/Taking down old unserviceable Earthing pit of any type with accessories including removing of demolished material from work site at any distance out side MD land complete all as specified and directed.
Supply, installation and commissioning of advance maintenance free system based earthing comprising of following accessories (a) Set of 04 Nos 3000 mm long, 17.0 mm dia earth electrode made of 99.99% copper circular rods with connect copper strip and electrode with the help of copper brazzing of incoming copper strips of size 25 x 3 mm of length as per site requirement upto Bus bar as decided by Engr - in-Charge and distance between each copper earth electrode is minimum 3 Meter . (b) Copper bus bar of size (300 x 25 x 6)mm act as test point connect with copper nuts and bolts with post insulator.(Nuts/bolts as required is included in the cost). (c) Poly propylene earth pit cover of size 300 x 300 mm (with safe working load 2000 Kg) - 04 Nos (d) Copper bus bar of size (250 x 50 x 6)mm exothermically welded with main earth electrode (e) Each pit filled with earth enhancement compound /chemical (Magnesium sulphate) only (min 75 Kgs/pit) all as specified.
(f) Required result of earthing less than 01 Ohm . If desired Ohmic value is not achieved then additional set of 1 No of 3000 mm long, 17.0 mm dia earth electrode made out of 99.9% copper rod with allied items, 01 x Pit cover, 01 x Sub bar as (d) above 75 Kg of chemical shall be provided by contractor without any extra cost to Govt. No price adjustment shall be made, if additional set is not required complete all as directed of Engr- in-charge (g) Necessary excavation work in any type of soil/strata, returning filling and removal of soil is included in the aquoted rates. (h) Site inspection for complete Earthing work is mandotry for the Contractor befour quoting the tender. No explanation/doubts will be entertained later. (j) Any damage done to govt property during the execution of work will be make good by the contractor at his own cost.
Material and labour for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI strip 32x6mm thick, by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit of size 450x450x300mm (outer size) wall thickness 100mm made in PCC (1:3:6) type C-1 and pre-cast reinforced cover slab of size 450mm x 450mm x 80mm thick made with MS XPM Jalli, RCC (1:1.5:3), with one handle made out of 8 mm dia round bar, 20mm dia GI pipe 'light grade' for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work of size 300x900mm, depth 2.50mtr and testing complete all as specified and directed.
NOTE FOR SL NO 11 : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with cement base paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per IS colour code (ii) If the desired earth resistance is not achived during testing as per IS the complete earthing shall be carried out again by the contractor at his own cost and no extra claim shall be admissable. (iii) Length of earth strip/electrode, if more than 7.5mtr shall be measured and paid seperately under respective items of schedule (iv) Resistance value should be less than 5 ohm. (v) Necessary excavation work in any type of soil/strata, returning filling and removal of soil is included in the aquoted rates. (iv) Site inspection for lightining conductor work is mandotry for the Contractor befour quoting the tender. No explanation/doubts will be entertained later. (vii) Any damage done to govt property during the execution of work will be make good by the contractor at his own cost. (viii) The work of lightining conductor is to be done in Roofs of the bldgs in Insp org area.
Material and labour for earthing with copper earth plate electrode 600mm x 600mm x 3mm thick, burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip 20x3mm thick, by means of copper brazzing made out of copper steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit of size 450x450x300mm (outer size) wall thickness 100mm made in PCC (1:3:6) type C-1 and pre-cast reinforced cover slab of size 450mm x 450mm x 80mm thick made with MS XPM Jalli, RCC (1:1.5:3), with one handle made out of 8 mm dia round bar, 20mm dia GI pipe 'light grade' for watering funnels, wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work of size 300x900mm, depth 2.50mtr and testing complete all as specified and directed.
NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with cement base paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL as per colour code followed. (ii) If the desired earth registance is not achive during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissable. (iii) Length of earth strip/electrode, if more than 7.5mtr shall be measured and apid seperately under respective items of schedule (iv) Resistance value should be less than 5 ohm. (v) Copper plate shall be 99.99% copper.
M & L for fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers etc including welding, bending cold or hot, drilling holes for bolts, in any shape or size including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping, bed plate kerbs including weathering slightly rounded or chamfered angles and throating etc as directed.
Surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr including cutting vegetation complete all as specified and directed. Note :- Item shall be executed twice in each installation and quantity is given for two operation. However unit rate to be quoted by the tendered for single operation only.
S&F PCC M-10 grade (nominal mix) using 40mm graded stone aggrigate for earthing pit of outer size 450x450x300mm, wall thickness 10mm and RCC coverin M-15 grade (nominal mix) using 20mm grade stone aggregate , reinforced with 8mm dia bar both way @150mm c/c of size 450x450x80mm including GI funnel and necessary earth work including taking down old earth pit cover of conventional earthing complete all as directed.
Shriyansh sales and services (BID ID -3096179)
SHREE VAIBHAV ELECTRICALS (BID ID -3091137)
M/S. Niksun Electro-Infra Private Limited (BID ID -3090122)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .